Data sheet... SAK Series SAKS 3 Z/6.3X26 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com The fuse terminals of the Weidmüller SAK series are available in two different forms: • Fuse terminal with pivoting retaining lever • Fuse terminal with screwed cap General ordering data Order No. Type Version GTIN (EAN) Qty. 0211120000 SAKS 3 Z/6.3X26 SAK Series, Fuse terminal, Rated cross-section: 10 mm², Screw connection, Direct mounting, TS 32 4008190177331 20 pc(s). Creation date September 11, 2012 12:30:31 PM CEST Catalogue status 23.07.2012 / We reserve the right to make technical changes. 1 Data sheet... SAK Series SAKS 3 Z/6.3X26 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Dimensions Length Height Net weight 54 mm 61 mm 46.35 g Width Height of lowest version -60 °C Storage temperature Continuous operating temp., max. 13 mm 61 mm Temperatures Operating temperature Continuous operating temp., min. 130 °C Rated data IECEx/ATEX Certificate No. (ATEX) ATEX certificate IEC Ex certificate Current (ATEX) Voltage, cross-connection SIRA03ATEX4289U SIRA03ATEX4289U_e.pdf IECEXSIR05.0034U_e.pdf 10 A ATEX certificate Certificate No. (IECEX) Max. voltage (ATEX) Wire cross section max. (ATEX) Operating temperature range Marking ATEX Directive 94/9/EC CrossConnectionGuide.pdf II 2 G D IECEXSIR05.0034U IECEXSIR05.0034U 630 V 10 mm² For operating temperature range see EC Design Test Certificate / IEC ExCertificate of Conformity Additional technical data Explosion-tested version Number of similar terminals Type of mounting No 1 Snap-on Installation advice Open sides Direct mounting right 12400-198 10 A 22 AWG Voltage size C (CSA) Wire cross section max. (CSA) 600 V 10 AWG Stripping length Connection direction Clamping range, rated connection, min. Clamping screw Tightening torque, max. Gauge to IEC 60947-1 12 mm on side 0.33 mm² M4 2.4 Nm CSA ratings data Certificate No. (CSA) Current size C (CSA) Wire cross section min. (CSA) Clampable wires (rated connection) Type of connection Screw connection Blade size 1.0 x 5.5 mm Number of connections 2 Clamping range, rated connection, max. 16 mm² Tightening torque, min. 1.2 Nm Torque level with DMS electric screwdriver 4 Wire connection cross section, solid core, max. rated connection 0.5 mm² Wire connection cross section, stranded, rated connection, min. 1.5 mm² Wire connection cross section, finely stranded, max. 10 mm² Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, rated connection, min. 0.5 mm² Wire connection cross section AWG, min. AWG 22 B6 Wire connection cross section, solid core max. rated connection 16 mm² Wire connection cross section, stranded, rated connection, max. 10 mm² Wire connection cross-section, finely stranded, min. 0.5 mm² Wire connection cross section, finely stranded with wire-end ferrules DIN 46228/1, rated connection, max. 10 mm² Wire connection cross section AWG, max. AWG 10 Creation date September 11, 2012 12:30:31 PM CEST Catalogue status 23.07.2012 / We reserve the right to make technical changes. 2 Data sheet... SAK Series SAKS 3 Z/6.3X26 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Technical data Rated data Rated cross-section Rated impulse withstand voltage Current at maximum wires Rated voltage Rated current Pollution severity Voltage size C (UR) 600 V Conductor size Factory wiring max. (UR) 8 AWG Conductor size Field wiring max. (UR) 8 AWG KrG V-0 Colour Medium yellow SAK Series on side 2 No Yes Type of connection Number of levels No. of clamping points per level Mounting rail Screw connection 1 2 TS 32 AC/DC G-Si. 1 x 1/4 for screw fixing AC/DC Display Operating voltage, max. Without LED 500 V EC000899 27-14-11-16 eClass 6.0 27-14-11-16 10 mm² 6 kV 10 A 500 V 10 A 3 UL ratings data Certificate No. (UR) E60693VOL1SEC10 Current size C (UR) 8A Conductor size Factory wiring min. (UR) 26 AWG Material data Material UL 94 flammability rating System specifications Product family Connection direction Number of connections Levels cross-connected internally End cover plate required Display element Type of voltage for indicator Fuse terminals Cartridge fuse Fuse holder (cartridge holder) Type of voltage for indicator Classifications ETIM 3.0 eClass 7.0 Approvals Approvals Creation date September 11, 2012 12:30:31 PM CEST Catalogue status 23.07.2012 / We reserve the right to make technical changes. 3