Tripp Lite 120V Inverter/Chargers Brochure 953222 (English)

INVERTERS & INVERTER/CHARGERS
PowerVerter DC-to-AC
Inverters & Inverter/Chargers
®
Convert stored battery power to standard household
current for mobile, emergency backup and
remote site applications.
Convert stored battery power to standard household current for mobile, emergency backup
and remote site applications. Convert stored battery power to standard household current
for mobile, emergency backup and remote site applications. Convert stored battery power to
standard household current for mobile, emergency backup and remote site applications.
Convert stored battery power to standard household current for mobile, emergency backup
and remote site applications. Convert stored battery power to standard household current for
mobile, emergency backup and remote site applications. Convert stored battery power to
standard household current for mobile, emergency backup and remote site applications.
Convert stored battery power to standard household current for mobile, emergency backup
and remote site applications. Convert stored battery power to standard household current for
mobile, emergency backup and remote site applications. Convert stored battery power to
standard household current for mobile, emergencyCONTENTS
backup and remote site applications.
Convert stored battery power to standard householdIntroduction
current for mobile, emergency
backup
2
and remote site applications. Convert stored battery power to standard household current for
Inverters
3
mobile, emergency backup and remote site applications. Convert stored battery power to
Inverter/Chargers
4
standard household current for mobile, emergency backup and remote site applications.
Sine Wave
Inverter/Chargers
5
Convert stored battery power to standard household current for mobile, emergency backup
and remote site applications. Convert stored battery power to standard household current for
Feature Focus
6-7
mobile, emergency backup and remote site applications. Convert stored battery power to
Specifications
8
standard household current for mobile, emergency backup and remote site applications.
Convert stored battery power to standard household current for mobile, emergency backup
INTRODUCTION
Inverters and Inverter/Chargers Provide Reliable Power for
Mobile, Emergency Backup and Remote Site Applications
Remote Job Sites
Trucks, Boats and RVs
Off-Grid Locations
Inverters use
Inverters
Inverter/
your vehicle’s
and Inverter/
Chargers store
battery to power
Chargers power
power from
tools, chargers
computers,
generators
and other
appliances,
and renewable
equipment in
electronics and
energy sources,
any location. Inverter/Chargers also
other equipment in transport trucks, boats
saving fuel and ensuring power availability
provide convenient battery backup and
and recreational vehicles, reducing engine
during non-generational periods, such as
condition generator output.
wear, fuel use, noise and pollution.
nighttime hours.
Emergency Power
Mobile Professionals
Healthcare
Inverters and
Inverters provide
Medical-Grade
Inverter/Chargers
portable power
and Ambulance
provide backup
for laptops,
Inverter/
power, convert
mobile phones
Chargers
vehicles into
and chargers
provide mobile
emergency
inside vehicles
power for
generators and allow you to run
without the expense and inconvenience of
medical equipment in ambulances,
generators less often to conserve fuel
carrying special adapters for each device.
hospitals and other healthcare settings,
during severe weather and other outages.
including patient care areas.
How to Choose the Right Model for Your Application
1
Decide whether you need an Inverter or an Inverter/Charger.
Both Inverters and Inverter/Chargers provide household current (120 V AC) from stored battery power, but only Inverter/Chargers connect to AC sources, pass AC through to equipment, recharge batteries and automatically switch to battery when AC power
is unavailable. Inverters do not connect to AC sources and rely on vehicles to recharge batteries.
2
Determine the wattage required by connected equipment.
The continuous output rating (see page 8) of the Inverter or Inverter/Charger you choose must be greater than the wattage of the equipment you will power. (Add up the wattages of any equipment that will be powered simultaneously.) Equipment wattages are typically listed on nameplates or in manuals. If equipment is rated in amps, multiply by 120 V to estimate wattage.
3
Decide whether you need special features.
Many Inverters and Inverter/Chargers have features that make them especially suitable for certain applications:
• Models with GFCI outlets meet OSHA requirements for worker protection in wet or humid environments.
• Heavy-duty models support demanding inductive loads like motors, compressors and pumps.
