KERSEMI MBR1630

omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
MBR1620
THRU
MBR1660
Features
•
•
•
•
Metal of siliconrectifier, majonty carrier conducton
Guard ring for transient protection
Low power loss high efficiency
High surge capacity, High current capability
16 Amp
Schottky Barrier
Rectifier
20 to 60 Volts
Maximum Ratings
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +175°C
Microsemi
Catalog
Number
MBR1620
MBR1630
MBR1635
MBR1640
MBR1645
MBR1660
Device
Marking
MBR1620
MBR1630
MBR1635
MBR1640
MBR1645
MBR1660
Maximum
Recurrent
Peak
Reverse
Voltage
20V
30V
35V
40V
45V
60V
TO-220AC
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
B
L
M
C
D
A
K
14V
21V
24.5V
28V
31.5V
42V
20V
30V
35V
40V
45V
60V
E
PIN
1
2
F
G
I
J
H
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
IF(AV)
16A
TC = 125°C
IFSM
150A
8.3ms, half sine
PIN 1
VF
.63V
.75V
.57V
.65V
IFM = 16A
TJ = 25°C
TJ = 125°C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage MBR1620-1645
IR
0.2mA
1mA
40mA
50mA
TJ = 25°C
T J = 25°C
TJ = 125°C
T J = 125°C
CJ
450pF
Measured at
1.0MHz, VR=4.0V
MBR1660
MBR1620-1645
MBR1660
MBR1660
MBR1620-1645
MBR1660
Typical Junction
Capacitance
CASE
PIN 2
Maximum Forward
Voltage Drop Per
Element MBR1620-1645
N
A
B
C
D
E
F
G
H
I
J
K
L
M
N
INCHES
.560
.625
.380
.420
.100
.135
.230
.270
.380
.420
-----.250
.500
.580
.190
.210
.020
.045
.012
.025
.139
.161
.140
.190
.045
.055
.080
.115
MM
14.22
9.65
2.54
5.84
9.65
-----12.70
4.83
0.51
0.30
3.53
3.56
1.14
2.03
15.88
10.67
3.43
6.86
10.67
6.35
14.73
5.33
1.14
0.64
4.09
4.83
1.40
2.92
www.kersemi.com
MBR1620 thru MBR1660
Figure 1
Typical Forward Characteristics
Figure 2
Typical Reverse Characteristics
10
100
MBR1660
60
6
4
40
2
20
MBR1620-1645
1
10
.6
6
.4
4
TJ=25°C
.2
2
25°C
µAmps .1
Amps 1
.06
.6
.04
.4
.02
.2
.01
.1
.006
.06
.00
4
.04
.002
.02
.01
.001
20
.2
.3
.4
.5
.6
.7
75
50
100
125 150
175
.8
Volts
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 3
Forward Derating Curve
Figure 4
Peak Forward Surge Current
16
150
14
125
12
100
75
10
Amps
Amps
50
8
25
5
0
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
0
25
50
75
100
125
150
°C
1
2
4
6
8 10
20
40
60 80 100
Cycles
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
www.kersemi.com