Philips Semiconductors Product Specification Silicon Bi-directional Trigger Device GENERAL DESCRIPTION BR100/03 LLD QUICK REFERENCE DATA Silicon bidirectional trigger device in a glass envelope suitable for surface mounting. The device is intended for use in triac and thyristor trigger circuits. SYMBOL PARAMETER V(BO) VO IFRM Breakover voltage Output voltage Repetitive peak forward current OUTLINE - SOD80 MIN. MAX. UNIT 28 7 - 36 2 V V A SYMBOL LIMITING VALUES Limiting values in accordance with the Absolute Maximum System (IEC 134). SYMBOL PARAMETER CONDITIONS IFRM Repetitive peak forward current Total power dissipation Storage temperature Operating junction temperature t ≤ 10 µs, Ttp ≤ 50˚C; f = 60 Hz Ptot Tstg Tj Ttp = 50˚C MIN. MAX. UNIT - 2 A -55 - 150 125 100 mW ˚C ˚C THERMAL RESISTANCES SYMBOL PARAMETER Rth j-tp Thermal resistance junction to PCB mounted tie point CONDITIONS MIN. TYP. - 330 MIN. TYP. MAX. UNIT - K/W CHARACTERISTICS Ta = 25 ˚C unless otherwise stated. SYMBOL PARAMETER CONDITIONS V(BO) |V(BO)+| - |V(BO)-| VO I(BO) dV(BO)/dT Breakover voltage Breakover voltage symmetry Output voltage Breakover current Temperature coefficient of V(BO) Risetime I = I(BO) I = I(BO), see fig: 1 RL = 20 Ω; Circuit of fig: 2 V = V(BO) 28 7 - 32 0.1 Ip = 0.5 A; Circuit of fig: 2 - 1.5 tr February 1996 1 MAX. UNIT 36 3.5 50 - V V V µA %/K µs Rev 1.000 Philips Semiconductors Product Specification Silicon Bi-directional Trigger Device BR100/03 LLD I VBO D.U.T. IT 500k 10k I(BO)I V(BO)III V(BO)I 100nF V 230 V, RMS, 50Hz I(BO)III 10R Set load resistance to 20 Ohms when measuring output voltage Vo 50R Adjust for Ip=0.5A when measuring risetime Fig.1. Current-voltage characteristics Fig.2. Test circuit for output voltage and risetime. MECHANICAL DATA Dimensions in mm 0 1.5 1.3 0 1.5 max 0.3 min 3.7 3.3 Fig.3. SOD80 February 1996 2 Rev 1.000 Philips Semiconductors Product Specification Silicon Bi-directional Trigger Device BR100/03 LLD DEFINITIONS Data sheet status Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications. Limiting values Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of this specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. Philips Electronics N.V. 1996 All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, it is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights. LIFE SUPPORT APPLICATIONS These products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale. February 1996 3 Rev 1.000