MURATA UQQ-15/7-Q12P-C

UQQ Series
Wide Input Range Single Output DC/DC Converters
For applications requiring wide range input, improved electrical and
thermal perfomance consider Murata Power Solutions’ new UQQ
Series “Quarter-Brick” DC/DC Converters. They measure just 1.45
x 2.22 x 0.43 inches (36.8 x 56.4 x 10.92mm) and fit the industrystandard footprint.
Typical unit
FEATURES
PRODUCT OVERVIEW
RoHS compliant
From an 9-36V or 18-75V input, UQQ’s deliver outputs
of 3.3V, 5V,12V,15V, or 24V. They employ an interleaved, synchronous-rectifier topology that exploits
100% of their duty cycle. They simultaneously achieve
ultra-high efficiency (to 90%), tight line/load regulation, low noise, and quick step response.
The UQQ’s feature set includes high isolation, input
pi filters, input undervoltage shutdown, output overvoltage protection, current limiting, short-circuit protection
and thermal shutdown. The standard footprint carries
on/off control (positive or negative polarity), output trim
(+10/–20%) and output sense functions.
A state of the art, single-board, open-frame
design with reduced component count, high efficiency,
low-on-resistance FET’s, and planar magnetics
embedded in heavy-copper pc boards all contribute to
impressive thermal derating.
All UQQ quarter-bricks are designed with full magnetic and optical isolation up to 2250 Volts DC (basic
insulation).
Standard quarter-brick package/pinout in
through-hole version
Low cost; Low profile, 0.43”(10.92mm)
9-36V or 18-75V wide range inputs
Output current: 4 to 25 Amps
Output voltages: 3.3, 5, 12, 15 or 24V
Interleaved synchronous-rectifier topology
Ultra high efficiency
No output reverse conduction
Outstanding thermal performance
On/off control, trim & sense functions
Fully isolated, up to 2250Vdc (48 VIN)
SIMPLIFIED SCHEMATIC
6/54
Output overvoltage protection
Fully I/O protected; Thermal shutdown
Designed to meet UL/EN/IEC60950-1 safety
approvals
3%.3%
6).
n6/54
RoHS hazardous substance compliant
n3%.3%
37)4#(
#/.42/,
n6).
/./&&
#/.42/,
07-
#/.42/,,%2
/04/
)3/,!4)/.
)NPUTUNDEROVERVOLTAGE
CURRENTSENSEOVER
TEMPERATURE#OMPARATORS
)3/,!4)/.
"!22)%2
2%&%2%.#%
%22/2!-0
42)-
Typical topology is shown.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 1 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Performance Specifications and Ordering Guide ~
PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE
Output
Input
R/N (mVp-p)
Load
VIN Nom.
(Volts)
Range
(Volts)
Min.
Typ.
Package
(Case/
Pinout)
±0.125%
12
9-36
180
7.81
86%
88%
C68,P32
±0.2%
48
18-75
80
2.01
86%
88%
C68,P32
Regulation
Root Model 5
VOUT
(V)
IOUT
(A)
Power
(Watts)
Typ.
Max.
Line
UQQ-3.3/25-Q12P-C
3.3
25
82.5
50
80
±0.05%
UQQ-3.3/25-Q48N-C
3.3
25
82.5
80
125
±0.05%
IIN, no load IIN, full load
(mA)
(A)
Efficiency
UQQ-5/17-Q12P-C
5
17
85
40
75
±0.05%
±0.06%
12
9-36
150
7.83
88.5%
90.5%
C68,P32
UQQ-5/20-Q48N-C
5
20
100
100
140
±0.05%
±0.165%
48
18-75
65
2.47
82.5%
84.5%
C68,P32
UQQ-12/8-Q12P-C
12
8
96
40
75
±0.05%
±0.05%
12
9-36
180
8.99
87%
89%
C68,P32
UQQ-12/8-Q48N-C
12
8
96
95
150
±0.05%
±0.1%
48
18-75
70
2.3
87.5%
89.5%
C68,P32
UQQ-15/7-Q12P-C
15
7
105
56
100
±0.05%
±0.1%
12
9-36
250
9.67
89%
90.5%
C68,P32
UQQ-24/4-Q12P-C
24
4
96
125
170
±0.05%
±0.075%
12
10-36
120
8.99
87.7
89%
C68,P32
1 Typical at TA = +25°C under nominal line voltage and full-load conditions. All models are
specified with an external 1μF multi-layer ceramic and 10μF capacitors across their output pins
and 100μF external input capacitor.
2 Ripple/Noise (R/N) measured over a 20MHz bandwidth.
3 Devices have no minimum-load requirements and will regulate under no-load conditions.
Regulation specifications describe the output voltage deviation as the line voltage or load is
varied from its nominal/midpoint value to either extreme. (Load step = 50%.)
4 Nominal line voltage, no load/full load condition.
5 Please refer to the Part Number Structure for additional part numbers and options.
PART NUMBER STRUCTURE
U QQ - 5 / 17 - Q12 N B 9 Lx - C
RoHS-6 hazardous substance compliant
(please include this designator for all models)
Output Configuration
Quarter-Brick Package
Pin Length Option
Blank = Std. pin length Alternate pin lengths
require quantity order.
L1 = 0.110 (2.79mm)
L2 = 0.145 (3.68mm)
Baseplate Pin 9 (special order):
Blank = No pin 9, standard
9 = Pin 9 installed, connects to baseplate
}
Nominal Output Voltage
Maximum Rated Output
Input Voltage Range
Q12 = 9-36V
Q48 = 18-75V
Remote On/Off Control Polarity:
Add "P" for positive polarity
Add "N" for negative polarity
Baseplate (optional):
Blank = no baseplate standard
B = baseplate installed, special order
Some model options may require minimum order quantities.
Note: Some model number combinations may not be available.
Contact Murata Power Solutions.
Pin 9 Baseplate Connection
The UQQ series may include an optional installed baseplate for extended
thermal management. This baseplate is electrically isolated from the rest of the
converter. Various UQQ models are also available with an additional pin 9 on
special quantity order which electrically connects to the baseplate. Pin 9 is also
isolated from the rest of the converter. Please refer to the mechanical drawings.