• Models with sine wave output and fast transfer times are ideal for backing up sensitive electronics like computers
and network equipment. Some devices require sine wave output, including computers with active PFC power supplies.
Need More Help?
Visit www.tripplite.com/selectors to use Tripp Lite’s dynamic Inverter and Inverter/Charger Selector to
choose the features you need and see matches instantly, including specifications, pricing and links to
online resellers. You can also reach our dedicated technical support team by calling 773.869.1234
or sending e-mail to [email protected].
2
DC-TO-AC INVERTERS
PowerVerter Inverters
• Up to 3,000 Watts Continuous and 6,000 Watts Peak Surge Output
PV2000FC
• Protection Against Surges, Line Noise and Unstable Voltages
PV375
• Portable, Permanent-Mount and Heavy-Duty Models Available
Support Applications of All Sizes
Handle Peak Power Demands
PowerVerter Inverters convert DC power from a vehicle or boat
Many tools, appliances and electronics require more power at
battery into household AC power (120 V) to run a variety of power
startup, during use or both. Motors found in equipment like
tools, electronics and appliances.
refrigerators and pumps have fluctuating power demands, starting
• Portable Inverters are perfect for mobile professionals,
business travelers and vacationers who want to operate and
recharge laptops, tablets, smartphones and other devices in
the car without the expense and inconvenience of carrying
automotive chargers for each device.
and stopping intermittently. PowerVerter Inverters handle these
• Heavy-Duty Permanent-Mount Inverters handle the most
demanding applications. Extended
peak surge power
AC
capabilities and conditioned output make them ideal for a
DC
wide variety of equipment, from heavy-duty drills, saws and
pumps to computers, timing motors and sensitive monitoring
equipment.
continuous output ratings to accommodate equipment startup
and cycling requirements.
200% Output
Startup Peak
150% Output
Usage Peak(s)
Watts
• Permanent-Mount Inverters provide higher capacities to
support multiple devices and higher-wattage equipment like
power tools, appliances, desktop computer systems, home
electronics and audio/video equipment.
peak surge power demands by delivering up to 200% of their
Continuous Output
Equipment Load
Time
PowerVerter Inverters handle your equipment’s peak power
demands at startup and during use without shutting down.
AC
Portable
Inverter
DC
Provide Regulated Output
PowerVerter Inverters provide stable output voltage and frequency
to help your equipment perform at its peak, including sensitive
devices like computers and audio/video equipment.
Preserve Your Battery
Through a high-efficiency conversion process and battery charge
conservation, PowerVerter Inverters draw the highest level of
performance from your batteries without overtaxing them,
AC
DC
PermanentMount Inverter
lengthening their service life. Automatic low-battery shutdown
ensures you’ll always have battery power available to start your
vehicle.
AC battery to power equipment that runs or recharges on
Inverters use your vehicle’s
standard AC household current. DC
Go to www.tripplite.com for the latest product and ordering information
3
DC-TO-AC INVERTER/CHARGERS
PowerVerter APS Inverter/Chargers
• Up to 3,600 Watts Continuous and 7,200 Watts Peak Surge Output
• Automatic Transfer from AC Source to Reliable Battery Backup Power
• Protection Against Blackouts, Surges, APS2448UL
UT2012UL
Line Noise and Unstable Voltages
Provide Reliable Backup Power
Inverter/Chargers have all the features of Inverters, plus a battery charger and automatic transfer
Deliver Superior
Output
switch that allow you to use batteries separate from a vehicle’s main battery or outside a vehicle
Inverter/Chargers provide stable
entirely. They provide mobile power, emergency power and backup power for generators
output
and other AC sources. They are especially useful for off-grid locations and vehicles that have
to protect your equipment and
intermittent access to AC “shore power,” such as boats, RVs and transport trucks.
allow it to perform at its peak.
voltage
and
frequency
The Inverter/Charger acts as a
safety buffer, conditioning unstable
power
from
AC
sources
like
generators before it reaches your
equipment. When Inverter/Chargers
operate from battery, the AC output
is controlled by a microprocessor to
AC
provide reliable power at all times.
