Product Datasheet

5kW Single-Phase ATS/Metered PDU, 208V Outlets
(16 C13, 2 C19 & 1 L6-30R) 2 L6-30P 10ft inputs, 2U
Rack-Mount, TAA
Highlights
Single phase 30A 208V Auto
Transfer Switch / ATS Metered
PDU with Solid State Switching
Enables redundant-power
MODEL NUMBER: PDUMH30HVAT
configurations for single-corded
network devices
Separate primary & secondary
inputs connect to any two
compatible power sources
2U horizontal rackmount; 2
L6-30P inputs; 19 outlets (16
C13, 2 C19, 1 L6-30R)
Front panel digital display with
LED indicators reports output
amps in 4 loading segments, plus
total kW and input voltage
Trade Agreements Act / TAA
Compliant for GSA Schedule
purchases
Description
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network
Package Includes
devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The
ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary
power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until
the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary
Auto Transfer Switch PDU
Rackmount installation brackets
Installable plug-retention shelves
& cable ties
inputs occurs in 1-5 milliseconds. ATS functionality is supported by any two compatible AC power sources,
regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection
when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the
primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as
the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds
are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when
unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
Features
208V 30A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 24A continuous)
ATS features provide redundant power for critical network equipment with a single input power cord
Digital display with selection button reports voltage, amperage and kilowatt loading information in four output segments (Segment 1: 8 C13 & 1 C19
outlets / Segment 2: 8 C13 & 1 C19 outlets / Segment 3: L6-30R outlet / Segment 4: total output of all outlets combined)
19 built-in outlets (16 C13, 2 C19, 1 L6-30R)
Set of two 10 ft. / 3m NEMA L6-30P input cables support connection to separate PRIMARY and SECONDARY power sources
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to
maintain output as sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord
is connected to a separate UPS system (in a 2 UPS environment, the primary input must be connected to an online double conversion UPS similar to
1/3
Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully
supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower
quality than the primary source
Super-fast switchover between primary and secondary power sources occurs in 1-5 milliseconds
Front panel LEDs confirm power availability on both input lines
Trade Agreements Act / TAA Compliant for GSA Schedule purchases
Specifications
OVERVIEW
PDU Type
Metered; Auto-Transfer Switch
OUTPUT
Output Capacity Details
5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 24A max per L6-30R outlet; 20A max
per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Frequency Compatibility
60 Hz
Output Receptacles
(16) C13; (2) C19; (1) L6-30R
Output Nominal Voltage
200; 208
Overload Protection
Includes two 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19); Breaker 2
controls the lower row of outlets (8 C13, 1 C19); L5-30R outlet is unbreakered
INPUT
PDU Input Voltage
200; 208
Recommended Electrical Service
30A 208V
Maximum Input Amps
30
Maximum Input Amps Details
Agency de-rated to 24A continuous
Input Connection Type
Two labelled NEMA L6-30P cables support Primary and Secondary input connections
PDU Plug Type
NEMA L6-30P
Input Cord Length (ft.)
10
Input Cord Length (m)
3
Input Phase
Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Digital display reports output amps in 4 separately metered loading segments (BANK 1: Outlets #1-9; BANK 2:
Outlets #10-18; BANK 3: Outlet #19), whole-PDU output kW load level and input voltage on primary and secondary
input lines
Front Panel LEDs
Front panel LEDs confirms amp / kilowatt / voltage reporting information
2/3
Switches
ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output and input
voltage (primary, secondary)
PHYSICAL
Minimum Required Rack Depth
(inches)
16
Minimum Required Rack Depth (cm)
40.6
Shipping Dimensions (hwd / in.)
7.8 x 16.7 x 19.5
Shipping Dimensions (hwd / cm)
19.8 x 42.4 x 49.5
Shipping Weight (lbs.)
20.3
Shipping Weight (kg)
9.2
Unit Dimensions (hwd / in.)
3.5 x 17.5 x 12.5
Unit Dimensions (hwd / cm)
8.8 x 44.4 x 31.7
Unit Weight (lbs.)
13.7
Unit Weight (kg)
6.2
Material of Construction
Metal
Form Factors Supported
2U rackmount
PDU Form Factor
Horizontal (1U, 2U, etc)
ENVIRONMENTAL
Storage Temperature Range
5 to 122F (-15 to 50C)
Relative Humidity
5 to 95% (non-condensing)
Operating Elevation (ft.)
0-10,000
Operating Elevation (m)
0-3000
CERTIFICATIONS
Certifications
Tested to UL 60950-1 (USA, Canada), Class A (Emissions), NOM (Mexico), RoHS Complaint, TAA Compliant
WARRANTY
Product Warranty Period (Worldwide)
2-year limited warranty
© 2016 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:
http://www.tripplite.com/products/product-certification-agencies
3/3