ATMEL ATA6140

Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Temperature and Voltage Compensated Frequency (Fully Integrated Oscillator)
Warning Indication of Lamp Failure by Means of Frequency Doubling
Voltage Dependence of the Indicator Lamps also Compensated for Lamp Failure
Relay Output with High Current Capability and Low Saturation Voltage
Frequency Doubling only During Direction Mode
Temperature Compensated Threshold for Lamp Failure Detection
Overvoltage and Undervoltage Shut Down of the Relay Outputs
Quiescent Current I ≤ 10 µA (Switches Open)
EMI Protection According to ISO TR 7637/1, Test Level 4 (Exclusive Load Dump)
Reversed Battery Protection by Means of a Serial Resistor and Relay Coil Connected
Load Dump Protection 80 V with External Protection Components
12 V/24 V Application
Package: SO16
Electrostatic sensitive device.
Observe precautions for handling.
Two-relay
Flasher
ATA6140
Description
The integrated circuit ATA6140 is used in relay-controlled automotive flashers. With
two output stages, each side of the vehicle is controlled separately. A left and a right
direction indicator input with only a small control current makes switch contacts for
small loads possible. The separate hazard warning input simplifies the construction of
the hazard switch. Lamp outage is indicated by frequency doubling during direction
mode. Thanks to the extreme low current consumption the ATA6140 can be connected
to the battery directly.
Figure 1. Block Diagram
Integrated
oscillator
24V
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
Debounce
Measure input
Battery sense
Batt
POR
Haz
Input
Debounce
TS1G
Input
Debounce
TS1B
Input
Debounce
TS2G
Input
Debounce
TS2B
Input
Charge
pump
Ign
Output
stages
Logic
Output right
Over-, undervoltage
and load dump
detection
Debounce
Output left
IC-Ground
Comp
Test pin
LED
LED
Rev. 4560C–AUTO–10/03
Pin Configuration
Figure 2. Pinning SO16
TS1G
TS1B
TS2G
TS2B
Output right
Batt
Output left
Ign
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
IC-Ground
Test pin
Battery sense
24V
Measure input
Haz
LED
LED
Pin Description
2
Pin
Symbol
1
TS1G
Input left ground
Function
2
TS1B
Input left battery
3
TS2G
Input right ground
4
TS2B
Input right battery
5
Output right
Output right
6
Batt
Battery force
7
Output left
Output left
8
Ign
Ignition
9
LED
LED outage left
10
LED
LED outage right
11
Haz
Input hazard
12
Measure input
13
24V
14
Battery sense
15
Test pin
16
IC-Ground
Measure input
24 V version
Battery sense
Test pin
IC ground
ATA6140
4560C–AUTO–10/03
ATA6140
Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Parameters
Symbol
Value
Unit
Supply voltage, pin 6
VVS
6 to 40
V
Ambient temperature range
Tamb
-40 to +105
°C
Junction temperature range
Tj
-40 to +150
°C
Storage temperature range
Tstg
-55 to +150
°C
Symbol
Value
Unit
RthJA
110
K/W
Symbol
Value
Unit
Supply voltage, pin 6
VVS
6 to 24
V
Supply voltage, pin 6
(24 V version, pin 13 to GND)
VVS
18 to 33
V
Thermal Resistance
Parameters
Maximum thermal resistance SO16
Operating Range
Parameters
Noise and Surge Immunity
Parameters
Conducted interferences
(1)
ESD (Human Body Model)
ESD FCDM (Field induced Charge Device Model)
Note:
Test Conditions
Value
ISO 7637-1
Level 4
MIL-STD-883D Method 3015.7(2)
2 kV
MIL-STD-883D Method 3015.7 (pin 12 and pin 14)
1 kV
ESD - S. 5.3
500 V
1. At both outputs a relay of minimum 130 W should be added (for details see application circuits Figure 4 on page 7 to
Figure 11 on page 11).
2. Exclusive pin 12 and pin 14.
3
4560C–AUTO–10/03
Electrical Characteristics
No.
1
Parameters
Test Conditions
Pin
Symbol
Min.
Typ.
Max.