DC
Shore Power
Charge Batteries
Faster
Inverter/Charger
An
advanced
3-stage
charger
recharges your batteries faster,
while
When an AC source like a generator or shore power is available, the Inverter/Charger conditions AC power before passing
it to your equipment and simultaneously charges your user-supplied batteries. When an AC source is not available (during
power failures, at remote sites, while driving, when disconnected from shore power or when your generator is turned off),
the Inverter/Charger automatically switches to battery power and your equipment
continues to operate without interruption.
protecting
them
against
over-charge, over-discharge and
accidental
depletion.
You
can
connect as many batteries as you
need to increase battery backup
runtime to match any application.
Handle Peak Power
Demands
Many power tools, appliances and
200% Output
Startup Peak
electronics require brief bursts of
power that exceed their continuous
during
use
or
both.
Inverter/
Usage Peak(s)
Watts
wattage ratings, either at startup,
150% Output
Continuous Output
Chargers temporarily provide extra
output power to handle these peak
surge demands without shutting
down. By providing ample reserve
power, Inverter/Chargers support a
much wider range of equipment and
Equipment Load
Time
3-Stage Charging Profile
PowerVerter APS Inverter/Chargers handle your
equipment’s peak power demands at startup and
during use without shutting down.
applications.
4
Go to www.tripplite.com for the latest product and ordering information
DC-TO-AC INVERTER/CHARGERS
Sine Wave Inverter/Chargers
Cleaner, Greener
Backup Power:
Better for You,
Your Equipment
and the Environment
Quiet, Fume-Free Operation
APS2012SW
APS1012SW
With no fumes, fuel
or excess noise,
Inverter/Chargers are
Provide Pure Sine Wave Power
better for applications
PowerVerter APS Sine Wave Inverter/Chargers provide stable, microprocessor-controlled
where generators
output with a pure sine wave. Sine wave power allows your equipment to run cooler, last longer
would be hazardous
and operate without the malfunctions and reduced performance caused by substandard power.
(such as indoors) or too loud (such
Sine wave power also ensures maximum compatibility with sensitive electronics like computers,
as residential areas or outdoor areas
network devices and audio/video equipment. Many devices require sine wave power, including
during quiet hours).
variable-speed power tools and computers with active PFC power supplies.
Fewer Trips to the Pump
Inverter/Chargers
consume no fuel,
drawing power from
AC
your AC source
AC
or battery system
Shore Power
instead. Generators
AC
require frequent, costly trips to the
DC
pump. Inverter/Chargers also store
power while your generator is running,
allowing you to turn it off and save fuel
Sine Wave
Inverter/Charger
without turning off your equipment.
More Reliable Power
Inverter/Chargers
produce stable,
microprocessorcontrolled voltage and
frequency. Generators
can compromise the reliability of your
equipment by producing unstable
voltages, frequency variations and
AC
AC
AC
surges. Inverter/Chargers are ideal
for backing up generators and
conditioning generator output to
DC
AC
AC
Less Maintenance
Sine Wave
Inverter/Charger
Electrical Panel
AC
Utility Power
protect your equipment.
Inverter/Chargers
AC
Renewable
Energy Systems
PowerVerter APS Sine Wave Inverter/Chargers produce sine wave output required by a wide range of devices for
proper operation. Devices that require sine wave power include ATMs, energy-saving fluorescent and LED lights, fans,
variable‑speed power tools, digital clocks, laser printers, audio/video equipment and electronics with active
PFC power supplies, including many computers and peripherals with ENERGY STAR ® ratings. Consult the owner’s
manual or contact the manufacturer for more information about power requirements for your equipment.
provide years of
trouble-free operation
without maintenance.
Generators require
frequent upkeep and parts
replacement, increasing expense and
inconvenience.
5
FEATURE FOCUS
Inverters
J
E
T
G
Q
I
P
A
K
H
A
P
O
A
H
P
K
K
PV375
PV700HF
PV1800HF
Similar Model: PV150 (Single Outlet)
Similar Models: PV1000HF,
PV1800GFCI (2 GFCI Outlets)
E
T
G
I
I
J
P
P
P
O
A
Q
K
T
G
E
J
Included Remote
C
Q
C
O
PV2000FC
PV3000GFCI
Similar Models: PV1250FC, PV2400FC
Similar Model: PV3000HF (Non-GFCI Outlets)
A AC Outlet(s)
B
Hardwire AC Output Terminals
C GFCI AC Outlets
Meet OSHA requirements for GFCI to
protect employees at work sites.
