NSC CLC018

CLC018
8 x 8 Digital Crosspoint Switch, 1.485 Gbps
General Description
Features
The CLC018 is a fully differential 8x8 digital crosspoint
switch capable of operating at data rates exceeding 1.485
Gbps per channel. Its non-blocking architecture utilizes eight
independent 8:1 multiplexers to allow each output to be
independently connected to any input and any input to be
connected to any or all outputs. Additionally, each output can
be individually disabled and set to a high-impedance state.
This TRI-STATE feature allows flexible expansion to larger
switch array sizes.
Low channel-to-channel crosstalk allows the CLC018 to provide superior all-hostile jitter of 50 psPP. This excellent signal
fidelity along with low power consumption of 850 mW make
the CLC018 ideal for digital video switching plus a variety of
data communication and telecommunication applications.
The fully differential signal path provides excellent noise
immunity, and the I/Os support ECL and PECL logic levels.
In addition, the inputs may be driven single-ended or differentially and accept a wide range of common mode levels
including the positive supply. Single +5V or −5V supplies or
dual +5V supplies are supported. Dual supply mode allows
the control signals to be referenced to the positive supply
(+5V) while the high-speed I/O remains ECL compatible.
The double row latch architecture utilized in the CLC018
allows switch reprogramming to occur in the background
during operation. Activation of the new configuration occurs
with a single “configure” pulse. Data integrity and jitter performance on unchanged outputs are maintained during reconfiguration. Two reset modes are provided. Broadcast
reset results in all outputs being connected to input port DI0.
TRI-STATE Reset results in all outputs being disabled.
The CLC018 is fabricated on a high-performance BiCMOS
process and is available in a 64-lead plastic quad flat pack
(PQFP).
n Supports SMPTE 259M, SMPTE 344M, and SMPTE
292M
n Fully differential signal path
n Non-Blocking
n Flexible expansion to larger array sizes with very low
power
n Single +5/−5V or dual ± 5V operation
n TRI-STATE outputs
n Double row latch architecture
n 64-lead PQFP package
Applications
n
n
n
n
n
n
n
Routing switchers
Production switchers
Master control switchers
Telecom/datacom switchers
Storage Area Network (SAM)
Packet switching
ATM SONET
Key Specifications
n High speed: > 1.485 Gbps
n Low jitter:
< 50 psPP for rates < 500 Mbps
< 100 ps PP for rates < 1.485 Gbps
n Low power; 850 mW with all outputs active
n Fast output edge speeds: 250 ps
CLC018 Block Diagram
10008801
10008802
© 2006 National Semiconductor Corporation
DS100088
www.national.com
CLC018 8 x 8 Digital Crosspoint Switch, 1.485 Gbps
August 2006
CLC018
Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (VCC–V
EE)
VLL Maximum
VCC +6V
VCC −0.5V
Lead Temp. (Soldering 4 sec.)
75˚C/W
θJC 64-Pin PQFP
15˚C/W
Reliability Information
Transistor Count
3000
−0.3V to +6.0V
VLL Minimum
Storage Temperature Range
θJA 64-Pin PQFP
Recommended Operating
Conditions
−65˚C to +150˚C
+260˚C
Supply Voltage (VCC–V
TBD
Operating Temperature
−40˚C to +85˚C
VLL
VCC or VCC +5V
ESD Rating
Package Thermal Resistance
EE)
4.5V to 5.5V
Electrical Characteristics
(VCC = 0V, VEE = −5V, VLL = 0V; unless otherwise specified) (Note 4).