Unit
Type*
Supply Voltage Range
1.1
Supply voltage
6
VVS
8
16
V
C
1.1
Supply voltage
(24 V version)
6
VVS
18
33
V
C
2
Current Consumption
2.1
Quiescent current
(VS)
VVS < 16 V
switches open
6
IVS
10
µA
A
2.1
Quiescent current
(VS, 24 V version)
VVS < 33 V
switches open
6
IVS
20
µA
A
2.2
Supply current (VS)
VVS < 16 V
6
IVS
6
mA
A
2.2
Supply current
(VS, 24 V version)
VVS < 33 V
6
IVS
8
mA
A
6
VVU
6
8
V
A
tdUV
2.5
10
ms
A
6
VVO
18
22
V
A
6
VVO
V
A
3
Under and Overvoltage Detection
3.1
Undervoltage
detection threshold
3.2
Undervoltage
detection delay time
3.3
Overvoltage detection
threshold
3.3
Overvoltage detection
threshold
(24 V version)
4
Disabled in
24 V version
(pin 13 to GND)
Relay Outputs
4.1
Current output right
5
II5
170
mA
A
4.2
Current output left
7
II7
170
mA
A
4.3
Saturation voltage
right
170 mA at 23°C
5
VSATR
1
V
A
4.4
Saturation voltage left
170 mA at 23°C
7
VSATL
1
V
A
4.5
Leakage current right
5
ILEAKR
3
µA
A
4.5
Leakage current right
(24 V version)
5
ILEAKR
6
µA
A
4.6
Leakage current left
7
ILEAKL
3
µA
A
4.6
Leakage current left
(24 V version)
7
ILEAKL
6
µA
A
4.7
Start delay time right
5
TDR
10
40
ms
A
4.8
Start delay time left
7
TDL
10
40
ms
A
5
Control Signal Thresholds
5.1
Frequency doubling
VS = 9 V
12
VTHFD9
42
45
48
mV
A
5.2
Frequency doubling
VS = 15 V
12
VTHFD15
50
53
57
mV
A
5.2
Frequency doubling
(24 V version)
VS = 24 V
12
VTHFD24
mV
A
5.3
Short circuit detection
VS = 13.5 V
12
VTHSC
mV
B
65
425
475
525
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter
4
ATA6140
4560C–AUTO–10/03
ATA6140
Electrical Characteristics (Continued)
No.
Parameters
Test Conditions
Pin
Symbol
5.3
Short circuit detection
(24 V version)
VS = 24 V
12
VTHSC
5.4
Temperature
coefficient
-40°C to +105°C
12
CTH
5.5
Input current
VS = 13.5 V
12
ITH
5.5
Input current
(24 V version)
VS = 24 V
12
ITH
6
Min.
Typ.
Max.
Unit
Type*
650
mV
B
30
µV/K
C
2
µA
A
4
µA
A
1
4.5
V
A
LED Inputs
6.1
Threshold left
VS = 13.5 V
9
VLEDL
6.2
Threshold right
VS = 13.5 V
10
VLEDR
1
4.5
V
A
6.3
Pull-up resistor left
9
RLEDL
10
75
kW
A
6.4
Pull-up resistor right
10
RLEDR
10
75
kW
A
FB
-10.5
+12
7
Timing
7.1
Basic frequency
%
A
7.2
Bright period
50
%
A
7.3
Bright period in failure
mode
40
%
A
7.4
Failure frequency
1/f = 706 ms
FF
2.2 ´
FB
A
*) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter
Short Circuit or
Overload Detection
Delay
Direction mode:
100 ms during the first bright phase, 50 ms during all following bright phases
Hazard mode: 100 ms during all bright phases
In case of overload the relay output switches off (not stored)
Bulb Outage
Detection
The detection of bulb outage takes place during the bright phase. There is a delay time
of typically 128 ms before ATA6140 measures the bulb current with a debounce period
of 5 ms. After this time the inrush current dropped significantly.
Application hint:
It has to be considered that a slow relay contact may shorten the inrush current decay
time and too high current would be measured and falsely an outage may not be
detected. If operated with low supply voltage (e.g., 8 V) the relay speed could be even
slower.
