IRF 35SCGQ060

PD -94275B
35SCGQ060
SCHOTTKY RECTIFIER
HIGH EFFICIENCY SERIES
35 Amp, 60V
Major Ratings and Characteristics
Characteristics
Description/Features
The 35SCGQ060 center tap Schottky rectifier has been
expressly designed to meet the rigorous requirements of
hirel environments. It is packaged in the hermetic isolated
TO-254AA package. The device's forward voltage drop
and reverse leakage current are optimized for the lowest
power loss and the highest circuit efficiency for typical high
frequency switching power supplies and resonent power
converters. Full MIL-PRF-19500 quality conformance
testing is available on source control drawings to
TX, TXV and S quality levels.
35SCGQ060 Units
IF(AV)
35
A
VRRM (Per Leg)
60
V
IFSM @ tp = 8.3ms half-sine
(Per Leg)
400
A
VF @ 17.5Apk, TJ =125°C
(Per Leg)
0.61
V
TJ, Tstg Operating and storage -55 to 150
CASE STYLE
•
•
•
•
•
Hermetically Sealed
Center Tap
Low Forward Voltage Drop
High Frequency Operation
Guard Ring for Enhanced Ruggedness and Long term
Reliability
• Lightweight
°C
0.12 [.005]
6.60 [.260]
6.32 [.249]
13.84 [.545]
13.59 [.535]
3.78 [.149]
3.53 [.139]
1.27 [.050]
1.02 [.040]
A
20.32 [.800]
20.07 [.790]
17.40 [.685]
16.89 [.665]
1
C
2
3
17.40 [.685]
16.89 [.665]
3X
3.81 [.150]
2X
B
13.84 [.545]
13.59 [.535]
0.84 [.033]
MAX.
1.14 [.045]
0.89 [.035]
0.36 [.014]
3.81 [.150]
B A
NOT ES:
1.
2.
3.
4.
DIMENSIONING & TOLERANCING PER ASME Y14.5M-1994.
ALL DIMENS IONS ARE SHOWN IN MILLIMET ERS [INCHES].
CONT ROLLING DIMENS ION: INCH.
T HIS OUT LINE IS A MODIFIED T O-254AA JEDEC OUTLINE.
1
2
3
ANODE COMMONANODE
CATHODE
Case Outline and Dimensions - TO-254AA
www.irf.com
1
05/06/04
35SCGQ060
Voltage Ratings
Part number
VR
35SCGQ060
Max. DC Reverse Voltage (V) (Per Leg)
60
VRWM Max. Working Peak Reverse Voltage (V) (Per Leg)
Absolute Maximum Ratings
Parameters
IF(AV) Max. Average Forward Current
Limits
Units
35
A
50% duty cycle @ TC =113 °C, square waveform
Conditions
400
A
@ tp = 8.3 ms half-sine
Limits
Units
0.64
V
@ 17.5A
0.82
V
@ 35A
See Fig. 5
IFSM
Max. Peak One Cycle Non - Repetitive
Surge Current (Per Leg)
Electrical Specifications
Parameters
VFM
Max. Forward Voltage Drop
(Per Leg) See Fig. 1
I RM
Max. Reverse Leakage Current
(Per Leg) See Fig. 2
Conditions
0.61
V
@ 17.5A
0.86
V
@ 35A
TJ = -55°C
TJ = 25°C
0.61
V
@ 17.5A
0.93
V
@ 35A
0.22
mA
40
mA
TJ = 100°C
180
mA
TJ = 125°C
VR = 5VDC ( 1MHz, 25°C )
CT
Max. Junction Capacitance (Per Leg)
1520
pF
LS
Typical Series Inductance (Per Leg)
7.8
nH
TJ = 125°C
TJ = 25°C
VR = rated VR
Measured from anode lead to cathode lead
6mm ( 0.025 in.) from package
Thermal-Mechanical Specifications
Parameters
Limits Units
Conditions
TJ
Max.Junction Temperature Range
-55 to 150
Tstg
Max. Storage Temperature Range
-55 to 150
°C
1.25
°C/W
DC operation
0.63
°C/W
DC operation
RthJC Max. Thermal Resistance, Junction
°C
See Fig. 4
to Case (Per Leg)
RthJC Max. Thermal Resistance, Junction
to Case (Per Package)
wt
Weight (Typical)
Die Size (Typical)
Case Style
9.3
150X180
g
mils
TO-254AA
 Pulse Width < 300µs, Duty Cycle < 2%
2
www.irf.com
35SCGQ060
1000
125°C
Reverse Current - I R ( mA )
100
100
100°C
10
75°C
1
0.1
25°C
0.01
0.001
0
10
20
30
40
50
60
Fig. 2 - Typical Values of Reverse Current
Vs. Reverse Voltage (Per Leg)
10
10000
Tj = 125°C
Tj = 25°C
Tj = -55°C
1
0.0
0.2
0.4
0.6
0.8
1.0
Forward Voltage Drop - V F (V)
Fig. 1 - Max. Forward Voltage Drop Characteristics
(Per Leg)
Junction Capacitance - CT (pF)
Instantaneous Forward Current - I F (A)
Reverse Voltage - V R (V)
T J = 25°C
1000
100
0
10
20
30
40
50
60
Reverse Voltage -VR (V)
Fig. 3 - Typical Junction Capacitance Vs.
Reverse Voltage (Per Leg)
www.irf.com
3
35SCGQ060
Thermal Response (Z thJC )
10
1
D = 0.50
0.20
0.10
0.1
P DM
0.05
t1
0.02
0.01
SINGLE PULSE
(THERMAL RESPONSE)
t2
Notes:
1. Duty factor D = t 1 / t 2
2. Peak TJ = P DM x Z thJC + TC
0.01
0.00001
0.0001
0.001
0.01
0.1
1
t1 , Rectangular Pulse Duration (sec)
Fig. 4 - Max. Thermal Impedance ZthJC Characteristics (Per Leg)
180
35SCGQ060
Allowable Case Temprature - (°C)
160
R thJC = 0.63°C/W
140
120
DC
100
80
60
40
20
0
0
10
20
30
40
50
60
Average Forward Current - I F(AV) (A)
Fig. 5 - Max. Allowable Case Temperature Vs.
Average Forward Current
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR LEOMINSTER: 205 Crawford St., Leominster, Massachusetts 01453, Tel: (978) 534-5776
Data and specifications subject to change without notice.
05/2004
4