1 3 TO -24 7 2 1 - Anode 1 2 - Common Cathode Back of Case - Cathode 3 - Anode 2 APT30D30BCT(G) 300V 2X30A *G Denotes RoHS Compliant, Pb Free Terminal Finish. 1 2 3 ULTRAFAST SOFT RECOVERY RECTIFIER DIODE PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS • Parallel Diode • Ultrafast Recovery Times • Low Losses • Soft Recovery Characteristics • Low Noise Switching • Popular TO-247 Package • Cooler Operation • Low Forward Voltage • Higher Reliability Systems • High Blocking Voltage • Increased System Power • • • • • -Switchmode Power Supply -Inverters Free Wheeling Diode -Motor Controllers -Converters Snubber Diode Uninterruptible Power Supply (UPS) Induction Heating High Speed Rectifiers • Low Leakage Current MAXIMUM RATINGS Symbol VR Density All Ratings Are Per Leg: TC = 25°C unless otherwise specified. Characteristic / Test Conditions APT30D30BCT(G) Maximum D.C. Reverse Voltage VRRM Maximum Peak Repetitive Reverse Voltage VRWM Maximum Working Peak Reverse Voltage IF(AV) Maximum Average Forward Current (TC = 119°C, Duty Cycle = 0.5) 30 RMS Forward Current (Square wave, 50% duty) 70 IF(RMS) IFSM TJ,TSTG TL UNIT 300 Volts Amps 320 Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms) -55 to 150 Operating and StorageTemperature Range °C 300 Lead Temperature for 10 Sec. STATIC ELECTRICAL CHARACTERISTICS Forward Voltage IRM Maximum Reverse Leakage Current CT Junction Capacitance, VR = 200V TYP MAX IF = 30A 1.2 1.4 IF = 60A 1.5 IF = 30A, TJ = 125°C 1.0 Volts VR = VR Rated 250 VR = VR Rated, TJ = 125°C 500 APT Website - http://www.advancedpower.com 80 UNIT µA 1-2004 VF MIN pF 053-3003 Rev C Symbol DYNAMIC CHARACTERISTICS APT30D30BCT Characteristic Symbol Test Conditions MIN TYP MAX UNIT trr Reverse Recovery Time I = 1A, di /dt = -100A/µs, V = 30V, T = 25°C F F R J - 20 trr Reverse Recovery Time - 25 Qrr Reverse Recovery Charge - 28 - 2 - 55 ns - 150 nC - 5 - 33 ns - 300 nC - 16 Amps MIN TYP IRRM IF = 30A, diF/dt = -200A/µs VR = 200V, TC = 25°C Maximum Reverse Recovery Current trr Reverse Recovery Time Qrr IF = 30A, diF/dt = -200A/µs Reverse Recovery Charge IRRM VR = 200V, TC = 125°C Maximum Reverse Recovery Current trr Reverse Recovery Time Qrr IF = 30A, diF/dt = -800A/µs Reverse Recovery Charge IRRM VR = 200V, TC = 125°C Maximum Reverse Recovery Current ns nC - - Amps Amps THERMAL AND MECHANICAL CHARACTERISTICS Symbol Characteristic / Test Conditions MAX RθJC Junction-to-Case Thermal Resistance .67 RθJA Junction-to-Ambient Thermal Resistance 40 °C/W WT 0.22 oz 5.9 g Package Weight Torque 10 lb•in 1.1 N•m Maximum Mounting Torque APT Reserves the right to change, without notice, the specifications and information contained herein. 