The baseplate may be ordered by adding a “B” to the model number tree
and pin 9 will be pre-installed by adding a “9”. The two options are separate.
Please refer to the Ordering Guide. Do not order pin 9 without the baseplate.
Note that “pin 9” converters may be on limited forecast, requiring minimum
order quantities and scheduled deliveries.
Pin 9 offers a positive method of controlling the electrical potential of the baseplate, independent of the converter. If you do not include pin 9, the baseplate
may also be grounded by the mounting bolts.
Please see page 9 for heatsink information.
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 2 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
MECHANICAL SPECIFICATIONS
56.4
2.22
4.76
.187
12.7
.50
0.25
.010
MIN
BOTTOM
CLEARANCE
23.6
.93
REF
36.8
1.45
END VIEW
WITH
BASEPLATE
CL
4X M3X0.5
THRU , .10" MAX
PENETRATION
(4 PLS)
47.24
1.860
10.9
.43
13.08
.515
REF
26.16
1.030
CL
TOP VIEW
OPTIONAL
BASEPLATE
'B' OPTION
END VIEW
WITHOUT
BASEPLATE
SIDE VIEW
INPUT/OUTPUT CONNECTIONS
Pin
Function P32
1
-Input
2
Remote On/Off*
3
+Input
4
-Output
5
-Sense
6
Output Trim
7
+Sense
8
+Output
9
Baseplate (optional)
* The Remote On/Off can be provided with
either positive ("P" suffix) or negative
("N" suffix) polarity.
Important! Always connect the sense pins;
see Application Notes.
50.80
2.000
1.02±0.05
.040±.002
AT PINS 1-3, 5-7, (9)
1.57±0.05
2X
.062±.002
AT PINS 4 & 8
25.4
1.00
REF
3.81
.150
3.81
.150
CL
18.42
.725
REF
CL
.071±.002 [1.80]
VENTED SHOULDER
.040 PIN
ON EACH
Third Angle Projection
7.62
.300
8
7
6
5
4
Dimensions are in inches (mm shown for ref. only).
3
2
9
CL
1
7.62
.300
BOTTOM VIEW
Optional pin #9
Connects to baseplate
And is electrically
isolated from converter
Tolerances (unless otherwise specified):
.XX ± 0.02 (0.5)
.XXX ± 0.010 (0.25)
Angles ± 2˚
Components are shown for reference only.
Soldering Guidelines
Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifications may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production
environment may differ; therefore please thoroughly review these guidelines with your process engineers.
Wave Solder Operations for through-hole mounted products (THMT)
For Sn/Ag/Cu based solders:
For Sn/Pb based solders:
Maximum Preheat Temperature
115° C.
Maximum Preheat Temperature
105° C.
Maximum Pot Temperature
270° C.
Maximum Pot Temperature
250° C.
Maximum Solder Dwell Time
7 seconds
Maximum Solder Dwell Time
6 seconds
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 3 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Performance and Functional Specifications
UQQ-3.3/25-Q12
UQQ-3.3/25-Q48
UQQ-5/17-Q12
UQQ-5/20-Q48
UQQ-12/8-Q12
17.50 Volts
16.75 Volts
None
15mAp-p
See ordering guide
9.0 Volts
8.0 Volts
37.5 Volts
75mAp-p
17.5 Volts
15.75 Volts (IOUT = ØA)
None
80mAp-p
9.0 Volts
8.0 Volts
37.5 Volts
75mAp-p
250mA
150mA
10.4 Amps
100mA
80mA
5.18 Amps
See ordering guide
0.1A2sec
100mA
150mA
10.44 Amps
50mA
65mA
6.24 Amps
250mA
180mA
12.12 Amps
8mA
2mA
8mA
5mA
5mA
LC
Yes (15)
Pi-type
NA
L-C
Yes (15)
L-C
Yes (15)
L-C
Yes (15)
INPUT
Input Voltage Range
Start-up Threshold
Undervoltage Shutdown
Overvoltage Shutdown
Reflected (back) ripple current (2)
Input Current
Full load conditions
Inrush transient
Output short circuit
No load
Low line (VIN = min.)
Standby mode
(Off, UV, OT shutdown)
Internal Input Filter Type
Reverse Polarity Protection
9.0 Volts
8.0 Volts
37.5 Volts
25mAp-p
Remote On/Off Control (5)
Positive logic (“P” suffix)
OFF = Ground pin to +0.8V max. ON = open or +3.5-15V max.
Negative logic (“N” suffix)
OFF = open or +5 to +VIN max. ON = Ground pin to +0.8V max. (16)
On/Off Current
1 mA
1 mA
1 mA
1mA
1 mA
–20 to +10% of VNOM
–20 to +10% of VNOM
OUTPUT
Voltage Output Range
See ordering guide
Voltage Output Accuracy
(50% load)
Adjustment Range
±1% of VNOM
±10% of VNOM
±10% of VNOM
±0.02% of
VOUT range/°C
Temperature Coefficient
Minimum Loading
Remote Sense Compensation
Ripple/noise (20MHz bandwidth)
Line/Load Regulation
Efficiency
Maximum Capacitive Loading
Low ESR <0.02Ω max., resistive load
Isolation Voltage
Input to Output
Input fo baseplate
Baseplate to output
Isolation resistance
Isolation capacitance
Isolation safety rating
Current limit inception
(98% of VOUT, after warmup)
Short Circuit Protection Method
Short Circuit Current
Short Circuit Duration
Overvoltage Protection
via magnetic feedback
–20 to +10% of VNOM
No minimum load
+10%
See ordering guide
10,000μF
4700μF
10,000μF
10,000μF
4700μF
2000 VDC min.
1500 VDC min.
1500 VDC min.
100MΩ
1500 pF
2250 VDC min.
1500 VDC min.
500 VDC min.
100MΩ
1000 pF
2000 VDC min.
1500 VDC min.
750 VDC min.
100MΩ
1000 pF
Basic insulation
2250 VDC min.
1500 VDC min.
1500 VDC min.
100MΩ
1500pF
2250 VDC min.
1500 VDC min.
750 VDC min.
100MΩ
1000 pF
30 Amps
29 Amps
20.5 Amps
27 Amps
9.5 Amps
5 Amps
Current limiting, hiccup autorestart. Remove overload for recovery.
