Features • • • • • • • • • • • • • Temperature and Voltage Compensated Frequency (Fully Integrated Oscillator) Warning Indication of Lamp Failure by Means of Frequency Doubling Voltage Dependence of the Indicator Lamps also Compensated for Lamp Failure Relay Output with High Current Capability and Low Saturation Voltage Frequency Doubling only During Direction Mode Temperature Compensated Threshold for Lamp Failure Detection Overvoltage and Undervoltage Shut Down of the Relay Outputs Quiescent Current I ≤ 10 µA (Switches Open) EMI Protection According to ISO TR 7637/1, Test Level 4 (Exclusive Load Dump) Reversed Battery Protection by Means of a Serial Resistor and Relay Coil Connected Load Dump Protection 80 V with External Protection Components 12 V/24 V Application Package: SO16 Electrostatic sensitive device. Observe precautions for handling. Two-relay Flasher ATA6140 Description The integrated circuit ATA6140 is used in relay-controlled automotive flashers. With two output stages, each side of the vehicle is controlled separately. A left and a right direction indicator input with only a small control current makes switch contacts for small loads possible. The separate hazard warning input simplifies the construction of the hazard switch. Lamp outage is indicated by frequency doubling during direction mode. Thanks to the extreme low current consumption the ATA6140 can be connected to the battery directly. Figure 1. Block Diagram Integrated oscillator 24V Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current Debounce Measure input Battery sense Batt POR Haz Input Debounce TS1G Input Debounce TS1B Input Debounce TS2G Input Debounce TS2B Input Charge pump Ign Output stages Logic Output right Over-, undervoltage and load dump detection Debounce Output left IC-Ground Comp Test pin LED LED Rev. 4560C–AUTO–10/03 Pin Configuration Figure 2. Pinning SO16 TS1G TS1B TS2G TS2B Output right Batt Output left Ign 1 2 3 4 5 6 7 8 16 15 14 13 12 11 10 9 IC-Ground Test pin Battery sense 24V Measure input Haz LED LED Pin Description 2 Pin Symbol 1 TS1G Input left ground Function 2 TS1B Input left battery 3 TS2G Input right ground 4 TS2B Input right battery 5 Output right Output right 6 Batt Battery force 7 Output left Output left 8 Ign Ignition 9 LED LED outage left 10 LED LED outage right 11 Haz Input hazard 12 Measure input 13 24V 14 Battery sense 15 Test pin 16 IC-Ground Measure input 24 V version Battery sense Test pin IC ground ATA6140 4560C–AUTO–10/03 ATA6140 Absolute Maximum Ratings Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Parameters Symbol Value Unit Supply voltage, pin 6 VVS 6 to 40 V Ambient temperature range Tamb -40 to +105 °C Junction temperature range Tj -40 to +150 °C Storage temperature range Tstg -55 to +150 °C Symbol Value Unit RthJA 110 K/W Symbol Value Unit Supply voltage, pin 6 VVS 6 to 24 V Supply voltage, pin 6 (24 V version, pin 13 to GND) VVS 18 to 33 V Thermal Resistance Parameters Maximum thermal resistance SO16 Operating Range Parameters Noise and Surge Immunity Parameters Conducted interferences (1) ESD (Human Body Model) ESD FCDM (Field induced Charge Device Model) Note: Test Conditions Value ISO 7637-1 Level 4 MIL-STD-883D Method 3015.7(2) 2 kV MIL-STD-883D Method 3015.7 (pin 12 and pin 14) 1 kV ESD - S. 5.3 500 V 1. At both outputs a relay of minimum 130 W should be added (for details see application circuits Figure 4 on page 7 to Figure 11 on page 11). 2. Exclusive pin 12 and pin 14. 