ATMEL AT49SV163D-80CU

Features
• Single Voltage Read/Write Operation: 1.65V to 1.95V
• Access Time – 80 ns
• Sector Erase Architecture
•
•
•
•
•
•
•
•
•
•
•
•
•
– Thirty-one 32K Word (64K Bytes) Sectors with Individual Write Lockout
– Eight 4K Word (8K Bytes) Sectors with Individual Write Lockout
Fast Word Program Time – 10 µs
Fast Sector Erase Time – 100 ms
Suspend/Resume Feature for Erase and Program
– Supports Reading and Programming from Any Sector by Suspending Erase
of a Different Sector
– Supports Reading Any Word in the Non-suspending Sectors by Suspending
Programming of Any Other Word
Low-power Operation
– 10 mA Active
– 15 µA Standby
Data Polling, Toggle Bit, Ready/Busy for End of Program Detection
VPP Pin for Write Protection and Accelerated Program Operation
RESET Input for Device Initialization
Sector Lockdown Support
TSOP and CBGA Package Options
Top or Bottom Boot Block Configuration Available
128-bit Protection Register
Minimum 100,000 Erase Cycles
Common Flash Interface (CFI)
16-megabit
(1M x 16)
1.8-volt Only
Flash Memory
AT49SV163D
AT49SV163DT
1. Description
The AT49SV163D(T) is a 1.8-volt 16-megabit Flash memory organized as 1,048,576
words of 16 bits each. The memory is divided into 39 sectors for erase operations.
The device is offered in a 48-lead TSOP and a 48-ball CBGA package. The device
has CE and OE control signals to avoid any bus contention. This device can be read
or reprogrammed using a single power supply, making it ideally suited for in-system
programming.
The device powers on in the read mode. Command sequences are used to place the
device in other operation modes such as program and erase. The device has the
capability to protect the data in any sector (see “Sector Lockdown” on page 6).
To increase the flexibility of the device, it contains an Erase Suspend and Program
Suspend feature. This feature will put the erase or program on hold for any amount of
time and let the user read data from or program data to any of the remaining sectors
within the memory. The end of a program or an erase cycle is detected by the
READY/BUSY pin, Data Polling or by the toggle bit.
The VPP pin provides data protection. When the VPP input is below 0.4V, the program
and erase functions are inhibited. When VPP is at 1.65V or above, normal program
and erase operations can be performed. With VPP at 10.0V, the program (Dual-word
Program command) operation is accelerated.
3656A–FLASH–2/07
A six-byte command (Enter Single Pulse Program Mode) sequence to remove the requirement
of entering the three-byte program sequence is offered to further improve programming time.
After entering the six-byte code, only single pulses on the write control lines are required for
writing into the device. This mode (Single Pulse Word Program) is exited by powering down
the device, or by pulsing the RESET pin low for a minimum of 500 ns and then bringing it back
to VCC. Erase, Erase Suspend/Resume and Program Suspend/Resume commands will not
work while in this mode; if entered they will result in data being programmed into the device. It
is not recommended that the six-byte code reside in the software of the final product but only
exist in external programming code.
2. Pin Configurations
2.1
Pin Name
Function
A0 - A19
Addresses
CE
Chip Enable
OE
Output Enable
WE
Write Enable
RESET
Reset
RDY/BUSY
READY/BUSY Output
VPP
Write Protection
I/O0 - I/O15
Data Inputs/Outputs
NC
No Connect
2.2
TSOP Top View (Type 1)
CBGA Top View (Ball Down)
1
A15
A14
A13
A12
A11
A10
A9
A8
A19
NC
WE
RESET
NC
VPP
RDY/BUSY
A18
A17
A7
A6
A5
A4
A3
A2
A1
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
A16
VCC
GND
I/O15
I/O7
I/O14
I/O6
I/O13
I/O5
I/O12
I/O4
VCC
I/O11
I/O3
I/O10
I/O2
I/O9
I/O1
I/O8
I/O0
OE
GND
CE
A0
2
3
4
5
6
A
A3
A7
A4
A17
VPP
A2
A6
A1
RDY/BUSY WE
A9
A13
RST
A8
A12
A18
NC
A10
A14
A5
NC
A19
A11
A15
A0
I/O0
I/O2
I/O5
I/O7
A16
CE
I/O8
I/O10
I/O12
I/O14
NC
OE
I/O9
I/O11
VCC
I/O13
I/015
VSS
I/O1
I/O3
I/O4
I/O6
VSS
B
C
D
E
F
G
H
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
3. Block Diagram
I/O0 - I/O15
INPUT
BUFFER
INPUT
BUFFER
IDENTIFIER
REGISTER
STATUS
REGISTER
DATA
REGISTER
A0 - A19
OUTPUT
MULTIPLEXER
OUTPUT
BUFFER
CE
WE
OE
RESET
COMMAND
REGISTER
ADDRESS
LATCH
DATA
COMPARATOR
Y-DECODER
Y-GATING
RDY/BUSY
WRITE STATE
MACHINE
PROGRAM/ERASE
VOLTAGE SWITCH
VPP
VCC
GND
X-DECODER
MAIN
MEMORY
4. Device Operation
4.1
Command Sequences
When the device is first powered on, it will be reset to the read or standby mode, depending
upon the state of the control line inputs. In order to perform other device functions, a series of
command sequences are entered into the device. The command sequences are shown in the
“Command Definition Table” on page 12 (I/O8 - I/O15 are don’t care inputs for the command
codes). The command sequences are written by applying a low pulse on the WE or CE input
with CE or WE low (respectively) and OE high. The address is latched on the falling edge of
CE or WE, whichever occurs last. The data is latched by the first rising edge of CE or WE.
Standard microprocessor write timings are used. The address locations used in the command
sequences are not affected by entering the command sequences.
3
3656A–FLASH–2/07
4.2
Read
The AT49SV163D(T) is accessed like an EPROM. When CE and OE are low and WE is high,
the data stored at the memory location determined by the address pins are asserted on the
outputs. The outputs are put in the high impedance state whenever CE or OE is high. This
dual-line control gives designers flexibility in preventing bus contention.
