Precision Cooling for Business-Critical Continuity Liebert HPM Designed for top level performance and reliability Emerson Network Power, a Division of Emerson, is a global company matching technology and design to supply innovative solutions for its customers’ benefit. Emerson Network Power is the leader in the “business-critical continuity” field thanks to its products and services. Data Center Financial networks Precision Cooling is a key requirement to ensure safe working conditions to datacenters, computer rooms and other equipment that simultaneously need a high sensible heat discharge and a precise temperature and humidity control. Liebert HPM incorporates the whole experience of Emerson Network Power in a unique range of cabinet air coolers suitably designed to ensure performance and reliability. Flexible solutions and low running costs add value to the IT facility. The product Liebert HPM units are cabinet air conditioners. They can feature EC fans, with several air delivery versions: downwards, that is with underfloor delivery, upwards and “displacement”. Liebert HPM units are equipped with iCOM control, featuring an integrated Web connection and two optional graphic display types. Liebert HPM combines different cooling systems for the ideal solution to every facility: • Direct expansion: available with the air or water cooled Copeland Digital Scroll™ compressors. • Chilled water: to be used with Liebert HPC. • Dual-Fluid: matches low running costs and total reliability. It standard operates with chilled water, thus guaranteeing “business-continuity”, thanks to the spare compressors that can intervene in a few seconds, as soon as the central unit stops. • Freecooling: no power consumption if needless. Working 365 days a year, it uses the low winter temperature to cool the rooms, without using compressors. Reliability Performance, equipment protection and fast business re-establishment Design Liebert HPM has been especially designed to achieve top reliability. All components have been sized for the lowest possible stress. Models have been rigorously tested before being launched on the market. The Liebert HPM range is Eurovent certified. Monitoring The Emerson Network Power Monitoring solutions ensure the best control on energy and air conditioning within IT facilities. Communication to all protocols (Modbus, Bacnet, Lonworks, HTTP and SNMP are just a few of the available ones) enables the integration both with the BMS system and with the facility software. The iCOM control device handles the operation of the HPM units, using over twenty years of experience in the development of communication systems and controls. The iCOM control is featured by a special control algorithm, ensuring top reliability under every condition. It directly connects with the facility network (Ethernet) and enables the communication among multiple HPM units for synchronized operations, guaranteeing top reliability and precise room control. Teamwork The HPM unit teamwork within the same room is available thanks to the integrated Ethernet connection. The self-control of redundant units alternates the stand-by positions and gives priority to possible hot areas. control • Several graphic display options • On-line unit log • Integrated Web communication • Preventive maintenance through an advanced troubleshooting • 400 stored events/unit • Up to 16 stored temperature and humidity days Ethernet Flexibility Business-tailored EC fans Copeland Digital Scroll™ Variable speed fans achieve a wide range of air delivery and static pressure. They ensure a correct air distribution even when the facility expands. Copeland Digital Scroll™ compressors combine the sturdiness of scroll compressors with the capacity of operating with varying load. When the traffic managed by the equipment faces sudden changes, the facility experiences thermal load peaks. Further installed devices need a higher cooling capacity. EC fans can increase the air delivery to meet the demand, thanks to the continuous regulation through the iCOM control. Copeland Digital Scroll™ compressors quickly follow the temperature and supply a load-balanced cooling capacity. EC