D Hospital-Grade AC Outlets
E
Battery Level LEDs
F
Operation LEDs
Indicate the battery charge level.
Indicate whether the Inverter/Charger is supplying power from an AC source or from battery. Also indicate overloads.
G Load LEDs
Indicate the load level.
(Inverters >700 W only.)
H On/Off Switch
I
J
Operating Mode Switch
“On, Off, Remote” for most Inverters.
“Auto/Remote, Off, Charge Only” for
most Inverter/Chargers.
Battery Conservation Dial
Adjusts the load level below which the unit shuts off to conserve battery power.
K DC Input Terminals
Connect to batteries with user-supplied cabling. (PV150 and PV375 have a cigarette 6
K
lighter plug. EMS1250UL and HCRK-series
have an Anderson quick connector.)
L
Configuration DIP Switches
Additional Features Not Indicated:
Customize settings for your application.
Low Battery Protection
M AC Input Cord/Plug or
Hardwire AC Input Terminals
(Inverter/Chargers only.)
Automatically prevents excessive battery
depletion/damage. (Included with all models.)
Overload Protection
N
Hospital-Grade AC Input Plug
O
Resettable Circuit Breaker(s)
Automatic Transfer Switch
(PV150 and PV375 have a replaceable fuse.)
(Inverter/Chargers only.)
P
Cooling Fan(s)
Durable Case
Q
Grounding Lug
Aluminum, steel and/or polycarbonate.
R
Pure Sine Wave Output
S
Fast Transfer Time
APS2012SW and HCRK-series only.)
Ignition Interlock Jack
T
Remote Control Jack
Connects select models to vehicle’s ignition
switch. (PV1250FC, PV2000FC, RV750ULHW,
PV3000GFCI, APS3636VR, EMS1250UL,
UT-series and HCRK-series.)
U
Battery Temperature Sensor Jack
Ensures that sensitive loads will not be dropped when switching from AC to battery. (APS2448UL, APS1012SW,
Connects to optional or included wired remote. (Remote included with PV3000HF,
V
Enables temperature-compensated
charging to increase battery lifespan.
Remote Generator Controller
Automatically starts generator to keep batteries at an optimal charge level. (Included with “RV” models >750 W.)
(Included with all models.)
Mounting Feet/Flanges
(Included with all models except PV150 and PV375.)
Automatic Voltage Regulation
Corrects abnormal voltages without using battery power. (APS3636VR only.)
RV1250ULHW, RV1512UL, MRV2012UL and
EMS1250UL. Other models may support ignition
interlock through optional APSRM4 wired remote.)
Note: Similar models not shown may vary in
appearance from models shown. For photos of
models not shown, go to www.tripplite.com.
FEATURE FOCUS
Inverter/Chargers
Q
K
P
J
E
L
P
F
E
T F
P
I
L
E
T F
I
I
J
O
O
K
A
A
APS700HF
P
L
E
T
F
Q
RV1250ULHW
Similar Model: APS1250
Similar Models: RV750ULHW,
RV1012ULHW, RV1512UL
R
P
S
E
T
F
I
U
L
T
U
J
B
O
M
Q
O
B
L
E
F
H
M
APS750
I
J
B
K
M
Q
M
U
V
O
O
U
V
B
K
M
M
K
Q
Q
K
APS2012
APS2012SW
MRV2012UL
Similar Models: APS2424,
APS2448UL (Fast Transfer Time),
APS3636VR (AVR, Included Remote)
Similar Model: APS1012SW
K
P
L
E
T
F
P
I
L
E
T
F
E
T
F
I
J
J
J
U
K
L
P
I
O
K
V
U
O
O
K
C
D
C
B
N
M
M
Q
Q
RV3012OEM
UT2012UL
Q
EMS1250UL
Similar Models: UT750UL, UT1250UL
Included Remote
H
K
P
E
R
Included Remote
D
S
HCRK (90 Amp-Hour Battery)
Similar Models: HCRK-36 (36 Amp-Hour Battery),
HCRK-54 (54 Amp-Hour Battery)
N
USB
Included Battery and Remote
T
Go to www.tripplite.com for additional product photos and ordering information
7
SPECIFICATIONS
Inverter and Inverter/Charger Specifications
Model
Continuous
Output
Rating (1)
Peak
Output
Rating (2)
AC
Outlets
Nominal
DC Voltage
(Range)
Battery
Charger
Capacity
Typical
Transfer
Time (5)
Primary
Housing
Material
Additional Features
Unit
Dimensions
(H x W x D) (7)
Unit
Weight
PowerVerter Portable Inverters (Compact inverters plug into your vehicle’s cigarette lighter or accessory outlet to convert DC battery power to AC household current.)