4.3
Reset
A RESET input pin is provided to ease some system applications. When RESET is at a logic
high level, the device is in its standard operating mode. A low level on the RESET input halts
the present device operation and puts the outputs of the device in a high impedance state.
When a high level is reasserted on the RESET pin, the device returns to the read or standby
mode, depending upon the state of the control inputs.
4.4
Erase
Before a word can be reprogrammed, it must be erased. The erased state of memory bits is a
logical “1”. The entire device can be erased by using the Chip Erase command or individual
sectors can be erased by using the Sector Erase command.
4.4.1
Chip Erase
The entire device can be erased at one time by using the six-byte chip erase software code.
After the chip erase has been initiated, the device will internally time the erase operation so
that no external clocks are required. The maximum time to erase the chip is tEC.
If the sector lockdown has been enabled, the chip erase will not erase the data in the sector
that has been locked out; it will erase only the unprotected sectors. After the chip erase, the
device will return to the read or standby mode.
4.4.2
Sector Erase
As an alternative to a full chip erase, the device is organized into 39 sectors (SA0 - SA38) that
can be individually erased. The Sector Erase command is a six-bus cycle operation. The sector address is latched on the falling WE edge of the sixth cycle while the 30H data input
command is latched on the rising edge of WE. The sector erase starts after the rising edge of
WE of the sixth cycle. The erase operation is internally controlled; it will automatically time to
completion. The maximum time to erase a sector is tSEC. When the sector programming lockdown feature is not enabled, the sector will erase (from the same Sector Erase command). An
attempt to erase a sector that has been protected will result in the operation terminating
immediately.
4.5
Word Programming
Once a memory block is erased, it is programmed (to a logical “0”) on a word-by-word basis.
Programming is accomplished via the internal device command register and is a four-bus
cycle operation. The device will automatically generate the required internal program pulses.
Any commands written to the chip during the embedded programming cycle will be ignored. If
a hardware reset happens during programming, the data at the location being programmed
will be corrupted. Please note that a data “0” cannot be programmed back to a “1”; only erase
operations can convert “0”s to “1”s. Programming is completed after the specified tBP cycle
time. The Data Polling feature or the Toggle Bit feature may be used to indicate the end of a
program cycle. If the erase/program status bit is a “1”, the device was not able to verify that the
erase or program operation was performed successfully.
4
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
4.6
VPP Pin
The circuitry of the AT49SV163D(T) is designed so that the device cannot be programmed or
erased if the VPP voltage is less that 0.4V. When VPP is at 1.65V or above, normal program
and erase operations can be performed. The VPP pin cannot be left floating.
4.7
Program/Erase Status
The device provides several bits to determine the status of a program or erase operation: I/O2,
I/O3, I/O5, I/O6 and I/O7. The “Status Bit Table” on page 11 and the following four sections
describe the function of these bits. To provide greater flexibility for system designers, the
AT49SV163D(T) contains a programmable configuration register. The configuration register
allows the user to specify the status bit operation. The configuration register can be set to one
of two different values, “00” or “01”. If the configuration register is set to “00”, the part will automatically return to the read mode after a successful program or erase operation. If the
configuration register is set to a “01”, a Product ID Exit command must be given after a successful program or erase operation before the part will return to the read mode. It is important
to note that whether the configuration register is set to a “00” or to a “01”, any unsuccessful
program or erase operation requires using the Product ID Exit command to return the device
to read mode. The default value (after power-up) for the configuration register is “00”. Using
the four-bus cycle Set Configuration Register command as shown in the “Command Definition
Table” on page 12, the value of the configuration register can be changed. Voltages applied to
the RESET pin will not alter the value of the configuration register. The value of the configuration register will affect the operation of the I/O7 status bit as described below.
4.7.1
Data Polling
The AT49SV163D(T) features Data Polling to indicate the end of a program cycle. If the status
configuration register is set to a “00”, during a program cycle an attempted read of the last
word loaded will result in the complement of the loaded data on I/O7. Once the program cycle
has been completed, true data is valid on all outputs and the next cycle may begin. During a
chip or sector erase operation, an attempt to read the device will give a “0” on I/O7. Once the
program or erase cycle has completed, true data will be read from the device. Data Polling
may begin at any time during the program cycle. Please see “Status Bit Table” on page 11 for
more details.
If the status bit configuration register is set to a “01”, the I/O7 status bit will be low while the
device is actively programming or erasing data. I/O7 will go high when the device has completed a program or erase operation. Once I/O7 has gone high, status information on the other
pins can be checked.
The Data Polling status bit must be used in conjunction with the erase/program and VPP status
bit as shown in the algorithm in Figures 4-1 and 4-2 on page 9.
4.7.2
Toggle Bit
In addition to Data Polling the AT49SV163D(T) provides another method for determining the
end of a program or erase cycle. During a program or erase operation, successive attempts to
read data from the memory will result in I/O6 toggling between one and zero. Once the program cycle has completed, I/O6 will stop toggling and valid data will be read. Examining the
toggle bit may begin at any time during a program cycle. Please see “Status Bit Table” on
page 11 for more details.
The toggle bit status bit should be used in conjunction with the erase/program and VPP status
bit as shown in the algorithm in Figures 4-3 and 4-3 on page 10.
5
3656A–FLASH–2/07
4.7.3
Erase/Program Status Bit
The device offers a status bit on I/O5, which indicates whether the program or erase operation
has exceeded a specified internal pulse count limit. If the status bit is a “1”, the device is
unable to verify that an erase or a word program operation has been successfully performed. If
a program (Sector Erase) command is issued to a protected sector, the protected sector will
not be programmed (erased). The device will go to a status read mode and the I/O5 status bit
will be set high, indicating the program (erase) operation did not complete as requested. Once
the erase/program status bit has been set to a “1”, the system must write the Product ID Exit
command to return to the read mode. The erase/program status bit is a “0” while the erase or
program operation is still in progress. Please see “Status Bit Table” on page 11 for more
details.