fans can even recover possible unexpected load losses due to new wiring or other elements inside the raised floor. The Copeland Digital Scroll™ technology has no adverse effect on electronic equipment, unlike other solutions. The special EC motors get the best performance vs. AC and DC motors. They do not emit electromagnetic noises, as they do not use power delivered by frequency converters. Further, EC motors feature a consumption about 30% lower than the one by traditional AC motors. Thus, it can be used also in industries and sectors where sensible equipment - such as computers that must not be subject to any EMI - operate. EC fans • AC powered 50/60 Hz without frequency converter • Static pressure continuous adjustment • Energy consumption lower by approx. 30% vs. AC motors • No maintenance • Long life transmission Copeland Digital Scroll™ • Better room control • Energy saving with partial load • Quick adjustment to load changes • Simple and reliable mechanics • AC powered 50/60 Hz without frequency converter • EMC free Ethernet Running cost Keeping profitability Efficiency Compactness Cooling a computer room needs high power. Liebert HPM units take less space thanks to their reduced plan dimensions. Energy efficiency is the top target in Liebert HPM designing. Over-sized heat exchangers and optimized aerodynamics allow one of the lowest energy consumption in the Precision Conditioning Cooling field. The compact design still ensures the best performance thanks to fluido-dynamic analyses and several lab tests. Freecooling Maintenance Freecooling units minimize energy consumption. The handy user interface and the quick front access to mechanical adjustments shorten the routine maintenance time. Working 365 days a year, they use the low winter temperature to cool the rooms, without using compressors. Heat exchange surface • High Energy Efficiency Ratio (EER). It basically depends on the heat exchange surface. Refrigerating circuits consume less energy. • High Sensible Heat ratio (SHR). Sensible heat vs. latent heat. Technological applications require a high sensible heat discharge, without lowering the room humidity too much, as it would need to be restored through a humidifier. Ethernet Leading Precision Cooling Over IP Integrate your Network Management Connectivity and monitoring solutions Whether you have a Network Management System or a BMS and you need to integrate Liebert HPM, this can be simply done through a Web card: SNMP, Modbus, HTTP and Lonworks are just a few of the protocols available. •SNMP •Lonwork •HTTP •Modbus Liebert Sitescan and Hirovisor IP, advanced monitoring solutions that can be offered for both local and remote monitoring either through a dial up line or through internet. IP display Whenever you are in the network you can plug iCOM user interface and browse the connected units thus enabling a first level of monitoring. IP IP IP IP IP IP IP Eth ern et Embedded Ethernet connection Each unit connected to Ethernet can talk to up to 32 units regardless of the distance. Functional schemes A - Air-cooled with remote condenser W- Water-cooled D - Air-cooled Dual-Fluid H - Water-cooled Dual-Fluid F - Freecooling C - Chilled water Combination with condensers Max. outdoor temperature 35° C Standard Low Noise Model Standard Low Noise 1 x HCE07 1 x HCE07 1 x HCE10 1 x HCE14 1 x HCE14 1 x HCE14 1 x HCE24 1 x HCE24 1 x HCE29 1 x HCE29 1 x HCE29 1 x HCE29 2 x HCE24 or 1 x HBE33 1 x HCE 07 1 x HCE 07 1 x HCE 14 1 x HCE 14 1 x HCE 17 1 x HCE 17 1 x HCE 24 1 x HCE 24 1 x HCE 29 1 x HCE 29 1 x HCE 33 1 x HCE 33 2 x HCE 24 M35 A/D M41 A/D M42 A/D 1 x HCE33 1 x HCE42 2 x HCE24 M47 A/D M50 A/D 1 x HCE49 2 x HCE29 or 1 x HBE49 2 x HCE29 or 1 x HBE49 2 x HCE33 2 x HCE 42 or 1 x HBE 87 2 x HCE 49 or 1 x HBE 87 1 x HCE 42 1 x HCE 49 2 x HCE 24 or 1 x HBE 49 1 x HCE 49 2 x HCE 29 Model S04 A S05 A S07 A S10 A S12 A S13 A/D S17 A/D S20 A/D S23 A/D M25 A/D M29 A M31 A/D M34 A/D Max. outdoor temperature 35° C M58 A/D M66 A L83 A/D L99 A 2 x HCE 33 2 x HCE 42 2 xHCE 42 or 1 xHBE 87 2 xHCE 49 or 1 xHBE 99 Combination with Dry Cooler Max. outdoor temperature 35° C Max. outdoor temperature 35° C Model S04W S05W