Parameter
Conditions
Typ
+25˚C
Min/Max
+25˚C
Min/Max
−40˚C to
+85˚C
Units
DYNAMIC PERFORMANCE
Max. Data Rate/Channel (NRZ)
(Note 5)
1.485
Gbps
Channel Jitter
Data Rate < 500 Mbps
(Note 6)
50
psPP
Data Rate < 1.485 Gbps
(Note 6)
100
psPP
0.75
ns
Propagation Delay (input to output)
Propagation Delay Match
(Note 7)
± 200
ps
Output Rise/Fall Time
(Note 8)
250
ps
Duty Cycle Distortion
(Note 9)
10
ps
OA Bus to LOAD ↑ Setup Time (T1)
15
ns
LOAD ↓ to OA Bus Hold Time (T2)
0
ns
IA Bus, TRI to LOAD ↓ Setup Time (T3)
5
ns
LOAD ↓ to IA Bus, TRI Hold Time (T4)
5
ns
LOAD
10
ns
CNFG
10
ns
0
ns
CONTROL TIMING: CONFIGURATION
Min Pulse Width: (T5)
LOAD ↑ to CNFG ↑ Delay (T6)
CNFG ↑ to Valid Delay (T 7)
20
ns
CNFG ↑ to Output TRI-STATE ® Delay (T8)
20
ns
CNFG ↑ to Output Active Delay (T9)
70
ns
5
ns
CONTROL TIMING: RESET (Note 11)
TRI to RES ↑ Setup Time (T10)
RES ↓ to TRI Hold Time (T
5
ns
10
ns
RES ↑ to TRI-STATE Mode Delay (T13)
20
ns
RES ↑ to Broadcast Mode Delay (T14)
70
ns
Min Pulse Width: RES (T
11)
12)
STATIC PERFORMANCE
Signal I/O:
Min Input Swing, Differential
(Note 3)
150
Input Voltage Range Lower Limit
−2
Input Voltage Range Upper Limit
0.4
200
200
mVPP
V
V
Input Bias Current
(Notes 3, 12)
1.5
0.4/3.1
0.3/3.8
µA/output
Output Current
(Note 3)
10.7
8.53/12.80
7.20/14.3
mA
www.national.com
2
CLC018
Electrical Characteristics
(Continued)
(VCC = 0V, VEE = −5V, VLL = 0V; unless otherwise specified) (Note 4).
Parameter
Conditions
RLOAD = 75Ω
Output Voltage Swing
Typ
+25˚C
Min/Max
+25˚C
Min/Max
−40˚C to
+85˚C
Units
800
640/960
540/1060
mV
Output Voltage Range Lower Limit
−2.5
V
Output Voltage Range Upper Limit
0
V
Control Inputs:
Input Voltage - HIGH
V
Input Voltage - LOW
V
IH min
(Note 3)
−1
−0.5
−0.5
V
IL max
(Note 3)
−4
−4.5
−4.5
V
IH min
VLL = +5V (Note 3)
4
4.5
4.5
V
IL max
VLL = +5V (Note 3)
1
0.5
0.5
V
Input Current - HIGH
VIH = VLL (Note 3)
1
0.2/2.0
0.1/2.5
µA
Input Current - LOW
VIL = VLL −5V (Note 3)
−100
−200/10
−250/15
µA
VCC Supply Current
All Outputs Active
(Notes 3, 13, 14)
157
127/202
119/217
mA
VCC Supply Current
All Outputs TRI-STATE
(Note 3)
7
3/11
2/12
mA
VLL Supply Current
VLL = 0V (Note 3)
2.5
1.7/3.3
1.5/3.5
mA
VLL Supply Current
VLL = +5V (Note 3)
7
mA
1.5
pF
2
pF
Input Voltage - HIGH
V
Input Voltage - LOW
V
MISCELLANEOUS PERFORMANCE
Input Capacitance
Output Capacitance
Note 1: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the devices
should be operated at these limits. The table of “Electrical Characteristics” specifies conditions of device operation.
Note 2: Min/max ratings are based on product characterization and simulation. Individual parameters are tested as noted. Outgoing quality levels are determined
from tested parameters.
Note 3: J-level spec. is 100% tested at +25˚C.
Note 4: VLL and all VEE supply pins are bypassed with 0.01 µF ceramic capacitor.
Note 5: Bit error rate less than 10−9 over 50% of the bit cell interval.
Note 6: Measured using a pseudo-random (2 23−1 pattern) binary sequence with all other channels active with an uncorrelated signal.
Note 7: Spread in propagation delays for all input/output combinations.
Note 8: Measured between the 20% and 80% levels of the waveform.
Note 9: Difference in propagation delay for output low-to-high vs. output high-to-low transition.
Note 10: Refer to the Configuration Timing Diagram.
Note 11: Refer to the Reset Timing Diagram.
Note 12: The bias current for high speed data input depends on the number of data outputs that are selecting that input.
