MCC omponents 21201 Itasca Street Chatsworth !"# $ % !"# MBR2020 THRU MBR20100 Features • • • • Metal of siliconrectifier, majonty carrier conducton Guard ring for transient protection Low power loss high efficiency High surge capacity, High current capability 20 Amp Schottky Barrier Rectifier 20 to 100 Volts Maximum Ratings • • Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Microsemi Catalog Number MBR2020 MBR2030 MBR2035 MBR2040 MBR2045 MBR2060 MBR2080 MBR20100 Device Marking MBR2020 MBR2030 MBR2035 MBR2040 MBR2045 MBR2060 MBR2080 MBR20100 Maximum Recurrent Peak Reverse Voltage 20V 30V 35V 40V 45V 60V 80V 100V TO-220AC Maximum RMS Voltage Maximum DC Blocking Voltage C B S F Q T 14V 21V 24.5V 28V 31.5V 42V 56V 70V 20V 30V 35V 40V 45V 60V 80V 100V A U H K L D Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Forward Voltage Drop Per Element MBR2020-2045 IF(AV) 20A TC = 135°C IFSM 150A 8.3ms, half sine VF MBR2060 MBR2080-20100 Maximum DC Reverse Current At Rated DC Blocking Voltage .63V .75V .84V IFM = 20A per element; TA = 25°C* IR 0.1mA TJ = 25°C J R G A B C D F G H J K L Q R S T U INCHES .595 .620 .380 .405 .160 .190 .025 .035 .142 .147 .190 .210 .110 .130 .018 .025 .500 .562 .045 .060 .100 .120 .080 .110 .045 .055 .235 .255 -----.050 *Pulse test: Pulse width 300 µsec, Duty cycle 1% www.mccsemi.com MM 15.11 9.65 4.06 0.64 3.61 4.83 2.79 0.46 12.70 1.14 2.54 2.04 1.14 5.97 ----- 15.75 10.29 4.82 0.89 3.73 5.33 3.30 0.64 14.27 1.52 3.04 2.79 1.39 6.48 1.27 MCC MBR2020 thru MBR20100 Figure 1 Typical Forward Characteristics Figure 2 Typical Reverse Characteristics 10 100 MBR2060 60 6 4 40 2 20 MBR2020-1645 1 10 .6 6 .4 4 MBR2080-20100 .2 2 TJ=25°C 25°C µAmps .1 Amps 1 .06 .6 .04 .4 .02 .2 .01 .1 .006 .06 .00 4 .04 .002 .02 .01 .001 20 .2 .3 .4 .5 .6 .7 75 50 100 125 150 175 .8 Volts Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts Figure 3 Forward Derating Curve Figure 4 Peak Forward Surge Current 20 150 18 125 14 100 75 10 Amps Amps 50 8 25 5 0 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 25 50 75 100 125 1 2 4 8 10 20 40 60 80 100 Cycles 150 °C 6 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles Average Forward Rectified Current - Amperesversus Ambient Temperature - °C www.mccsemi.com