data sheet - family

Photoelectric sensors
FADH 14 (current output)
Distance sensors
sample drawing
LED
34,3
REF
40
96,8
* 18,9
52,2
19,6
ø 17
* emitter axis
general data
sample picture
measuring distance Sd
50 ... 400 mm
special type
hygienic design
adjustment
IO-Link
Teach-in range min.
> 20 mm
power on indication
LED green
soiled lens indicator
LED red
resolution
0,1 ... 1 mm
linearity error
± 1,5 ... ± 4 mm
light source
pulsed point source LED
wave length
660 nm
beam type
point
beam diameter
8 mm
temperature drift
< 0,1 % Sde/K
approvals/certificates
Ecolab
EHEDG
electrical data
response time / release time
< 3 ms
voltage supply range +Vs
12 ... 26 VDC
current consumption max. (no load)
80 mA
output circuit
analog
output signal
4 ... 20 mA
load resistance (analog I)
< (+Vs - 10 V) / 0,02 A
output current
< 100 mA
alarm output
push-pull
short circuit protection
yes
reverse polarity protection
yes, Vs to GND
mechanical data
width / diameter
19,6 mm
height / length
52,2 mm
depth
34,3 mm
type
rectangular
housing material
stainless steel 1.4404 (V4A)
front (optics)
PMMA
ambient conditions
operating temperature
0 ... +50 °C
protection class
IP 68/69K & proTect+
1
www.baumer.com
30/11/2015
Photoelectric sensors
FADH 14 (current output)
Distance sensors
order reference
connection types
FADH 14I4470/IO
cable 4 pin, 2 m
FADH 14I4470/KS34A/IO
flylead connector M12, L=300 mm
2
www.baumer.com