ATMEL TSS463A-TERZ

Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Fully Compliant to VAN Specification ISO/11519-3
Handles All Specified Module Types
Handles All Specified Message Types
Handles Retransmission of Frames on Contention and Errors
3 Separate Line Inputs with Automatic Diagnosis and Selection
Normal or Pulsed (Optical and Radio Mode) Coding
VAN Transfer Rate: 1 Mbit/s Maximum
SPI/SCI Interface
– SPI Transfer Rate: 4 Mbit/s Maximum
– SCI Transfer Rate: 125 Kbit/s Maximum
Idle and Sleep Modes
128 Bytes of General-purpose RAM
14 Identifier Registers with All Bits Individually Maskable
6-source Maskable Interrupt, Including an Interrupt-on-reset to Detect Glitches on the
Reset Pin
Integrated Crystal or Resonator Oscillator with Internal Baud Rate Generator and
Buffered Clock Output
Single +5V Power Supply
0.8 µm CMOS Technology
SO16 Package
VAN Data Link
Controller with
Serial Interface
TSS463-AA
Description
The TSS463AA is a circuit that allows the transfer of all the status information needed
in a car or truck over a single low-cost wire pair, that minimizes electrical wire usage. It
can be used to interconnect powerful functions to control and interface car body electronics (lights, wipers, power window, etc.).
The TSS463AA is fully compliant with the VAN ISO Standard 11519-3. This standard
supports a wide range of applications such as low-cost remote-controlled switches.
Typically it is used for lamp control, complex, highly-autonomous, distributed systems,
which require fast and secure data transfers.
The TSS463AA is a microprocessor-interfaced line controller for mid- to high-complexity bus-masters and listeners like dashboard controllers, car stereo or mobile
telephone CPUs.
The microprocessor interface consists of a 256-byte RAM and a register area divided
into 11 control registers, 14 channel register sets and 128 bytes of general purpose
RAM, used as a message storage area, and a 6-source maskable interrupt.
The circuit operates in the RAM using DMA techniques, controlled by the channel and
control registers. This allows virtually any microprocessor, including SPI/SCI interface,
to be connected easily to the TSS463AA.
Messages are encoded in enhanced Manchester code, and an optional pulsed code
for use with an optical or radio link, at a maximum bit rate of 1 Mbit/s. The TSS463AA
analyzes the messages received or transmitted according to 6 different criteria including some higher level checks.
In addition, the bus interface has three separate inputs with automatic source diagnosis and selection. The interface allows for multibus listening or the automatic selection
of the most reliable source at any time if several line receivers are connected to the
same bus.
4205B–AUTO–12/04
1
Block Diagram
2
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Pin Configuration
TOP VIEW
1
16
2
15
3
14
VDD
4
13
GND
XTAL1
5
12
TXD
XTAL2
6
11
RXD0
TEST/VSS
7
10
RXD2
CKOUT
8
9
RXD1
MISO
SS
INT
MOSI
SCLK
RESET
Pin Description
I/O Type
Pin Name
Pin No.
O 3-state
MISO
1
SPI/SCI Data Output
I trigger CMOS
SS
2
SPI/SCI Slave Select (active low)
Open-drain
INT
3
Interrupt (active low)
Power
VDD
4
+ 5V power supply
I CMOS
XTAL1
5
Crystal oscillator or clock input pin from 1 to 16 MHz
O
XTAL2
6
Crystal oscillator output pin
TEST/VSS
7
Test mode input
CKOUT
8
Buffered clock output
I CMOS Pull-down
RXD1
9
VAN bus input 1
I CMOS Pull-down
RXD2
10
VAN bus input 2
I CMOS Pull-down
RXD0
11
VAN bus input 0
O 3-state
TXD
12
VAN bus output
Ground
GND
13
RESET
14
Hardware Reset (active low)
I trigger CMOS
SCLK
15
SPI/SCI Clock Input
I trigger CMOS
MOSI
16
SPI/SCI Data Input
Ground
O
I trigger CMOS pull-up
Pin Function
3
4205B–AUTO–12/04
Application
The TSS463AA is a microprocessor controlled line controller for the VAN bus. It can
interface to virtually any microprocessor which includes SPI or SCI interface.
•
The TSS463AA provides one full Motorola compatible SPI interface.
•
It includes one full compatible Intel UART (mode 0 only).
•
And finally, one 9-bits SCI interface is also integrated.
In addition, the circuit features a single interrupt pin. This pin can be treated as level
sensitive. For example, if there is a pending interrupt inside the circuit when another
interrupt is reset, the INT pin will emit a high pulse with the same pulse width as the
internal write strobe (typically 20 ns).
Figure 1. Typical Application With Motorola SPI Mode
Remaining pins
MISO(2)
PORT X.Y
IRQ
General I/O
(if needed)
100K
MISO
SS
16
2
15
3
14
INT
VDD
CKOUT
MOSI
1
XTAL1
4
5
XTAL2
RESET (1)
Notes:
4
13
GND
TxD
12
6
11
7
10
8
9
TEST/VSS
CKOUT
SCLK
RESET (1)
TSS463
Microcontroller
mC
SCLK
MOSI
RxD0
RxD2
VAN Bus
RxD1
1. The TSS463AA RESET pin can either be connected to GND through a 1 µF capacitor, or the µC RESET pin or unconnected (inactive with internal pull-up).
2. Leaving MISO output pin floating in high impedance mode slightly increases standby
consumption. A 100 KΩ pull-up/pull-down resistor is recommended.
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Microprocessor
Interface
The processor controls the TSS463AA by reading and writing the internal registers of
the circuit. These registers appear to the processor as regular memory locations.
Interface Modes
The TSS463AA must be connected with an SPI or SCI serial interface. The following
section provides information on switching from one mode to another.
Motorola SPI Mode
The first two bytes to be sent by the master (CPU) are called “Initialization Sequence”:
This sequence provides a proper asynchronous RESET in the TSS463AA and it selects
the Motorola SPI, Intel SPI or the SCI serial mode. This initialization sequence is shown
on Figure 4. Two 0x00 will cause an internal RESET and assert the Motorola SPI mode,
Two “0xFF” will provide an internal RESET and assert the Intel® SPI mode and “9 bits to
0 followed by 0xFF or 0xFE” will generate an internal RESET and assert the 9-bits SCI
mode.
Figure 2. Mode Configuration Byte
SPI 8 Pulses
SCLK
MOSI
0x00
or 0xFF
0x00
0xFF
Motorola
Intel
SS
Internal RESET
Internal RESET and SPI Mode (Intel or Motorola)
SCI 9 Pulses
SCLK
MOSI
0 . 0000 . 0000
1 . 1111 . 1111
SS
Internal RESET
Internal RESET and SCI Mode
The Motorola Serial Peripheral Interface (SPI) is fully compatible with the SPI Motorola
protocol. The interface is implemented for slave-mode only (the TSS463AA can not generate SPI frames by itself).
The SPI interface allows the interconnection of several CPUs and peripherals on the
same printed circuit board.
The SPI mode interface consists of 4 pins: separate wires are required for data and
clock, so the clock is not included in the data stream as shown in Figure 5. One pin is
needed for the serial clock (SCLK), two pins for data communication MOSI and MISO
and one pin for Slave Select (SS).
5
4205B–AUTO–12/04
Figure 3. SPI Data Stream
SPI 8 Pulses
SCLK
MOSI
0x55
MISO
0x66
SS
SCLK: Serial Clock
The master device provides the serial clock for the slave devices. Data is transferred
synchronously with this clock in both directions. The master and the slave devices
send/receive a data byte during an eight-clock pulse sequence.
MOSI: Master Out Slave In
The MOSI pin is the master device data output (CPU) and the slave device data input
(TSS463AA). Data is transferred serially from the master to the slave on this line; most
significant bit (MSB) first, least significant bit (LSB) last.
MISO: Master In Slave Out
The MISO pin is configured as the slave device data output (TSS463AA) and as master
device data input (CPU). When the slave device is not selected (SS = 1), this pin is in
high impedance state.
SS: Slave Select
The SS pin is the slave chip select. It is low active. A low state on the Slave Select input
allows the TSS463AA to accept data on the MOSI pin and send data on the MISO pin.
The Slave Select signal must not toggle between each transmitted byte and should be
left at a low level during the whole SPI frame. SS must be asserted to inactive high level
at the end of the SPI frame.
As mentioned before, if SS is not asserted, MISO pin is in a high impedance state and
incoming data is not driven to the serial data register.
SPI Protocol
The general format of the data communication in the SPI frame between the TSS463AA
and the host is a bit-for-bit exchange on each SCLK clock pulse. Data is arranged in the
TSS463AA such that the significance of a bit is determined by its position from the start
for output and from the end for input, most significant bit (MSB) is sent first. Bit
exchanges in multiples of 8 bits are allowed.
The Idle Clock Polarity (CPOL) and the Clock Phase (CPHA) are not programmable: the
CPOL and CPHA values to be programmed in the master (CPU) are CPOL = CPHA = 1.
This is available for all modes. Waveforms with transmit and sample points are shown in
Figure 6.
6
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Figure 4. CPOL and CPHA in the TSS463AA
CPOL = CPHA = 1
Data Sample Points
SPI 8 Pulses
SCLK
MOSI
0x55
MISO
0x66
SS
Data Transmit Points
At the beginning of a transmission over the serial interface, the first byte is the address
of the TSS463AA register to be accessed. The next byte transmitted is the control byte
which determines the direction of the communication. The following bytes are data bytes
(consecutive bytes are written in or read from Address, Address + 1, Address + 2,...,
Address + n with n = 0 to 28).
To make sure the TSS463AA is not out of synchronization, the SPI interface will transmit data “0xAA" and "0x55” on the MISO pin during address and control byte time. This
way, the master always ensures the TSS463AA is well-synchronized. If the TSS463AA
is out of synchronization, the master can assert the SS pin inactive to re synchronize the
SPI interface or can assert the RESET pin active or can send an initialization sequence.
When the SS pin is inactive, the SCLK is allowed to toggle. This will have no effect on
the TSS463AA SPI module.
SPI Control Byte
The SPI control byte is transmitted by the master (CPU) to the TSS463AA. It specifies
whether it is a TSS463AA Write or Read.
Table 1. SPI Control Byte
DIR: Serial Transfer Direction
7
6
5
4
3
2
1
0
DIR
1
1
0
0
0
0
0
Zero: Read Operation. The data bytes will be read by the master (CPU) from the
TSS463AA.
One: Write Operation. The data bytes will be written by the master (CPU) to the
TSS463AA.
In both cases, address auto-increment mechanism will take place when more than one
data byte is read or written. This mechanism is inhibited when address value reaches
0xFF.
The seven following bits are reserved and must be equal to: 1100000.
When the master (CPU) conducts a write, it sends an address byte, a control byte and
data bytes on its MOSI line. The slave device (TSS463AA) will send, if well-synchronized, “0xAA” during the address byte and “0x55” during the control byte on its MISO
line.
7
4205B–AUTO–12/04
When the master (CPU) conducts a read, it sends an address byte, a control byte and
dummy characters ("0xFF" for instance) on its MOSI line. In the case of a VAN messages RAM read (VAN frame received), the first data byte sent back by the TSS463AA
on its MISO pin is the data length so the master knows how many dummy characters it
must send to read the VAN frame properly. When the TSS463AA responds back with
data, it will not take care of the MOSI line.
The master must activate and de-activate SS between each data frame.
Synchronization bytes must be monitored carefully. For instance, if “0xAA” and “0x55”
are not monitored correctly, then the previous transmission may be incorrect too.
A control byte containing "0x00" or "0xFF" is forbidden except during an "Initialization
Sequence".