4.7.4
VPP Status Bit
The AT49SV163D(T) provides a status bit on I/O3, which provides information regarding the
voltage level of the VPP pin. During a program or erase operation, if the voltage on the VPP
pin is not high enough to perform the desired operation successfully, the I/O3 status bit will be
a “1”. Once the VPP status bit has been set to a “1”, the system must write the Product ID Exit
command to return to the read mode. On the other hand, if the voltage level is high enough to
perform a program or erase operation successfully, the VPP status bit will output a “0”. Please
see “Status Bit Table” on page 11 for more details.
4.8
Sector Lockdown
Each sector has a programming lockdown feature. This feature prevents programming of data
in the designated sectors once the feature has been enabled. These sectors can contain
secure code that is used to bring up the system. Enabling the lockdown feature will allow the
boot code to stay in the device while data in the rest of the device is updated. This feature
does not have to be activated; any sector’s usage as a write-protected region is optional to the
user.
At power-up or reset, all sectors are unlocked. To activate the lockdown for a specific sector,
the six-bus cycle Sector Lockdown command must be issued. Once a sector has been locked
down, the contents of the sector is read-only and cannot be erased or programmed.
4.8.1
Sector Lockdown Detection
A software method is available to determine if programming of a sector is locked down. When
the device is in the software product identification mode (see “Software Product Identification
Entry/Exit” sections on page 23), a read from address location 00002H within a sector will
show if programming the sector is locked down. If the data on I/O0 is low, the sector can be
programmed; if the data on I/O0 is high, the program lockdown feature has been enabled and
the sector cannot be programmed. The software product identification exit code should be
used to return to standard operation.
4.8.2
Sector Lockdown Override
The only way to unlock a sector that is locked down is through reset or power-up cycles. After
power-up or reset, the content of a sector that is locked down can be erased and
reprogrammed.
6
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
4.9
Erase Suspend/Erase Resume
The Erase Suspend command allows the system to interrupt a sector or chip erase operation
and then program or read data from a different sector within the memory. After the Erase Suspend command is given, the device requires a maximum time of 15 µs to suspend the erase
operation. After the erase operation has been suspended, the system can then read data or
program data to any other sector within the device. An address is not required during the
Erase Suspend command. During a sector erase suspend, another sector cannot be erased.
To resume the sector erase operation, the system must write the Erase Resume command.
The Erase Resume command is a one-bus cycle command. The device also supports an
erase suspend during a complete chip erase. While the chip erase is suspended, the user can
read from any sector within the memory that is protected. The command sequence for a chip
erase suspend and a sector erase suspend are the same.
4.10
Program Suspend/Program Resume
The Program Suspend command allows the system to interrupt a programming operation and
then read data from a different word within the memory. After the Program Suspend command
is given, the device requires a maximum of 20 µs to suspend the programming operation. After
the programming operation has been suspended, the system can then read data from any
other word that is not contained in the sector in which the programming operation was suspended. An address is not required during the program suspend operation. To resume the
programming operation, the system must write the Program Resume command. The program
suspend and resume are one-bus cycle commands. The command sequence for the erase
suspend and program suspend are the same, and the command sequence for the erase
resume and program resume are the same.
4.11
Product Identification
The product identification mode identifies the device and manufacturer as Atmel ® . It is
accessed using a software operation.
For details, see “Operating Modes” on page 16 or “Software Product Identification Entry/Exit”
sections on page 23.
4.12
128-bit Protection Register
The AT49SV163D(T) contains a 128-bit register that can be used for security purposes in system design. The protection register is divided into two 64-bit blocks. The two blocks are
designated as block A and block B. The data in block A is non-changeable and is programmed
at the factory with a unique number. The data in block B is programmed by the user and can
be locked out such that data in the block cannot be reprogrammed. To program block B in the
protection register, the four-bus cycle Program Protection Register command must be used as
shown in the “Command Definition Table” on page 12. To lock out block B, the four-bus cycle
Lock Protection Register command must be used as shown in the “Command Definition
Table” . Data bit D1 must be zero during the fourth bus cycle. All other data bits during the
fourth bus cycle are don’t cares. To determine whether block B is locked out, the Product ID
Entry command is given followed by a read operation from address 80H. If data bit D1 is zero,
block B is locked. If data bit D1 is one, block B can be reprogrammed. Please see the “Protection Register Addressing Table” on page 13 for the address locations in the protection register.
To read the protection register, the Product ID Entry command is given followed by a normal
read operation from an address within the protection register. After determining whether block
B is protected or not, or reading the protection register, the Product ID Exit command must be
given prior to performing any other operation.
7
3656A–FLASH–2/07
4.13
RDY/BUSY
An open-drain READY/BUSY output pin provides another method of detecting the end of a
program or erase operation. RDY/BUSY is actively pulled low during the internal program and
erase cycles and is released at the completion of the cycle. The open-drain connection allows
for OR-tying of several devices to the same RDY/BUSY line. Please see “Status Bit Table” on
page 11 for more details.
4.14
Common Flash Interface (CFI)
CFI is a published, standardized data structure that may be read from a flash device. CFI
allows system software to query the installed device to determine the configurations, various
electrical and timing parameters, and functions supported by the device. CFI is used to allow
the system to learn how to interface to the flash device most optimally. The two primary benefits of using CFI are ease of upgrading and second source availability. The command to enter
the CFI Query mode is a one-bus cycle command which requires writing data 98h to address
55h. The CFI Query command can be written when the device is ready to read data or can
also be written when the part is in the product ID mode. Once in the CFI Query mode, the system can read CFI data at the addresses given in “Common Flash Interface Definition Table”
on page 24. To exit the CFI Query mode, the product ID exit command must be given.
4.15
Hardware Data Protection
The Hardware Data Protection feature protects against inadvertent programs to the
AT49SV163D(T) in the following ways: (a) VCC sense: if VCC is below 1.65V (typical), the program function is inhibited. (b) VCC power-on delay: once VCC has reached the VCC sense level,
the device will automatically time out 10 ms (typical) before programming. (c) Program inhibit:
holding any one of OE low, CE high or WE high inhibits program cycles. (d) Program inhibit:
VPP is less than VILPP.