5 Amps
3 Amps
0.5 Amps
Continuous, output shorted to ground (no damage)
0.5 Amps
4 Volts
3.96 Volts max.
14.4 Volts
www.murata-ps.com
6 Volts
6 Volts
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 4 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Performance and Functional Specifications (continued)
UQQ-12/8-Q48
UQQ-15/7-Q12
UQQ-24/4-Q12
INPUT
Input Voltage Range
Start-up Threshold
Undervoltage Shutdown
Overvoltage Shutdown
Reflected (back) ripple current (2)
Input Current
Full load conditions
Inrush transient
Output short circuit
No load
Low line (VIN = min.)
Standby mode
(Off, UV, OT shutdown)
Internal Input Filter Type
Reverse Polarity Protection
Remote On/Off Control (5)
Positive logic (“P” suffix)
Negative logic (“N” suffix)
17.5 Volts
16.0 Volts
None
15mAp-p
See ordering guide
9.0 Volts
8.0 Volts
38.5 Volts
50mAp-p
9.0 Volts
8.0 Volts
None
50mAp-p
100mA
70mA
5.93A
See ordering guide
0.1A2sec
250mA
250mA
12.9 Amps
250mA
120mA
10.73 Amps
2mA
5mA
5mA
PI-type
NA
L-C
Yes (15)
L-C
Yes (15)
OFF = Ground pin to +0.8V max. ON = open or +3.5-15V max.
OFF = open or +5 to +VIN max. ON = Ground pin to +0.8V max. (16)
On/Off Current
1 mA
OUTPUT
Voltage Output Range
See ordering guide
Voltage Output Accuracy
(50% load)
±1.25% of VNOM
±1% of VNOM
±1% of VNOM
Adjustment Range
–20 to +10% of VNOM
–20 to +10% of VNOM
±10% of VNOM
Temperature Coefficient
Minimum Loading
Remote Sense Compensation
Ripple/noise (20MHz bandwidth)
Line/Load Regulation
Efficiency
Maximum Capacitive Loading
Low ESR <0.02Ω max., resistive load
Isolation Voltage
Input to Output
Input fo baseplate
Baseplate to Output
Isolation resistance
Isolation capacitance
Isolation safety rating
Current limit inception
(98% of VOUT, after warmup)
Short Circuit Protection Method
Short Circuit Current
±0.02% of
VOUT range/°C
+10%
See ordering guide
2200μF
4700μF
1500μF max
2250 VDC min.
1500 VDC min.
500 VDC min.
100MΩ
1000 pF
2000 VDC min.
1500 VDC min.
1500 VDC min.
100MΩ
1000 pF
Basic insulation
2000 VDC min.
1500 VDC min.
1500 VDC min.
100MΩ
1000 pF
12 Amps
9.5 Amps
5.75 Amps
Current limiting, hiccup autorestart. Remove overload for recovery
0.1 Amps
0.5 Amps
0.5 Amps
Short Circuit Duration
Overvoltage Protection
via magnetic feedback
No minimum loading
+10%
+10%
Continuous, output shorted to ground (no damage)
15 Volts
18 Volts
www.murata-ps.com
29 Volts
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 5 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
UQQ-3.3/25-Q12 UQQ-3.3/25-Q48 UQQ-5/17-Q12
UQQ-5/20-Q48
UQQ-12/8-Q12
50μsec to ±1%
of final value
100μsec to ±1%
of final value
50μsec to ±1%
of final value
VIN to VOUT regulated
10msec
10msec max
Remote On/Off
to VOUT regulated
5msec
5msec max
Switching frequency
255 ±25kHz
255 ±25kHz
UQQ-12/8-Q48
UQQ-15/7-Q12
UQQ-24/4-Q12
95μsec to ±1%
of final value
50μsec to ±1%
of final value
50μsec to ±2%
of final value
20msec
10msec
10msec
245 ±20kHz
260 ±25kHz
260 ±25kHz
–40 to +100°C
–40 to +105°C
–40 to +105°C
DYNAMIC CHARACTERISTICS
Dynamic Load Response
(50-75-50% load step)
Start-up Time
10msec
25msec
10msec
5msec
260 ±25kHz
225-265kHz
260 ±25kHz
ENVIRONMENTAL
Calculated MTBF (4)
TBC
Operating Temperature Range
See Derating curves
Operating Temperature Range
with baseplate
(no Derating required) (3)(14)
–40 to +85ºC
with Derating
–40 to +105ºC
–40 to +100ºC
–40 to +105°C
Storage Temperature Range
–40 to +105ºC
–40 to +105°C
–55 to +125ºC
Thermal Protection/Shutdown
+120ºC, measured at thermistor T1
Relative humidity
To +85°C/85% non-condensing
PHYSICAL
Outline dimensions
See mechanical specifications
Baseplate material
Aluminum
Pin material
Copper alloy
Pin diameter
0.04/0.062 inches, 1.016/1.524 mm
Weight
Electromagnetic interference
(conducted, external filter
required)
Safety
1 ounce (28 grams)
Designed to meet FCC part 15, class B, EN55022
Designed to meet UL/cUL 60950-1, CSA-C22.2 No.60950-1, IEC/EN 60950-1
Flammability
UL 94V-0
Specification Notes:
(1) All models are tested and specified with 300 lfm airflow, external 1 and 10μF paralleled ceramic/
tantalum output capacitors and a 100μF external input capacitor. All capacitors are low ESR
types. These capacitors are necessary to accommodate our test equipment and may not be
required in your applications. All models are stable and regulate within spec under no-load
conditions.
General conditions for Specifications are +25°C, VIN = nominal, VOUT = nominal, full load unless
noted.
(2) Input Ripple Current is tested and specified over a 5Hz to 20MHz bandwidth. Input filtering is
CIN = 33μF tantalum, CBUS = 220μF electrolytic, LBUS = 12μH.
