Photoelectric sensors FADH 14 (current output) Distance sensors sample drawing LED 34,3 REF 40 96,8 * 18,9 52,2 19,6 ø 17 * emitter axis general data sample picture measuring distance Sd 50 ... 400 mm special type hygienic design adjustment IO-Link Teach-in range min. > 20 mm power on indication LED green soiled lens indicator LED red resolution 0,1 ... 1 mm linearity error ± 1,5 ... ± 4 mm light source pulsed point source LED wave length 660 nm beam type point beam diameter 8 mm temperature drift < 0,1 % Sde/K approvals/certificates Ecolab EHEDG electrical data response time / release time < 3 ms voltage supply range +Vs 12 ... 26 VDC current consumption max. (no load) 80 mA output circuit analog output signal 4 ... 20 mA load resistance (analog I) < (+Vs - 10 V) / 0,02 A output current < 100 mA alarm output push-pull short circuit protection yes reverse polarity protection yes, Vs to GND mechanical data width / diameter 19,6 mm height / length 52,2 mm depth 34,3 mm type rectangular housing material stainless steel 1.4404 (V4A) front (optics) PMMA ambient conditions operating temperature 0 ... +50 °C protection class IP 68/69K & proTect+ 1 www.baumer.com 30/11/2015 Photoelectric sensors FADH 14 (current output) Distance sensors order reference connection types FADH 14I4470/IO cable 4 pin, 2 m FADH 14I4470/KS34A/IO flylead connector M12, L=300 mm 2 www.baumer.com 30/11/2015