VISHAY SF1600-TAP

SF1200, SF1600
www.vishay.com
Vishay Semiconductors
Ultrafast Avalanche Sinterglass Diode
FEATURES
• Very low switching losses
• Glass passivated
• High reverse voltage
• Hermetically
envelope
sealed
axial-leaded
glass
• Material categorization:
For definitions of compliance please see
www.vishay.com/doc?99912
949539
APPLICATIONS
MECHANICAL DATA
• Switched mode power supplies
Case: SOD-57
• High-frequency inverter circuits
Terminals: plated axial leads, solderable per MIL-STD-750,
method 2026



Polarity: color band denotes cathode end
Mounting position: any
Weight: approx. 369 mg
ORDERING INFORMATION (Example)
DEVICE NAME
ORDERING CODE
TAPED UNITS
SF1600
SF1600-TR
5000 per 10" tape and reel
MINIMUM ORDER QUANTITY
25 000
SF1600
SF1600-TAP
5000 per ammopack
25 000
PARTS TABLE
PART
TYPE DIFFERENTIATION
PACKAGE
SF1200
VR = 1200 V; IF(AV) = 1 A
SOD-57
SF1600
VR = 1600 V; IF(AV) = 1 A
SOD-57
ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
Reverse voltage = repetitive peak
reverse voltage
TEST CONDITION
See electrical characteristics
PART
SYMBOL
VALUE
UNIT
SF1200
VR = VRRM
1200
V
SF1600
VR = VRRM
1600
V
Peak forward surge current
tp = 10 ms, half sine wave
IFSM
30
A
Average forward current
Half sine wave, VR = VRRM,
RthJA = 45 K/W
IF(AV)
1
A
I(BR)R = 400 mA, inductive load
ER
10
mJ
Tj = Tstg
- 55 to + 175
°C
Max. pulse energy in avalanche
mode, non repetitive (inductive load
switch off
Junction and storage temperature
range
MAXIMUM THERMAL RESISTANCE (Tamb = 25 °C, unless otherwise specified)
PARAMETER
Junction ambient
Rev. 1.8, 11-Sep-12
TEST CONDITION
SYMBOL
VALUE
UNIT
Lead length l = 10 mm, TL = constant
RthJA
45
K/W
Document Number: 86059
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
SF1200, SF1600
www.vishay.com
Vishay Semiconductors
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
TEST CONDITION
SYMBOL
MIN.
TYP.
MAX.
UNIT
IF = 1 A
VF
-
-
3.4
V
VR = VRRM
IR
-
-
5
μA
VR = VRRM, Tj = 125 °C
IR
-
-
50
μA
SF1200
V(BR)R
1250
-
-
V
SF1600
V(BR)R
1650
-
-
V
trr
-
-
75
ns
Forward voltage
Reverse current
lR = 100 μA
Reverse breakdown voltage
PART
IF = 0.5 A, IR = 1 A, iR = 0.25 A
Reverse recovery time
TYPICAL
CHARACTERISTICS (Tamb = 25 C, unless otherwise specified)

100
1000
10
IR - Reverse Current (μA)
IF - Forward Current (A)
VR = VRRM
Tj = 175 °C
1
Tj = 25 °C
0.1
0.01
1
2
3
4
5
6
7
8
VF - Forward Voltage (V)
16463
Fig. 1 - Forward Current vs. Forward Voltage
VR = VRRM
half sine wave
1.0
0.8
RthJA = 45 K/W
l = 10 mm
0.6
0.4
RthJA = 100 K/W
PCB: d = 25 mm
0.2
0.0
0
20
40
60
80 100 120 140 160 180
Tamb - Ambient Temperature (°C)
Fig. 2 - Max. Average Forward Current vs. Ambient Temperature
Rev. 1.8, 11-Sep-12
25
9
50
75
100
125
150
175
Tj - Junction Temperature (°C)
16464
Fig. 3 - Reverse Current vs. Junction Temperature
PR - Reverse Power Dissipation (mW)
0
IFAV - Average Forward Current (A)
10
1
0.001
15789
100
700
VR = VRRM
600
500
PR - Limit
at 100 % VR
400
300
PR - Limit
at 80 % VR
200
100
0
16465
25
50
75
100
125
150
175
Tj - Junction Temperature (°C)
Fig. 4 - Max. Reverse Power Dissipation vs. Junction Temperature
Document Number: 86059
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
SF1200, SF1600
www.vishay.com
Vishay Semiconductors
CD - Diode Capacitance (pF)
30
f = 1 MHz
25
20
15
10
5
0
0.1
1.0
10.0
100.0
VR - Reverse Voltage (V)
16466
Fig. 5 - Diode Capacitance vs. Reverse Voltage
3.6 (0.142) max.
0.82 (0.032) max.
PACKAGE DIMENSIONS in millimeters (inches): SOD-57
26 (1.024) min.
4 (0.157) max.
26 (1.024) min.
20543
Rev. 1.8, 11-Sep-12
Document Number: 86059
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Revision: 12-Mar-12
1
Document Number: 91000