S07W S10W S12W S13W/H/F S17W/H/F S20W/H/F S23W/H/F M25 W/H/F M29 W Standard Low Noise Model 1 x ESM009 1 x ESM009 1 x ESM009 1 x ESM009 1 x ESM013 1 x ESM013 1 x ESM018 1 x ESM022 1 x EST028 1 x EST028 1 x EST028 1 x ELM008 1 x ELM008 1 x ELM008 1 x ELM008 1 x ELM015 1 x ELM015 1 x ELM015 1 x ELM023 1 x ELM027 1 x ELM027 1 x ELM027 M31 W/H/F M34 W/H/F M35 W/H/F M41 W/H/F M42 W/H/F M47 W/H/F M50 W/H/F M58 W/H/F M66 W L83 W/H/F L99 W Standard Low Noise 1 x EST028 1 x EST028 1 x EST028 1 x EST040 1 x EST040 1 x EST050 1 x EST050 1 x EST060 1 x EST070 1 x EST 080 1 x EST 080 1 x ELM027 1 x ELM027 1 x ELM027 1 x ELT040 1 x ELT040 1 x ELT040 1 x ELT047 1 x ELT055 1 x ELT055 1 x ELT 065 1 x ELT 085 Technical data - C - Chilled water Air delivery: downwards or upwards Model S06 S08 S11 S15 S18 S29 M44 M55 M66 M77 L90(6) 6,2 9,2 12,6 17,5 22,4 28,8 43,6 58,6 68,8 83,5 90.7 Total cooling capacity(2) kW Sensible cooling capacity(2) kW 5,6 8,5 11,2 16,7 20,3 25,0 34,7 49,7 56,2 64,8 76.8 Water flow rate(2) l/s 0,30 0,44 0,60 0,83 1,07 1,38 2,08 2,79 3,28 3,71 4.33 n° 1 1 1 1 1 1 1 2 2 2 2 Number of fans m3/h 1395 2200 2800 4500 5200 6150 8150 12740 13650 14220 19060 Air delivery Max. ESP (7) downward/upward delivery Pa 170/190 190/190 30/50 220/220 400/400 180/180 170/170 340/350 250/250 170/190 270 Sound pressure level(5) dB(A) 46,1 48,3 50,5 50,4 51,4 54,5 55.1 58.2 60.3 62.2 58.7 mm 750 750 750 750 750 750 1000 1750 1750 1750 2050 Width mm 400 500 500 750 750 750 850 850 850 850 890 Depth Net weight kg 135 150 165 190 210 230 330 480 550 600 620 L10(6) L12(6) L14(6) L15(6) 103.4 83.9 4.93 2 20400 180 61.0 2050 890 630 117.9 97.4 5.62 3 23100 290 62.1 2550 890 790 142.8 111.7 6.81 3 25100 180 62.1 2550 890 800 158.9 121.5 7.58 3 26070 110 63.8 2550 890 810 Technical data - A/W — Direct expansion, air or water cooled Air delivery: downwards or upwards S04 S05 S07 S10 S12 S13 S17 S20 S23 M25 M29 M31 Total cooling capacity(1) kW 4,6 5,7 8,2 10,6 12,5 14,5 17,3 20,5 26,6 26,5 29,7 31,3 Sensible cooling capacity(1) SHR(1) EER(1)(3) Numberof compressors Number of fans Air delivery Max. ESP(7) downward/upward delivery Sound pressure level(4) Width Depth Net weight kW 4,3 0,93 3,29 1 1 1150 200/250 45,5 750 400 160 5,3 0,93 3,35 1 1 1350 170/180 46,4 750 400 170 7,7 0,94 3,28 1 1 2100 240/240 47,3 750 500 195 10,1 0,95 3,66 1 1 2600 130/130 48,2 750 500 210 11,0 0,88 3,57 1 1 2700 80/80 50,5 750 500 215 13,8 0,95 3,82 1 1 4200 280/280 49,0 750 750 240 16,4 0,95 3,68 1 1 4950 220/220 51,3 750 750 250 19,2 0,94 3,42 1 1 5200 400/400 51,5 750 750 260 23,6 0,89 3,41 1 1 5750 270/270 54,4 750 750 270 24,2 0,91 3,56 1 1 6340 360/380 53.3 1000 850 425 27,2 0,92 3,35 1 1 7080 240/280 55.1 1000 850 430 30,3 0,97 3,51 1 1 8850 360/420 58.5 1750 850 575 M34 M35 M41 M42 M47 M50 M58 M66 L83(6) L99(6) 36,2 34,1 0,94 3,62 2 1 9490 350/350 60.5 1750 850 590 37,0 35,1 0,95 3,58 1 1 9540 340/340 60.4 1750 850 580 45,8 43,4 0,95 3,52 1 2 11230 380/380 58.4 1750 850 600 42,8 41,5 0,97 3,63 2 2 11370 380/390 58.1 1750 850 600 53,7 49,0 0,91 3,45 1 2 12250 300/300 60.4 1750 850 620 54,9 49,3 0,90 3,59 2 2 12240 300/300 59.3 1750 850 635 60,1 52,7 0,88 3,40 2 2 12910 240/250 61.1 1750 850 650 70,3 58,5 0,83 3,49 2 2 13470 170/180 63.4 1750 850 670 86.3 79.5 0.92 3.31 2 2 20020 170 66.2 2550 890 950 104.6 89.3 0.85 3.40 2 2 21100 90 66.9 2550 890 1000 D50 D66 Model n° n° m3/h Pa dB(A) mm mm kg Model (1) Total cooling capacity Sensible cooling capacity(1) SHR(1) EER(1)(3) Numberof compressors Number of fans Air delivery Max. ESP(7) downward/upward delivery Sound pressure level(4) Width Depth Net weight kW kW n° n° m3/h Pa dB(A) mm mm kg Technical Data - A/W - Direct expansion, air or water cooled with Digital Scroll Air Delivery: Downwards or Upwards Model Sel. Condenser (ext. temp up to 40°C) Total cooling capacity(1) Sensible cooling capacity(1) SHR at Full load(1) SHR at 80% load(1) EER at full load (1)(3) EER at 80% load(1)(3) N° of compressors (dig./stand. scroll) Number of fans Air delivery Max. ESP(7) downward/upward delivery Sound pressure level Width Depth Net weight D13 n° n° m3/h Pa dB(A) mm mm kg D17 D20 D23 D25 D34 D35 D42 1xHCE24 