IRF 5962-87782012A

OM1805N2M
OM1812N2M
OM1815N2M
HERMETIC SURFACE MOUNT FIXED VOLTAGE POSITIVE
REGULATORS APPROVED TO DESC DRAWINGS
LCC 20 Fixed Voltage, Precision
Positive Regulators In Hermetic
Surface Mount Package
FEATURES
•
•
•
•
•
•
Hermetic Surface Mount Package
Output Voltages: +5V, +12V, +15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Hi-Rel Screening Available
DESCRIPTION
These positive regulators are supplied in a hermetically sealed surface mount
package. All protective features are designed into the circuit including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over .5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are +5V, +12V, and +15V.
These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
5962-8778201 2X
5962-8777601 2X
5962-8855301 2X
Omnirel Part Number
OM1805N2M
OM1812N2M
OM1815N2M
3.5
4 11 R0
3.5 - 33
OM1805N2M - OM1815N2M
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1040 mW
Thermal Resistance
θJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20°C/W
θJA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120°C/W
a
ELECTRICAL CHARACTERISTICS 5 Volt
VIN = 10V, Io = 100mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
4.92
5.08
V
4.85
5.15
V
VIN = 7.5V to 20V
•
IO = 5mA to 500 mA, P < 2 W
Line Regulation
VRLINE
VIN = 7.5V to 20V
5
mV
•
12
mV
4
mV
•
10
mV
25
mV
50
mV
6
mA
6.5
mA
VIN = 7.5V to 20V
•
•
0.8
mA
IO = 5mA to 500mA
•
0.5
mA
(Note 1)
VIN = 8.0V to 12V
(Note 4)
Load Regulation
VRLOAD
IO = 5mA to 500 mA
•
(Note 1)
Standby Current Drain
ISCD
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
Dropout Voltage
VDO
TA = 25°C, ∆VOUT = 100mV, IO = 500mA
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
0.5
•
(Note 2)
2.5
V
1.7
A
0.7
A
2.0
A
∆VIN
f =120 Hz, ∆VIN = 10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
75
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
68
•
dB
60
dB
(Note 3)
3.5
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5 - 34
OM1805N2M - OM1815N2M
ELECTRICAL CHARACTERISTICS 12 Volt
VIN = 19V, Io = 100mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
11.88
12.12
V
11.64
12.36
V
18
mV
•
VIN = 14.5V to 27V
IO = 5mA to 500 mA, P < 2W
Line Regulation
VRLINE
VIN = 14.5V to 27V
•
(Note 1)
50
mV
9
mV
VIN = 16V to 22V
(Note 4)
•
Load Regulation
IO = 5mA to 500mA
VRLOAD
•
(Note 1)
Standby Current Drain
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
mV
mV
60
mV
6.0
mA
6.5
mA
VIN = 15V to 30V
•
•
0.8
mA
IO = 5mA to 500mA
•
0.5
mA
•
ISCD
Standby Current Drain
30
30
Dropout Voltage
VDO
∆VOUT = 100mV, IO = 500mA
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
0.5
•
(Note 2)
2.5
V
1.7
A
0.7
A
2.0
A
∆VIN
f =120 Hz, ∆VIN = 10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
120
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
61
•
dB
54
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
Terminal Number
.009 R.
20 PLCS.
.065
.020 X45°
REF.
(±.003)
.040
.010
3
.025
TYP.
.075 (±.010)
TYP.
4
9
.160
SQ. REF.
1
.085
13
19
.003
.025 SQ.
TYP.
18
.050 (±.005)
TYP.
14
.050
TYP.
.040 X45°
REF (3 PL)
NOTE: For normal operation, VOUT must be connected externally
to load.
3.5 - 35
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
NC
VIN
NC
NC
NC
NC
GND
NC
NC
VOUT
NC
VOUT
NC
NC
VOUT SENSE
NC
VIN
NC
NC
NC
3.5
OM1805N2M - OM1815N2M
ELECTRICAL CHARACTERISTICS 15 Volt
VIN = 23V, Io = 100mA, -55°C ≤ TA ≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VOUT
TA = 25°C
14.8
15.2
V
14.6
15.4
V
20
mV
VIN = 18.5V to 30V
•
IO = 5mA to 500 mA, P < 2W
Line Regulation
VRLINE
VIN = 17.5V to 30V
•
(Note 1)
VIN = 20V to 26V
(Note 4)
•
Load Regulation
VRLOAD
IO = 5mA to 500 mA
•
∆ISCD
Change With Line
(Line)
Standby Current Drain
∆ISCD
Change With Load
(Load)
mV
25
mV
50
mV
90
mV
mA
6.5
mA
VIN = 18.5V to 30V
•
•
0.8
mA
IO = 5mA to 500mA
•
0.5
mA
ISCD
Standby Current Drain
mV
15
6.0
(Note 1)
Standby Current Drain
50
Dropout Voltage
VDO
TA = 25°C, ∆VOUT = 100mV, IO = 500mA
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
IDS
VIN = 35V
0.5
•
(Note 2)
2.5
V
1.7
A
0.7
A
2.0
A
∆VIN
f =120 Hz, ∆VIN = 10V
∆VOUT
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
∆VOUT
TA = 25°C, t = 1000 hrs.
150
(Note 3)
∆t
Ripple Rejection
Output Noise Voltage
54
•
dB
52
dB
(Note 3)
µV/V
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5