3 4560C–AUTO–10/03 Electrical Characteristics No. 1 Parameters Test Conditions Pin Symbol Min. Typ. Max. Unit Type* Supply Voltage Range 1.1 Supply voltage 6 VVS 8 16 V C 1.1 Supply voltage (24 V version) 6 VVS 18 33 V C 2 Current Consumption 2.1 Quiescent current (VS) VVS < 16 V switches open 6 IVS 10 µA A 2.1 Quiescent current (VS, 24 V version) VVS < 33 V switches open 6 IVS 20 µA A 2.2 Supply current (VS) VVS < 16 V 6 IVS 6 mA A 2.2 Supply current (VS, 24 V version) VVS < 33 V 6 IVS 8 mA A 6 VVU 6 8 V A tdUV 2.5 10 ms A 6 VVO 18 22 V A 6 VVO V A 3 Under and Overvoltage Detection 3.1 Undervoltage detection threshold 3.2 Undervoltage detection delay time 3.3 Overvoltage detection threshold 3.3 Overvoltage detection threshold (24 V version) 4 Disabled in 24 V version (pin 13 to GND) Relay Outputs 4.1 Current output right 5 II5 170 mA A 4.2 Current output left 7 II7 170 mA A 4.3 Saturation voltage right 170 mA at 23°C 5 VSATR 1 V A 4.4 Saturation voltage left 170 mA at 23°C 7 VSATL 1 V A 4.5 Leakage current right 5 ILEAKR 3 µA A 4.5 Leakage current right (24 V version) 5 ILEAKR 6 µA A 4.6 Leakage current left 7 ILEAKL 3 µA A 4.6 Leakage current left (24 V version) 7 ILEAKL 6 µA A 4.7 Start delay time right 5 TDR 10 40 ms A 4.8 Start delay time left 7 TDL 10 40 ms A 5 Control Signal Thresholds 5.1 Frequency doubling VS = 9 V 12 VTHFD9 42 45 48 mV A 5.2 Frequency doubling VS = 15 V 12 VTHFD15 50 53 57 mV A 5.2 Frequency doubling (24 V version) VS = 24 V 12 VTHFD24 mV A 5.3 Short circuit detection VS = 13.5 V 12 VTHSC mV B 65 425 475 525 *) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter 4 ATA6140 4560C–AUTO–10/03 ATA6140 Electrical Characteristics (Continued) No. Parameters Test Conditions Pin Symbol 5.3 Short circuit detection (24 V version) VS = 24 V 12 VTHSC 5.4 Temperature coefficient -40°C to +105°C 12 CTH 5.5 Input current VS = 13.5 V 12 ITH 5.5 Input current (24 V version) VS = 24 V 12 ITH 6 Min. Typ. Max. Unit Type* 650 mV B 30 µV/K C 2 µA A 4 µA A 1 4.5 V A LED Inputs 6.1 Threshold left VS = 13.5 V 9 VLEDL 6.2 Threshold right VS = 13.5 V 10 VLEDR 1 4.5 V A 6.3 Pull-up resistor left 9 RLEDL 10 75 kW A 6.4 Pull-up resistor right 10 RLEDR 10 75 kW A FB -10.5 +12 7 Timing 7.1 Basic frequency % A 7.2 Bright period 50 % A 7.3 Bright period in failure mode 40 % A 7.4 Failure frequency 1/f = 706 ms FF 2.2 ´ FB A *) Type means: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter Short Circuit or Overload Detection Delay Direction mode: 100 ms during the first bright phase, 50 ms during all following bright phases Hazard mode: 100 ms during all bright phases In case of overload the relay output switches off (not stored) Bulb Outage Detection The detection of bulb outage takes place during the bright phase. There is a delay time of typically 128 ms before ATA6140 measures the bulb current with a debounce period of 5 ms. After this time the inrush current dropped significantly. Application hint: It has to be considered that a slow relay contact may shorten the inrush current decay time and too high current would be measured and falsely an outage may not be detected. If operated with low supply voltage (e.g., 8 V) the relay speed could be even slower. 5 4560C–AUTO–10/03 Flasher Operating Mode Ignition Input Left Ground Input Right Ground Input Left Ignition Input Right Ignition Input Hazard Left Lamps(1) Right Lamps(1) Frequency in Case of Lamp Failure(1) Off Open Open IC-Ground IC-Ground Open x x x Off Ground Open IC-Ground IC-Ground Open x x x Off Open Ground IC-Ground IC-Ground Open x x x Off Open Open IC-Ground IC-Ground Ground Flash Flash Normal Off Ground Open IC-Ground IC-Ground Ground Flash Flash Normal Off Open Ground IC-Ground IC-Ground Ground Flash Flash Normal Off Ground Ground IC-Ground IC-Ground Ground Flash Flash Normal Off Ground Ground IC-Ground IC-Ground Open x x x(2) On Open Open IC-Ground IC-Ground Open x x x On Ground Open IC-Ground IC-Ground Open Flash x Double On Open Ground IC-Ground IC-Ground Open x Flash Double On Open Open IC-Ground IC-Ground Ground Flash Flash Normal On Ground Open IC-Ground IC-Ground Ground Flash Flash Normal On Open Ground IC-Ground IC-Ground Ground Flash Flash Normal On Ground Ground IC-Ground IC-Ground Ground Flash Flash Normal On Ground Ground IC-Ground IC-Ground Open Flash Flash Normal Off VBATT VBATT Open Open Open x x x Off VBATT VBATT Ignition Open Open x x x Off VBATT VBATT Open Ignition Open x x x Off VBATT