MURATA LXES2SBBB4-026

LXES2SBBB4-026
1. Application

ESD protection
2. Features
IEC61000-4-2(ESD) ±15kV(air),±10kV(contact)
Low capacitance : 1.0pF typical
 Fast turn on and low clamping voltage
 For 4lines
 RoHS regulation conformity parts


3. Mechanical details (dimensions : mm)
TOP VIEW
END VIEW
Typ2.9
Typ0.6
+0.05
0.4 -0.10
0.45±0.15
+0.07
0.13 -0.05
4°
±4°
(6)
(5)
(4)
Typ0.25
1 pin mark
Typ2.8
026 XY
Typ1.6
SIDE VIEW
Device Code Trace Code
(2)
(1)
(3)
+0.15
1.15 -0.25
Typ0.95
1.35max
Typ1.9
0.15max
No.
Terminal name
1
I/O 1
2
GND
3
I/O 2
4
I/O 3
5
VDD
6
I/O 4
1
LXES2SBBB4-026
4. Schematic
5. Maximum Ratings
Rating
Operating voltage (VDD-GND)
ESD per IEC 61000-4-2 (air)
ESD per IEC 61000-4-2 (contact)
Symbol
Value
Units
VDC
5.5
V
±15
VESD
kV
±10
Lead Soldering Temperature
TSOL
260(10sec.)
o
Operating Temperature
TOP
-40 to +85
o
-40 to +125
o
Storage Temperature
TSTO
C
C
C
6. Electrical characteristics (T=25 oC)
Parameter
Symbol
Conditions
Leakage Current
(I/O-GND)
ILeak
Vpin5=5V, Vpin2=0V, VCH=0-5V
Breakdown Voltage
VBV
IBV = 1mA
Capacitance
(I/O-GND)
CIN
Vpin5=5V, Vpin2=0V, Vin=2.5V,
f=1MHz
2
Min
Typ
6
1.0
Max
Units
1
μA
9
V
pF
LXES2SBBB4-026
7. Typical Characteristic
2.0
80
1.5
60
Cline (pF)
Voltage(V)
100
40
1.0
0.5
20
0.0
0
-10
0
10
20
30
40
0
50
Time(ns)
8. Soldering Footprint (dimensions : mm)
0.95
2.5
1.4
2
VDC (V)
3
4
Voltage – Capacitance Characteristic
ESD Waveform(IEC61000-4-2:8kV Contact)
3.6
1
1.1
0.6
Notes: this land layout is for reference purpose only.
3
5
LXES2SBBB4-026
9. Taping Specification
(in mm)
1) Dimensions of Tape (Plastic tape)
φ 1.55±0.05
4.00±0.10
0.249±0.019
2.00±0.05
A
1.75±0.10
8.00+0.30
-0.10
3.50±0.50
B
B
φ 1.00±0.25
4.00±0.10
2.00±0.05
A
3.17±0.10
9°MAX
B ― B
2) Dimensions of Reel
(in mm)
2.3±0.1
180
φ180max
60.0±0.5
φ13.0±0.2
9.5±1
Φ60.0±0.05
12.3±1
3) Packaging unit: 3000 pcs / reel
Note:
1. This datasheet's specifications are subject to change or our products in it may be discontinued without advance notice. Please check with
our sales representatives or product engineers before ordering.
2. This datasheet has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product
specifications or transact the approval sheet for product specifications before ordering.
4