4.16
Input Levels
While operating with a 1.65V to 1.95V power supply, the address inputs and control inputs
(OE, CE and WE) may be driven from 0 to 5.5V without adversely affecting the operation of
the device. The I/O lines can only be driven from 0 to VCC + 0.6V.
8
AT49SV163D(T)
3656A–FLASH–2/07
Figure 4-1.
Data Polling Algorithm
(Configuration Register = 00)
Figure 4-2.
START
START
Read I/O7 - I/O0
Addr = VA
Read I/O7 - I/O0
Addr = VA
I/O7 = Data?
YES
I/O7 = Data?
NO
NO
NO
I/O3, I/O5 = 1?
Read I/O7 - I/O0
Addr = VA
YES
I/O7 = Data?
NO
Program/Erase
Operation Not
Successful, Write
Product ID
Exit Command
9
I/O3, I/O5 = 1?
YES
Read I/O7 - I/O0
Addr = VA
I/O7 = Data?
YES
NO
YES
Notes:
Data Polling Algorithm
(Configuration Register = 01)
YES
NO
Program/Erase
Operation Not
Successful, Write
Product ID
Exit Command
Program/Erase
Operation
Successful,
Device in
Read Mode
1. VA = Valid address for programming. During a sector
erase operation, a valid address is any sector
address within the sector being erased. During chip
erase, a valid address is any non-protected sector
address.
2. I/O7 should be rechecked even if I/O5 = “1” because
I/O7 may change simultaneously with I/O5.
Notes:
Program/Erase
Operation
Successful,
Write Product ID
Exit Command
1. VA = Valid address for programming. During a sector
erase operation, a valid address is any sector
address within the sector being erased. During chip
erase, a valid address is any non-protected sector
address.
2. I/O7 should be rechecked even if I/O5 = “1” because
I/O7 may change simultaneously with I/O5.
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
Figure 4-3.
Toggle Bit Algorithm
(Configuration Register = 00)
Figure 4-4.
START
START
Read I/O7 - I/O0
Read I/O7 - I/O0
Read I/O7 - I/O0
Read I/O7 - I/O0
Toggle Bit =
Toggle?
NO
Toggle Bit =
Toggle?
NO
NO
I/O3, I/O5 = 1?
YES
Read I/O7 - I/O0
Twice
NO
Toggle Bit =
Toggle?
YES
Program/Erase
Operation Not
Successful, Write
Product ID
Exit Command
I/O3, I/O5 = 1?
YES
Read I/O7 - I/O0
Twice
Toggle Bit =
Toggle?
NO
YES
YES
Note:
Toggle Bit Algorithm
(Configuration Register = 01)
NO
YES
Program/Erase
Operation Not
Successful, Write
Product ID
Exit Command
Program/Erase
Operation
Successful, Device
in Read Mode
1. The system should recheck the toggle bit even if
I/O5 = “1” because the toggle bit may stop toggling
as I/O5 changes to “1”.
Note:
Program/Erase
Operation
Successful,
Write Product ID
Exit Command
1. The system should recheck the toggle bit even if
I/O5 = “1” because the toggle bit may stop toggling
as I/O5 changes to “1”.
10
3656A–FLASH–2/07
AT49SV163D(T)
5. Status Bit Table
Status Bit
I/O7
I/O7
I/O6
I/O5(1)
I/O3(2)
I/O2
RDY/BUSY
00
01
00/01
00/01
00/01
00/01
00/01
I/O7
0
TOGGLE
0
0
1
0
Erasing
0
0
TOGGLE
0
0
TOGGLE
0
Erase Suspended & Read
Erasing Sector
1
1
1
0
0
TOGGLE
1
Erase Suspended & Read
Non-erasing Sector
DATA
DATA
DATA
DATA
DATA
DATA
1
Erase Suspended &
Program Non-erasing Sector
I/O7
0
TOGGLE
0
0
TOGGLE
0
Erase Suspended &
Program Suspended and
Reading from Nonsuspended Sectors
DATA
DATA
DATA
DATA
DATA
DATA
1
Program Suspended & Read
Programming Sector
I/O7
1
1
0
0
TOGGLE
1
Program Suspended & Read
Non-programming Sector
DATA
DATA
DATA
DATA
DATA
DATA
1
Configuration Register
Programming
Notes:
1. I/O5 switches to a “1” when a program or an erase operation has exceeded the maximum time limits or when a program or
sector erase operation is performed on a protected sector.
2. I/O3 switches to a “1” when the VPP level is not high enough to successfully perform program and erase operations.
11
3656A–FLASH–2/07
6. Command Definition Table
Command
Sequence
1st Bus
Cycle
Bus
Cycles
Addr
Data
Read
1
Addr
DOUT
Chip Erase
6
555
AA
2nd Bus
Cycle
3rd Bus
Cycle
4th Bus
Cycle
5th Bus
Cycle
Addr
Data
Addr
Data
Addr
Data
Addr
Data
Addr
Data
AAA(2)
55
555
80
555
AA
AAA
55
555
10
Sector Erase
6
555
AA
AAA
55
555
80
555
AA
Word Program
4
555
AA
AAA
55
555
A0
Addr
DIN
Dual Word
Program(4)
5
555
AA
AAA
55
555
E0
Addr0
Enter Single Pulse
Program Mode
6
555
AA
AAA
55
555
80
Single Pulse Word
Program
1
Addr
DIN
Sector Lockdown
6
555
AA
AAA(2)
55
555
80
Erase/Program
Suspend
1
XXX
B0
Erase/Program
Resume
1
XXX
30
Product ID Entry
3
555
AA
AAA
55
555
90
Product ID Exit(6)
3
555
AA
AAA
55
555
F0(7)
Product ID Exit(6)
1
XXX
F0(7)
Program Protection
Register
4
555
AA
AAA
55
555
Lock Protection
Register - Block B
4
555
AA
AAA
55
Status of Block B
Protection
4
555
AA
AAA
Set Configuration
Register
4
555
AA
AAA
CFI Query(11)
1
X55
98
Notes:
12
6th Bus
Cycle
SA
(3)
AAA
55
DIN0
Addr1
DIN1
555
AA
AAA
55
555
A0
555
AA
AAA
55
SA(3)(5)
60
C0
Addr(8)
DIN
555
C0
080
X0
55
555
90
80
DOUT(9)
55
555
D0
XXX
00/01(10)
30
1. The DATA FORMAT shown for each bus cycle is as follows; I/O7 - I/O0 (Hex). I/O15 - I/O8 are don’t care. The ADDRESS
FORMAT shown for each bus cycle is as follows: A11 - A0 (Hex). Address A19 through A11 are don’t care.