PV150
150 W
300 W
1
12 V (10-15 V)
–
–
Metal
Auto Plug, Compact/Portable
1.75 x 3.75 x 5.75 in.
1.3 lb
PV375
375 W
600 W
2
12 V (10-15 V)
–
–
Metal
Auto Plug, Compact/Portable
2 x 4.25 x 7 in.
2.3 lb
5.5 lb
PowerVerter Permanent-Mount Inverters (Low-profile inverters mount to flat, stable surfaces.)
PV700HF
700 W
1,400 W
3
12 V (10-15 V)
–
–
Metal
Low-Profile
2.75 x 5 x 11.75 in.
PV1000HF
1,000 W
2,000 W
4
12 V (10-15 V)
–
–
Metal
Low-Profile
4.25 x 6 x 13 in.
6 lb
PV1800HF
1,800 W
3,600 W
4
12 V (10-15 V)
–
–
Metal
Low-Profile
4 x 6 x 15 in.
7.3 lb
PV3000HF
3,000 W
6,000 W
4
12 V (10-15 V)
–
–
Metal
Remote, Low-Profile
4 x 10.5 x 13.5 in.
13.2 lb
PowerVerter Permanent-Mount Inverters with GFCI (GFCI outlets protect against shock in wet or humid environments.)
PV1800GFCI
1,800 W
3,600 W
2 (GFCI)
12 V (10-15 V)
–
–
Metal
GFCI, Low-Profile
4 x 6 x 15 in.
7.3 lb
PV3000GFCI
3,000 W
6,000 W
4 (GFCI)
12 V (10-15 V)
–
–
Metal
GFCI, Remote, Low-Profile
4 x 10.5 x 13.5 in.
13.2 lb
PowerVerter Plus Heavy-Duty Permanent-Mount Inverters (Support demanding inductive loads, such as motors, compressors and pumps.)
PV1250FC
1,250 W
2,500 W
2
12 V (10-15 V)
–
–
Polycarbonate
Heavy-Duty (6)
7 x 8.75 x 9 in.
23.2 lb
PV2000FC
2,000 W
4,000 W
2
12 V (10-15 V)
–
–
Metal/Poly
Heavy-Duty (6)
7.25 x 8.5 x 16.25 in.
39 lb
PV2400FC
2,400 W
4,800 W
2
24 V (20-30 V)
–
–
Polycarbonate
Heavy-Duty (6)
7.25 x 8.5 x 16.25 in.
39 lb
PowerVerter APS General-Purpose Inverter/Chargers (Heavy-duty models support demanding inductive loads, such as motors, compressors and pumps.)
APS700HF
700 W
1,400 W
1
12 V (10-15 V)
6 A
1 cycle
Metal
Low-Profile
2.75 x 5.5 x 12.75 in.
4 lb
APS750
750 W
1,500 W
2
12 V (10-15 V)
20 A
1 cycle
Polycarbonate
Heavy-Duty (6)
7 x 8.75 x 9 in.
17 lb
APS1250
1,250 W
2,500 W
2
12 V (10-15 V)
30 A
1 cycle
Polycarbonate
Heavy-Duty (6)
7 x 8.75 x 9 in.
23.2 lb
APS2012
2,000 W
4,000 W
Hardwire
12 V (10-15 V) 25 or 100 A 1 cycle
Polycarbonate
Heavy-Duty (6)
7.25 x 8.5 x 16.25 in.