Note 13: The VCC supply current is a function of the number of active data outputs. IVCC 18*N + 7 mA where N is an integer from 0 to 8.
Note 14: IVEE = IVCC + I VLL.
3
www.national.com
CLC018
Typical Performance Characteristics
10008803
www.national.com
10008804
10008805
10008806
10008807
10008808
4
CLC018
Connection Diagram
10008809
Order Number CLC018AJVJQ
See NS Package Number VJQ64A
addressed, IA2, IA1, IA0 should have 1, 1, 0 asserted on
them. The IA bus should be driven with CMOS levels, if VLL
is +5V. These levels are thus +5V referenced (standard
CMOS). If VLL is connected to GND, the input levels are
referenced to the −5V and GND supplies.
OA2, OA1 and OA0 are the output selection address bus.
The output port selected by the OA bus is connected to the
input port selected on the IA bus when the data is loaded into
the configuration registers. OA2 is the MSB. If OA2, OA1,
OA0 are set to 0, 0, 1; then output port 1 will be selected.
CS is an active-high chip select input. When CS is high, the
RES, LOAD, and CNFG pins will be enabled.
LOAD is the latch control for the LOAD register. When LOAD
is high, the load register is transparent. Outputs follow the
state of the IA bus, and are presented to the inputs of the
Configuration register selected by the OA bus. When LOAD
is low, the outputs of the Load register are latched.
Pin Descriptions
POWER PINS
VCC is the most positive rail for the data path. When the data
levels are ECL compatible, then VCC should be connected to
GND. For PECL data (+5V referenced ECL), VCC is connected to the +5V supply. Please refer to the device operation section in this datasheet for recommendations on the
bypassing and ground/power plane requirements of this device.
VEE is the most negative rail for the data path. When the data
levels are ECL compatible, then VEE is connected to a −5.2V
power supply. For PECL data (+5V referenced ECL), V EE is
connected to GND.
VLL is the logic-level power supply. If the control signals are
referenced to +5V, VLL is connected to a +5V supply. If
control signals are ECL compatible, VLL is connected to
GND.
RES is the reset control of the configuration and load registers. A high-going pulse on the RES pin programs the switch
matrix to one of two possible states: with TRI low, all outputs
are connected to input #0; with TRI high, all outputs are put
in TRI-STATE condition.
TRI will program the selected output to be in a high impedance or TRI-STATE condition. To place an output in TRISTATE, assert a logic-high level on the TRI input when the
desired input and output addresses are asserted on the
respective address inputs and strobe the LOAD input as
depicted in the ”Configuration Truth Table”. To enable an
output, assert a logic-low level on the TRI input together with
the appropriate addresses and strobe the LOAD input as
previously described.
CNFG is the configuration register latch control. When
CNFG is high the Configuration register is made transparent,
and the switch matrix is set to the state loaded into the Load
registers. When CNFG is low, the state of the switch matrix
is latched.
DATA INPUT PINS
DI0 and DI0 through DI7 and D17 are the data input pins to
the CLC018. Depending upon how the Power pins are connected (please refer to the Power Pin section above) the
data may be either differential ECL, or differential PECL. To
drive the CLC018 inputs with a single-ended signal, please
refer to the section “Using Single-Ended Data” in the OPERATION section of this datasheet.
DATA OUTPUT PINS
DO0 and DO0 through DO7 and DO7 are the data output
pins of the CLC018. The CLC018 outputs are differential
current outputs which can be converted to ECL or PECL
compatible outputs through the use of load resistors. Please
refer to the “Output Interfacing” paragraph in the OPERATION section of this datasheet for more details.
CONTROL PINS
IA2, IA1 and IA0 are the three bit input selection address
bus. The input port to be addressed is placed on this bus.
IA2 is the Most Significant Bit (MSB). If input port 6 is to be
5
www.national.com
CLC018
Timing Diagrams
10008810
FIGURE 1. Timing Diagram — TRI-STATE Reset
10008811
FIGURE 2. Timing Diagram — “Broadcast Reset”
www.national.com
6
CLC018
Timing Diagrams
(Continued)
10008812
FIGURE 3. Timing Diagram — Switch Configuration
Operation
INPUT INTERFACING
The inputs to the CLC018 are high impedance differential
inputs (see the equivalent input circuit in Figure 4). The
CLC018 can be operated with either ECL or PECL (+5V
referenced ECL), depending upon the power supply connections. The inputs are differential and must both be within the
range of VCC– 2V to VCC + 0.4V in order to function properly.