VBATT Open Open Ground Flash Flash Normal Off VBATT VBATT Ignition Open Ground Flash Flash Normal Off VBATT VBATT Open Ignition Ground Flash Flash Normal Off VBATT VBATT Ignition Ignition Ground Flash Flash Normal Off VBATT VBATT Ignition Ignition Open x x x(3) On VBATT VBATT Open Open Open x x x On VBATT VBATT Ignition Open Open Flash x Double On VBATT VBATT Open Ignition Open x Flash Double On VBATT VBATT Open Open Ground Flash Flash Normal On VBATT VBATT Ignition Open Ground Flash Flash Normal On VBATT VBATT Open Ignition Ground Flash Flash Normal On VBATT VBATT Ignition Ignition Ground Flash Flash Normal On VBATT VBATT Ignition Ignition Open Flash Flash Nnormal Notes: 6 1. x = no flashing 2. If ignition is OFF, the input level cannot be sensed (the IC is in the sleep mode). For hazard mode use the input hazard. 3. For hazard mode use input hazard or switch to battery as shown in Figure 6 on page 8 and Figure 10 on page 10. ATA6140 4560C–AUTO–10/03 ATA6140 Diagrams Figure 3. Timing Diagram Basic frequency Bright phase 50% Dark phase 50% t/ms 706 353 100 128.5 127.5 50 ms - 353 ms => short circuit detection 100 ms - 353 ms => short circuit detection during first bright phase (turn signal mode) 100 ms - 353 ms => short circuit detection during each bright phase (hazard signal mode) 127.5 ms - 128.5 ms => lamp outage detection 0 50 Doubled frequency 60% 40% 50 0 100 128.5 127.5 t/ms 321 Figure 4. Application 1: 12 V Version, Turn Signal Switches to GND, Hazard Switch to GND Ign Batt 10uF/63V IC Ground 3x 1.3k Batt Battery sense Integrated oscillator 24V, nc Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current TS1G TS2G 10k 36k 36k Input Measure input Debounce POR Haz 18mOhm Charge pump 1.5k Debounce Input Debounce Input Debounce Input Debounce Input Debounce Output stages Ign Output right Output left Logic Over-, undervoltage and load dump detection Comp Test pin, nc IC-Ground LED LED 560Ohm/0.5W 7 4560C–AUTO–10/03 Figure 5. Application 2: 12 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND Ign Batt 10uF/63V IC Ground Battery sense Batt 18mOhm Integrated oscillator 1.3k 24V, nc Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current Debounce POR 10k Haz 10k TS1B 10k TS2B Input Debounce Input Debounce Input Debounce Input Debounce Input Debounce Measure input Charge pump Ign to IC-Ground Output stages Output right Output left Logic Over-, undervoltage and load dump detection Comp 2x 1.3k Test pin, nc LED IC-Ground LED 560Ohm/0.5W Figure 6. Application 3: 12 V Version, Turn Signal Switches to Ignition, Hazard Switch to Battery Batt Ign 10uF/63V IC Ground Haz Batt Battery sense Integrated oscillator 24V nc Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current 10k TS1B 10k TS2B 1.3k Debounce Input Debounce Input Debounce Input Debounce Input Debounce Measure input Debounce POR Input 18mOhm Charge pump Output stages Ign to IC-Ground Output right Output left Logic Over-, undervoltage and load dump detection Comp 1.3k Test pin, nc IC-Ground LED LED 560Ohm/0.5W 8 ATA6140 4560C–AUTO–10/03 ATA6140 Figure 7. Application 4: 12 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND, additional LED Outage Ign Batt 10uF/63V IC Ground Batt Battery sense Integrated oscillator 1.3k 24V, nc Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current 10k 10k TS1B 10k TS2B Input Debounce Input Debounce Input Debounce Input Debounce Input Debounce Measure input Debounce POR Haz 18mOhm Charge pump Ign to IC-Ground Output stages Output right Output left Logic Over-, undervoltage and load dump detection Comp 2x 1.3k IC-Ground Test pin, nc 18k 560Ohm/0.5W right LED outage 18k left Figure 8. Application 1: 24 V Version, Turn Signal Switches to GND, Hazard Switch to GND Ign Batt 10uF/63V Batt 3x 2.7k Battery sense Integrated oscillator 24V Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current TS1G TS2G 20k 36k 36k Measure input Debounce POR Haz TBD Charge pump 5.1k Input Debounce Input