Intel SPI Mode
The Intel SPI mode is the second type of interface. As mentioned before, the TSS463AA
enters this mode if the Initialization Sequence contains (first two bytes received) "0xFF,
0xFF".
This mode is fully compatible to the Intel UART serial interface programmed in mode 0
only. It is the same as Motorola SPI mode (same CPOL and CPHA) but with inverted
communication sense (LSB first and MSB last). The protocol is also the same.
However, from the master point of view (host microcontroller), the hardware is different.
Figure 5 shows how to connect the TSS463AA and Intel type microcontroller.
Figure 5. Typical Application With the 8051 UART in Mode 0
General I/O
Remaining pins
optional
TXD
RXD
100k
PORT X.y
PORT X.z
SS
16
2
15
3
14
VDD
RESET (1)
C1
4
XTAL1
5
GND
13
TXD
12
XTAL2
RxD0
6
C2
XTAL1
Notes:
11
RxD2
TEST/VSS
CKOUT
SCLK
RESET (1)
TSS463
Microcontroller
1
INT
IRQ
8
MOSI
MISO
(if needed)
7
10
8
9
VAN Bus
RxD1
1. The RESET pin can either be connected to GND through a 1 µF capacitor, or the
microcontroller RESET pin or unconnected (inactive with internal pull-up).
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
The master device provides the serial clock on the TxD pin and is still connected to
SCLK pin of the slave device.
Then, the RxD replaces the MOSI and MISO pins and is a bi-directional pin. To achieve
a correct communication, the user should add a few gates to connect the master RxD
pin to the MOSI-MISO slave pins.
Figure 5 proposes two 3-state buffers controlled by the master through a general purpose I/O pin.
It is obvious that, in this Intel SPI mode, the master cannot monitor the "0xAA and 0x55"
synchronization bytes while sending the address and control bytes. It is the only exception in this mode compared with the Motorola SPI mode.
SCI Mode
The SCI mode is the third type of interface. The TSS463AA enters this mode if the Initialization Sequence contains (first two bytes received) "0x00, 0xFF".
The SCI is compatible with a 9-bits SCI protocol. The interface is implemented for slavemode only (the TSS463AA cannot generate SCI frames by itself).
The SCI interface allows an interconnection of several CPUs and peripherals on the
same printed circuit board.
The SCI mode interface consists of 4 pins: separate wires are required for data and
clock, so the clock is not included in the data stream as shown in Figure 6. One pin is
needed for the serial clock (SCLK), two pins for data exchange MOSI and MISO and
one pin for Slave Select SS.
Figure 6. SCI Data Stream
SCI 9 Pulses
SCLK
MOSI
0x55
MISO
0x66
SS
SCLK: Serial Clock
The master device provides the serial clock for the slave devices. Data is transferred
synchronously with this clock in both directions. The master and the slave devices
exchange a data byte during a nine clock pulses sequence. However, the TSS463AA
will only monitor 8 bits on its MOSI line and send 9 bits on its MISO line.
MOSI: Master Out Slave In
The MOSI pin is the master device data output (CPU) and the slave device data input
(TSS463AA). Data is transferred serially from the master to the slave on this line; least
significant bit (LSB) first, most significant bit (MSB) last. The TSS463AA will only monitor 8 bits starting from the LSB to MSB-1.
MISO: Master In Slave Out
The MISO pin is configured as the slave device data output (TSS463AA) and as master
device data input (CPU). When the slave device is not selected (SS = 1), this pin is in
high impedance state. The value of the MSB (9th bit) sent on the MISO pin will always be
"1" and should not be used by the master.
SS: Slave Select
The SS pin is the slave chip select. It is low active. A low state on the Slave Select input
allows the TSS463AA to accept data on the MOSI pin and send data on the MISO pin.
9
4205B–AUTO–12/04
The Slave Select signal must not toggle between each transmitted byte and therefore,
should be left at a low level during the whole SCI frame. SS must be asserted to inactive
high level at the end of the SCI frame.
If SS is not asserted, MISO pin is in high impedance state and incoming data is not
driven to the serial data register.
SCI Protocol
Same as the SPI protocol described earlier except for data arranging (LSB first and
MSB last).
Only 8 bits are monitored by the TSS463AA and master must monitor the 8 first
bits too (9th bit always equal to 1).
SCI Control Byte
Same as the SPI control byte.
Clocks and Speed
Considerations
SCLK and XTAL Clocks
The SPI/SCI speed rate is given by the CPU producing SCLK. XTAL clock controls the
speed rate on the VAN bus. The two clocks are asynchronous, but a minimum SPI/SCI
interframe spacing must be apply according to XTAL clock.
Intel and Motorola SPI Modes
Within an SPI byte, the maximum speed allowed on the MOSI line is 4 Mbits/s.
For example, when using a 1 MHz oscillator (sufficient to provide 62.5 kTS/s on the VAN
bus) the minimum inter-character delay is 12 µs (12 oscillator periods). Speed considerations are detailed in Figure 7.
Figure 7. SPI Speed Considerations
4 Mbits/s Max for SCLK
SCLK
MOSI
Address
Control
Data
SS
4 Xtal Min
8 Xtal Min
(4 s at 1 MHz)
(8 s at 1 MHz)
SCI Mode
10
15 Xtal Min
(15 s at 1 MHz)
12 Xtal Min
(12 s at 1 MHz)
Within an SCI 9-bits data, the maximum speed allowed on the MOSI line is 125 Kbits/s.
When using a 1 MHz oscillator, the data transfer speed and the minimum delay time
between SCI bytes are shown on Figure 8.
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Figure 8. SCI Speed Considerations
125 Kbits/s Max for SCLK
SCLK
Start Bit
MOSI
Stop Bit
Address
Control
Data
SS
4 Xtal Min
(4 s at 1 MHz)
Interrupts
8 Xtal Min
(8 s at 1 MHz)
15 Xtal Min
(15 s at 1 MHz)
12 Xtal Min
(12 s at 1 MHz)
If an event occurs in the TSS463AA that needs the attention of the processor, this will
be signalled on the active low, open-drain interrupt request pin. The event that creates
this request is controlled by the internal registers.
Every time the microprocessor accesses any of the interrupt registers (addresses 0x08
to 0x0B), the INT pin will be released momentarily. This enables the TSS463AA to work
with processors that have either edge or level sensitive interrupt inputs.
Reset
The reset is applied asynchronously or synchronously to the XTAL clock.
Asynchronous Reset
It can be done either by the RESET pin (hardware asynchronous reset) or by software
(software asynchronous reset).
The RESET pin is a CMOS trigger input with a pull-up resistor (~ 70 kΩ). An external
1 µF capacitor to GND provides to RESET pin an efficient behavior.
The asynchronous software reset is made by the "Initialization Sequence" described in
“Motorola SPI Mode” on page 5.
Two "0x00" bytes provide an asynchronous software reset and configure the TSS463AA
in the Motorola SPI mode while two "0xFF" bytes provide a reset and configure the component in the Intel SPI mode and "0x00 followed by 0xFF " provide a reset and configure
the component in the SCI mode. The SS pin must be asserted as shown on Figure 9.
The SPI/SCI logic will monitor these two bytes and provide an internal reset pulse
asserting the TSS463AA in the right mode.
Synchronous Reset
A synchronous reset (regarding XTAL clock) is available on the TSS463AA during current operation. It is made through the GRES command bit of the Command Register
(address 0x03).
The two kinds of reset are ordered and filtered. Then the internal reset, always asserted
asynchronously, enables the internal oscillator. Then it waits for 12 clock periods and
the oscillator stability.
The different blocks of the TSS463AA need to be turned on synchronously. The release
of the internal reset is synchronous and a loose of clock can let the TSS463AA in permanent reset after applying Reset.
It is important to note that even after a reset on the RESET pin, the user should wait for
12 clock periods before sending the "Initialization Sequence" in order to select the SPI
or SCI mode (because the default mode after a hardware reset is the Motorola SPI
mode).
11
4205B–AUTO–12/04
Figure 9. Asynchronous Software Reset with UART Intel Mode
4 XTAL Min
SCLK
15 XTAL Min
MOSI
0xFF
0xFF
SS
Detection of Forbidden Control
Reset Internal Pulse
End of Chip Select
Oscillator
An oscillator is integrated in the TSS463AA, and consists of an inverting amplifier of
which the input is XTAL1 and the output XTAL2.
A parallel resonance quartz crystal or ceramic resonator must be connected to these
pins. As shown in Figure 5, two capacitors have to be connected from the crystal pins to
ground. The values of C2 depend on the frequency chosen and can be selected using
the schematic given in Figure 39.
If the oscillator is not used, then a clock signal must be fed to the circuit via the XTAL1
input.
Note that this pin will behave as a CMOS level compatible Schmitt trigger input.
In this case the XTAL2 output should be left unconnected. The oscillator also features a
buffered clock output pin CKOUT. The signal on this pin is directly buffered from the
XTAL1 input, without inversion.
There is one more pin used for the oscillator. The TEST/VSS pin is in fact its ground,
and unless this pin is firmly connected to ground, with decoupling capacitors, the oscillator will not operate correctly.
The test mode itself, i.e., when the TEST/VSS pin is held high, is only intended for factory use, and the functionality of this mode is not specified in any way.
The TEST/VSS pin is subject to change without notice, the only exception is for incoming inspection tests using the test program.
The clock signal is then fed to the clock generator that generates all the necessary timing signals for the operation of the circuit. The clock generator is controlled by a 4-bit
code called the clock divider.
f ( XTAL1 )
f ( TSCLK ) = ------------------------n × 16
12
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Table 2. Clock Divider
8 MHz
6 MHz
4 MHz
2 MHz
Clock
Divider
Divide by
KTS/s
Kbits/s
KTS/s
Kbits/s
KTS/s
Kbits/s
KTS/s
Kbits/s
0000
1
500
400
375
300
250
200
125
100
0001
2
250
200
187.50
150
125
100
62.50
50
0010
4
125
100
93.75
75
62.50
50
31.25
25
0011
8
62.5
50
46.875+
37.5
31.25
25
15.625
12.5
0100
16
31.25
25
23.438
18.75
15.625
12.5
7.813
6.25
0101
32
15.625
12.5
11.718
9.375
7.813
6.25
3.906
3.125
0110
64
7.813
6.25
5.859
4.688
3.906
3.125
1.953
1.562
0111
128
3.906
3.125
500
400
1.953
1.562
166.666
133.333
1000
1.5
333.333
266.666
250
200
166.666
133.333
83.333
66.666
1001
3
166.666
133.333
125
100
83.333
66.666
41.666
33.333
1010
6
83.333
66.666
62.50
50
41.666
33.333
20.833
16.666
1011
12
41.666
33.333
31.25
25
20.833
16.666
10.416
8.333
1100
24
20.833
16.666
15.625
12.50
10.416
8.333
5.208
4.166
1101
48
10.416
8.333
7.813
6.25
5.208
4.166
2.604
2.083
1110
96
5.208
4.166
3.906
3.125
2.604
2.083
1.302
1.042
1111
192
2.604
2.083
1.953
1.5625
1.302
1.042
0.651
0.521
13
4205B–AUTO–12/04
VAN Protocol
Line Interface
There are three line inputs and one line output available on the TSS463AA. Which of the
three inputs to use is either programmable by software or automatically selected by a
diagnosis system.
The diagnosis system continuously monitors the data received through the three inputs,
and compares it with each other and the selected bitrate. It then chooses the most reliable input according to the results.
The data on the line is encoded according to the VAN standard ISO/11519-3. This
means that the TSS463AA is using a two level signal having a recessive (1) and a dominant (0) state. Furthermore, due to the simple medium used, all data transmitted on the
bus is also received simultaneously.