10008813
FIGURE 4. Equivalent Input Circuit
7
www.national.com
CLC018
Operation
(Continued)
SINGLE ENDED INPUTS
Differential inputs are the preferred method of providing data
to the CLC018, however, there are times when the only
signal available is single ended. To use the CLC018 with a
single ended input, the unused input pin needs to be biased
at a point higher than the low logic level, and lower than the
high logic level. For best noise performance, the middle of
the range is best. For ECL signals this point is about 2 diode
drops below ground. It is possible to bias the unused input
with a low-pass filtered version of the data, as shown in
Figure 5. In some coding schemes there are pathological
patterns that result in long sequences with no data transitions. During these patterns, the bias on the unused input will
drift towards the other input reducing the noise immunity
which makes this scheme undesirable. The most robust
solution for single ended inputs is to place a comparator with
hysteresis in front of the CLC018. Such a part is the
MC10E1652. See Figure 6 for an example of how to hook
this up.
10008816
FIGURE 7. Generating 10k ECL Outputs
10008814
10008817
FIGURE 5. Single Ended Input to CLC018
FIGURE 8. Generating ECL Outputs
10008815
FIGURE 6. Single Ended Input to CLC018
10008818
OUTPUT INTERFACING
The outputs of the CLC018 are differential, current source
outputs. They can be converted to ECL compatible levels
with the use of resistive loads as shown in Figure 7. The
output swings will have a similar temperature coefficient to
10KECL if a 1N4148 diode is used to set VOH. For most
commercial temperature range applications, a 75Ω resistor
can be used as shown in Figure 8. Many circuits with differential inputs, such as the CLC016 Data Retimer With Automatic Rate Selection, do not require true ECL levels, so the
load resistors can be connected directly to the positive rail as
shown in Figure 9.
www.national.com
FIGURE 9. Connecting the CLC018 to the CLC016
OUTPUT SIGNAL QUALITY
The output signal eye pattern shown in Figure 10 was acquired using an Agilent 86100A scope and 86112A plug in
along with a TEK P6330 3GHz differential probe. The differential signal was probed across the output pins of the
CLC018. 75 Ohm pull up resistor were used as shown in
Figure 9. A PRBS23 pattern was driven through the part, and
the resulting eye pattern is shown in Figure 10. The eye
pattern is affected by the HF roll-off of the probe which
degrades the output transition time and affects jitter. Even
with this loading the CLC018 provides excellent signal quality and low jitter at 1.485 Gbps. Note 150 ps/div and 250
mV/div
8
significant bit controls whether the output is active or TRISTATE. A particular register in the first rank, the LOAD
REGISTERS, is selected by a 3-bit word placed on the
output address (OA) bus. Data to be written into the load
register, consisting of the 3-bit address of the input to be
connected to that output and the output-enable control bit,
are placed on the input address (IA) bus. Input data is stored
in the load registers at the low-to-high transition of the LOAD
input pin with chip-select (CS) high-true. The contents of the
load registers are transferred to the second rank of CONFIGURATION REGISTERS at the low-to-high transition of
the CNFG input signal (with CS high). This causes the state
of the entire switch matrix to be set to the selected configuration.
(Continued)
The entire crosspoint may be placed in an initializing state,
with all outputs connected to input-0 and with all outputs
either enabled or TRI-STATE. To do so, hold TRI low to make
outputs active, or high to place outputs in TRI-STATE, and
apply a high-going pulse to the RES input pin (with CS high).
In summary, outputs are configured by:
a) first placing the 3-bit address of that output on the OA
bus together with
b) the 3-bit address of the input to be connected to that
output on the IA bus,
c) the output-enable (TRI-STATE) control bit for that output
on the IA bus,
d) making chip-select (CS) true, and then
e) providing a high-going pulse to the LOAD input pin.
10008826
FIGURE 10. 1.485 Gbps Eye Pattern
POWER SUPPLIES, GROUNDING AND BYPASSING
The CLC018 uses separate power supplies for control and
data circuitry. Data circuitry is supplied via VCC and control
circuitry via VLL. Supply connection VEE, the negative-most
supply, is the common return for both. Connection details for
the different powering modes is shown in Table 1.