40 lb
APS2424
2,400 W
4,800 W
Hardwire
24 V (20-30 V)
14 or 55 A (3)
1 cycle
Polycarbonate
Heavy-Duty (6)
7.25 x 8.5 x 16.25 in.
39 lb
APS2448UL
2,400 W
4,800 W
Hardwire
48 V (40-60 V)
15 A
½ cycle
Polycarbonate
Heavy-Duty (6), Fast Transfer
7.25 x 8.5 x 16.75 in.
38.6 lb
APS3636VR
3,600 W
7,200 W
Hardwire
36 V (30-45 V)
30 A
1 cycle
Polycarbonate
AVR, Remote, Heavy-Duty
7.25 x 8.5 x 16.25 in.
55.8 lb
(3)
PowerVerter APS Sine Wave Inverter/Chargers (Provide pure sine wave output.)
APS1012SW
1,000 W
2,000 W
Hardwire
12 V (10-15 V)
4 to 40 A (4)
½ cycle
Metal
Sine Wave Output, Fast Transfer
7.25 x 7.5 x 18 in.
32.2 lb
APS2012SW
2,000 W
4,000 W
Hardwire
12 V (10-15 V)
6 to 60 A (4)
½ cycle
Metal
Sine Wave Output, Fast Transfer
7.25 x 7.5 x 22 in.
50.6 lb
16 lb
PowerVerter APS RV/Camping Inverter/Chargers (Support demanding inductive loads, such as motors, compressors and pumps.)
RV750ULHW
750 W
1,500 W
Hardwire
12 V (10-15 V)
11 or 45 A (3)
1 cycle
Polycarbonate
Heavy-Duty (6)
7 x 8.75 x 9 in.
RV1012ULHW
1,000 W
2,000 W
Hardwire
12 V (10-15 V)
14 or 55 A (3)
1 cycle
Polycarbonate
Heavy-Duty (6)
7 x 10.5 x 16.25 in.
27 lb
RV1250ULHW
1,250 W
2,500 W
Hardwire
12 V (10-15 V)
14 or 55 A (3)
1 cycle
Polycarbonate
Heavy-Duty (6)
7 x 8.75 x 9 in.
23.3 lb
RV1512UL
1,500 W
3,000 W
Hardwire
12 V (10-15 V)
19 or 75 A (3)
1 cycle
Polycarbonate
Heavy-Duty (6)
8 x 10.5 x 17.5 in.
43.2 lb
MRV2012UL
2,000 W
4,000 W
Hardwire
12 V (10-15 V) 25 or 100 A (3)
1 cycle
Metal/Poly
Heavy-Duty (6)
8 x 10.5 x 17.5 in.
43.2 lb
RV3012OEM
3,000 W
6,000 W
Hardwire
12 V (10-15 V) 35 or 140 A (3)
1 cycle
Metal
Heavy-Duty (6)
9.75 x 11.5 x 16.75 in.
62.6 lb
PowerVerter APS Utility Truck Inverter/Chargers (Support demanding inductive loads. GFCI plug and outlets protect against shock in wet or humid environments.)
UT750UL
750 W
1,500 W
2 (GFCI)
12 V (10-15 V)
11 or 45 A (3)
1 cycle
Polycarbonate
GFCI, Remote, Heavy-Duty (6)
7 x 8.75 x 9 in.
17.4 lb
UT1250UL
1,250 W
2,500 W
2 (GFCI)
12 V (10-15 V)
10 or 40 A (3)
1 cycle
Polycarbonate
GFCI, Remote, Heavy-Duty (6)
7 x 8.75 x 9 in.
23.2 lb
UT2012UL
2,000 W
4,000 W
2 (GFCI)
12 V (10-15 V)
15 or 60 A (3)
1 cycle
Polycarbonate
GFCI, Remote, Heavy-Duty (6)
7.25 x 8.5 x 16.25 in.
40.6 lb
7 x 8.75 x 9 in.
23.2 lb
PowerVerter APS Ambulance/EMS Inverter/Charger (Includes hospital-grade plug and outlets with GFCI. Supports demanding inductive loads.)