The VAN protocol is hence a CSMA/CD (Carrier Sense Multiple Access Collision Detection) protocol, allowing for continuous bitwise arbitration of the bus, and non-destructive
(for the higher priority messa ge) collision detection.
Figure 10. CSMA/CD Arbritration
Arbitration field
Node a: TxD
R
D
Node b: TxD
R
D
Node c: TxD
R
D
On Bus: DATA
R
D
2
Node a loses the arbitration
Node a releases the bus
3
1
R: Recessive Level
Node b wins the arbitration
Node c loses the arbitration
Node c releases the bus
D: Dominant Level
In addition to the VAN specification there is also a pulsed coding of the dominant and
recessive states. This mode is intended to be used with an optical or radio link. In this
mode, the dominant state for the transmitter is a low pulse, (2x prescaled clocks at the
beginning of the bit) and the recessive state is just a high level. When receiving in this
mode, it is not the state of the signal itself which is decoded, but the edges. Also, reception is imposed on the RxD0 input, and the diagnosis system does not operate correctly.
In addition, in this mode there is an internal loopback in the circuit since optical transceivers are not able to receive the signal that they transmit.
14
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
In Figure 11 the pulsed waveforms are shown. In Figure 14 through Figure 20 the low
"timeslots" (i.e. blocks of 16 prescaled clocks) should be replaced by the dominant
waveform showed in Figure 11 if the correct representations for pulsed coding are to be
seen.
Figure 11. State Encoding
VAN Frame
Figure 12. VAN Bus Frame
Identifier
Field
SOF
Command
EXT
RAK
R/W
RTR
Data
Field
Frame
Check
Sum
EOD
ACK
EOF
The VAN bus supports three different module (unit) types:
1. The Autonomous module, which is a bus master. It can transmit Start Of Frame
(SOF) sequences, it can initiate data transfers and can receive messages.
2. The Synchronous access module. It cannot transmit SOF sequences, but it can
initiate data transfers and can receive messages.
3. The Slave module, which can only transmit using an in-frame mechanism and
can receive messages.
Figure 13. Hierarchical Access Methods
Autonomous
Rank 0
SOF
ID
COM
DATA
FCS
EOD ACK
EOF
COM
DATA
FCS
EOD ACK
EOF
DATA
FCS
EOD ACK
EOF
Synchronous
Rank 1
ID
Rank 16
RTR
Slave
Figure 12 shows a normal VAN bus frame. It is initiated with a Start of Frame (SOF)
sequence shown in Figure 14. The SOF can only be transmitted by an autonomous
module. During the preamble, the TSS463AA will synchronize its bit rate clock to the
data received.
15
4205B–AUTO–12/04
Figure 14. Framing Sequences
VAN BUS
START
SYNC
PREAMBLE
SEQUENCE
START OF FRAME
VAN BUS
END OF
DATA
ACK
SEQUENCE
NUMBER OF
PRESCALED
CLOCKS
0
16
32
END OF FRAME
48
64
80
96
112 128 144
160 176 192
When the complete SOF sequence has been transmitted or received, the circuit will
start the transmission or reception of the identifier field.
All data on the VAN bus, including the identifier and Frame Check Sum (FCS), are
transmitted using enhanced Manchester code.
In enhanced Manchester code, three NRZ bits are transmitted first followed by one
Manchester bit, then three more NRZ bits followed by one Manchester bit and so on.
Since the high state is recessive and the low state is dominant, the bus arbitration can
be done. If a module wants access to the bus, it must first listen to the bus during one
full End of Frame (EOF) and one full Inter Frame Spacing (IFS) period to determine
whether the bus is free or not (i.e. no dominant states received).
Figure 15. Data Encoding
VAN BUS
SEQUENCE
NRZ 0
VAN BUS
SEQUENCE
MANCHESTER 0
VAN BUS
SEQUENCE
NUMBER OF
PRESCALED
CLOCKS
NRZ 1
MANCHESTER 1
0
8
16
24
32
The IFS is defined to be a minimum of 64 prescaled clock periods. The TSS463AA,
accepts an IFS of zero prescaled clocks for the reception only of a SOF sequence.
Once the bus has been determined as being free, the module must, if it is an autonomous module, emit an SOF sequence or, if it is a synchronous access module, wait until
it detects a preamble sequence.
At this point there could be several modules transmitting on the bus, and there is no
possibility of knowing if this is the case or not. Therefore, the first field in which arbitra16
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
tion can be performed is the identifier field. Since the logical zeroes on the bus are
dominant, and all data is transmitted with the most significant bit (MSB) first, the first
module to transmit a logical zero on the bus will be the prioritized module, i.e. the message that is tagged with the lowest identifier will have priority over the other messages.
It is possible that two messages transmitted on the bus will have the same identifier. The
TSS463AA, therefore, continues the arbitration of the bus throughout the whole frame.
Moreover, if the identifier in transmission has been programmed for reception as well, it
transmits and receives messages simultaneously, right up until the Frame Check
Sequence (FCS). Only then, if the TSS463AA has transmitted the whole message, it
discard the message received. Arbitration loss in the FCS field is considered as a CRC
error during transmission.
This feature is called full data field arbitration, and it enables the user to extend the identifier. For instance it can be used to transmit the emitting modules address in the first
bytes of the data field, thus enabling the identifier to specify the contents of the frame
and the data field to specify the source of the information.
The identifier field of the VAN bus frame is always 12 bits long, and it is always followed
by the 4-bit command field:
•
The first bit of the command is the extension bit (EXT). This bit is defined by the
user on transmission and is received and retained by the TSS463AA. To conform
with the standard it should be set to 1 (recessive) by the user, else the frame is
ignored without any IT generation.
•
The second bit is the request ACKnowledge bit (RAK). If this bit is a logical one, the
receiving module must acknowledge the transfer with an in-frame
acknowledgement in the ACK field. If it is set to logical zero, then the ACK field must
contain an acknowledge absent sequence.
•
The third bit is the Read/Write (R/W). This bit indicates the direction of the data in a
frame.
•
–
If set to zero, it is a "write" message, i.e., data transmitted by one module to
be received by another module.
–
If it is set to one, it implies a "read" message, i.e. a request that another
module should transmit data to be received by the one that requested the
data (reply request message).
Last in the command field is the Remote Transmission Request bit (RTR). This bit is
a logical zero if the frame contains data and a logical one if the frame does not
contain data. In order to conform with the standard, a received frame includes the
combination R/W. RTR = 01 is ignored without any IT generation.
All the bits in the command field are automatically handled by the TSS463AA, so the
user need not to be concerned for encoding and decoding of these bits. The command
bits transmitted on the VAN bus are calculated from the current status of the active
message.
The data field comes after the command field. This is just a sequence of bytes transmitted MSB first. In the VAN standard the maximum message length is set to 28 bytes, but
the TSS463AA handles messages up to 30 bytes.
The next field is the FCS field. This field is a 15 bit CRC checksum defined by the following generator polynomial g(x) of order 15:
g(x)= x15 + x11 + x10 + x9 + x8 + x7 + x4 + x3 + x2 + 1
The division is done with a rest initialized to 0x7FFF, and an inversion of the CRC bits is
performed before transmission.
17
4205B–AUTO–12/04
However, since the CRC is calculated automatically from the identifier, command and
data fields by the TSS463AA, therefore, the user should not be concerned with the circuit. When the frame check sequence has been transmitted, the transmitting module
must transmit an End of Data (EOD) sequence, followed by the ACKnowledge field
(ACK) and the End of Frame sequence (EOF) to terminate the transfer.
Figure 16. Acknowledge Sequences
VAN BUS
SEQUENCE
POSITIVE ACKNOWLEDGE
VAN BUS
SEQUENCE
NUMBER OF
PRESCALED
CLOCKS
Frame Examples
ABSENT ACKNOWLEDGE
0
8
16
24
32
The frames transmitted on the VAN bus are generated by several modules, each supplying different parts of the message. Figure 17 through Figure 20 show the four frame
types specified in the VAN standard, and the module that is generating the different
fields.
•
The most straightforward frame is the normal data frame in Figure 17. Like all other
frames, it is initiated with a SOF sequence. This sequence is generated by a bus
master (not shown in the figure).
During this frame, there is basically only one module transmitting with the exception of
the acknowledgement, generated by the receiving module if requested in the RAK bit.
•
The reply request frame with immediate reply in Figure 18 is the only frame in which
a slave module can transmit data by filling it into the appropriate field.
The only difference for the frame on the bus is that the R/W bit has changed state compared to the normal frame.
This is a highly interactive frame where a bus master generates the SOF and the initiator generates the identifier, the three first bits of the command, and the acknowledge.
The RTR bit, the data field, the frame check, the EOD and the EOF are all generated by
the replying module.
•
The reply request frame with deferred reply in Figure 19 is basically the same frame
as the reply request frame with immediate reply, but since the requested module
does not generate the RTR bit the requesting module will continue with the frame
check, the EOD and the EOF.
During this frame, the requested module will only generate the acknowledge, and only if
this was requested by the initiator through the RAK bit.
•
Finally, the deferred reply frame in Figure 20 which is sent when a module has
prepared a reply for a reply request that has been received earlier.
This frame very closely mimics the normal data frame with the exception is the R/W bit
that has changed state.
18
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Figure 17. Normal Data Frame
DATA
CRC
EOD
ACK
RTR
(*)
DATA
CRC
EOD
ACK
EOF
CRC
EOD
ACK
EOF
CRC
EOD
ACK
EOF
IDENTIFIER
SOF
IDENTIFIER
RECEIVING
module
FRAME
on bus
EOF
ACK
SOF
EXT
RAK
R/W
TRANSMITTING
module
EXT
RAK
R/W
RTR
(*)
With acknowledgment
EXT
RAK
R/W
RTR
ACK
:
:
:
:
:
Recessive from Transmitter
Recessive for acknowledge from Transmitter
Dominant from Transmitter
Dominant from Transmitter
- (*) Manchester bit
Positive from Receiver because RAK is Recessive
SOF
IDENTIFIER
EXT
RAK
R/W
RTR
(*)
TRANSMITTING
module
DATA
SOF
IDENTIFIER
EXT
RAK
R/W
RTR
(*)
Without acknowledgment
DATA
RECEIVING
module
FRAME
on bus
EXT
RAK
R/W
RTR
ACK
: Recessive from Transmitter
: Dominant for no acknowledge from Transmitter
: Dominant from Transmitter
: Dominant from Transmitter
- (*) Manchester bit
: Absent from Transmitter and from Receiver because RAK is Dominant
19
4205B–AUTO–12/04
EXT
RAK
R/W
RTR
ACK
:
:
:
:
:
IDENTIFIER
ACK
ACK
SOF
CRC
EOF
DATA
CRC
ACK
FRAME
on bus
DATA
EOD
REQUESTED
module
EOD
IDENTIFIER
RTR
(*)
SOF
EXT
RAK
R/W
RTR
(*)
REQUESTING
module
EXT
RAK
R/W
RTR
(*)
Figure 18. Reply Request Frame with Immediate Reply
EOF
Recessive from Requestor
Recessive for acknowledge from Requestor
Recessive from Requestor
Recessive from Requestor and Dominant from Requestee- (*) Manchester bit
Absent from Requestee and Positive from Requestor because RAK is Recessive
EOD
ACK
IDENTIFIER
CRC
REQUESTED
Module
FRAME
on Bus
EOF
ACK
SOF
CRC
ACK
IDENTIFIER
EOD
SOF
EXT
RAK
R/W
RTR
(*)
REQUESTING
Module
EXT
RAK
R/W
RTR
(*)
Figure 19. Reply Request Frame with Deferred Reply
EOF
EXT : Recessive from Requestor
RAK : Recessive for acknowledge from Requestor
R/W : Recessive from Requestor
RTR : Recessive from Requestor - (*) Manchester bit
ACK : Absent from Requestor and Positive from Requestee because RAK is Recessive
20
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
ACK
DATA
CRC
EOF
ACK
IDENTIFIER
CRC
ACK
SOF
DATA
EOD
IDENTIFIER
EOD
SOF
EXT
RAK
R/W
RTR
(*)
REPLYING
module
EXT
RAK
R/W
RTR
(*)
Figure 20. Deferred Reply Frame
RECEIVING
module
FRAME
on bus
EXT
RAK
R/W
RTR
ACK
:
:
:
:
:
EOF
Recessive from Replyer
Recessive for acknowledge from Replyer
Recessive from Replyer
- (*) Manchester bit
Dominant from Replyer
Absent from Replyer and Positive from Receiver because RAK is Recessive
21
4205B–AUTO–12/04
Diagnosis System
The purpose of the diagnosis system is to detect any short or open circuits on either the
DATA or DATA lines and to permit, if it is possible, to carry the communications on the
non-defective line.
The diagnosis system is based on the assumption that three separate line receivers are
connected to the VAN bus see Figure 1:
•
One of the line receivers is connected in differential mode, sensing both DATA and
DATA signals, and is connected to the RxD0 input.
•
The other two line receivers are operating in single wire mode and are sensing only
one of the two VAN bus signals:
–
The line receiver sensing DATA is connected to RxD1
–
The line receiver sensing DATA is connected to RxD2
The diagnosis system analyzes and compares the data sent over both VAN lines. So,
the diagnosis system executes a digital filtering and transition analyses. In order to perform its investigation, three internal signals are generated, RI (Return to Idle), SDC
(Synchronous Diagnosis Clock) and TIP (Transmission In Progress).
One of four operating modes can be chosen to manage the results of the diagnosis
system.
Diagnosis States
If the diagnosis system finds a failure on any of the VAN bus signals, it changes from
nominal to degraded mode, and connects the line receiver not coupled to the failing signal to the reception logic.
When the diagnosis system finds that the failing signal is working again, it returns to
nominal mode and re-connects the differential line receiver to the reception logic.
A major error occurs when both the VAN bus signals failed.
Figure 21. Diagnosis States
Nominal
Major
Error
Degraded
Data
Degraded
Data
- Failure during the frame
- Default of transitions on the valid input between 2 consecutive SDC rising edges.
- Protocol fault
-In specified selection mode, every RI pulse when an EOF is detected or through an active SDC.
-In automatic selection mode and SDC active, no failuresampled by 2 consecutive SDC rising edges.
-General Reset
22
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Status bits give permanent information on the diagnosis performed, whatever the programmed operating mode. This is encoded over three bits: Sa, Sb and Sc.
•
Sa and Sb bits indicate the four possible states of the VAN bus.
Table 3. Status Bits: Sa and Sb
Sa
0
0
1
1
•
Sb
0
1
0
1
Communication
Mode
Nominal
Fault
No fault on VAN bus
Status
Differential communication on DATA and DATA
Mode
Degraded on DATA
Fault
Fault on DATA
Status
Communication on DATA
Mode
Degraded on DATA
Fault
Fault on DATA
Status
Communication on DATA
Mode
Major error
Fault
Fault on DATA and DATA
Status
No communication on DATA and DATA (attempt to communicate
alternatively on DATA then DATA every SDC period)
Sc: As soon as one of the three inputs (RXD2, RXD1, RXD0) differs from the others
in the input comparison analysis performed by the diagnosis system, Sc is set.
The only way to reset this status bit is through the RI signal or a general reset.
Internal Operations
Digital Filtering
If several spurious pulses occur during one bit, the diagnosis for defective conductor
may occur. To avoid such errors, digital filters are implemented.
Filtering operation is based on sampling of the comparator output signals. A transition is
taken into account only if it is observed over five samples (1/16th of timeslot).
Transition Analyses
These analyses are continuously done on the effective edges on comparators after digital filtering.
•
Asynchronous diagnosis
The asynchronous diagnosis is done by comparing the number of edges on DATA
and DATA.
If four edges are detected on one input and no edges on the other during the same
period, the second input is considered faulty and the diagnosis mode will change to
one of the degraded modes.
•
Synchronous diagnosis
The synchronous diagnosis counts the number of edges on the data input
connected to the reception logic during one SDC period.
If there are less than four edges during one SDC period, the diagnosis mode will
change to the major error mode.
23
4205B–AUTO–12/04
•
Transmission diagnosis
The transmission compares RxD1 and RxD2 inputs (through the input comparators
and the filters) with the data transmitted on TxD output.
At a time when the transmission logic generates a dominant - recessive transition,
the inputs can give different values. Taking into account the filtering delay, the bus
line seen as dominant is assumed to be correct, the other one, recessive, is
considered faulty. The diagnosis mode is changed to reflect that.
•
Protocol fault
The protocol fault is detected by counting the number of consecutive dominant
timeslots.
If eight consecutive timeslots are dominant, the diagnosis mode will change to the
major error mode.
Generation of Internal
Signals
RI Signal (Return to Idle)
This signal is used to return to nominal mode in the three specified selection modes (see
“Diagnosis States” on page 22 and “Programming Modes” on page 25). The RI signal is
disabled in automatic selection mode.
The RI signal is a pulse generated when an EOF is detected. Thus, at the end of each
frame, regarding the diagnosis status bit Sa, Sb and Sc, the user can make its own
choice.
SDC Signal (Synchronous
Diagnosis Clock)
This time base is used by diagnosis system in automatic selection mode (see
Section “Programming Modes”, page 25) when no event is recorded on the bus.
The SDC is generated either by a special SDC divider connected to the timeslot clock,
or can be performed manually. The SDC clock period must be long compared to the
timeslot duration.
A typical SDC period should be greater than the maximum frame length appearing on
the VAN network.
TIP Signal (Transmission in
Progress)
This signal must be enabled to allow the transmission diagnosis (see Section “Transition
Analyses”, page 23).
The TIP turns on synchronously with the beginning of the transmission:
•
for asynchronous bus access, the beginning of SOF;
•
for synchronous bus access, the beginning of the identifier field; and
•
for a request of in frame reply, the RTR bit of the command field.
The TIP turns off synchronously with the end of the transmission:
•
after EOF;
•
after a losing of arbitration or a code violation detection; and
•
for a requestor of in frame reply, when the arbitration is lost on RTR the bit.
This signal is not generated when the transmission logic only sends an ACK.
24
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Programming Modes
Four programming modes determine how to use the three different inputs and the diagnosis system.
•
3 specified selection modes
•
1 automatic selection mode
Table 4. Programming Modes
Ma
Mb
Operating Mode
0
0
Differential communication
0
1
Degraded communication on RxD2 (DATA)
1
0
Degraded communication on RxD1 (DATA)
1
1
Automatic selection according the diagnosis status
25
4205B–AUTO–12/04
Registers
The TSS463AA memory map consists of three different areas, the Control and Status
registers, the Channel registers and the Message data (or Mailbox).
Mapping
Figure 22. Memory Map
0x78 to 0x7F (r/w)
Channel
13
Channel 13
0x70 to 0x77 (r/w)
Channel 12
0x68 to 0x6F (r/w)
Channel 11
0x60 to 0x67 (r/w)
Channel 10
0x58 to 0x5F (r/w)
Channel 9
0x50 to 0x57 (r/w)
Channel 8
0x48 to 0x4F (r/w)
Channel 7
0x40 to 0x47 (r/w)
Channel 6
0x38 to 0x3F (r/w)
Channel 5
0x30 to 0x37 (r/w)
Channel 4
0x28 to 0x2F (r/w)
Channel 3
0x20 to 0x27 (r/w)
Channel 2
0x18 to 0x1F (r/w)
Channel 1
0x10 to 0x17 (r/w)
Channel 0
0x0C to 0x0F
Reserved
Interrupt Reset
Interrupt Enable (0x80)
Interrupt Status (0x80)
Reserved
0x0B (w)
0x0A (r/w)
0x09 (r)
0x08
0x07 (r)
0x06 (r)
0x05 (r)
0x04 (r)
0x03 (w)
0x02 (r/w)
0x01 (r/w)
Last Error Status (0x00)
Last Message Status (0x00)
Transmit Status (0x00)
Line Status (0bx01xxx00)
Command (0x00)
Diagnosis Control (0x00)
Transmit Control (0x02)
0x00 (r/w)
Line Control (0x00)
Register
Notes:
26
0xFF
0x7F (r/w)
0x7E (r/w)
Data Byte 127
ID_Mask [3..0]
ID_Mask [11..4]
0x7C and 0x7D Reserved
Reserved
0x7B (r/w) Message Length + Status
0x7A (r/w) DRAK + Message Address
0x79 (r/w)
ID_TAG (lsb) + COM
0x78 (r/w)
ID_TAG (msb)
Channel 13 Registers
0x17 (r/w)
0x17 (r/w)
ID_Mask [3..0]
0x16 (r/w)
ID_Mask
[11..4]
ID_Mask [11..4]
0x14 and 0x15 Reserved
0x13 (r/w) Message Length + Status
0x12 (r/w) DRAK + Message Address
0x11 (r/w) ID_TAG [3..0] + COM
0x10 (r/w)
ID_TAG [11..4]
Channel 0 Registers
0x8C
0x8B
0x8A
0x89
0x88
0x87
0x86
0x85
0x84
0x83
0x82
0x81
0x80
Data Byte 12
Data Byte 11
Data Byte 10
Data Byte 9
Data Byte 8
Data Byte 7
Data Byte 6
Data Byte 5
Data Byte 4
Data Byte 3
Data Byte 2
Data Byte 1
Data Byte 0
Message
1. All the non-specified addresses between 0x00 and 0x7F are considered as absent.
2. (r) means read-only register.
(w) means write-only register.
(r/w) means read/write register.
3. Value after RESET is found after register name. If no value is given, the register is not initialized at RESET.
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Control and Status Registers
Line Control Register (0x00)
CD[3:0]:Clock Divider
7
6
5
4
3
2
1
0
CD3
CD2
CD1
CD0
PC
0
IVTX
IVRX
•
Read/write register.
•
Default value after reset: 0×00
•
Reserved: Bit 2, this bit must not be set by the user; a 0 must always be written to
this bit.
They control the VAN Bus rate through a Baud Rate generator according to the formula
below:
f ( XTAL1 )
f ( TSCLK ) = ------------------------n × 16
PC: Pulsed Code
One: The TSS463AA will transmit and receive data using the pulsed coding mode (i.e
optical or radio link mode). The use of this mode implies communication via the RxD0
input and the non-functionality of the diagnosis system.
Zero: (Default at reset). The TSS463AA will transmit and receive data using the
Enhanced Manchester code. (RxD0, RxD1, RxD2 used).
IVTX: Invert TxD output
IVRX: Invert RxD inputs
The user can invert the logical levels used on either the TxD output or the RxD inputs in
order to adapt to different line drivers and receivers.
One: A one on either of these bits will invert the respective signals.
Zero: (Default at reset). The TSS463AA will set TxD to recessive state in Idle mode and
consider the bus free (recessive states on RxD inputs).
Transmit Control Register
(0x01)
7
6
5
4
3
2
1
0
MR3
MR2
MR1
MR0
VER2
VER1
VER0
MT
Read/Write register.
Default value after reset: 0x02
MR[3:0]: Maximum Retries
These bits allow the user to control the amount of retries the circuit will perform if any
errors occurred during transmission.
27
4205B–AUTO–12/04
Table 5. Retries
Note:
VER[2:0] = 001
MR [3:0]
Max. # of retries
Max. # of transmissions
0000
0
1
0001
1
2
0010
2
3
0011
3
4
0100
4
5
0101
5
6
0110
6
7
0111
7
8
1000
8
9
1001
9
10
1010
10
11
1011
11
12
1100
12
13
1101
13
14
1110
14
15
1111
15
16
Bus contention is not regarded as an error and an infinite number of transmission
attempts will be performed if bus contention occurs continuously.
DLC Version after reset.
These bits must not be set by user. 001 must always be written to these bits.
MT: Module type
The three different module types are supported (see “VAN Frame” on page 15):
One: The TSS463AA is at once an autonomous module (Rank 0), a synchronous
access module (Rank 1) or a slave module (Rank 16).
Zero: The TSS463AA is at once an synchronous access module (Rank 1) or a slave
module (Rank 16).
28
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Diagnosis Control Register (0x02)
7
6
5
4
3
2
1
0
SDC3
SDC2
SDC1
SDC0
Ma
Mb
ETIP
ESDC
•
Read/Write register
•
Default value after reset: 0×00.
The diagnosis is discussed in greater detail in the section “Diagnosis System” on page
22.
•
In its four high order bits, the user can program the SDC rate SDC [3:0]
•
In its two medium order bits, the diagnosis system mode is controlled: M1, M0.
•
In the two low order bits, the user controls if the SDC and TIP are to be generated
automatically ETIP, ESDC.
SDC [3:0]: SDC divider
The input clock is the timeslot clock.
Table 6. System Diagnosis Clock Divider
SDC DIVIDER SDC [3:0]
Divide by
0000
64
0001
128
0010
256
0011
512
0100
1024
0101
2048
0110
4096
0111
8192
1000
16384
1001
32768
1010
65536
1011
131072
1100
262144
1101
524288
1110
1048576
1111
2097152
SDC calculation: (see “SDC Signal (Synchronous Diagnosis Clock)” on page 24).
Notes:
1. For each module, determine the largest interframe spacing, LIFS (*).
2. For the whole network, get the maximum LIFS, MAX-LIFS.
3. SDC period > MAX-LIFS.
(*) IFS min. = 4 TS
Example: For VAN frame speed rate = 62,5 KTS/s (1 TS = 16 µs), SDC >100 ms
=> 100 ms / 16 µs = 6250, divider chosen: 8192, SDC [3:0] = 0111.
29
4205B–AUTO–12/04
Ma, Mb: Operating Mode
Command Bits
ETIP: Enable Transmission In
Progress
Table 7. Diagnosis System Command Bits
Ma
Mb
0
0
Forces the Communication on RxD0 (differential)
0
1
Forces the Communication on RxD2 (DATA)
1
0
Forces the Communication on RxD1 (DATA)
1
1
Automatic selection
The Transmission In Progress (TIP) tells the diagnosis system to enable transmission
diagnosis.
One: Enable TIP generation
Zero: Disable TIP generation.
ESDC: Enable System
Diagnosis Clock
The Synchronous Diagnosis Clock (SDC) controls the cycle time of the synchronous
diagnosis.
One: Enable SDC divider.
Zero: Disable SDC divider.
Command Register (0x03)
GRES: General Reset
7
6
5
4
3
2
1
0
GRES
SLEEP
IDLE
ACTI
REAR
0
0
MSDC
•
Write only register.
•
Reserved: Bit 1, 2 these bits must not be set by the user; a zero must always be
written to these bit.
•
If the circuit is operating at low bitrates there might be a considerable delay between
the writing of this register and the performing of the actual command (worst case 6
timeslots). The user is therefore recommended to verify, by reading the Line Status
Register (0x04), that the commands have been performed.
The Reset circuit command bit performs, if set, exactly as if the external reset pin was
asserted. This command bit has its own auto-reset circuitry.
One: Reset active
Zero: Reset inactive
SLEEP: Sleep Command
(See Section “Sleep Command”, page 52).If the user sets the Sleep bit, the circuit will
enter sleep mode. When the circuit is in sleep mode, all non-user registers are setup to
minimize power consumption. Read/write accesses to the TSS463AA via the SPI/SCI
interface are impossible, the oscillator is stopped.
To exit from this mode the user must apply either an hardware reset (external RESET
pin) or an asynchronous software reset (via the SPI/SCI interface).
One: Sleep active
Zero: Sleep inactive
30
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
IDLE: Idle Command
(See Section “Idle and Activate Commands”, page 52). If the user sets the Idle bit, the
circuit will enter idle mode. In idle mode the oscillator will operate, but the TSS463AA
will not transmit or receive anything on the bus, and the TxD output will be in three state.
One: Idle active
Zero: Idle inactive
ACTI: Activate Command
(See Section “Idle and Activate Commands”, page 52). The Activate command will put
the circuit in the active mode, i.e it will transmit and receive normally on the bus. When
the circuit is in activate mode the TxD three-state output is enabled.
One: Activate active
Zero: Activate inactive
REAR: Re-Arbitrate Command
This command will, after the current attempt, reset the retry counter and re-arbitrate the
messages to be transmitted in order to find the highest priority message to transmit.
One: Re-arbitrate active
Zero: Re-arbitrate inactive
MSDC: Manual System
Diagnosis Clock
Rather than using the SDC divider described in Section “Message Data (string pointed
by: Message Pointer Register + 1)”, page 44, the user can use the manual SDC command to generate a SDC pulse for the diagnosis system.
This MSDC pulse should be high at least 2 timeslot clocks.
Line Status Register (0x04)
7
6
5
4
3
2
1
0
X
SPG
IDG
Sc
Sb
Sa
TXG
RXG
•
Read only register
•
Default value after reset: 0bx01xxx00.
•
This register reports the operation mode of the TSS463AA in the Sleep an Idle bits
(Command Register located at address 0×03) as well as the diagnosis system
status bits Sa to Sc discussed in the section “Diagnosis System” on page 22.
SPG: Sleeping
IDG: Idling
Default mode at reset
Sa, Sb and Sc: Diagnosis
System Status Bits
•
Sa and Sb
Diagnosis System Status Bits
Sb
Sa
Communication Indication
0
0
Nominal mode, differential communication
0
1
Degraded over DATA, fault on DATA
1
0
Degraded over DATA, fault on DATA
1
1
Major error, fault on DATA and DATA
31
4205B–AUTO–12/04
•
Sc: As soon as one of the three inputs (RxD2, RxD1, RxD0) differs from the others
in the input comparison analysis performed by the diagnosis system, Sc is set.
The only ways to reset this status bits through the RI signal or a general reset.
TXG: Transmitting
If this status bit is active, it indicates that the TSS463AA has chosen an identifier to
transmit, and it will continue to make transmission attempt for this message until it succeeds or the retry count is exceeded.
RXG: Receiving
The receiving indicates that there is activity on the bus.
Note: For safe modification of active channel registers both bits should be inactive
(except “abort” command).
Transmission Status Register
(0x05)
7
6
5
4
3
2
1
0
NRT3
NRT2
NRT1
NRT0
IDT3
IDT2
IDT1
IDT0
•
Read only register.
•
Default value after reset: 0x00.
•
The transmission Status register contains the number of retries made up-to-date,
according tothe table above, and the channel currently in transmission.
NRT [3:0]:
Number of retries done in transmission.
IDT [3:0]:
Channel number currently in transmission.
Last Message Status Register
(0x06)
7
6
5
4
3
2
1
0
NRTR3
NRTR2
NRTR1
NRTR0
IDTR3
IDTR2
IDTR1
IDTR0
•
Read only register.
•
Default value after reset: 0x00.
•
This register is basically the same as the transmission status register. It contains the
last identifier number that was successfully transmitted, received or exceeded its
retry count.
If it was a successful transmission, the number of retries performed can be seen in
this register as well.
NRTR [3:0]:
Number of retries done successfully in transmission. In case of reception NRTR[3:0] is
undefined.
IDTR [3:0]:
Channel number that was successfully transmitted, received or exceeded its retry count.
32
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Last Error Status Register (0x07)
BOC: Buffer Occupied
7
6
5
4
3
2
1
0
X
BOC
BOV
X
FCSE
ACKE
CV
FV
•
Read only register.
•
Default value after reset: 0×00.
•
The Last Error Status Register contains the error code for the last transmission or
reception attempt. It is updated after each attempt, i.e., several error codes can be
reported during one single transmission (with several retries).
•
when one channel configured in “Reply request” mode has its “received” bit set
when it attempts to transmit its request.
•
BOC with the link capability between two channels sharing the same received
buffer, is set when one channel has already set its “received” bit in its “Message
length and status Channel register” and a receive is attempt on the other one.
One: BOC active
Zero: BOC inactive
BOV: Buffer Overflow
BOV indicates that the buffer length setup in the Channel Status Register was shorter
than the number of bytes received plus 1, and thus, some data was lost.
One: BOV active
Zero: BOV inactive
FCSE: Framing Check
Sequence Error
FCSE indicates a mismatch between the FCS received and the FCS calculated
ACKE: Acknowledge Error
ACKE indicates a physical violation or collision on ACK field of the frame when the
TSS463AA is a producer.
One: FCSE active
Zero: FCSE inactive
One: ACKE active
Zero: ACKE inactive
33
4205B–AUTO–12/04
Figure 23. ACKE Status bit
RAK = 0
DLC: Producer
EOD field
ACK field
Expected
ACKE = 0
Received
ACKE = 1
Received
ACKE = 1
Received
ACKE = 1
RAK* = 1
*RAK: Bit of the Frame COMMAND Field
EOD field
CV: Code Violation
ACK field
Expected
ACKE = 0
Received
ACKE = 1
Received
ACKE = 1
Received
ACKE = 1
CV indicates:
•
either a Manchester code violation (2 identical TS on Manchester bit), or a physical
violation (transmitted bit “dominant”, received bit “recessive”), on fields ID, COM,
DATA and CRC.
•
or a physical violation or collision on field “preamble” and the “recessive” bit of the
“Star Sync” field.
One: CV active
Zero: CV inactive
FV: Frame Violation
FV indicates a physical violation or collision on ACK field of the frame when the
TSS463AA is a consumer.
One: FV active
Zero: FV inactive
34
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Figure 24. FV Status Bit
DLC: Consumer
EOD field
ACK field
Expected
FV = 0
Received
FV = 1
Received
FV = 1
Received
FV = 1
EOD field
ACK field
Expected
FV = 0
Received
FV = 1
Received
FV = 1
Received
FV = 1
Interrupt Status Register (0x09)
RST: Reset Interrupt
7
6
5
4
3
2
1
0
RST
X
X
TE
TOK
RE
ROK
RNOK
•
Read only register.
•
Default value after reset: 1xx0 0000
RE indicates that the circuit has detected a valid reset command via the RESET pin or
the reset command bit GRES. This interrupt cannot be disabled, since its enable bit is
set when a reset is detected.
One: Status flag activated
Zero: No status flag.
TE: Transmit Error Status Flag
(or Exceeded Retry)
This flag is set only when the Max number of transmission (1 + MR [3:0]) is reached with
error of transmission.
One: Status flag activated
Zero: No status flag.
Figure 25. Exceeded Retry with MR[3..0] = 3
1st TX
2nd TX
3rd TX
set TE
set CHER
set CHTx
35
4205B–AUTO–12/04
TOK: Transmit OK Status Flag
One: Status flag activated
Zero: No status flag.
RE: Receive Error Status Flag
One: Status flag activated
Zero: No status flag.
ROK: Receive “with RAK
(RAK=1)” OK Status Flag
One: Status flag activated
Zero: No status flag.
RNOK: Receive “with no RAK
(RAK=0)” OK Status Flag
One: Status flag activated
Zero: No status flag.
Interrupt Enable Register (0x0A)
7
6
5
4
3
2
1
0
1
X
X
TEE
TOKE
REE
ROKE
RNOKE
•
Read/write register.
