DISCRETE SEMICONDUCTORS DATA SHEET BGD602 CATV amplifier module Product specification File under Discrete Semiconductors, SC16 Philips Semiconductors February 1994 Philips Semiconductors Product specification CATV amplifier module FEATURES BGD602 PINNING - SOT115J • Excellent linearity PIN DESCRIPTION • Extremely low noise 1 input • Silicon nitride passivation 2 common • Rugged construction 3 common • Gold metallization ensures excellent reliability. 5 +VB 7 common 8 common 9 output DESCRIPTION fpage 1 2 8 5 7 9 3 Side view MSA319 Fig.1 Simplified outline. Hybrid high dynamic range amplifier module designed for applications in CATV systems with a bandwidth of 40 to 600 MHz operating with a voltage supply of 24 V (DC). QUICK REFERENCE DATA SYMBOL PARAMETER power gain Gp Itot CONDITIONS MIN. MAX. UNIT f = 50 MHz 18 19 dB f = 600 MHz 19 − dB − 435 mA total current consumption (DC) VB = 24 V LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 134). SYMBOL PARAMETER MIN. MAX. UNIT Vi RF input voltage − 65 dBmV Tstg storage temperature −40 +100 °C Tmb operating mounting base temperature −20 +100 °C February 1994 2 Philips Semiconductors Product specification CATV amplifier module BGD602 CHARACTERISTICS Bandwidth 40 to 600 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω. SYMBOL PARAMETER Gp power gain SL slope cable equivalent FL S11 S22 CONDITIONS MIN. MAX. UNIT f = 50 MHz 18 19 dB f = 600 MHz 19 − dB f = 40 to 600 MHz 0.2 2.2 dB flatness of frequency response f = 40 to 600 MHz − ±0.3 dB input return losses f = 40 to 80 MHz 20 − dB f = 80 to 160 MHz 19 − dB f = 160 to 600 MHz 18 − dB f = 40 to 80 MHz 20 − dB f = 80 to 160 MHz 19 − dB f = 160 to 600 MHz 18 − dB output return losses S21 phase response f = 50 MHz −45 +45 deg CTB composite triple beat 85 channels flat; Vo = 44 dBmV; measured at 595.25 MHz − −62 dB Xmod cross modulation 85 channels flat; Vo = 44 dBmV; measured at 55.25 MHz − −66 dB CSO composite second order distortion 85 channels flat; Vo = 44 dBmV; measured at 596.5 MHz − −60 dB d2 second order distortion note 1 − −70 dB Vo output voltage dim = −60 dB; note 2 63 − dBmV F noise figure f = 600 MHz − 8 dB Itot total current consumption (DC) note 3 − 435 mA Notes 1. fp = 55.25 MHz; Vp = 44 dBmV; fq = 541.25 MHz; Vq = 44 dBmV; measured at fp + fq = 596.5 MHz. 2. Measured according to DIN45004B: fp = 590.25 MHz; Vp = Vo; fq = 597.25 MHz; Vq = Vo −6 dB; fr = 599.25 MHz; Vr = Vo −6 dB; measured at fp + fq − fr = 588.25 MHz. 3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V. February 1994 3 Philips Semiconductors Product specification CATV amplifier module BGD602 CHARACTERISTICS Bandwidth 40 to 550 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω. SYMBOL PARAMETER Gp power gain SL slope cable equivalent FL S11 S22 CONDITIONS MIN. MAX. UNIT f = 50 MHz 18 19 dB f = 550 MHz 18.8 − dB f = 40 to 550 MHz 0.2 2.2 dB flatness of frequency response f = 40 to 550 MHz − ±0.3 dB input return losses f = 40 to 80 MHz 20 − dB f = 80 to 160 MHz 19 − dB f = 160 to 550 MHz 18 − dB f = 40 to 80 MHz 20 − dB f = 80 to 160 MHz 19 − dB f = 160 to 550 MHz 18 − dB output return losses S21 phase response f = 50 MHz −45 +45 deg CTB composite triple beat 77 channels flat; Vo = 44 dBmV; measured at 547.25 MHz − −66 dB Xmod cross modulation 77 channels flat; Vo = 44 dBmV; measured at 55.25 MHz − −68 dB CSO composite second order distortion 77 channels flat; Vo = 44 dBmV; measured at 548.5 MHz − −62 dB d2 second order distortion note 1 − −72 dB Vo output voltage dim = −60 dB; note 2 64 − dBmV F noise figure f = 550 MHz − 7.5 dB Itot total current consumption (DC) note 3 − 435 mA Notes 1. fp = 55.25 MHz; Vp = 44 dBmV; fq = 493.25 MHz; Vq = 44 dBmV; measured at fp + fq = 548.5 MHz. 2. Measured according to DIN45004B: fp = 540.25 MHz; Vp = Vo; fq = 547.25 MHz; Vq = Vo −6 dB; fr = 549.25 MHz; Vr = Vo −6 dB; measured at fp + fq − fr = 538.25 MHz. 3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V. February 1994 4 Philips Semiconductors Product specification CATV amplifier module BGD602 CHARACTERISTICS Bandwidth 40 to 450 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω. SYMBOL PARAMETER Gp power gain SL slope cable equivalent FL S11 S22 CONDITIONS MIN. MAX. UNIT f = 50 MHz 18 19 dB f = 450 MHz 18.6 − dB f = 40 to 450 MHz 0.2 1.8 dB flatness of frequency response f = 40 to 450 MHz − ±0.3 dB input return losses f = 40 to 80 MHz 20 − dB f = 80 to 160 MHz 19 − dB f = 160 to 450 MHz 18 − dB f = 40 to 80 MHz 20 − dB f = 80 to 160 MHz 19 − dB f = 160 to 450 MHz 18 − dB output return losses S21 phase response f = 50 MHz −45 +45 deg CTB composite triple beat 60 channels flat; Vo = 46 dBmV; measured at 445.25 MHz − −67 dB Xmod cross modulation 60 channels flat; Vo = 46 dBmV; measured at 55.25 MHz − −66 dB CSO composite second order distortion 60 channels flat; Vo = 46 dBmV measured at 446.5 MHz − −60 dB d2 second order distortion note 1 − −75 dB Vo output voltage dim = −60 dB; note 2 67 − dBmV F noise figure f = 450 MHz − 7 dB Itot total current consumption (DC) note 3 − 435 mA Notes 1. fp = 55.25 MHz; Vp = 46 dBmV; fq = 391.25 MHz; Vq = 46 dBmV; measured at fp + fq = 446.5 MHz. 2. Measured according to DIN45004B: fp = 440.25 MHz; Vp = Vo; fq = 447.25 MHz; Vq = Vo −6 dB; fr = 449.25 MHz; Vr = Vo −6 dB; measured at fp + fq − fr = 438.25 MHz. 3. The module normally operates at VB = 24 V, but is able to withstand supply transients up to 30 V. February 1994 5 Philips Semiconductors Product specification CATV amplifier module BGD602 DEFINITIONS Data sheet status Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. LIFE SUPPORT APPLICATIONS These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale. February 1994 6