Internal and external capacitances, normal and parasitic,
must be charged and discharged with changes in output
voltage. Charging current depends upon the size of these
capacitances and the rate of change of voltage. At the fast
transition times of the CLC016, small amounts of stray capacitance at outputs can produce large output and supply
transient currents. Controlling transient currents requires
particular attention to minimizing stray capacitances and to
providing effective bypassing in the design. Good and effective bypassing consisting of 0.01 µF to 0.1 µF monolithic
ceramic and 4.7 µF to 10 µF, 35V tantalum capacitors. These
capacitors should be placed as close to power pins as
practical and tightly connected to the power plane sandwich
using multiple vias. Needless to say, multilayer board technology should be employed for the CLC018 and similar
high-frequency-capability devices.
f)
Repeat these four steps for each output to be
configured.
The entire crosspoint matrix may now be configured with the
data held in the load registers. To implement the configuration, apply a high-going pulse to the CNFG input pin. The
contents of the load registers are transferred to the configuration registers and the new configuration of all crosspoints
is effected.
The CLC018 Configuration Truth Table is shown at the end
of the datasheet.
EXPANDING THE SWITCH SIZE
The CLC018 was designed for easy expansion to larger
array sizes without paying a significant penalty in either
speed or power. The power dissipation of the expanded
array will be dominated by the number of active outputs,
therefore power will increase linearly with the array size even
though the number of components required increases as the
square of the array size. As an example, a single CLC018
can be used for an 8x8 array, and it will dissipate about
0.85W. A 32 x 32 array will require 16 CLC018s and will
consume only about 4W.
CONFIGURING THE SWITCH
The CLC018 can be configured so that any output may be
independently connected to any input and any input be
connected to any or all outputs. Each output may be independently enabled or placed in a high-impedance state.
Data controlling the switch matrix and output mode are
stored in two ranks of eight, 4-bit registers, one register per
output. The three most-significant bits in each register identify the input to be connected to that output. The least-
9
www.national.com
CLC018
Operation
CLC018
Operation
(Continued)
TABLE 1. Interfacing of the Power Supplies and Bypass Capacitors
Supply Operation
I/O Data Level
Control Signal Low/High
Dual ± 5V
Single −5V
Single +5V
ECL
PECL
ECL
−5V/GND
GND/+5V
GND/+5V
1. Bypass each VEE supply
with a 0.01 µF capacitor. 2.
Connect VCC and VLL to the
ground plane. 3. A power
plane isn’t required for VEE
but can be used.
1. Bypass each VCC supply with
a 0.01 µF capacitor. 2. Bypass
the VLL supply with a 0.01 µF.
3. Connect VEE to the ground
plane. 4. Use a +5V power
plane for VCC.
Connection
Key Information
EXPANDING THE NUMBER OF OUTPUT PORTS
To expand the number of output ports in a switch array, the
inputs of multiple CLC018s are connected in parallel. The
bus used to connect the input ports should be a controlled
impedance transmission line as shown in Figure 11. To
www.national.com
1. Bypass each VEE supply
with a 0.01 µF capacitor. 2.
Bypass the VLL supply with a
0.01 µF. 3. Connect VCC to
the ground plane. 4. A power
plane isn’t required for +5V
(VLL) or −5V (VEE) supplies.
but can be used.
control the switch array, the IA, OA and TRI busses are all
connected in parallel and a decoder is used to assert high
the CS of the CLC018 that is to be addressed. This is also
shown in Figure 11.
10
CLC018
Operation
(Continued)
10008820
FIGURE 11. 8 x 16 Crosspoint Example
EXPANDING THE NUMBER OF INPUT PORTS
Expanding the number of inputs in a switch array is accomplished by wire-ORing the outputs together, and TRISTATEing the outputs of the CLC018s that do not have their
inputs selected. The output bus should be a controlled impedance transmission line with proper termination. This is
shown in Figure 12. The circuit uses a 1-of-2 decoder with
complemented outputs to control the TRI pins of the
CLC018s in the array. Thus, all CLC018s are programmed
simultaneously, and all of them, except for the one with the
selected input, are placed in the TRI-STATE mode.