•
Default value reset: 1xx0 0000
Note:
On reset the Reset Interrupt Enable bit is set to 1 instead of 0, as is the general rule.
TEE: Transmit Error Enable
One: IT enabled.
Zero: IT disabled.
TOKE: Transmission OK Enable
One: IT enabled.
Zero: IT disabled.
REE: Reception Error Enable
One: IT enabled.
Zero: IT disabled.
ROKE: Reception “with RAK”
OK Enable
One: IT enabled.
Zero: IT disabled.
RNOKE: Reception “with no
RAK” OK Enable
One: IT enabled.
Zero: IT disabled.
Interrupt Reset Register (0x0B):
36
7
6
5
4
3
2
1
0
RSTR
0
0
TER
TOKR
RER
ROKR
RNOKR
•
Write only register.
•
Reserved bit: 5 and 6. This bit must not be set by user; a zero must always be
written to this bit.
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
RSTR: Reset Interrupt Reset
One: Status flag reset.
Zero: Status flag unchanged.
TER: Transmit Error Status Flag
Reset
One: Status flag reset.
Zero: Status flag unchanged.
TOKR: Transmit OK Status Flag
Reset
One: Status flag reset.
Zero: Status flag unchanged.
RER: Receive Error Status Flag
Reset
One: Status flag reset.
Zero: Status flag unchanged.
ROKR: Receive “with RAK” OK
Status Flag Reset
One: Status flag reset.
Zero: Status flag unchanged.
RNOKR: Receive “with no RAK”
OK Status Flag Reset
One: Status flag reset.
Zero: Status flag unchanged.
Figure 26. Update of the Status Register
Flag
Flag
Write
Flag
Flag
Write
Write
REE
TOKR
ID+COM+DATA+CRC
4 TS
ROKE
RER
Interrupt Status
Register
1 to 2 TS
Pin 3
RNOKE
ROKR
Interrupt Enable
Register
Reset
RNOKR Interrupt
Register
6 TS
Set RXG
Set TXG
BUS
TOKE
RNOK
INT
Write
TER
SOF
ROK
Flag
Write
TEE
RSTR
RE
Reset RXG, TXG
Internal
RESET
TOK
ACK
TE
EOD
RST
INT
Line Status Register (0x04)
4 TS
Write “IT Status Register”
Write “Last error Register”
Write “Last message Register”
Write “Message Status”
Write “Message Length and Status Register”
37
4205B–AUTO–12/04
Channel Registers
There is a total of 14 channel register sets, each occupying 8 bytes for addressing simplicity, integrated into the circuit. Each set contains two 2 x 8-bit registers for the
identifier tag, identifier mask and command fields plus two 1 x 8-bit registers for DMA
pointers and message status.
The base_address of each set is:
(0x10 + [0x08 * channel_number]).
When the TSS463AA is reset either via the external RESET pin or the general reset
command, the channel registers are not affected. That is, on power-up of the circuit, all
the channel registers start with random values.
Due to this fact, the user should take care to initialize all the channel registers before
exiting from idle mode. The easiest way to disable a channel register is to set the
received and transmitted bits to 1 in the Message Length and Status Register.
Table 8. Channel Register Sets Map
Channel Number
from
to
Channel Number
from
to
6
0x40
0x47
13
0x78
0x7F
5
0x38
0x3F
12
0x70
0x77
4
0x30
0x37
11
0x68
0x6F
3
0x28
0x2F
10
0x60
0x67
2
0x20
0x27
9
0x58
0x5F
1
0x18
0x1F
8
0x50
0x57
0
0x10
0x17
7
0x48
0x4F
Table 9. Channel Register Set Structure
38
Reg. Name
Offset
Bit 7
Bit 6
Bit 5
Bit 4
ID_MASK
0x07
ID_MASK
0x06
(No register)
0x05
x
x
x
x
(No register)
0x04
x
x
x
x
MESS_L/
STA
0x03
MESS_PTR
0x02
ID_TAG/
CMD
0x01
ID_TAG
0x00
ID_M [3:0]
Bit 3
Bit 2
Bit 1
bit 0
x
x
x
x
x
x
x
x
x
x
x
x
CHER
CHTx
CHRx
RAK
RNW
RTR
ID_M [11:4]
M_L [4:0]
DRACK
M_P [6:0]
ID_T [3: 0]
EXT
ID_T [11:4]
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Identifier Tag and Command
Registers
The identifier tag and command registers are located at the base_address and
base_address + 1. It allows the user to specify the full 12-bit identifier field of the ISO
standard and the 4-bit command.
•
7
6
5
4
3
2
1
0
ID_T 3
ID_T 2
ID_T 1
ID_T 0
EXT
RAK
RNW
RTR
7
6
5
4
3
2
1
0
ID_T 11
ID_T 10
ID_T 9
ID_T 8
ID_T 7
ID_T 6
ID_T 5
ID_T 4
base_address
+ 0x01
base_address
+ 0x00
Read/Write registers.
ID_T [11:0]: Identifier Tag
Upon a reception hit (i.e, a good comparison between the identifier received and an
identifier specified, taking the comparison mask into account, as well as a status and
command indicating a message to be received), the identifier tag bits value will be
rewritten with the identifier bits actually received.
EXT, RAK, RNW and RTR
(See Section “Message Types”, page 45). No comparison will be done on the command
bits, except on EXT bit. The RAK, RNW and RTR bits will be written into the first byte of
the Message upon a reception hit.
The RNW and RTR bits, as well as the status bits in the length and status register, must
be in a valid position for reception or transmission. If not, the message corresponding to
this identifier is considered as inactive or invalid.
The way of knowing if an acknowledge sequence was requested or not is to check the
first byte of the Message.
Message Pointer Register
The message pointer register at address (base_address + 0x02) is 8 bits wide. It indicates where in the Message DATA RAM area the message buffer is located.
•
DRAK: Disable RAK (Used in
‘Spy Mode’)
7
6
5
4
3
2
1
0
DRAK
M_P 6
M_P 5
M_P 4
M_P 3
M_P 2
M_P 1
M_P 0
base_address
+ 0x02
Read/Write register.
In reception: whatever is the RAK bit of the incoming valid frame, no ACK answer will be
set. If the message was successfully received, an IT is set (ROK or RNOK).
In transmission: no action.
One: disable active, “spy mode”.
Zero: disable inactive, normal operation.
M_P [6:0]: Message Pointer
Since the Message DATA RAM area base address is 0x80, the value in this register is
the offset from that address. If the message buffer length value is illegal (i.e. zero), this
register is redefined as being a link pointer, thus containing the channel number of the
channel that contains the actual message pointer, message length and received status.
However, the identifier, mask, error and transmitted status used will be that of the originally matched channel. In any case, if a link is intended, the three high bits of M_P [6:0]
should be set to 0.
39
4205B–AUTO–12/04
This allows several channels to use the same actual reception buffer in Message DATA
RAM, thus diminishing the memory usage.
Note:
Message Length And Status
Register
The message length and status register at address (base_address + 0x03) is also 8 bits
wide. It indicates the length of reserved for the message in the Message DATA RAM
area.
•
M_L [4:0]: Message Length
Only 1 level of link is supported.
7
6
5
4
3
2
1
0
M_L 4
M_L 3
M_L 2
M_L 1
M_L 0
CHER
CHTx
CHRx
base_address
+ 0x03
Read/Write register.
The 5 high bits of this register allows the user to specify either the length of the message
to be transmitted, or the maximum length of a message receivable in the pointed reception buffer.
Note: The first byte in this register does not contain data, but the length of the message
received. This implies that the length value has to be equal to or greater than the maximum length of a message to be received in this buffer (or the length of a message to be
transmitted) plus 1, thus allowing a maximum length of 30 bytes and a minimum length
of 0 byte.
If the value of this field is “illegal” (i.e 0x00) then this message pointer is defined as
being a link (see Message pointer and register and “Linked Channels” on page 53).
Note:
CHER: Channel Error Status
and Abort Command
M_L [4:0] = 0x00
Linked channel
M_L [4:0] = 0x01
Frame with no DATA field (*)
M_L [4:0] = 0x02
Frame with 1 DATA byte
-------
----------------------
M_L [4:0] = 0x1D
Frame with 28 DATA bytes
M_L [4:0] = 0x1E
Frame with 29 DATA bytes
M_L [4:0] = 0x1F
Frame with 30 DATA bytes
Different of a reply request frame with no in-frame reply (deferred reply).
As status, this bit is set by the TSS463AA when error occurs in transmission or on a
received frame. The user must reset it.
To abort the transmission defined in the channel, this bit can be set to 1 by the user (see
Section “Activate, Idle and Sleep Modes”, page 52 and “Abort” on page 50).
CHTx: Channel Transmitted and
Transmit Enable Command
CHRx: Channel Received and
Receive Enable Command
40
The 2 low order bits of this register contain the message status. Together with the RNW
and RTR bits of the command register (base_address + 0x01), they define the message
type of this channel (see section “Message Types” on page 45). As a general rule, the
status bits are only set by the TSS463AA, so the user must reset them to perform a
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
transmission (CHTx) or/and a reception (CHRx). The received and transmitted bits are
only set if the corresponding frame is without errors or if the retry count has been
exceeded.
Identifier Mask Registers
The Identifier Mask registers (base_address + 0x06 and base_address + 0x07) allow
bitwise masking of the comparison between the identifier received and the identifier
specified.
•
ID_M [11:0]: Identifier Mask
7
6
5
4
3
2
1
0
ID_M 3
ID_M 2
ID_M 1
ID_M 0
x
x
x
x
7
6
5
4
3
2
1
0
ID_M 11
ID_M 10
ID_M 9
ID_M 8
ID_M 7
ID_M 6
ID_M 5
ID_M 4
base_address
+ 0x07
base_address
+ 0x06
Read/Write registers.
A value of 1 indicates comparison enabled.
A value of 0 indicates comparison disabled.
Example:
–
ID_M[11:0] = 0x0FF8
–
Acceptance: ID’s from 0x0FF8 up to 0x0FFF
41
4205B–AUTO–12/04
Mailbox
The mailbox contains all the messages received or to be transmitted. Each messages is
link to a channel. The Mailbox RAM area has 128 bytes and is mapped from 0x80 to
0xFF (see Section “Mapping”, page 26 ).
The message (or message buffer) is composed of:
•
1 byte of message status (only used in receiving),
•
n bytes of data. These data are the bytes of the DATA field of the frame with the
same organization.
The message is pointed by the Message Pointer Register of the channel, the length of
the message is given by the Message Length and Status Register of the channel. This
area is a pure RAM, it contains a random value after reset.
Figure 27. Message Buffer Structure for Reception
Message Length and Status Register
Message Pointer Register
CHER CHTx CHRx
( M_L >= n + 2 )
M_L [4..0]
M_P [6..0]
DRAK
Message
Received DATA n
M_P + 0x80 + n + 2
Received DATA 0
DATA n
FCS
ACK
DATA 0
M_P + 0x80
EOD
ID [11..0]
RTR
SOF
EXT
RAK
RNW
RAK RNW RTR
M_L [4..0] = n+1
receivedreceivedreceived
received
EOF
Received DATA Frame, immediate or deffered reply
42
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Figure 28. Message Buffer Structure for Transmission
Message Length & Status Register
Message Pointer Register
CHER CHTx CHRx
M_L [4..0]
DATA n
Transmitted
DATA 0
M_P + 0x80 + n + 2
RTR
RNW
EXT
RAK
ID [11..0]
M_P + 0x80
DATA 0
FCS
DATA n
ACK
Transmitted
EOD
( M_L >= n + 2 )
Message
(Nothing)
SOF
M_P [6..0]
DRAK
EOF
Transmitted DATA Frame
Message Status (Pointed
by: Message Pointer
Register)
•
7
6
5
4
3
2
1
0
RRAK
RRNW
RRTR
RM_L4
RM_L3
RM_L2
RM_L1
RM_L0
(no significant value in case of message to be transmitted)
RRAK: Received RAK Bit
This bit is the RAK bit coming from the COM field of the received frame.