2. Since A11 is a Don’t Care, AAA can be replaced with 2AA.
3. SA = sector address. Any word address within a sector can be used to designate the sector address (see pages 14 - 15 for
details).
4. This fast programming option enables the user to program two words in parallel only when VPP = 9.5V. The Addresses,
Addr0 and Addr1, of the two words, DIN0 and DIN1, must only differ in address A0. This command should be used during
manufacturing purposes only.
5. Once a sector is in the lockdown mode, data in the protected sector cannot be changed unless the chip is reset or
power cycled.
6. Either one of the Product ID Exit commands can be used.
7. Bytes of data other than F0 may be used to exit the Product ID mode. However, it is recommended that F0 be used.
8. Any addresses within the user programmable protection register region. Address locations are shown on “Protection Register Addressing Table” on page 13.
9. If data bit D1 is “0”, block B is locked. If data bit D1 is “1”, block B can be reprogrammed.
10. The default state (after power-up) of the configuration register is “00”.
11. When accessing the data in the CFI table, the address format is A15 - A0 (Hex).
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
7. Absolute Maximum Ratings*
*NOTICE:
Temperature under Bias ................................ -55°C to +125°C
Storage Temperature ..................................... -65°C to +150°C
All Input Voltages
(including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V
All Output Voltages
with Respect to Ground .............................-0.6V to VCC + 0.6V
Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Voltage on VPP
with Respect to Ground ....................................-0.6V to + 9.5V
8. Protection Register Addressing Table
Address
Use
Block
A7
A6
A5
A4
A3
A2
A1
A0
81
Factory
A
1
0
0
0
0
0
0
1
82
Factory
A
1
0
0
0
0
0
1
0
83
Factory
A
1
0
0
0
0
0
1
1
84
Factory
A
1
0
0
0
0
1
0
0
85
User
B
1
0
0
0
0
1
0
1
86
User
B
1
0
0
0
0
1
1
0
87
User
B
1
0
0
0
0
1
1
1
88
User
B
1
0
0
0
1
0
0
0
Note:
All address lines not specified in the above table must be “0” when accessing the protection register, i.e., A19 - A8 = 0.
13
3656A–FLASH–2/07
9. AT49SV163D – Sector Address Table
Sector
Size (Bytes/Words)
Address Range (A19 - A0)
SA0
8K/4K
00000 - 00FFF
SA1
8K/4K
01000 - 01FFF
SA2
8K/4K
02000 - 02FFF
SA3
8K/4K
03000 - 03FFF
SA4
8K/4K
04000 - 04FFF
SA5
8K/4K
05000 - 05FFF
SA6
8K/4K
06000 - 06FFF
SA7
8K/4K
07000 - 07FFF
SA8
64K/32K
08000 - 0FFFF
SA9
64K/32K
10000 - 17FFF
SA10
64K/32K
18000 - 1FFFF
SA11
64K/32K
20000 - 27FFF
SA12
64K/32K
28000 - 2FFFF
SA13
64K/32K
30000 - 37FFF
SA14
64K/32K
38000 - 3FFFF
SA15
64K/32K
40000 - 47FFF
SA16
64K/32K
48000 - 4FFFF
SA17
64K/32K
50000 - 57FFF
SA18
64K/32K
58000 - 5FFFF
SA19
64K/32K
60000 - 67FFF
SA20
64K/32K
68000 - 6FFFF
SA21
64K/32K
70000 - 77FFF
SA22
64K/32K
78000 - 7FFFF
SA23
64K/32K
80000 - 87FFF
SA24
64K/32K
88000 - 8FFFF
SA25
64K/32K
90000 - 97FFF
SA26
64K/32K
98000 - 9FFFF
SA27
64K/32K
A0000 - A7FFF
SA28
64K/32K
A8000 - AFFFF
SA29
64K/32K
B0000 - B7FFF
SA30
64K/32K
B8000 - BFFFF
SA31
64K/32K
C0000 - C7FFF
SA32
64K/32K
C8000 - CFFFF
SA33
64K/32K
D0000 - D7FFF
SA34
64K/32K
D8000 - DFFFF
SA35
64K/32K
E0000 - E7FFF
SA36
64K/32K
E8000 - EFFFF
SA37
64K/32K
F0000 - F7FFF
SA38
64K/32K
F8000 - FFFFF
14
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
10. AT49SV163DT – Sector Address Table
Sector
Size (Bytes/Words)
Address Range (A19 - A0)
SA0
64K/32K
00000 - 07FFF
SA1
64K/32K
08000 - 0FFFF
SA2
64K/32K
10000 - 17FFF
SA3
64K/32K
18000 - 1FFFF
SA4
64K/32K
20000 - 27FFF
SA5
64K/32K
28000 - 2FFFF
SA6
64K/32K
30000 - 37FFF
SA7
64K/32K
38000 - 3FFFF
SA8
64K/32K
40000 - 47FFF
SA9
64K/32K
48000 - 4FFFF
SA10
64K/32K
50000 - 57FFF
SA11
64K/32K
58000 - 5FFFF
SA12
64K/32K
60000 - 67FFF
SA13
64K/32K
68000 - 6FFFF
SA14
64K/32K
70000 - 77FFF
SA15
64K/32K
78000 - 7FFFF
SA16
64K/32K
80000 - 87FFF
SA17
64K/32K
88000 - 8FFFF
SA18
64K/32K
90000 - 97FFF
SA19
64K/32K
98000 - 9FFFF
SA20
64K/32K
A0000 - A7FFF
SA21
64K/32K
A8000 - AFFFF
SA22
64K/32K
B0000 - B7FFF
SA23
64K/32K
B8000 - BFFFF
SA24
64K/32K
C0000 - C7FFF
SA25
64K/32K
C8000 - CFFFF
SA26
64K/32K
D0000 - D7FFF
SA27
64K/32K
D8000 - DFFFF
SA28
64K/32K
E0000 - E7FFF
SA29
64K/32K
E8000 - EFFFF
SA30
64K/32K
F0000 - F7FFF
SA31
8K/4K
F8000 - F8FFF
SA32
8K/4K
F9000 - F9FFF
SA33
8K/4K
FA000 - FAFFF
SA34
8K/4K
FB000 - FBFFF
SA35
8K/4K
FC000 - FCFFF
SA36
8K/4K
FD000 - FDFFF
SA37
8K/4K
FE000 - FEFFF
SA38
8K/4K
FF000 - FFFFF
15
3656A–FLASH–2/07
11. DC and AC Operating Range
AT49SV163D(T)-80
Operating Temperature (Case)
Ind.