5
4560C–AUTO–10/03
Flasher Operating Mode
Ignition
Input Left
Ground
Input Right
Ground
Input Left
Ignition
Input Right
Ignition
Input
Hazard
Left
Lamps(1)
Right
Lamps(1)
Frequency
in Case of
Lamp
Failure(1)
Off
Open
Open
IC-Ground
IC-Ground
Open
x
x
x
Off
Ground
Open
IC-Ground
IC-Ground
Open
x
x
x
Off
Open
Ground
IC-Ground
IC-Ground
Open
x
x
x
Off
Open
Open
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
Off
Ground
Open
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
Off
Open
Ground
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
Off
Ground
Ground
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
Off
Ground
Ground
IC-Ground
IC-Ground
Open
x
x
x(2)
On
Open
Open
IC-Ground
IC-Ground
Open
x
x
x
On
Ground
Open
IC-Ground
IC-Ground
Open
Flash
x
Double
On
Open
Ground
IC-Ground
IC-Ground
Open
x
Flash
Double
On
Open
Open
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
On
Ground
Open
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
On
Open
Ground
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
On
Ground
Ground
IC-Ground
IC-Ground
Ground
Flash
Flash
Normal
On
Ground
Ground
IC-Ground
IC-Ground
Open
Flash
Flash
Normal
Off
VBATT
VBATT
Open
Open
Open
x
x
x
Off
VBATT
VBATT
Ignition
Open
Open
x
x
x
Off
VBATT
VBATT
Open
Ignition
Open
x
x
x
Off
VBATT
VBATT
Open
Open
Ground
Flash
Flash
Normal
Off
VBATT
VBATT
Ignition
Open
Ground
Flash
Flash
Normal
Off
VBATT
VBATT
Open
Ignition
Ground
Flash
Flash
Normal
Off
VBATT
VBATT
Ignition
Ignition
Ground
Flash
Flash
Normal
Off
VBATT
VBATT
Ignition
Ignition
Open
x
x
x(3)
On
VBATT
VBATT
Open
Open
Open
x
x
x
On
VBATT
VBATT
Ignition
Open
Open
Flash
x
Double
On
VBATT
VBATT
Open
Ignition
Open
x
Flash
Double
On
VBATT
VBATT
Open
Open
Ground
Flash
Flash
Normal
On
VBATT
VBATT
Ignition
Open
Ground
Flash
Flash
Normal
On
VBATT
VBATT
Open
Ignition
Ground
Flash
Flash
Normal
On
VBATT
VBATT
Ignition
Ignition
Ground
Flash
Flash
Normal
On
VBATT
VBATT
Ignition
Ignition
Open
Flash
Flash
Nnormal
Notes:
6
1. x = no flashing
2. If ignition is OFF, the input level cannot be sensed (the IC is in the sleep mode). For hazard mode use the input hazard.
3. For hazard mode use input hazard or switch to battery as shown in Figure 6 on page 8 and Figure 10 on page 10.
ATA6140
4560C–AUTO–10/03
ATA6140
Diagrams
Figure 3. Timing Diagram
Basic frequency
Bright phase 50%
Dark phase 50%
t/ms
706
353
100 128.5
127.5
50 ms - 353 ms => short circuit detection
100 ms - 353 ms => short circuit detection during first bright phase (turn signal mode)
100 ms - 353 ms => short circuit detection during each bright phase (hazard signal mode)
127.5 ms - 128.5 ms => lamp outage detection
0
50
Doubled frequency
60%
40%
50
0
100 128.5
127.5
t/ms
321
Figure 4. Application 1: 12 V Version, Turn Signal Switches to GND, Hazard Switch to GND
Ign
Batt
10uF/63V
IC Ground
3x
1.3k
Batt
Battery sense
Integrated
oscillator
24V,
nc
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
TS1G
TS2G
10k
36k
36k
Input
Measure input
Debounce
POR
Haz
18mOhm
Charge
pump
1.5k
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Output
stages
Ign
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
Test pin, nc IC-Ground
LED
LED
560Ohm/0.5W
7
4560C–AUTO–10/03
Figure 5. Application 2: 12 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND
Ign
Batt
10uF/63V
IC Ground
Battery sense
Batt
18mOhm
Integrated
oscillator
1.3k
24V,
nc
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
Debounce
POR
10k
Haz
10k
TS1B
10k
TS2B
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Measure input
Charge
pump
Ign to
IC-Ground
Output
stages
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
2x
1.3k
Test pin, nc
LED
IC-Ground
LED
560Ohm/0.5W
Figure 6. Application 3: 12 V Version, Turn Signal Switches to Ignition, Hazard Switch to Battery
Batt
Ign
10uF/63V
IC Ground
Haz
Batt
Battery sense
Integrated
oscillator
24V
nc
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
10k
TS1B
10k
TS2B
1.3k
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Measure input
Debounce
POR
Input
18mOhm
Charge
pump
Output
stages
Ign to
IC-Ground
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
1.3k
Test pin, nc
IC-Ground
LED
LED
560Ohm/0.5W
8
ATA6140
4560C–AUTO–10/03
ATA6140
Figure 7. Application 4: 12 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND, additional LED Outage
Ign
Batt
10uF/63V
IC Ground
Batt
Battery sense
Integrated
oscillator
1.3k
24V,
nc
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
10k
10k