RRNW: Received RNW Bit
This bit is the RNW bit coming from the COM field of the received frame.
RRTR: Received RTR Bit
This bit is the RTR bit coming from the COM field of the received frame.
RM_L[4:0]: Message Length of
the Received Frame
If the DATA field of the received frame included DATA0 to DATAn, RM_L[4:0] = n+1,
even if the reserved length (Message Length and Status Register) is larger.
43
4205B–AUTO–12/04
Figure 29. Message Status Updating
Frame Type
Node x
Communication
Node A
I, P
C
Data Frame
Immediate
Reply
Deferred
Reply
Message Status on Node A after IT(*)
I, C
RAK
RNW
RTR
RAK
RNW
RTR
RAK
RNW
RTR
length
P
I, C
previous
value
P
C
previous
value
I, P
Data Frame
previous values
P
Immediate
Reply
I, C
P
Deferred
Reply
P: Producer
RAK
RNW
RTR
length
RAK
RNW
RTR
length
I, C
I: Initiator
C: Consumer
(*) After IT ROK or RNOK. In case of IT RE, the values can be erroneous.
Message Data (string
pointed by: Message
Pointer Register + 1)
7
6
5
4
3
2
1
0
---
---
-- - -
---
DATAn
---
---
---
--DATA0
DATA0 is the first received (or transmitted) byte, DATAn is the last one.
Note:
1. If the length reserved (in the message length and status register) for an incoming
frame is 2 bytes greater or more, the TSS463AA will write the 2 bytes of the CRC
field in the message string just after DATAn.
Because the VAN frame does not content a message length, the only way for the
component to know the length of the DATA field is either the message length register
value, either the EOD field detection. When the reserved length is too large, at the
moment when it detects the EOD, the TSS463AA has already written the 2 bytes of
the CRC field, considering these bytes as normal DATA.
2. The Mailbox RAM area is a circular buffer. The next location after 0xFF is 0x80.
44
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Message Types
There are 5 basic message types defined in the TSS463AA. Two of them (transmit and
receive message types) correspond to the normal frame, and the rest correspond to the
different versions of reply frames.
Transmit Message
RNW
RTR
CHTx
CHRx
Initial setup
0
0
0
Don’t care
After transmission
0
0
1
Unchanged
To transmit a normal data frame on the VAN bus, the user must program an identifier as
a Transmit Message. The TSS463AA will then transmit this message on the bus until it
has succeeded or the retry count is exceeded.
Receive Message
RNW
RTR
CHTx
CHRx
Initial setup
0
1
Don’t care
0
After transmission
0
1
Unchanged
1
The opposite of the transmit message type is the Receive Message type. This message
type will not generate any frames on the bus. Instead it will listen to the bus until a frame
passes that matches its identifier, with the mask taken into account, and then receive
the data in that frame.
The data received will be stored in the message buffer and the length of the message
received is stored in the first byte of the message buffer.
The actual identifier received is stored in the identifier register itself. This identifier may
differ from the identifier specified in the register due to the effect of the mask register.
Normally this should not interfere with the next identifier comparison since the bits that
may differ are masked via the mask register.
Reply Request Message
RNW
RTR
CHTx
CHRx
Initial setup
1
1
0
0
After transmission
(Waiting for reply)
1
1
1
0
After reception
(of reply)
1
1
1
1
The Reply Request Message type is a demand to transmit on the VAN bus a reply
request. When this message type is programmed, three things can happen.
In the first case no other modules on the bus responded with an in-frame reply, and in
this case the TSS463AA will set the message type to the after transmission state. When
this message type is programmed, the TSS463AA will listen on the bus for a deferred
reply frame matching this identifier, without transmitting the reply request.
45
4205B–AUTO–12/04
The second case is that another module on the bus replies with an in-frame reply. In this
case the message type will pass immediately into the after reception state, without passing the after transmission state.
Reply Request Message without transmission
RNW
RTR
CHTx
CHRx
Initial setup
1
1
Don’t care
0
After reception
1
1
Unchanged
1
In the third case the TSS463AA has not yet started to transmit the reply request, when
another module either requests a reply, and gets it, or transmits a deferred reply. Warning! This should be avoided as it may result in an illegal message type (Illegal reply
Request).
Immediate Reply Message
RNW
RTR
CHTx
CHRx
Initial setup
1
0
0
0
After transmission
1
0
1
1
The immediate Reply Message will attempt to transmit an in-frame reply, using the data
in the message buffer.
Deferred Reply Message
RNW
RTR
CHTx
CHRx
Initial setup
1
0
0
1
After reception
(of reply request)
1
0
1
1
Above a Deferred Reply Message is shown. This message type will immediately transmit a deferred reply frame.
Reply Request Detection Message
RNW
RTR
CHTx
CHRx
Initial setup
1
0
1
0
After reception
1
0
1
1
Finally there is the Reply Request Detector Message type. Its purpose is to receive a
reply request frame and notify the processor, without transmitting an in-frame reply.
Inactive Message
RNW
RTR
CHTx
CHRx
Recommended
Don’t care
Don’t care
1
1
After transmission
0
0
1
Don’t care
After reception
0
1
Don’t care
1
Illegal reply request
1
1
0
1
The table above shows all inactive messages types. The last combination will transmit a
reply request, but will not receive the reply since its buffer is tagged as occupied.
46
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Priority Among the
Different Channels
The priority handling on the VAN bus itself is already explained in the Line interface section. The priorities for the messages in the TSS463AA is however slightly different.
For instance, it’s possible that an identifier matches two or more of the identifiers programmed into the registers. In this case, it is the lowest identifier number that has
priority. i.e., if both identifier 5 and 10 match the identifier received, it is the identifier 5
that will receive the message.
However, since the identifier 5 will become an inactive message when it has received
the frame, the next time the same identifier is seen on the bus, the corresponding data
will be received by identifier 10.
The same is valid for messages to be transmitted, i.e. if two or more messages are
ready to be transmitted, it is the one with the lowest identifier number that will get
priority.
Retries, Rearbitrate and
Abort
Retries and rearbitrate commands are located, respectively, in the Transmit Control
Register and in the Command Register. An abort command is located in each channel
register set, in the Message Length and Status Register (base_address + 0x03). These
three commands are available only when the TSS463AA is a producer.
Figure 30. Transmit Function
Activate
Ch. Enabled in
Xmit Mode ?
No
Yes
Select the Lowest
Disable of
Ch. Number and
Load ”Max - Retries”
Current Ch.
Yes
Abort Activated
on Current Ch. ?
No
Wait for Bus Free
(EOF+IFS= 12 Timeslots)
Decrement
Transmit Frame
Retry Counter
and Wait for the End
Abort Required
on Current Ch.
Rearbitrate?
Abort
Rearbitrate
no
Yes
Retry Needed ?
No
47
4205B–AUTO–12/04
Retries
The purpose of the retries feature is to provide, for the user, the capability of retrying a
transmit request in case of failure, when a node tries to reach another node, either on
normal DATA frame or on REPLY REQUEST frame.
The maximum number of retries is programmable through MR[3:0] of the Transmit Control Register (0x01). When a channel is enable – bit CHTx = 0 of Message Length and
Status Register, a 4-bit counter is loaded with MR[3:0]. At each attempt, this counter will
count-down to 0, an IT TE is set in the Interrupt Status Register (0x09), and the transmission is stopped.
MR[3:0] = 1 indicates 1 retry, hence 2 transmission attempts will be performed (see
Table 5, “Retries,” on page 28). The number of retries performed, as well as the current
channel number associated, can be read in the Transmission Status Register (0x05).
The Last Error Status Register (0x07) informs about the trouble uncounted:
•
•
Failure cases:
–
Code viol (CV error bit)
–
Acknowledge error (ACKE error bit)
–
CRC error (FCSE error bit)
It should be noticed that contention is considered as normal CSMA/CD protocol
and, therefore, is not taken into account in failure cases. So, an 'infinite' number of
attempts can be performed if bus contention occurs continuously.
There is only one retry counter for all channels. When the user writes the Max_Retries
value, all channels start their transmission with this parameter.
Rearbitrate
The purpose of rearbitrate feature is to postpone a channel already in transmission in
order to authorize an higher priority (see Section "Priority Among the Different Channels", page 47) message to be transmit.
Typical Example
•
Max_retries = 1 (2 transmissions attempts).
•
If Ch8 is in a the retry loop and the user wants to transmit the Ch5 without waiting
the end of the loop, the user can use the rearbitrate command.
•
The TSS463AA will then wait until the end of the current transmission, reload the
retries counter and enable the Ch5 to transmit.
•
At the end of this transmission Ch5, either when the attempt is successful or the
exceeded retry count is reached, the retries counter is reloaded and the
transmission is activated for the Ch8 again.
48
TSS463-AA
4205B–AUTO–12/04
4205B–AUTO–12/04
EOF+IFS
Second attempt
Xmit Ch8
(Retries - 1)
EOF+IFS
Set CHER & CHTx /Ch8,
and set ITTE
Ex: set FSCE status bit
(not seen by application)
First attempt
Xmit Ch8
Delay
Second attempt
Xmit Ch8
* (not seen by application means no IT generation)
Ex: FCS Error
(Load Max-retries)
Set CHTx/Ch5 & ITROK
Xmit Ch5
First attempt
Xmit Ch8
* (not seen by application means no IT generation)
(Retries - 1)
Delay
Viol
Idle command
(Load Max-retries)
* (not seen by application)
Ex: FCS Error
Rearbitrate
(Activate Ch5)
(Load Max-retries)
Viol
First attempt
Xmit Ch8
Xmit Ch5
First attempt
Xmit Ch8
Set CHER & CHTx /Ch8,
and set ITTE
Ex: set FSCE status bit
Ex: FCS Error
(not seen by application)
(Load Max-retries)
Set CHTx/Ch5 & ITROK
(Load Max-retries)
* (not seen by application)
Ex: FCS Error
(Activate Ch5)
Rearbitrate
(Load Max-retries)
TSS463-AA
Figure 31. Rearbritrate Example
Delay
Delay
Viol
Viol
Delay
Viol
stand-by
EOF+IFS: 8 + 4 Timeslots
Delay Viol: 12 Timeslots
Figure 32. Idle and Rearbitrate Example
Idle
Delay
Viol
EOF+IFS: 8 + 4 Timeslots
Delay Viol: 12 Timeslots
If the user sets the idle bit anywhere (after rearbitrate), the idle mode is entered only at the end of all the transmit attempts
(for more information about idle command, see “Activate, Idle and Sleep Modes” on page 52.).
49
(Load Max-retries)
Ex: FCS Error
(not seen by application)
Disable Ch8(1)
(Activate Ch5)
Rearbitrate
(Load Max-retries)
Figure 33. Disable Channel After Rearbitrate
Ex: ACK Error
(not seen by application)
Set CHER & CHTx /Ch5,
and set ITTE
Ex: setACKE status bit
Delay
Viol
Delay
Viol
stand-by
(Retries - 1)
KO
Delay
Viol
Second attempt Xmit Ch5
First attempt
Xmit Ch5
First attempt
Xmit Ch8
Set CHTx/Ch5 & ITTOK
OK
EOF+IFS
stand-by
EOF+IFS: 8 + 4 Timeslots
Delay Viol: 12 Timeslots
(1) The disable is applied setting the CHTx/Ch8 bit to 1.