EXPANDING BOTH INPUTS AND OUTPUTS
To increase both the number of inputs and outputs in an
array, apply both the input port and output port expansion
techniques simultaneously. In Figure 13, this is shown for the
case of a 24 input by 32 output switch array. Note that both
input and output busses need to be controlled impedance
transmission lines. The CS pins for rows of CLC018s are
connected together and become the row select inputs,
whereas the TRI pins are connected together for the columns of CLC018s and become the column select pins.
11
www.national.com
CLC018
Operation
(Continued)
10008821
FIGURE 12. Expanded Input Ports
www.national.com
12
CLC018
Operation
(Continued)
10008822
FIGURE 13. 24 x 32 Output Switch Array
13
www.national.com
CLC018
Operation
tance) are used to drive bus networks, a series resistor
connects the output of the amplifier to the transmission line.
This resistor serves both as a termination for any signals
travelling toward the source- end of the line and as the series
leg of a voltage divider (with the transmission line as the
shunt leg) to reduce the transmitted signal level. This resistor’s correct value is ZO − R OUT. However, a value equal to
ZO may be used successfully in most situations. The receiving end of the line is terminated in a resistance equal to the
value of ZO of the receiving end of the line. A resistance
equal to the line’s ZO works in most situations. In cases
where the bus is heavily loaded, the receiving end termination’s value may need to be reduced to the loaded- ZO of the
line. (Please see the material on distributed loading effects
on line characteristics in the Fairchild F100K ECL 300 Series
Databook and Design Guide).
Current-mode drivers, with their high equivalent generator
resistance, when used as bus drivers require a resistance
equal to Z O at each end of the bus to either power or ground
as appropriate for the design.
(Continued)
CALCULATING THE POWER DISSIPATION IN AN
EXPANDED ARRAY
The CLC016 dissipates about 100 mW per active output plus
about 50 mW quiescent power. With all outputs active, this is
about 850 mW. In an expanded array, all devices will dissipate quiescent power, but only those devices with active
outputs will dissipate the 100 mW/output. So, an N-by-M
device array (an 8xN-input-by-8xM-output switch) with all
outputs active will dissipate N x M x 50 mW + 8 x M x 100
mW. A 32-input x 32-output (4 x 4 device) switch array
dissipates 4 x 4 x 50 mW + 8 x 4 x 100 mW = 4W.
CONTROLLED IMPEDANCE TRANSMISSION LINES
AND OTHER LAYOUT TECHNIQUES
All transmission lines whose length is greater than 1⁄4 wavelength of the highest frequencies present in the transmitted
signal require proper attention to impedance control to avoid
distortion of the signal. Digital signals are especially susceptible to distortion due to poorly controlled line characteristics
and reflections. With its 250 ps output transitions, which
imply a bandwidth of 4 GHz or more, transmission lines
driven by the CLC018 must be carefully designed and correctly terminated. Either microstrip line, which resides on the
outer surfaces of a printed circuit board and paired with an
image ground plane, or stripline, which is sandwiched in an
inner layer between image ground planes, may be used in
CLC018 designs. With either line type, it is important to
maintain a uniform characteristic impedance over the entire
extent of the transmission line system. Likewise, the receiving end of these lines must be terminated in a resistance
equal to the characteristic impedance to preserve signal
fidelity. Figure 14 shows representative methods of interfacing to and from the CLC018.
Often, when voltage-mode drivers, such as ECL, with low
output impedance (also called equivalent generator resis-
www.national.com
A detailed discussion of digital transmission line design techniques is beyond the scope of this data sheet, but many
good references are available from National Semiconductor
and others. Extensive material is available in the National
Interface Databook, the Fairchild F100K ECL 300 Series
Databook and Design Guide and the Motorola MECL System Design Handbook.
Especially useful is the National Semiconductor Transmission Line RAPIDESIGNERr Sliderule and user manual AN905. The RAPIDESIGNER is available by calling the National Semiconductor Customer Response Center in your
area and asking for either Literature Number 633200-001
(ISO Metric units) or 633201-001 (English units). The User
Manual for both versions is Literature Number 100905-002
and is available on our WEB Site at http://www.national.com
as AN-905.