-40°C - 85°C
VCC Power Supply
1.65V to 1.95V
12. Operating Modes
Mode
CE
Read
VIL
Program/Erase
(3)
OE
VIL
WE
VIH
RESET
VIH
VPP(1)
X
(2)
VIL
VIH
VIL
VIH
VIH
X(2)
X
VIH
X
X
X
VIH
VIH
X
X
VIL
X
VIH
X
X
X
X
VIH
VILPP(5)
Output Disable
X
VIH
X
VIH
X
Reset
X
X
X
VIL
X
Standby/Program Inhibit
Program Inhibit
Product Identification
Software(6)
Notes:
16
1.
2.
3.
4.
5.
6.
7.
VIH
VIHPP
(4)
Ai
I/O
Ai
DOUT
Ai
DIN
X
High-Z
High-Z
X
High-Z
A0 = VIL, A1 - A19 = VIL
Manufacturer Code(7)
A0 = VIH, A1 - A19 = VIL
Device Code(7)
The VPP pin can be tied to VCC. For faster program operations, VPP can be set to 9.5V ± 0.5V.
X can be VIL or VIH.
Refer to “Program Cycle Waveforms” on page 21.
VIHPP (min) = 1.65V
VILPP (max) = 0.4V.
See details under “Software Product Identification Entry/Exit” on page 23.
Manufacturer Code: 001FH, Device Code: 02C0H - AT49SV163D;
02C2H (x16) - AT49SV163DT.
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
13. DC Characteristics
Symbol
Parameter
Condition
ILI
Input Load Current
ILO
Max
Units
VIN = 0V to VCC
2
µA
Output Leakage Current
VI/O = 0V to VCC
2
µA
ISB
VCC Standby Current CMOS
CE = VCC - 0.3V to VCC
15
25
µA
ICC(1)
VCC Active Read Current
f = 5 MHz; IOUT = 0 mA
10
15
mA
ICC1
VCC Programming Current
15
mA
IPP1
VPP Input Load Current
10
µA
VIL
Input Low Voltage
0.4
V
VIH
Input High Voltage
VOL1
Output Low Voltage
IOL = 2.1 mA
0.25
V
VOL2
Output Low Voltage
IOL = 1.0 mA
0.1
V
VOH1
Output High Voltage
IOH = -400 µA
1.4
V
VOH2
Output High Voltage
IOH = -100 µA
VCC - 0.1
V
Note:
Min
Typ
VCC - 0.2
V
1. In the erase mode, ICC is 15 mA.
17
3656A–FLASH–2/07
14. Input Test Waveforms and Measurement Level
0.9V
tR, tF < 5 ns
15. Output Test Load
16. Pin Capacitance
f = 1 MHz, T = 25°C(1)
Symbol
Typ
Max
Units
Conditions
CIN
4
6
pF
VIN = 0V
COUT
8
12
pF
VOUT = 0V
Note:
18
1. This parameter is characterized and is not 100% tested.
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
17. AC Read Characteristics
AT49SV163D(T)-80
Symbol
Parameter
Min
Max
Units
tRC
Read Cycle Time
80
tACC
Address to Output Delay
80
ns
tCE(1)
CE to Output Delay
80
ns
(2)
ns
OE to Output Delay
0
35
ns
tDF(3)(4)
CE or OE to Output Float
0
25
ns
tOH
Output Hold from OE, CE or Address,
whichever occurred first
0
tRO
RESET to Output Delay
tOE
ns
100
ns
18. AC Read Waveforms(1)(2)(3)(4)
tRC
ADDRESS
ADDRESS VALID
CE
tCE
tOE
OE
tDF
tOH
tACC
tRO
RESET
OUTPUT
Notes:
HIGH Z
OUTPUT
VALID
1. CE may be delayed up to tACC - tCE after the address transition without impact on tACC.
2. OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE or by tACC - tOE after an address change
without impact on tACC.
3. tDF is specified from OE or CE, whichever occurs first (CL = 5 pF).
4. This parameter is characterized and is not 100% tested.
19
3656A–FLASH–2/07
19. AC Word Load Characteristics
Symbol
Parameter
Min
Max
Units
tAS, tOES
Address, OE Setup Time
0
ns
tAH
Address Hold Time
25
ns
tCS
Chip Select Setup Time
0
ns
tCH
Chip Select Hold Time
0
ns
tWP
Write Pulse Width (WE or CE)
35
ns
tWPH
Write Pulse Width High
15
ns
tDS
Data Setup Time
25
ns
tDH, tOEH
Data, OE Hold Time
0
ns
20. AC Word Load Waveforms
20.1
WE Controlled
20.2
CE Controlled
20
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
21. Program Cycle Characteristics
Symbol
Parameter
tBP
Min
Typ
Max
Units
Word Programming Time
10
120
µs
tBPD
Word Programming Time in Dual Programming Mode
5
60
µs
tAS
Address Setup Time
0
ns
tAH
Address Hold Time
25
ns
tDS
Data Setup Time
25
ns
tDH
Data Hold Time
0
ns
tWP
Write Pulse Width
35
ns
tWPH
Write Pulse Width High
15
ns
tWC
Write Cycle Time
70
ns
tRP
Reset Pulse Width
500
ns
tEC
Chip Erase Cycle Time
16
tSEC1
Sector Erase Cycle Time (4K Word Sectors)
0.1
2.0
seconds
tSEC2
Sector Erase Cycle Time (32K Word Sectors)
0.5
6.0
seconds
tES
Erase Suspend Time
15
µs
tPS
Program Suspend Time
10
µs
seconds
22. Program Cycle Waveforms
PROGRAM CYCLE
OE
CE
tWP
tBP
tWPH
WE
tAS
A0 - A19
tAH
tDH
555
DATA
555
AAA
tWC
555
ADDRESS
tDS
55
AA
INPUT
DATA
A0
AA
23. Sector or Chip Erase Cycle Waveforms
OE
(1)
CE
tWP
tWPH
WE
tAS
A0-A19
tAH
555
Notes:
555
555
AAA
tWC
DATA
tDH
Note 2
AAA
tEC
tDS
AA
55
80
AA
55
Note 3
WORD 0
WORD 1
WORD 2
WORD 3
WORD 4
WORD 5
1. OE must be high only when WE and CE are both low.
2. For chip erase, the address should be 555. For sector erase, the address depends on what sector is to be erased.
(See note 3 under “Command Definition Table” on page 12.)
3. For chip erase, the data should be 10H, and for sector erase, the data should be 30H.
21
3656A–FLASH–2/07
24. Data Polling Characteristics(1)
Symbol
Parameter
tDH
Data Hold Time
tOEH
OE Hold Time
Typ
Max
ns
10
ns
OE to Output Delay
tWR
Units
10
(2)
tOE
Notes:
Min
ns
Write Recovery Time
0
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in “AC Read Characteristics” on page 19.
25. Data Polling Waveforms
WE
CE
tOEH
OE
tDH
I/O7
tOE
An
A0-A19
tWR
HIGH Z
An
An
An
An
26. Toggle Bit Characteristics(1)
Symbol
Parameter
tDH
Data Hold Time
tOEH
OE Hold Time
Min
Typ
Max
Units
10
ns
10
ns
(2)
tOE
OE to Output Delay
tOEHP
OE High Pulse
50
ns
tWR
Write Recovery Time
0
ns
Notes:
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in “AC Read Characteristics” on page 19.
27. Toggle Bit Waveforms(1)(2)(3)
Notes:
22
1. Toggling either OE or CE or both OE and CE will operate toggle bit. The tOEHP specification must be met by the toggling
input(s).
2. Beginning and ending state of I/O6 will vary.
3. Any address location may be used but the address should not vary.
AT49SV163D(T)
3656A–FLASH–2/07
28. Software Product Identification
Entry(1)
30. Sector Lockdown Enable
Algorithm(1)
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA 90
TO
ADDRESS 555
LOAD DATA 80
TO
ADDRESS 555
ENTER PRODUCT
IDENTIFICATION
MODE(2)(3)(5)
LOAD DATA AA
TO
ADDRESS 555
29. Software Product Identification
Exit(1)(6)
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
OR
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA F0
TO
ANY ADDRESS
EXIT PRODUCT
IDENTIFICATION
MODE(4)
LOAD DATA 60
TO
SECTOR ADDRESS
LOAD DATA F0
TO
ADDRESS 555
PAUSE 200 µs(2)
EXIT PRODUCT
IDENTIFICATION
MODE(4)
Notes:
1. Data Format: I/O15 - I/O8 (Don’t Care); I/O7 - I/O0 (Hex)
2.
3.
4.
5.
6.
23
Address Format: A11 - A0 (Hex), A-1, and A11 - A19
(Don’t Care).
A1 - A19 = VIL. Manufacturer Code is read for A0 = VIL;
Device Code is read for A0 = VIH. Additional Device Code is
read from address 0003H.
The device does not remain in identification mode if
powered down.
The device returns to standard operation mode.
Manufacturer Code: 001FH
Device Code: 02C0H – AT49SV163D;
02C2H – AT49SV163DT.
Additional Device Code: 0001H – AT49SV163D(T)
Either one of the Product ID Exit commands can be used.
Notes:
1. Data Format: I/O15 - I/O8 (Don’t Care); I/O7 - I/O0 (Hex)
Address Format: A11 - A0 (Hex), A-1, and A11 - A19
(Don’t Care).
2. Sector Lockdown feature enabled.
AT49SV163D(T)
3656A–FLASH–2/07
31. Common Flash Interface Definition Table
24
Address
Data
Comments
10h
0051h
“Q”
11h
0052h
“R”
12h
0059h
“Y”
13h
0002h
14h
0000h
15h
0041h
16h
0000h
17h
0000h
18h
0000h
19h
0000h
1Ah
0000h
1Bh
0017h
VCC min write/erase
1Ch
0019h
VCC max write/erase
1Dh
0090h
VPP min voltage
1Eh
00A0h
VPP max voltage
1Fh
0004h
Typ word write – 10 µs
20h
0002h
Typ dual word program time – 5 µs
21h
0009h
Typ sector erase, 500 ms
22h
000Eh
Typ chip erase, 16,000 ms
23h
0004h
Max word write/typ time
24h
0004h
Max dual word program time/typ time
25h
0004h
Max sector erase/typ sector erase
26h
0004h
Max chip erase/ typ chip erase
27h
0015h
Device size
28h
0001h
x16 device
29h
0000h
x16 device
2Ah
0002h
Max number of bytes in multiple byte write = 4
2Bh
0000h
Max number of bytes in multiple byte write = 4
2Ch
0002h
2 regions, x = 2
2Dh
0007h
8K bytes, Y = 7
2Eh
0000h
8K bytes, Y = 7
2Fh
0020h
8K bytes, Z = 32
30h
0000h
8K bytes, Z = 32
31h
001Eh
64K bytes, Y = 30
32h
0000h
64K bytes, Y = 30
33h
0000h
64K bytes, Z = 256
34h
0001h
64K bytes, Z = 256
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
31. Common Flash Interface Definition Table (Continued)
Address
Data
Comments
VENDOR SPECIFIC EXTENDED QUERY
41h
0050h
“P”
42h
0052h
“R”
43h
0049h
“I”
44h
0031h
Major version number, ASCII
45h
0030h
Minor version number, ASCII
Bit 0 – chip erase supported, 0 – no, 1 – yes
Bit 1 – erase suspend supported, 0 – no, 1 – yes
Bit 2 – program suspend supported, 0 – no, 1 – yes
46h
0087h
Bit 3 – simultaneous operations supported,
0 – no, 1 – yes
Bit 4 – burst mode read supported, 0 – no, 1 – yes
Bit 5 – page mode read supported, 0 – no, 1 – yes
Bit 6 – queued erase supported, 0 – no, 1 – yes