TS1B
10k
TS2B
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Measure input
Debounce
POR
Haz
18mOhm
Charge
pump
Ign to
IC-Ground
Output
stages
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
2x
1.3k
IC-Ground
Test pin, nc
18k
560Ohm/0.5W
right
LED outage
18k
left
Figure 8. Application 1: 24 V Version, Turn Signal Switches to GND, Hazard Switch to GND
Ign
Batt
10uF/63V
Batt
3x
2.7k
Battery sense
Integrated
oscillator
24V
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
TS1G
TS2G
20k
36k
36k
Measure input
Debounce
POR
Haz
TBD
Charge
pump
5.1k
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Output
stages
Ign
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
Test pin, nc
IC-Ground
LED
LED
560Ohm/0.5W
9
4560C–AUTO–10/03
Figure 9. Application 2: 24 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND
Ign
Batt
10uF/63V
Battery sense
Batt
TBD
Integrated
oscillator
2.7k
24V
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
Debounce
POR
Haz
TS1B
TS2B
20k
20k
20k
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
2x
2.7k
Measure input
Charge
pump
Ign to
IC-Ground
Output
stages
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
LED
IC-Ground
Test pin, nc
LED
560Ohm/0.5W
Figure 10. Application 3: 24 V Version, Turn Signal Switches to Ignition, Hazard Switch to Battery
Batt
Ign
10uF/63V
Battery sense
Batt
Integrated
oscillator
Haz
24V
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
TS1B
TS2B
20k
20k
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Measure input
Debounce
POR
Input
TBD
Charge
pump
Output
stages
Ign to
IC-Ground
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
2x
2.7k
Test pin, nc
IC-Ground
LED
LED
560Ohm/0.5W
10
ATA6140
4560C–AUTO–10/03
ATA6140
Figure 11. Application 4: 24 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND, additional LED Outage
Ign
Batt
10uF/63V
Batt
Integrated
oscillator
2.7k
24V
Current monitoring
and short circuit
protection
Comp
Power on and
5 V regulator
Bias
current
TS1B
TS2B
20k
20k
20k
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
Input
Debounce
TBD
Measure input
Debounce
POR
Haz
Battery sense
Charge
pump
Ign to
IC-Ground
Output
stages
Output right
Output left
Logic
Over-, undervoltage
and load dump
detection
Comp
2x
2.7k
Test pin, nc
IC-Ground
560Ohm/0.5W
18k
18k
right
LED outage
left
11
4560C–AUTO–10/03
Ordering Information
Extended Type Number
Package
ATA6140-TBQ
Remarks
SO16
Taped and reeled
Package Information
Package SO16
Dimensions in mm
5.2
4.8
10.0
9.85
3.7
1.4
0.25
0.10
0.4
1.27
6.15
5.85
8.89
16
0.2
3.8
9
technical drawings
according to DIN
specifications
1
12
8
ATA6140
4560C–AUTO–10/03
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Regional Headquarters
Europe
Atmel Sarl
Route des Arsenaux 41
Case Postale 80
CH-1705 Fribourg
Switzerland
Tel: (41) 26-426-5555
Fax: (41) 26-426-5500
Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Atmel Operations
Memory
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
RF/Automotive
Theresienstrasse 2
Postfach 3535
74025 Heilbronn, Germany
Tel: (49) 71-31-67-0
Fax: (49) 71-31-67-2340
Microcontrollers
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
La Chantrerie
BP 70602
44306 Nantes Cedex 3, France
Tel: (33) 2-40-18-18-18
Fax: (33) 2-40-18-19-60
ASIC/ASSP/Smart Cards
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Biometrics/Imaging/Hi-Rel MPU/
High Speed Converters/RF Datacom
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex, France
Tel: (33) 4-76-58-30-00
Fax: (33) 4-76-58-34-80
Zone Industrielle
13106 Rousset Cedex, France
Tel: (33) 4-42-53-60-00
Fax: (33) 4-42-53-60-01
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Scottish Enterprise Technology Park
Maxwell Building
East Kilbride G75 0QR, Scotland
Tel: (44) 1355-803-000
Fax: (44) 1355-242-743
Literature Requests
www.atmel.com/literature
Disclaimer: Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard
warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any
errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and
does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are
granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use
as critical components in life support devices or systems.
© Atmel Corporation 2003. All rights reserved.
Atmel ® and combinations thereof are the registered trademarks of Atmel Corporation or its subsidiaries.
Other terms and product names may be the trademarks of others.
Printed on recycled paper.
4560C–AUTO–10/03