In this case, the TSS463AA completes the current attempt (Ch8) and let the transmission go on the new channel (Ch5 if
validated), otherwise it stops all attempts on the current channel.
Abort
An abort command is dedicated to channels already enabled in transmission or in inframe response. For example, this command can be used to break the retry procedure
on one channel.
Abort channel is done by setting the Error bit (CHER) in the Message Length and Status
Register (base_address + 0x02). This command is taken into account if the channel
aborted is not transmitted. When this abort command is really done, the TSS463AA set
to 1 the Transmitted bit (CHTx) of the Message Length and Status Register.
The abort mechanism is integrated into the transmit function. This mainly means, abort,
priority and retries live together in the transmit function.
50
TSS463-AA
4205B–AUTO–12/04
4205B–AUTO–12/04
Xmit Ch6
if Previously Failed
Xmit Ch6
if Previously Failed
Xmit Ch6
Xmit Ch4
/Ch6 & IT ROK
SetorCHTx
CHER
or IT RE
Set CHTx/Ch13
Set CHTx/Ch6 & ITROK
if Successful
Set CHTx/Ch6 & ITROK
if Successful
Set CHTx/Ch4 &ITROK
Abort Ch4 (during Xmit)
Abort Ch13 (before Xmit)
Activate
Abort Ch0 (before Xmit)
Set CHTx/Ch0
Ch s Initialization
Reset
TSS463-AA
Figure 34. Abort Example
12 Timeslots
51
Activate, Idle and
Sleep Modes
Sleep, idle and activate commands are located in the Command Register (0x03). These
three commands are general commands for the TSS463AA.
Idle and Activate
Commands
After reset, the TSS463AA starts in idle mode. In this mode, the oscillator operates
(CKOUT pin active) but the circuit cannot transmit or receive anything on the VAN bus.
The TxD output (pin 12) is in tri-state mode, a pull-up resistor must be provided externally or by the line driver to avoid floating state on the VAN bus. To activate the
TSS463AA, the user must set the activate bit (ACTI) and reset the idle bit (IDLE).
Figure 35. Idle and Activate Timings
Idle Mode
Activate Mode
SOF
RxD
Activate command
After Reset
SOF
TxD
8 TS
12 TS
3 TS
(max)
TS: Timeslot Period
Idle Mode
ACK
FCS
EOD
Activate Mode
RxD
Idle Command
INT
4 TS
5 TS
In both cases, the idle state can be verified reading the Line Status register (0x04).
Sleep Command
If the user sets the sleep bit (SLEEP), the TSS463AA enters in sleep mode, regardless
of the values of activate and idle bits. It means that, all non-user registers are set-up to
reduce the power consumption and the internal oscillator is immediately stopped. Then,
accesses to all registers (and to the messages) via the SPI/SCI interface are impossible
and CKOUT is not provided.
To exit from this mode the user must apply either an hardware reset (external reset pin)
either an asynchronous software reset (via the SPI/SCI interface).
In a typical application (see Figure 5), using the CKOUT feature (pin 8), if the
TSS463AA is put in sleep mode, the clock provided to the microcontroller is stopped.
So, the system does not run and the only way to awake this application is an external
reset.
52
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Linked Channels
The linkage feature allows two channels to share the same Message area, the message
pointer and the message length assumes this property:
•
Zero value as message length (M_L [4:0] - base_address + 0x03) declares the
channel linked to another channel.
•
The number of this other channel is defined in the message pointer field (M_P [6:0]
- base_address + 0x02).
•
The pointer and the length values for the Message area are defined only once, in
the register set of this other Channel.
Only one level of linkage can be created. This means, (see Figure 36) a Channel k can
be linked to the Channel i but not to Channel j, already defined as linked to Channel i.
All the others can be different between the two channels, for example the ID_Tag.
Figure 36. Linkage Mechanism
The Channel j linked
Channel i and j
....
share the same
Message area
to the Channel i
ID_Mask j (msb)
0x00
DRAK
ID_Tag j (lsb)
--- Message for Channels i & j ---
DATA n
CHER CHTx CHRx
i
EXT RAK RNW RTR
ID_Tag j (msb)
Length = n+2
--- Channel j ---
ID_Mask j (lsb)
--- Channel i ---
ID_Mask i (lsb)
ID_Mask i (msb)
Mess_Len = n+2
CHER CHTx CHRx
Mess_Ptr
DRAK
ID_Tag i (lsb)
EXT RAK RNW RTR
DATA 0
Message Status
ID_Tag i (msb)
This Message area sharing permits either to optimize the allocation of the 128 bytes of DATA, or to perform some special
communications between the different nodes of the network.
53
4205B–AUTO–12/04
Electrical Characteristics
Absolute Maximum Ratings
*NOTICE:
Ambient temperature under bias:
Automotive........................................................-40°C to 125°C
Storage Temperature ........................................-65°C to 150°C
Voltage on VCC to VSS .......................................... -0.5 to +7.0V
Voltage on any pin to VSS ..........................-0.5V to VCC +0.5V
Stresses at or above those listed under Absolute
Maximum Ratings may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions exceeding those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions may affect device reliability.
DC Characteristics
Table 10. TA = -40°C to 125°C; VCC = 5V + 10%; VSS = 0V
Symbol
Parameter
Min.
Max
Unit
Test Conditions
VIL
Input Low Voltage
-0.5
0.3·VCC·min
V
VIH
Input High Voltage
0.7·VCC max
VCC+0.5
V
VHY
Hyteresis voltage of
trigger CMOS inputs
0.4
-
V
see Table
VOL
Output Low Voltage
0.4
V
IOL = 3.2 mA, Vcc min
VOH
Output High Voltage
V
IOH = -3.2 mA, Vcc min
5
µA
0 < VIN < VCC
5
µA
0 < VIN < VCC
kΩ
Note 4
10
pF
Not tested
50
µA
(Note 1)
9
mA
(Notes 2, 3)
2.4
Input Leakage Current
IL
(SCLK, MOSI, SS)
Output Tristate
Leakage Current
IOZ
(MISO)
RPU, RPD
Input pull-up and pulldown resistors
CIO
I/O Buffer Capacitance
ICCSB
ICCOP
Notes:
54
1.
2.
3.
4.
Power Supply Current
Sleep mode
Power Supply Current
Idle or Active mode
70
Sleep Mode ICCSB is measured according to a VSS Clock Signal.
Active mode ICCOP is measured at: XTAL = 8 MHz clock, VAN speed rate = 125 KTS/s.
ICC is a function of the Clock Frequency. Figure 38 displays a graph showing ICC versus Clock frequency.
RESET, RxD0, RxD1, RxD2 inputs.
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Figure 37. ICC
Figure 38. ICCOP versus Clock Frequency at 125 KTimeslot/s
mA
9
8.5
8
7.5
MHz
2
4
6
8
55
4205B–AUTO–12/04
TA = -40°C to 125°C; VCC = 5V + 10%; VSS = 0V
AC Characteristics
Table 11. Microprocessor Interface
CLOAD = 200pF on SPI/SCI Lines
Symbol
fOP
Characteristic
Min
Max
Unit
Operating Frequency SPI
dc
4
MHz
SCI
dc
125
kHZ
250
-
ns
SCI
8
-
ms
tLEAD
Enable Lead Time
4
-
XTAL Period
tLAG
Enable Lead Time
12
-
XTAL Period
tW(SCKH)
Clock (SCLK) High Time
100
-
ns
tW(SCKL)
Clock (SCLK) Low Time
100
-
ns
tSU
Data Setup Time (Inputs)
40
-
ns
tH
Data Hold Time (Inputs)
40
-
ns
0
100
ns
Slave Disable Time (Hold Time to HighImpedance State)
-
200
ns
tV
Data Valid (after Enable Edge)
-
60
ns
tHO
Data Hold Time (Outputs after Enable Edge)
0
-
ns
INT Float Pulse Width
20
tCYC
High-Impedance State)
tDIS
Note:
SPI
Slave Access Time (Time to Data Active from
tA
tIZIL
Cycle Time
(1)
ns
1. Simulated Data
SS
(INPUT)
t CYC
t LEAD
SCLK
(INPUT)
t
FLAG
t W(SCKL)
t W(SCKH)
t DIS
A
MISO
(OUTPUT)
tH
t SU
tV
tHO
MOSI
(INPUT)
t
INT
56
IZIL
t
IZIL
float pulse only when address is 0x08 to 0x0B
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Interface
Oscillator Characteristics
Figure 39. C2 versus Frequency
pF
200
100
33
1
Note:
External Clock Drive
Characteristics (XTAL1)
2
4
8
MHz
C1 (no capacitance needed) see Figure 5.
Symbol
Parameter
Min
Max
tCHCH
Oscillator period
120
ns
tCHCX
High Time
20
ns
tCLCX
Low Time
20
ns
tCLCH
Rise Time
20
ns
tCHCL
Fall Time
20
ns
t CHCL
XTAL1
V IH
Unit
t CLCH
V IH
V IH
V IL
V IL
t CHCX
t CLCX
t CHCH
57
4205B–AUTO–12/04
Packaging Information
SO16
SO
58
MM
Inch
A
2.35
2.65
0.093
0.104
A1
0.10
0.30
0.004
0.012
B
0.35
0.49
0.014
0.019
C
0.23
0.32
0.009
0.013
D
10.10
10.50
0.398
0.413
E
7.40
7.60
0.291
0.299
e
1.27
BSC
0.050
BSC
H
10.00
10.65
0.394
0.419
h
0.25
0.75
0.010
0.029
L
0.40
1.27
0.016
0.050
N
16
16
a
0° 8°
0° 8°
TSS463-AA
4205B–AUTO–12/04
TSS463-AA
Ordering Information
Part Number
Supply Voltage
Temperature
Range
Package
Packing
TSS463-AA
5V +10%
-40°C to +125°C
SO16
Stick
TSS463-AA: R
5V +10%
-40°C to +125°C
SO16
Tape and Reel
TSS463A-TERZ(1)
5V +10%
-40°C - +125°C
SO16
Tape and Reel
Note:
1. These products are available in ROHS version.
59
4205B–AUTO–12/04
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Regional Headquarters
Europe
Atmel Sarl
Route des Arsenaux 41
Case Postale 80
CH-1705 Fribourg
Switzerland
Tel: (41) 26-426-5555
Fax: (41) 26-426-5500
Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Atmel Operations
Memory
2325 Orchard Parkway
San Jose, CA 95131
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
RF/Automotive
Theresienstrasse 2
Postfach 3535
74025 Heilbronn, Germany
Tel: (49) 71-31-67-0
Fax: (49) 71-31-67-2340
Microcontrollers
2325 Orchard Parkway
San Jose, CA 95131
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
La Chantrerie
BP 70602
44306 Nantes Cedex 3, France
Tel: (33) 2-40-18-18-18
Fax: (33) 2-40-18-19-60
ASIC/ASSP/Smart Cards
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Biometrics/Imaging/Hi-Rel MPU/
High Speed Converters/RF Datacom
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex, France
Tel: (33) 4-76-58-30-00
Fax: (33) 4-76-58-34-80
Zone Industrielle
13106 Rousset Cedex, France
Tel: (33) 4-42-53-60-00
Fax: (33) 4-42-53-60-01
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Scottish Enterprise Technology Park
Maxwell Building
East Kilbride G75 0QR, Scotland
Tel: (44) 1355-803-000
Fax: (44) 1355-242-743
e-mail
[email protected]
Web Site
http://www.atmel.com
Disclaimer: Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard
warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any
errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and
does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are
granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use
as critical components in life support devices or systems.
© Atmel Corporation 2004. All rights reserved. Atmel®, logo and combinations thereof are registered trademarks, and Everywhere You Are(SM)
are the trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
Printed on recycled paper.
4205B–AUTO–12/04
/xM