1xHCE24 1xHCE33 1xHCE42 1xHCE42 2xHCE24 1xHCE42 2xHCE33 2xHCE42 2xHCE42 14,70 17,30 20,50 25,80 25,80 34,90 34,80 42,40 51,20 66,00 13,90 16,30 19,20 23,20 24,00 33,70 34,20 41,50 47,40 56,70 0,95 0,94 0,94 0,90 0,93 0,97 0,98 0,97 0,93 0,86 1,00 1,00 1,00 0,97 1,00 1,00 1,00 1,00 1,00 0,95 3,30 2,99 2,78 3,03 3,16 2,97 2,92 3,00 3,02 2,83 3,22 3,00 2,78 2,93 3,08 2,96 2,84 2,96 2,92 2,80 1 1 1 1 1 1/1 1 1/1 1/1 1/1 1 1 1 1 1 1 1 2 2 2 4200 4950 5200 5750 6340 9490 9540 11370 12240 13470 280 220 400 270 360/380 350 340 380/390 300 170/180 49 51,3 51,5 54,4 53,3 60,5 60,4 58,1 59,3 63,4 750 750 750 750 1000 1750 1750 1750 1750 1750 750 750 750 750 850 850 850 850 850 850 240 250 260 270 425 590 580 600 635 670 Technical data - C - Chilled water Air delivery: downwards or upwards Model Total cooling capacity(2) Sensible cooling capacity(2) Water flow rate(2) Number of fans Air delivery Max. ESP (7) downward/upward delivery Sound pressure level(5) Width Depth Net weight kW kW l/s n° m3/h Pa dB(A) mm mm kg L16(6) (8) L18(6) (8) L20(6) (8) 175,0 134,6 8,35 3 29600 100 66,5 2550 890 940 206,8 159,9 9,86 4 35410 100 68,5 3350 890 1000 232,2 172,3 11,07 4 35650 100 68,6 3350 890 1085 Available versions Version S04 S05 S06 S07 S08 S10 S11 S12 S13 / D13 S15 S17 / D17 S18 S20 / D20 S23 / D23 S29 M25 / D25 M29 M31 M34 / D34 M35 / D35 M41 M42 / D42 M44 M47 M50 / D50 M55 M58 M66 / D66 M77 L83 L90 L99 L10 L12 L14 L15 L16 L18 L20 A/W - - - - - - - - - - - - - - - - - - - - - - - - - C - Downward air delivery Displacement F/D/H - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Upward air delivery Front air delivery Constant - - - - - Downwards Air Delivery - Displacement Upwards Air Delivery Front Air Delivery A/W: Direct expansion, air or water cooled F/D/H: Free-cooling e Dualfluid C: Freecooling and Dual-Fluid Constant version: See the product manual Constant Models: Available on units with standard scroll (1) 24°C db, 50% R.H.; 45°C condensation (selected condenser and 35°C outdoor temp with HPM Digital models); refrigerant R407C (2) 24°C db, 50% R.H.; 7/12°C water inlet/outlet. (3) 20 Pa ESP, downward delivery version. 50 Pa upward delivery version (4) 1.5 m height, 2 m front distance; free field; compressor(s) and fan (s) working. Downward delivery version (5) 1.5 m height, 2 m front distance; free field; fan (s) working. Downward delivery version. (6) Available only in the Down- ward delivery version (7) Max. ESP available for the indicated air delivery (8) sizes L16-L18-L20 are supplied with EC fans as standard (9) all units height is 1950 mm except L16-L20 with 2150 mm height Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™. The company is the trusted source for custom, adaptive and ultra-reliable solutions that enable and protect its customers’ business-critical technology infrastructures. Backed by the largest global services organization in the industry, Emerson Network Power offers a full range of innovative power, precision cooling, connectivity and embedded products and services for computer, communications, healthcare and industrial systems. Key product brands within the Emerson Network Power family include Liebert, Knürr, ASCO, Astec, Lorain. Locations Emerson Network Power - Headquarters EMEA Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 5841 257 [email protected] Emerson Network Power - Service EMEA Via Leonardo Da Vinci 16/18 Zona Industriale Tognana 35028 Piove di Sacco (PD) Italy Tel: +39 049 9719 111 Fax: +39 049 9719045 [email protected] United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Tel: +1 614 8880246 Asia 7/F, Dah Sing Financial Centre 108 Gloucester Road, Wanchai Hong Kong Tel: +852 2572220 Fax: +852 28029250 While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2009 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. 103027 Emerson Network PowerTM. www.eu.emersonnetworkpower. com The global leader in enabling Business-Critical Continuity™. [email protected] AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Out Side Plant Power Switching & Controls Precision Cooling Rack & Integrated Cabinets Services Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co.