Debounce Input Debounce Input Debounce Input Debounce Output stages Ign Output right Output left Logic Over-, undervoltage and load dump detection Comp Test pin, nc IC-Ground LED LED 560Ohm/0.5W 9 4560C–AUTO–10/03 Figure 9. Application 2: 24 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND Ign Batt 10uF/63V Battery sense Batt TBD Integrated oscillator 2.7k 24V Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current Debounce POR Haz TS1B TS2B 20k 20k 20k Input Debounce Input Debounce Input Debounce Input Debounce Input Debounce 2x 2.7k Measure input Charge pump Ign to IC-Ground Output stages Output right Output left Logic Over-, undervoltage and load dump detection Comp LED IC-Ground Test pin, nc LED 560Ohm/0.5W Figure 10. Application 3: 24 V Version, Turn Signal Switches to Ignition, Hazard Switch to Battery Batt Ign 10uF/63V Battery sense Batt Integrated oscillator Haz 24V Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current TS1B TS2B 20k 20k Debounce Input Debounce Input Debounce Input Debounce Input Debounce Measure input Debounce POR Input TBD Charge pump Output stages Ign to IC-Ground Output right Output left Logic Over-, undervoltage and load dump detection Comp 2x 2.7k Test pin, nc IC-Ground LED LED 560Ohm/0.5W 10 ATA6140 4560C–AUTO–10/03 ATA6140 Figure 11. Application 4: 24 V Version, Turn Signal Switches to Ignition, Hazard Switch to GND, additional LED Outage Ign Batt 10uF/63V Batt Integrated oscillator 2.7k 24V Current monitoring and short circuit protection Comp Power on and 5 V regulator Bias current TS1B TS2B 20k 20k 20k Input Debounce Input Debounce Input Debounce Input Debounce Input Debounce TBD Measure input Debounce POR Haz Battery sense Charge pump Ign to IC-Ground Output stages Output right Output left Logic Over-, undervoltage and load dump detection Comp 2x 2.7k Test pin, nc IC-Ground 560Ohm/0.5W 18k 18k right LED outage left 11 4560C–AUTO–10/03 Ordering Information Extended Type Number Package ATA6140-TBQ Remarks SO16 Taped and reeled Package Information Package SO16 Dimensions in mm 5.2 4.8 10.0 9.85 3.7 1.4 0.25 0.10 0.4 1.27 6.15 5.85 8.89 16 0.2 3.8 9 technical drawings according to DIN specifications 1 12 8 ATA6140 4560C–AUTO–10/03 Atmel Corporation 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 487-2600 Regional Headquarters Europe Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH-1705 Fribourg Switzerland Tel: (41) 26-426-5555 Fax: (41) 26-426-5500 Asia Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimshatsui East Kowloon Hong Kong Tel: (852) 2721-9778 Fax: (852) 2722-1369 Japan 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan Tel: (81) 3-3523-3551 Fax: (81) 3-3523-7581 Atmel Operations Memory 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 RF/Automotive Theresienstrasse 2 Postfach 3535 74025 Heilbronn, Germany Tel: (49) 71-31-67-0 Fax: (49) 71-31-67-2340 Microcontrollers 2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 La Chantrerie BP 70602 44306 Nantes Cedex 3, France Tel: (33) 2-40-18-18-18 Fax: (33) 2-40-18-19-60 ASIC/ASSP/Smart Cards 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Biometrics/Imaging/Hi-Rel MPU/ High Speed Converters/RF Datacom Avenue de Rochepleine BP 123 38521 Saint-Egreve Cedex, France Tel: (33) 4-76-58-30-00 Fax: (33) 4-76-58-34-80 Zone Industrielle 13106 Rousset Cedex, France Tel: (33) 4-42-53-60-00 Fax: (33) 4-42-53-60-01 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Scottish Enterprise Technology Park Maxwell Building East Kilbride G75 0QR, Scotland Tel: (44) 1355-803-000 Fax: (44) 1355-242-743 Literature Requests www.atmel.com/literature Disclaimer: Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical components in life support devices or systems. © Atmel Corporation 2003. All rights reserved. Atmel ® and combinations thereof are the registered trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be the trademarks of others. Printed on recycled paper. 4560C–AUTO–10/03