0.9 0.60 0.50 0.7 0.40 0.5 Note: 0.30 PDM Z JC, THERMAL IMPEDANCE (°C/W) θ 0.70 0.3 0.20 0.10 Duty Factor D = t1/t2 0.1 SINGLE PULSE 0.05 10-5 10-4 Peak TJ = PDM x ZθJC + TC 10-3 10-2 10-1 1.0 RECTANGULAR PULSE DURATION (seconds) FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION RC MODEL Junction temp (°C) 1-2004 t1 t2 0 053-3003 Rev C UNIT 0.289 °C/W 0.00448 J/°C 0.381 °C/W 0.120 J/°C Power (watts) Case temperature (°C) FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL APT30D30BCT(G) TYPICAL PERFORMANCE CURVES 60 80 60 TJ = 150°C 40 TJ = 125°C TJ = 25°C 20 trr, REVERSE RECOVERY TIME (ns) IF, FORWARD CURRENT (A) 100 TJ = 125°C VR = 200V 15A 50 30A 60A 40 30 20 10 TJ = -55°C 0 0 0 0.05 1 1.5 2 VF, ANODE-TO-CATHODE VOLTAGE (V) Figure 2. Forward Current vs. Forward Voltage 0 200 400 600 800 1000 -diF /dt, CURRENT RATE OF CHANGE(A/µs) Figure 3. Reverse Recovery Time vs. Current Rate of Change 18 TJ = 125°C VR = 200V IRRM, REVERSE RECOVERY CURRENT (A) Qrr, REVERSE RECOVERY CHARGE (nC) 350 60A 300 250 30A 200 15A 150 100 50 0 0 200 400 600 800 1000 -diF /dt, CURRENT RATE OF CHANGE (A/µs) Figure 4. Reverse Recovery Charge vs. Current Rate of Change 15A 12 10 30A 8 6 4 2 0 200 400 600 800 1000 -diF /dt, CURRENT RATE OF CHANGE (A/µs) Figure 5. Reverse Recovery Current vs. Current Rate of Change trr 1.0 trr 0.8 IRRM 0.6 Qrr 0.4 Duty cycle = 0.5 TJ = 150°C 70 Qrr 60 IF(AV) (A) Kf, DYNAMIC PARAMETERS (Normalized to 800A/µs) 14 80 1.2 60A 0 1.4 50 40 30 20 0.2 0.0 TJ = 125°C VR = 200V 16 10 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (°C) Figure 6. Dynamic Parameters vs. Junction Temperature 0 25 50 75 100 125 150 Case Temperature (°C) Figure 7. Maximum Average Forward Current vs. CaseTemperature 500 400 1-2004 300 200 100 0 .1 1 10 100 200 VR, REVERSE VOLTAGE (V) Figure 8. Junction Capacitance vs. Reverse Voltage 053-3003 Rev C CJ, JUNCTION CAPACITANCE (pF) 600 APT30D30BCT(G) Vr diF /dt Adjust +18V APT30M75B2LL 0V D.U.T. 30µH trr/Qrr Waveform PEARSON 2878 CURRENT TRANSFORMER Figure 9. Diode Test Circuit 1 IF - Forward Conduction Current 2 diF /dt - Rate of Diode Current Change Through Zero Crossing. 3 IRRM - Maximum Reverse Recovery Current. 4 trr - Reverse Recovery Time, measured from zero crossing where diode current goes from positive to negative, to the point at which the straight line through IRRM and 0.25 IRRM passes through zero. 5 1 4 Zero 5 3 2 Qrr - Area Under the Curve Defined by IRRM and trr. Figure 10, Diode Reverse Recovery Waveform and Definitions TO-247 Package Outline 4.69 (.185) 5.31 (.209) 1.49 (.059) 2.49 (.098) e1 SAC: Tin, Silver, Copper 15.49 (.610) 16.26 (.640) 6.15 (.242) BSC Common Cathode 20.80 (.819) 21.46 (.845) 3.55 (.138) 3.81 (.150) 4.50 (.177) Max. 1-2004 0.40 (.016) 0.79 (.031) 053-3003 Rev C 5.38 (.212) 6.20 (.244) 1.65 (.065) 2.13 (.084) 19.81 (.780) 20.32 (.800) 1.01 (.040) 1.40 (.055) 2.21 (.087) 2.59 (.102) 2.87 (.113) 3.12 (.123) 5.45 (.215) BSC 2-Plcs. Dimensions in Millimeters and (Inches) Anode 1 Common Cathode Anode 2 0.25 IRRM