Specifications for UT Inverter/Chargers 932433

200801172 93-2433.qxd
1/24/2008
12:12 PM
Page 1
Specifications
MODEL NUMBER:
UT750UL
UT1250UL
UT2012UL
AGAP5088
AGAP5217
AGAP5290
UL 458 (US & Canada - TUV Tested)
UL 458 (US & Canada - TUV Tested)
UL 458 (US & Canada)
Input Cord
Input Cord
Input Cord
Two GFCI Outlets
Two GFCI Outlets
Two GFCI Outlets
Series Number:
Agency Approvals:
AC Input Connection (for optional charging):
AC Output Connection:
INVERTER
Continuous Power (@ 20 C):
750
1250
2000
OverPower™ Peak Surge Power:*
1125
1875
3000
Double Boost™ Peak Surge Power:*
1500
2500
4000
Maximum Output AC Current (Continuous):
6.3 A
10.4 A
16.7 A
One 125 A
One 200 A
Two 175 A
72 A
127 A
190 A
12 VDC
12 VDC
12 VDC
UL-Recognized DC Fuse Required:
DC Input Current @ Nominal V DC Full Load:
DC Input Volts (Nominal):
DC Input Voltage Range:
Output Volts (Nominal):
Output Frequency (Nominal):
10-15 VDC
10-15 VDC
10-15 VDC
120 VAC, ± 5%
120 VAC, ± 5%
120 VAC, ± 5%
60 Hz, ± 0.5 %
60 Hz, ± 0.5 %
60 Hz, ± 0.5%
88% to 94%, depending on
load and temperature
88% to 94%, depending on
load and temperature
88% to 94%, depending on
load and temperature
Selectable 45 A** / 11 A
Selectable 40 A** / 10 A
Selectable 60 A** / 15 A
9.3 A
8.2 A
12 A
Selectable 14.4V** / 14.2 V Wet** / Gel
Selectable 14.4V** / 14.2 V Wet** / Gel
Selectable 14.4 V** /14.2 V Wet** / Gel
13.3 V (13.6 V)
13.3 V (13.6 V)
13.3 V (13.6 V)
120 VAC
120 VAC
120 VAC
Efficiency:
BATTERY CHARGER
Charging Capacity DC:
Input Current AC:
Acceptance Volts VDC:
Float Volts DC (Wet/Gel):
Input Volts (Nominal):
* OverPower duration (up to 1 hour). DoubleBoost duration (up to 10 seconds). Actual duration depends on battery age, battery charge level and ambient temperature. **Factory setting.
Minimum Recommended Cable Sizing Chart†
Use in conjunction with DC wiring connection instructions in the Battery Connection section.
Note on Labeling Two symbols are used on the unit labels.
V~: AC Voltage V : DC Voltage
Inverter DC Volt: 12
Wire Gauge
Watts
6
4
2
0
00 (2/0)
500
700
1000
2000
15 ft
11 ft
N/R
N/R
25 ft
18 ft
12 ft
N/R
39 ft
28 ft
20 ft
N/R
62 ft
44 ft
31 ft
16 ft
79 ft
56 ft
39 ft
20 ft
† N/R = Not Recommended. NOTE: Acceptable power is directly related to
cable length (i.e. - the shorter the cable, the better the performance)
Warning: Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit's internal
cooling, eventually causing product damage not covered under warranty.
Warning: Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life
support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product
nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should
not be confused with the marking name or model number of the product.
Tripp Lite follows a policy of continuous improvement. Specifications are subject to change without notice.
Made in China.
1111 W. 35th Street Chicago, IL 60609 • (773) 869-1234 • www.tripplite.com
200801172 93-2433