(3) Note that Maximum Power Derating curves indicate an average current at nominal input voltage.
At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current
outputs if the total RMS current over time does not exceed the Derating curve. All Derating
curves are presented at sea level altitude. Be aware of reduced power dissipation with increasing altitude.
(4) Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3,
ground fixed conditions, TPCBOARD = +25°C, full output load, natural air convection.
(5) The On/Off Control may be driven with external logic or by applying appropriate external voltages
which are referenced to Input Common. The On/Off Control Input should use either an open
collector/open drain transistor or logic gate.
(6) Short circuit shutdown begins when the output voltage degrades approximately 2% from the
selected setting.
(7) The outputs are not intended to sink appreciable reverse current.
www.murata-ps.com
(8) Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise
Reduction.
(9) All models are fully operational and meet published specifications, including “cold start” at –40°C.
On-board component package temperatures must not exceed +128°C.
(10) Regulation specifications describe the deviation as the line input voltage or output load current is
varied from a nominal midpoint value to either extreme.
(11) Alternate pin length and/or other output voltages are available under special quantity order.
(12) Overvoltage shutdown on 48V input models can be eliminated under special quantity order. OV
shutdown can be deleted in order to comply with certain telecom reliability requirements. These
requirements attempt continued operation despite significant input overvoltage.
(13) Do not exceed maximum power specifications when adjusting the output trim.
(14) Note that the converter may operate up to +105°C with the baseplate installed (+100°C for the
UQQ-3.3/25-Q48). However, thermal self-protection occurs near +120°C Therefore, +105°C is
recommended to avoid thermal shutdown.
(15) If reverse polarity is accidentally applied to the input, to ensure reverse input protection, always
connect an external input fuse in series with the +VIN input. Use approximately twice the full
input current rating with nominal input voltage.
(16) For On/Off Control on negative-polarity UQQ-3.3/25-Q48N models, the maximum OFF mode
control voltage is +13.5 Volts. For the ON mode, the range is pin grounded to +1 Volt max.
(17) Always connect the sense pins. If they are not connected to a remote load, connect each sense
pin to its respective output at the converter pins.
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 6 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Absolute Maximum Ratings
Input Voltage
Continuous
Transient (100msec)
12V models
0 to +36V
+50V
48V models
0 to +75V
+100V
On/Off Control
0V min to +13.5V max.
Input Reverse Polarity Protection
See Fuse section
Output Overvoltage
VOUT +20% max.
Output Current (7)
Current-limited. Devices can
withstand sustained short circuit
without damage.
Storage Temperature
–55 to +125°C
Lead Temperature
See soldering guidelines
Absolute maximums are stress ratings. Exposure of devices to greater than any of
these conditions may adversely affect long-term reliability. Proper operation under
conditions other than those listed in the Performance/Functional Specifications
Table is not implied nor recommended.
Technical Notes
Removal of Soldered UQQ’s from Printed Circuit Boards
They should be selected for bulk capacitance (at appropriate frequencies),
low ESR, and high rms-ripple-current ratings. The switching nature of
DC/DC converters requires that dc voltage sources have low ac impedance as
highly inductive source impedance can affect system stability. In Figure 2,
CBUS and LBUS simulate a typical dc voltage bus. Your specific system configuration may necessitate additional considerations.
In critical applications, output ripple/noise (also referred to as periodic
and random deviations or PARD) can be reduced below specified limits
using filtering techniques, the simplest of which is the installation of
additional external output capacitors. Output capacitors function as true
filter elements and should be selected for bulk capacitance, low ESR, and
appropriate frequency response. In Figure 3, the two copper strips simulate
real-world pcb impedances between the power supply and its load. Scope
measurements should be made using BNC connectors or the probe ground
should be less than ½ inch and soldered directly to the fixture.
All external capacitors should have appropriate voltage ratings and be
located as close to the converter as possible. Temperature variations for all
relevant parameters should be taken into consideration. OS-CONTM organic
semiconductor capacitors (www.sanyo.com) can be especially effective for
further reduction of ripple/noise. The most effective combination of external
I/O capacitors will be a function of line voltage and source impedance, as
well as particular load and layout conditions.
Should removal of the UQQ from its soldered connection be needed, thoroughly de-solder the pins using solder wicks or de-soldering tools. At no time
should any prying or leverage be used to remove boards that have not been
properly de-soldered first.
+SENSE
Input Source Impedance
+OUTPUT
UQQ converters must be driven from a low ac-impedance input source. The
DC/DC’s performance and stability can be compromised by the use of highly
inductive source impedances. The input circuit shown in Figure 2 is a practical
solution that can be used to minimize the effects of inductance in the input
traces. For optimum performance, components should be mounted close to the
DC/DC converter.
I/O Filtering, Input Ripple Current, and Output Noise
All models in the UQQ Series are tested/specified for input ripple current (also
called input reflected ripple current) and output noise using the circuits and
layout shown in Figures 2 and 3. External input capacitors (CIN in Figure 2)
serve primarily as energy-storage elements.
TO
OSCILLOSCOPE
3
COPPER STRIP
8
C1
C2
SCOPE
RLOAD
4
–OUTPUT
5
–SENSE
COPPER STRIP
C1 = 1μF CERAMIC
C2 = 10μF TANTALUM
LOAD 2-3 INCHES (51-76mm) FROM MODULE
Figure 3. Measuring Output Ripple/Noise (PARD)
+INPUT
LBUS
+
VIN
CURRENT
PROBE
7
CBUS
CIN
–
1
–INPUT
CIN = 33μF, ESR < 700m7 @ 100kHz
CBUS = 220μF, ESR < 100m7 @ 100kHz
LBUS = 12μH
Figure 2. Measuring Input Ripple Current
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 7 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Start-Up Threshold and Undervoltage Shutdown
Under normal start-up conditions, the UQQ Series will not begin to regulate
properly until the ramping input voltage exceeds the Start-Up Threshold.