Bit 7 – protection bits supported, 0 – no, 1 – yes
47h
0000h (top)
or
0001h (bottom)
Bit 0 – top (“0”) or bottom (“1”) boot block device undefined bits are “0”
Bit 0 – 4 word linear burst with wrap around,
0 – no, 1 – yes
48h
0000h
Bit 1 – 8 word linear burst with wrap around,
0 – no, 1 – yes
Bit 2 – continuos burst, 0 - no, 1 - yes
Undefined bits are “0”
Bit 0 – 4 word page, 0 – no, 1 – yes
49h
0000h
Bit 1 – 8 word page, 0 – no, 1 – yes
Undefined bits are “0”
4Ah
0080h
Location of protection register lock byte, the section’s first byte
4Bh
0003h
# of bytes in the factory prog section of prot register – 2*n
4Ch
0003h
# of bytes in the user prog section of prot register – 2*n
25
3656A–FLASH–2/07
32. Ordering Information
32.1
Green Package (Pb/Halide-free)
ICC (mA)
tACC
(ns)
Active
Standby
Ordering Code
Package
Operation Range
80
25
0.025
AT49SV163D-80CU
AT49SV163D-80TU
48C17
48T
Industrial
(-40° to 85° C)
80
25
0.025
AT49SV163DT-80CU
AT49SV163DT-80TU
48C17
48T
Industrial
(-40° to 85° C)
Package Type
48C17
48-ball, Plastic Chip-Size Ball Grid Array Package (CBGA)
48T
48-lead, Plastic Thin Small Outline Package (TSOP)
26
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
33. Packaging Information
33.1
48C17 – CBGA
E
A1 Ball ID
D
A1
Top View
A
Side View
E1
1.50 REF
e
A1 Ball Corner
2.20 REF
A
COMMON DIMENSIONS
(Unit of Measure = mm)
B
C
SYMBOL
D
D1
E
E
F
E1
G
D
MIN
NOM
MAX
6.9
7.0
7.1
NOTE
4.0 TYP
9.9
10.0
10.1
H
e
6
5
4
3
2
1
Øb
Bottom View
D1
5.6 TYP
A
–
–
1.0
A1
0.20
–
–
e
Ø
0.80 BSC
b
0.35 TYP
10/26/05
R
2325 Orchard Parkway
San Jose, CA 95131
TITLE
48C17, 48-ball (6 x 8 Array), 0.80 mm Pitch,
7.0 x 10.0 x 1.0 mm Chip-scale Ball Grid Array Package (CBGA)
DRAWING NO.
48C17
REV.
B
27
3656A–FLASH–2/07
33.2
48T – TSOP
PIN 1
0º ~ 8º
c
Pin 1 Identifier
D1 D
L
b
e
L1
A2
E
A
GAGE PLANE
SEATING PLANE
COMMON DIMENSIONS
(Unit of Measure = mm)
A1
MIN
NOM
MAX
A
–
–
1.20
A1
0.05
–
0.15
A2
0.95
1.00
1.05
D
19.80
20.00
20.20
D1
18.30
18.40
18.50
Note 2
E
11.90
12.00
12.10
Note 2
L
0.50
0.60
0.70
SYMBOL
Notes:
1. This package conforms to JEDEC reference MO-142, Variation DD.
2. Dimensions D1 and E do not include mold protrusion. Allowable
protrusion on E is 0.15 mm per side and on D1 is 0.25 mm per side.
3. Lead coplanarity is 0.10 mm maximum.
L1
0.25 BASIC
b
0.17
0.22
0.27
c
0.10
–
0.21
e
NOTE
0.50 BASIC
10/18/01
R
28
2325 Orchard Parkway
San Jose, CA 95131
TITLE
48T, 48-lead (12 x 20 mm Package) Plastic Thin Small Outline
Package, Type I (TSOP)
DRAWING NO.
REV.
48T
B
AT49SV163D(T)
3656A–FLASH–2/07
AT49SV163D(T)
34. Revision History
Revision No.
History
Revision A – February 2007
•
Initial Web Release
29
3656A–FLASH–2/07
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Regional Headquarters
Europe
Atmel Sarl
Route des Arsenaux 41
Case Postale 80
CH-1705 Fribourg
Switzerland
Tel: (41) 26-426-5555
Fax: (41) 26-426-5500
Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Atmel Operations
Memory
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
RF/Automotive
Theresienstrasse 2
Postfach 3535
74025 Heilbronn, Germany
Tel: (49) 71-31-67-0
Fax: (49) 71-31-67-2340
Microcontrollers
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
La Chantrerie
BP 70602
44306 Nantes Cedex 3, France
Tel: (33) 2-40-18-18-18
Fax: (33) 2-40-18-19-60
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Biometrics
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex, France
Tel: (33) 4-76-58-47-50
Fax: (33) 4-76-58-47-60
ASIC/ASSP/Smart Cards
Zone Industrielle
13106 Rousset Cedex, France
Tel: (33) 4-42-53-60-00
Fax: (33) 4-42-53-60-01
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Scottish Enterprise Technology Park
Maxwell Building
East Kilbride G75 0QR, Scotland
Tel: (44) 1355-803-000
Fax: (44) 1355-242-743
Literature Requests
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY
WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT
OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no
representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications
and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Unless specifically provided
otherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel’s products are not intended, authorized, or warranted for use
as components in applications intended to support or sustain life.
© 2007 Atmel Corporation. All rights reserved. Atmel ®, logo and combinations thereof, Everywhere You Are® and others are registered trademarks or trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
3656A–FLASH–2/07