14
CLC018
Operation
(Continued)
10008823
FIGURE 14. Input/Output Bussing
15
www.national.com
CLC018
Configuration Truth Table
IA2
IA1
IA0
OA2
OA1
OA0
TRI
RES
LOAD
CNFG
CS
X
X
X
X
X
X
X
X
X
X
0
Condition of Device
NO CHANGE
X
X
X
X
X
X
0
I
X
X
1
Load I/P 0 to All O/Ps
X
X
X
X
X
X
1
I
X
X
1
TRI-STATE All O/P 0
X
X
X
0
0
0
1
0
I
0
1
TRI-STATE O/P 0
X
X
X
0
0
1
1
0
I
0
1
TRI-STATE O/P 1
X
X
X
0
1
0
1
0
I
0
1
TRI-STATE O/P 2
0
1
TRI-STATE O/P CBA
•
0
•
1
X
X
X
C
B
A
1
0
I
•
R
•
Q
•
P
•
C
•
B
•
A
•
0
•
0
•
I
•
Load I/P PQR to O/P
CBA and Enable O/P
CBA
•
•
•
•
•
•
•
•
•
•
•
•
0
0
0
0
0
0
0
0
I
0
1
Load I/P 0 to O/P 0
0
0
0
0
0
1
0
0
I
0
1
Load I/P 0 to O/P 1
0
0
0
0
1
0
0
0
I
0
1
Load I/P 0 to O/P 2
0
0
0
0
1
1
0
0
I
0
1
Load I/P 0 to O/P 3
0
0
0
1
0
0
0
0
I
0
1
Load I/P 0 to O/P 4
0
0
0
1
0
1
0
0
I
0
1
Load I/P 0 to O/P 5
0
0
0
1
1
0
0
0
I
0
1
Load I/P 0 to O/P 6
0
0
0
1
1
1
0
0
I
0
1
Load I/P 0 to O/P 7
0
0
1
0
0
0
0
0
I
0
1
Load I/P 1 to O/P 0
0
0
1
0
0
1
0
0
I
0
1
Load I/P 1 to O/P 1
0
0
1
0
1
0
0
0
I
0
1
Load I/P 1 to O/P 2
0
0
1
0
1
1
0
0
I
0
1
Load I/P 1 to O/P 3
•
0
•
0
•
1
•
1
•
1
•
1
•
0
•
0
•
•
0
•
1
•
Load I/P 1 to O/P 7
I
•
•
•
•
•
•
•
•
•
•
•
•
1
1
1
1
1
0
0
0
I
0
1
Load I/P 7 to O/P 6
1
1
1
1
1
1
0
0
I
0
1
Load I/P 7 to O/P 7
X
X
X
X
X
X
X
0
0
I
1
Activate New
Configuration
www.national.com
16
CLC018 8 x 8 Digital Crosspoint Switch, 1.485 Gbps
Physical Dimensions
inches (millimeters) unless otherwise noted
64-Lead PQFP
Order Number CLC018AJVJQ
NS Package Number VJQ64A
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves
the right at any time without notice to change said circuitry and specifications.
For the most current product information visit us at www.national.com.
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS
WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body, or
(b) support or sustain life, and whose failure to perform when
properly used in accordance with instructions for use
provided in the labeling, can be reasonably expected to result
in a significant injury to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or
system, or to affect its safety or effectiveness.
BANNED SUBSTANCE COMPLIANCE
National Semiconductor follows the provisions of the Product Stewardship Guide for Customers (CSP-9-111C2) and Banned Substances
and Materials of Interest Specification (CSP-9-111S2) for regulatory environmental compliance. Details may be found at:
www.national.com/quality/green.
Lead free products are RoHS compliant.
National Semiconductor
Americas Customer
Support Center
Email: [email protected]
Tel: 1-800-272-9959
www.national.com
National Semiconductor
Europe Customer Support Center
Fax: +49 (0) 180-530 85 86
Email: [email protected]
Deutsch Tel: +49 (0) 69 9508 6208
English Tel: +44 (0) 870 24 0 2171
Français Tel: +33 (0) 1 41 91 8790
National Semiconductor
Asia Pacific Customer
Support Center
Email: [email protected]
National Semiconductor
Japan Customer Support Center
Fax: 81-3-5639-7507
Email: [email protected]
Tel: 81-3-5639-7560