Once operating, devices will turn off when the applied voltage drops below
the Undervoltage Shutdown point. Devices will remain off as long as the
undervoltage condition continues. Units will automatically re-start when
the applied voltage is brought back above the Start-Up Threshold. The
hysteresis built into this function avoids an indeterminate on/off condition
at a single input voltage. See Performance/Functional Specifications table for
actual limits.
should not be allowed to exceed 0.5V. Consider using heavier wire if this
drop is excessive.
Sense is connected at the load and corrects for resistive errors only. Be
careful where it is connected. Any long, distributed wiring and/or significant
inductance introduced into the Sense control loop can adversely affect
overall system stability. If in doubt, test the application, and observe the
DC/DC’s output transient response during step loads. There should be no
appreciable ringing or oscillation. You may also adjust the output trim slightly
to compensate for voltage loss in any external filter elements. Do not exceed
maximum power ratings.
Start-Up Time
Current Limiting
The VIN to VOUT Start-Up Time is the interval between the point at which
a ramping input voltage crosses the Start-Up Threshold voltage and the
point at which the fully loaded output voltage enters and remains within its
specified accuracy band. Actual measured times will vary with input source
impedance, external input capacitance, and the slew rate and final value of
the input voltage as it appears to the converter. The On/Off to VOUT start-up
time assumes that the converter is turned off via the Remote On/Off Control
with the nominal input voltage already applied.
When power demands from the output falls within the current limit inception range for the rated output current, the DC/DC converter will go into
a current limiting mode. In this condition the output voltage will decrease
proportionately with increases in output current, thereby maintaining a
somewhat constant power dissipation. This is commonly referred to as
power limiting. Current limit inception is defined as the point where the fullpower output voltage falls below the specified tolerance. If the load current
being drawn from the converter is significant enough, the unit will go into a
short circuit condition. See “Short Circuit Condition.”
On/Off Control
The primary-side, Remote On/Off Control function (pin 2) can be specified
to operate with either positive or negative polarity. Positive-polarity devices
("P" suffix) are enabled when pin 2 is left open or is pulled high. Positivepolarity devices are disabled when pin 2 is pulled low (with respect to
–Input). Negative-polarity devices are off when pin 2 is high and on when
pin 2 is pulled low. See Figure 4
Dynamic control of the remote on/off function is best accomplished with
a mechanical relay or an open-collector/open-drain drive circuit (optically
isolated if appropriate). The drive circuit should be able to sink appropriate
current (see Performance Specifications) when activated and withstand
appropriate voltage when deactivated.
).054
%15)6!,%.4#)2#5)4&/2
0/3)4)6%!.$.%'!4)6%
,/')#-/$%,3
6
/./&&
#/.42/,
#/.42/,
n).054
When a converter is in current limit mode the output voltages will drop as
the output current demand increases. If the output voltage drops too low,
the magnetically coupled voltage used to develop primary side voltages will
also drop, thereby shutting down the PWM controller. Following a time-out
period of about 50 milliseconds, the PWM will restart, causing the output voltages to begin ramping to their appropriate values. If the short-circuit condition persists, another shutdown cycle will be initiated. This on/off cycling
is referred to as “hiccup” mode. The hiccup cycling reduces the average
output current, thereby preventing internal temperatures from rising to
excessive levels. The UQQ is capable of enduring an indefinite short circuit
output condition.
Thermal Shutdown
UQQ converters are equipped with thermal-shutdown circuitry. If the internal temperature of the DC/DC converter rises above the designed operating
temperature (See Performance Specifications), a precision temperature
sensor will power down the unit. When the internal temperature decreases
below the threshold of the temperature sensor, the unit will self start.
Output Overvoltage Protection
2%&
Short Circuit Condition
#/--/.
Figure 4. Driving the Remote On/Off Control Pin
Sense Input
Note: The sense and VOUT lines are internally connected through low-value
resistors. Nevertheless, if sense is not used for remote regulation, the user
must connect + sense to + VOUT and -sense to -VOUT at the converter pins.
Sense is intended to correct small output accuracy errors caused by the
resistive ohmic drop in output wiring as output current increases. This output
drop (the difference between Sense and VOUT when measured at the converter)
www.murata-ps.com
The output voltage is monitored for an overvoltage condition via magnetic
coupling to the primary side. If the output voltage rises to a fault condition,
which could be damaging to the load circuitry (see Performance Specifications), the sensing circuitry will power down the PWM controller causing
the output voltage to decrease. Following a time-out period the PWM will
restart, causing the output voltage to ramp to its appropriate value. If the
fault condition persists, and the output voltages again climb to excessive
levels, the overvoltage circuitry will initiate another shutdown cycle. This
on/off cycling is referred to as “hiccup” mode.
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 8 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Input Reverse-Polarity Protection
1
If the input-voltage polarity is accidentally reversed, an internal diode will
become forward biased and likely draw excessive current from the power
source. If the source is not current limited or the circuit appropriately fused, it
could cause permanent damage to the converter.
+OUTPUT
–INPUT
+SENSE
2
ON/OFF
CONTROL
TRIM
–SENSE
3
7
6
LOAD
RTRIM UP
Input Fusing
Certain applications and/or safety agencies may require the installation of
fuses at the inputs of power conversion components. Fuses should also be
used if the possibility of a sustained, non-current-limited, input-voltage polarity
reversal exists. For MPS UQQ Series DC/DC Converters, slow-blow fuses are
recommended with values no greater than twice the maximum input current.
8
+INPUT
–OUTPUT
5
4
Figure 5. Trim Connections To Increase Output Voltages Using Fixed Resistors
Trimming Output Voltage
UQQ converters have a trim capability (pin 6) that enables users to adjust the
output voltage from +10% to –20% (refer to the trim equations). Adjustments
to the output voltage can be accomplished with a single fixed resistor as shown
in Figures 5 and 6. A single fixed resistor can increase or decrease the output
voltage depending on its connection. Resistors should be located close to
the converter and have TCR’s less than 100ppm/°C to minimize sensitivity to
changes in temperature. If the trim function is not used, leave the trim pin open.
Standard UQQ’s have a "positive trim" where a single resistor connected from
the Trim pin (pin 6) to the +Sense (pin 7) will increase the output voltage. A
resistor connected from the Trim Pin (pin 6) to the –Sense (pin 5) will decrease
the output voltage.
Trim adjustments greater than the specified +10%/–20% can have an adverse
affect on the converter’s performance and are not recommended. Excessive
voltage differences between VOUT and Sense, in conjunction with trim adjustment of the output voltage, can cause the overvoltage protection circuitry to
activate (see Performance Specifications for overvoltage limits).
Temperature/power derating is based on maximum output current and voltage
at the converter’s output pins. Use of the trim and sense functions can cause
output voltages to increase, thereby increasing output power beyond the UQQ’s
specified rating, or cause output voltages to climb into the output overvoltage
region. Therefore:
1
+SENSE
2
ON/OFF
CONTROL
TRIM
3
8
7
6
LOAD
RTRIM DOWN
–SENSE
+INPUT
–OUTPUT
5
4
Figure 6. Trim Connections To Decrease Output Voltages Using Fixed Resistors
Trim Up
Trim Down
UQQ-3.3/25-Q12, UQQ-3.3/25-Q48
RT UP (k7) =
13.3(VO – 1.226)
–10.2
VO – 3.3
RTDOWN (k7) =
16.31
3.3 – VO
–10.2
UQQ-5/17-Q12, UQQ-5/20-Q48
RT UP (k7) =
(VOUT at pins) x (IOUT) ≤ rated output power
The Trim pin (pin 6) is a relatively high impedance node that can be susceptible
to noise pickup when connected to long conductors in noisy environments. In
such cases, a 0.22μF capacitor to –Output can be added to reduce this long
lead effect.
+OUTPUT
–INPUT
20.4(VO – 1.226)
–10.2
VO – 5
RTDOWN (k7) =
25.01
5 – VO
–10.2
UQQ-12/8-Q12, UQQ-12/8-Q48
RT UP (k7) =
49.6(VO – 1.226)
–10.2
VO – 12
RTDOWN (k7) =
60.45
12 – VO
–10.2
UQQ-15/7-Q12
RT UP (k7) =
62.9(VO – 1.226)
–10.2
VO – 15
RTDOWN (k7) =
76.56
15 – VO
–10.2
UQQ-24/4-Q12
RT UP (k7) =
www.murata-ps.com
101 × (VO – 1.226)
VO – 24
–10.2
RTDOWN (k7) =
124.2
24 – VO
–10.2
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 9 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
UQQ Series Aluminum Heatsink
Thermal Performance
Please note – The UQQ series shares the same heatsink kits as the UVQ
series. Therefore, when ordering these heat sinks, use the model numbers
below which end with the ‘UVQ’ suffix. The UQQ series converter baseplate
can be attached either to an enclosure wall or a heatsink to remove heat from
internal power dissipation. The discussion below concerns only the heatsink
alternative. The UQQ’s are available with a low-profile extruded aluminum
heatsink kit, models HS-QB25-UVQ, HS-QB50-UVQ, and HS-QB100-UVQ.
This kit includes the heatsink, thermal mounting pad, screws and mounting
hardware. See the assembly diagram below. Do not overtighten the screws in
the tapped holes in the converter. This kit adds excellent thermal performance
without sacrificing too much component height. See the Mechanical Outline
Drawings for assembled dimensions. If the thermal pad is firmly attached, no
thermal compound (“thermal grease”) is required.
The HS-QB25-UVQ heatsink has a thermal resistance of 12 degrees Celsius
per Watt of internal heat dissipation with “natural convection” airflow (no
fans or other mechanical airflow) at sea level altitude. This thermal resistance
assumes that the heatsink is firmly attached using the supplied thermal pad
and that there is no nearby wall or enclosure surface to inhibit the airflow. The
thermal pad adds a negligible series resistance of approximately 0.5°C/Watt so
that the total assembled resistance is 12.5°C/Watt.
When assembling these kits onto the converter, include ALL kit hardware to
assure adequate mechanical capture and proper clearances. Thread relief is
0.090" (2.3mm).
Be aware that we need to handle only the internal heat dissipation, not the full
power output of the converter. This internal heat dissipation is related to the
efficiency as follows:
Power Dissipation [Pd] = Power In – Power Out [1]
Power Out / Power In = Efficiency [in %] / 100 [2]
Power Dissipation [Pd] = Power In x (1 –Efficiency%/100) [3]
Power Dissipation [Pd] = Power Out x (1 / (Efficiency%/100) - 1) [4]
Efficiency of course varies with input voltage and the total output power. Please
refer to the Performance Curves.
0!.(%!$3#2%7
-8-0,#3
Since many applications do include fans, here is an approximate equation to
calculate the net thermal resistance:
RΘ [at airflow] = RΘ [natural convection] / (1 + (Airflow in LFM) x
[Airflow Constant]) [5]
,/#+7!3(%2
-
0,#3
&,!47!3(%2
./
0,#3
(%!43).+
(%!442!.3&%20!$
0EELOFFWHITEPLASTIC
BACKINGMATERIALBEFORE
ATTACHINGTOHEATSINK
Figure 7. Model UQQ Heatsink Assembly Diagram
www.murata-ps.com
Where,
RΘ [at airflow] is the net thermal resistance (in °C/W) with the amount of
airflow available and,
RΘ [natural convection] is the still air total path thermal resistance or in this
case 12.5°C/Watt and,
“Airflow in LFM” is the net air movement flow rate immediately at the converter.
This equation simplifies an otherwise complex aerodynamic model but is a
useful starting point. The “Airflow Constant” is dependent on the fan and enclosure geometry. For example, if 200 LFM of airflow reduces the effective natural
convection thermal resistance by one half, the airflow constant would be
0.005. There is no practical way to publish a “one size fits all” airflow constant
because of variations in airflow direction, heatsink orientation, adjacent walls,
enclosure geometry, etc. Each application must be determined empirically and
the equation is primarily a way to help understand the cooling arithmetic.
This equation basically says that small amounts of forced airflow are quite
effective removing the heat. But very high airflows give diminishing returns.
Conversely, no forced airflow causes considerable heat buildup. At zero airflow,
cooling occurs only because of natural convection over the heatsink. Natural
convection is often well below 50 LFM, not much of a breeze.
While these equations are useful as a conceptual aid, most users find it very
difficult to measure actual airflow rates at the converter. Even if you know
the velocity specifications of the fan, this does not usually relate directly to
the enclosure geometry. Be sure to use a considerable safety margin doing
thermal analysis. If in doubt, measure the actual heat sink temperature with
a calibrated thermocouple, RTD or thermistor. Safe operation should keep the
heat sink below 100°C.
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 10 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Calculating Maximum Power Dissipation
Heat Sink Example
To determine the maximum amount of internal power dissipation, find the
ambient temperature inside the enclosure and the airflow (in Linear Feet per
Minute – LFM) at the converter. Determine the expected heat dissipation using
the Efficiency curves and the converter Input Voltage. You should also compensate for lower atmospheric pressure if your application altitude is considerably
above sea level.
Assume an efficiency of 92% and power output of 100 Watts. Using equation
[4], Pd is about 8.7 Watts at an input voltage of 48 Volts. Using +30°C ambient
temperature inside the enclosure, we wish to limit the heat sink temperature to
+90°C maximum baseplate temperature to stay well away from thermal shutdown. The +90°C. figure also allows some margin in case the ambient climbs
above +30°C or the input voltage varies, giving us less than 92% efficiency.
The heat sink and airflow combination must have the following characteristics:
The general proceedure is to compute the expected temperature rise of the
heatsink. If the heatsink exceeds +100°C. either increase the airflow and/or
reduce the power output. Start with this equation:
Internal Heat Dissipation [Pd in Watts] = (Ts – Ta)/RΘ [at airflow] [6]
where “Ta” is the enclosure ambient air temperature and,
where “Ts” is the heatsink temperature and,
where “RΘ [at airflow]” is a specific heat transfer thermal resistance (in
degrees Celsius per Watt) for a particular heat sink at a set airflow rate. We
have already estimated RΘ [at airflow] in the equations above.
Note particularly that Ta is the air temperature inside the enclosure at the
heatsink, not the outside air temperature. Most enclosures have higher
internal temperatures, especially if the converter is “downwind” from other
heat-producing circuits. Note also that this “Pd” term is only the internal heat
dissipated inside the converter and not the total power output of the converter.
We can rearrange this equation to give an estimated temperature rise of the
heatsink as follows:
8.7 W = (90-30) / RΘ[airflow] or,
RΘ[airflow] = 60/8.7 = 6.9°C/W
Since the ambient thermal resistance of the heatsink and pad is 12.5°C/W, we
need additional forced cooling to get us down to 6.9°C/W. Using a hypothetical
airflow constant of 0.005, we can rearrange equation [5] as follows:
(Required Airflow, LFM) x (Airflow Constant) = RΘ[Nat.Convection] /
RΘ[at airflow] –1, or,
(Required Airflow, LFM) x (Airflow Constant) = 12.5/6.9 –1 = 0.81
and, rearranging again,
(Required Airflow, LFM) = 0.81/0.005 = 162 LFM
162 LFM is the minumum airflow to keep the heatsink below +90°C. Increase
the airflow to several hundred LFM to reduce the heatsink temperature further
and improve life and reliability.
Ts = (Pd x RΘ [at airflow]) + Ta [7]
Heatsink Kit *
Model Number
Still Air (Natural convection)
thermal resistance
Heatsink height
(see drawing)
HS-QB25-UVQ
12°C/Watt
0.25" (6.35mm)
HS-QB50-UVQ
10.6°C/Watt
0.50" (12.7mm)
HS-QB100-UVQ
8°C/Watt
1.00" (25.4mm)
2.28
(57.91)
1.860
(47.24)
* Kit includes heatsink, thermal pad and mounting hardware.
1.03
1.45
(26.16) (36.83)
These model numbers are correct for the UQQ series.
0.140 DIA. (3.56) (4 PLACES)
*
MATERIAL: BLACK ANODIZED ALUMINUM
0.10
(2.54)
* UQQ SERIES HEATSINKS ARE AVAILABLE IN 3 HEIGHTS:
0.25 (6.35), 0.50 (12.70) AND 1.00 (25.4)
Dimensions in inches (mm)
Optional Heatsink
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 11 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Typical Performance Curves
UQQ-3.3/25-Q12
Efficiency vs. Line Voltage and Load Current @ 25°C
UQQ-3.3/25-Q48P
Efficiency vs. Line Voltage and Load Current @ 25ºC
90
90
88
88
86
84
84
VIN = 12V
82
VIN = 18V
80
VIN = 24V
82
Efficiency (%)
Efficiency (%)
86
VIN = 18V
80
VIN = 24V
78
VIN = 36V
76
74
VIN = 48V
72
VIN = 30V
78
VIN = 60V
70
VIN = 36V
VIN = 72V
68
76
66
74
64
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
2
4
6
8
10
Load Current (Amps)
12
14
16
18
20
22
24
26
Load Current (Amps)
UQQ-3.3/25-Q12P Maximum Current Temperature Derating
(no baseplate, VIN = 12V, air flow is transverse)
UQQ-3.3/25-Q12PB Maximum Current Temperature Derating
(with baseplate, VIN = 12V, air flow is transverse)
25
25.0
24.5
24.5
Natural Convection
Natural Convection
Output Current (Amps)
Output Current (Amps)
24
23.5
23
22.5
22
100 lfm
21.5
21
200 lfm
20.5
20
300 lfm
19.5
24.0
100 lfm
23.5
23.0
22.5
200 lfm
22.0
21.5
300 lfm
21.0
19
20.5
18.5
400 lfm
20.0
18
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (°C)
20
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (°C)
UQQ-3.3/25-Q48 Maximum Current Temperature Derating at sea level
(VIN = 48V, with baseplate, transverse air flow)
26
25
Output Current (Amps)
24
23
22
21
20
19
18
Natural Convection
100 LFM
17
200 LFM
300 LFM
16
15
400 LFM
14
13
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Ambient Temperature (°C)
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 12 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Typical Performance Curves
51110
%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —#
51110
0OWER$ISSIPATIONVS,OAD#URRENT —#
0OWER$ISSIPATION7ATTS
%FFICIENCY
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
,OAD#URRENT!MPS
UQQ-5/17-Q12P Maximum Current Temperature Derating
No baseplate, VIN = 12V (transverse air flow at sea level)
75
80
UQQ-5/17-Q12P Maximum Current Temperature Derating
With baseplate, VIN = 12V (transverse air flow at sea level)
17
17
16
16
400 lfm
Output Current (Amps)
Output Current (Amps)
,OAD#URRENT!MPS
300 lfm
15
14
Natural Convection
13
100 lfm
12
25
35
30
45
40
50
Natural Convection
14
100 lfm
200 lfm
13
300 lfm
12
200 lfm
11
–40
15
55
65
60
70
75
80
400 lfm
11
–40
85
25
30
35
Ambient Temperature (°C)
70
65
60
55
50
45
40
85
Ambient Temperature (°C)
UQQ-5/20-Q48P
Efficiency vs. Line Voltage and Load Current @ 25°C
UQQ-5/20-Q48 Maximum Current Temperature Derating at sea level
(VIN = 48V, with baseplate, transverse airflow)
20
90
Output Current (Amps)
19
85
Efficiency (%)
VIN = 75V
VIN = 60V
80
VIN = 48V
VIN = 36V
75
70
18
17
16
15
Natural Convection
100 lfm
200 lfm
300 lfm
14
VIN = 24V
13
VIN = 18V
12
400 lfm
11
20
65
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Ambient Temperature (°C)
Load Current (Amps)
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 13 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Typical Performance Curves
51110
%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT
5111
0OWER$ISSIPATIONVS,OAD#URRENT
—#
0OWER$ISSIPATION7ATTS
%FFICIENCY
—#
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
,OAD#URRENT!MPS
8.0
7.5
7.5
7.0
Output Current (Amps)
Output Current (Amps)
8.0
6.5
6.0
100 lfm
5.0
200 lfm
Natural Convection
7.0
6.5
6.0
Natural Convection
5.5
100 lfm
200 lfm
5.0
300 lfm
4.5
UQQ-12/8-Q12P Maximum Current Temperature Derating
With baseplate, VIN = 12V (transverse air flow at sea level)
UQQ-12/8-Q12P Maximum Current Temperature Derating
(no baseplate, VIN = 12V, air flow is transverse)
5.5
,OAD#URRENT!MPS
300 lfm
400 lfm
4.5
400 lfm
4.0
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
4.0
–40
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (°C)
Ambient Temperature (°C)
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 14 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Typical Performance Curves
UQQ-12/8-Q48P Maximum Current Temperature Derating
(With baseplate, VIN = 48V transverse air flow at sea level)
UQQ-12/8-Q48P
Efficiency vs. Line Voltage and Load Current @ 25°C
92
8
90
7.5
Output Current (Amps)
88
Efficiency (%)
86
84
VIN = 18V
82
VIN = 36V
80
VIN = 48V
6.5
6
100 lfm
5.5
200 lfm
300 lfm
5
VIN = 75V
78
7
400 lfm
4.5
76
Natural Convection
4
74
1
2
3
4
5
6
7
8
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Ambient Temperature (°C)
Load Current (Amps)
UQQ-12/8-Q48P Maximum Current Temperature Derating
(With baseplate, VIN = 24V, transverse air flow at sea level)
8
Output Current (Amps)
7.5
7
6.5
100 lfm
6
200 lfm
300 lfm
5.5
400 lfm
5
Natural Convection
4.5
4
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Ambient Temperature (°C)
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 15 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Typical Performance Curves
51110
%FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —#
51110
0OWER$ISSIPATIONVS,OAD#URRENT —#
0OWER$ISSIPATION7ATTS
%FFICIENCY
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
6).6
,OAD#URRENT!MPS
,OAD#URRENT!MPS
UQQ-15/7-Q12P Maximum Current Temperature Derating
With baseplate, VIN = 12V (transverse air flow at sea level)
7
400 lfm
6.5
Output Current (Amps)
300 lfm
6
5.5
5
4.5
Natural Convection
100 lfm
200 lfm
4
3.5
–40
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (°C)
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 16 of 17
UQQ Series
Wide Input Range Single Output DC/DC Converters
Typical Performance Curves
UQQ-24/4-Q12P
Efficiency vs. Line Voltage and Load Current @ 25°C
UQQ-24/4-Q12P
Power Dissipation vs. Load Current @ 25°C
93
14
VIN = 36V
13
92
VIN = 12V
90
89
VIN = 24V
88
VIN = 30V
VIN = 24V
11
Power Dissipation (Watts)
VIN = 10V
91
Efficiency (%)
VIN = 30V
12
VIN = 12V
10
VIN = 10V
9
8
7
6
5
4
87
VIN = 36V
3
86
1
2
3
2
4
2
1
Load Current (Amps)
3
4
Load Current (Amps)
UQQ-24/4-Q12P Maximum Current Temperature Derating
No baseplate, VIN = 12V (transverse air flow at sea level)
UQQ-24/4-Q12P Maximum Current Temperature Derating
With baseplate, VIN = 12V (transverse air flow at sea level)
4
4
3.8
3.8
400 lfm
400 lfm
300 lfm
3.6
Output Current (Amps)
Output Current (Amps)
3.6
3.4
3.2
300 lfm
3
2.8
2.6
3.4
3.2
3
Natural Convection
2.8
2.6
100 lfm
Natural Convection
2.4
2.4
100 lfm
2.2
200 lfm
2.2
200 lfm
2
2
20
25
30
35
40
45
50
55
60
65
70
75
80
85
20
Ambient Temperature (°C)
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (°C)
USA:
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: [email protected] ISO 9001 and 14001 REGISTERED
12/15/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740-1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany:
München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Singapore:
Parkway Centre, Tel: +65 6348 9096, email: [email protected]
Technical enquiries email: [email protected], tel: +1 508 339 3000
MDC_UQQ.A10 Page 17 of 17