EMS1250UL
1,250 W
2,500 W
2 (HG/GFCI)
12 V (10-15 V)
14 or 55 A (3)
1 cycle
Polycarbonate
GFCI, Remote, Heavy-Duty (6)
Medical-Grade Inverter/Chargers (UL 60601-1 for use in patient care areas. Provide pure sine wave output. Include hospital-grade plug and outlets, power and battery modules, remote.)
HCRK
300 W
750 W
3 (HG)
12 V (10-15 V)
10 A
¼ cycle
Metal
HCRK-36
300 W
750 W
3 (HG)
12 V (10-15 V)
10 A
¼ cycle
Metal
HCRK-54
300 W
750 W
3 (HG)
12 V (10-15 V)
10 A
¼ cycle
Metal
UL 60601-1, Sine Wave Output,
Isolation Transformer, Remote,
Fast Transfer, USB Port
11.5 x 6 x 3.5 in. (8)
14.1 lb (8)
11.5 x 6 x 3.5 in. (9)
14.1 lb (9)
11.5 x 6 x 3.5 in. (10)
14.1 lb (10)
1.25 x 4 x 2.25 in. (11)
0.4 lb
1 x 2 x 3.5 in.
0.2 lb
9 x 7 x 10.25 in.
10.5 x 10.5 x 17.75 in.
58 lb
13.5 lb
Inverter and Inverter/Charger Accessories
APSRM4
Remote control module and 50 ft. cord for all Inverter/Charger and Inverter models >700 W, except APS1012SW and APS2012SW.
APSRMSW
Remote control module and 32 ft. cord for APS1012SW and APS2012SW only.
98-121
BP-260
Maintenance-free battery (12 V DC, 75 AH) for all Inverter/Charger models. (24 V, 36 V and 48 V models require multiple batteries.)
Metal battery case with cabling, connectors and terminal isolators for user installation. Holds up to two 98-121 batteries.
All models provide regulated 120 V AC output. All Inverter/Charger models support nominal 120 V AC input. APS700HF, APS750, APS1250, UT750UL, UT1250UL, UT2012UL, EMS1250UL, HCRK, HCRK-36 and HCRK-54 have an
AC input cord and plug. Other Inverter/Charger models have hardwire AC input. Certifications vary with model. (1) Maximum output power available only when connected batteries are properly connected and charged. (2) Peak output
level and duration varies with model, battery condition, charge level, ambient temperature and other factors. Heavy-duty models support up to 150% of continuous output for up to 1 hour and up to 200% of continuous output for up
to 10 seconds. Peak output duration for other models is less. (3) User-selectable. (4) User-selectable range. (5) Typical transfer time from AC line power to battery-derived power during an outage. Most devices, including most
computers and electronics, are compatible with a transfer time of 1 cycle or less. Some devices may require a transfer time of less than 1 cycle to ensure uninterrupted operation when the Inverter/Charger automatically switches
from the AC source to battery power during a power failure. Contact the device manufacturer for more information. At 60 Hz, 1 cycle ≈ 16.667 ms, ½ cycle ≈ 8.333 ms and ¼ cycle ≈ 4.167 ms. (6) Heavy-duty models support
demanding inductive loads, such as motors, compressors and pumps. (7) Unit dimensions are rounded to the nearest ¼ inch. (8) Power module only. Included 90 AH battery module is 14.5 x 8.5 x 7 in. / 61.5 lb. (9) Power module
only. Included 36 AH battery module is 10 x 8.75 x 6.5 in. / 21 lb. (10) Power module only. Included 54 AH battery module is 10 x 8.75 x 6.5 in. / 39 lb. (11) Dimensions without faceplate. Faceplate dimensions are 3.75 x 5.75 in.
Copyright © 2012 Tripp Lite. All trademarks are the property of their respective owners. Tripp Lite has a policy of continuous improvement.
Specifications are subject to change without notice. Photos may differ slightly from actual products.
Tripp Lite World Headquarters
1111 W. 35th Street, Chicago, IL 60609
773.869.1234 • www.tripplite.com
201201092 95-3222
Distributed By: