R556 - Reliability Data

Reliability Data Report
Product Family R556
LTC5564
Reliability Data Report
Report Number: R556
Report generated on: Wed Jun 18 10:47:16 PDT 2014
OPERATING LIFE TEST
PACKAGE TYPE
QFN/DFN
Totals
SAMPLE SIZE
154
154
OLDEST DATE
NEWEST DATE
K DEVICE HRS
1
No. of FAILURES
2,3
CODE
CODE
(+125°C)
1020
-
1020
-
154
154
0
0
K DEVICE HRS
No. of FAILURES
PRESSURE COOKER TEST AT 15 PSIG , +121 DEG C
PACKAGE TYPE
SAMPLE SIZE
QFN/DFN
Totals
50
50
OLDEST DATE
NEWEST DATE
CODE
CODE
1234
-
1234
-
1
1
0
0
OLDEST DATE
NEWEST DATE
K DEVICE
No. of FAILURES
CODE
CODE
CYCLES
1234
-
1234
-
5
5
0
0
OLDEST DATE
NEWEST DATE
K DEVICE
No. of FAILURES
CODE
CODE
CYCLES
1234
-
1234
-
5
5
TEMP CYCLE FROM -65 TO 150 DEG C
PACKAGE TYPE
SAMPLE SIZE
QFN/DFN
Totals
50
50
THERMAL SHOCK FROM -65 TO 150 DEG C
PACKAGE TYPE
SAMPLE SIZE
QFN/DFN
Totals
50
50
(1) Assumes Activation Energy = 0.7 Electron Volts
(2) Failure Rate Equivalent to +55 °C, 60% Confidence Level =76.94 FITS
(3) Mean Time Between Failure in Years = 1483.65
Note: 1 FIT = 1 Failure in One Billion Hours.
Note 2: HAST, Temp Cycle & Thermal Shock are subjected to J-STD-020 MSL1 Preconditioning
0
0