ETC COM7815T

COM7805T
COM7812T
COM7815T
(COTS) COMMERCIAL OFF-THE-SHELF POSITIVE
FIXED VOLTAGE REGULATORS IN TO-257 PA C KThree Terminal, Fixed Voltage, 1.5 Amp
Precision Positive Regulators In Hermetic
JEDEC TO-257AA Package
FEATURES
•
•
•
•
•
•
Isolated Hermetic Package, JEDEC TO-257AA Outline
Output Voltages: 5V, 12V, 15V
Output Voltages Set Internally ±2%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Standard Off-The-Shelf
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed
metal package whose outline is similar to the industry standard TO-220 plastic package. All
protective features are designed into the circuit including thermal shutdown, current limiting
and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current.
These units feature internally trimmed output voltages to +/- 2% of nominal voltage.
Standard voltages are 5V, 12V, and 15V. However, other voltages are available up to 24
volts. These units are ideally suited for Military applications where a hermetically sealed
package is required.
ABSOLUTE MAXIMUM RATINGS @
25°C
Input Voltage.................................................................. 35 V
Operating Junction Temperature Range .......................... - 55°C to + 150°C
Storage Temperature Range ..................................... - 65°C to + 150°C
Typical Power/Thermal Characteristics:
Rated Power @ 25° C TC .............................................. 17.5W
TA ................................................. 3 W
Thermal Resistance
qJC ........................................... 4.2°C/W
qJA ............................................ 42°C/W
3.3 - 1
3.3
COM7800T Series
ELECTRICAL CHARACTERISTICS
5 Volt
V IN = 10V, Io = 500mA, -55°C
TA
125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Output Voltage
VO U T
TA = 25°C
4.9
5.1
V
4.8
5.2
V
V IN = 7.5V to 20V
Line Regulation
•
V IN = 7.5V to 20V
V RLINE
(Note 1)
5
mV
•
12
mV
4
mV
•
10
mV
12
mV
•
25
mV
6
mV
•
15
mV
V IN = 8.0V to 12V
Load Regulation
IO = 5mA to 1.5 Amp
V RLOAD
(Note 1)
IO = 250mA to 750 mA
Standby Current Drain
6
mA
6.5
mA
V IN = 7.5V to 20V
•
•
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
IS C D
Standby Current Drain
DIS C D
Change With Line
(Line)
Standby Current Drain
DIS C D
Change With Load
(Load)
Dropout Voltage
VD O
TA = 25°C, DV O U T = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
ID S
V IN = 35V
1.5
•
(Note 2)
Ripple Rejection
Output Noise Voltage
DV IN
f =120 Hz, DV IN = 10V
DV O U T
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
•
2.5
V
3.3
A
1.2
A
2.8
A
66
dB
60
dB
40
(Note 3)
µV/V
RMS
Long Term Stability
DV O U T
(Note 3)
Dt
ELECTRICAL CHARACTERISTICS
TA = 25°C, t = 1000 hrs.
12 Volt
75
V IN = 19V, Io = 500mA, -55°C
TA
mV
125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Output Voltage
VO U T
TA = 25°C
11.76
12.24
V
11.6
12.4
V
18
mV
V IN = 14.5V to 27V
Line Regulation
V RLINE
•
V IN = 14.5V to 27V
•
(Note 1)
V IN = 16V to 22V
•
Load Regulation
V RLOAD
IO = 5mA to 1.5 Amp
•
(Note 1)
IO = 250mA to 750 mA
•
Standby Current Drain
3.3
Unit
DIS C D
Change With Line
(Line)
Standby Current Drain
DIS C D
Change With Load
(Load)
mV
30
mV
32
mV
60
mV
20
mV
40
mV
mA
6.5
mA
V IN = 15V to 30V
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
•
2.5
V
3.3
A
Dropout Voltage
VD O
DV O U T = 100mV, IO = 1.0A
IO (pk)
TA = 25°C
Short Circuit Current
ID S
V IN = 35V
1.5
•
(Note 2)
Output Noise Voltage
mV
9
6.0
Peak Output Current
Ripple Rejection
50
•
•
IS C D
Standby Current Drain
Unit
DV IN
f =120 Hz, DV IN = 10V
DV O U T
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
•
1.2
A
2.8
A
61
dB
54
dB
40
(Note 3)
µV/V
RMS
Long Term Stability
DV O U T
(Note 3)
Dt
TA = 25°C, t = 1000 hrs.
120
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
3.3 - 2
COM7800T Series
ELECTRICAL CHARACTERISTICS
15 Volt
V IN = 23V, Io = 500mA, -55°C
TA
125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
VO U T
TA = 25°C
14.7
15.3
V
14.5
15.5
V
20
mV
50
mV
•
V IN = 18.5V to 30V
Line Regulation
V IN = 17.5V to 30V
V RLINE
•
(Note 1)
V IN = 20V to 26V
•
Load Regulation
IO = 5mA to 1.5 Amp
V RLOAD
•
IO = 5mA to 1.0 Amp
(Note 1)
IO = 250mA to 750 mA
•
Standby Current Drain
DIS C D
Change With Line
(Line)
Standby Current Drain
DIS C D
Change With Load
(Load)
mV
35
mV
75
mV
21
mV
45
mV
6.0
mA
6.5
mA
V IN = 18.5V to 30V
0.8
mA
IO = 5mA to 1000mA
•
0.5
mA
2.5
V
Dropout Voltage
VD O
TA = 25°C, DV O U T = 100mV, IO = 1.0A
Peak Output Current
IO (pk)
TA = 25°C
Short Circuit Current
ID S
V IN = 35V
DV IN
f =120 Hz, DV IN = 10V
1.5
•
(Note 2)
Ripple Rejection
mV
25
•
•
IS C D
Standby Current Drain
15
3.3
A
1.2
A
2.8
•
dB
DV O U T
(Note 3)
NO
TA = 25°C, f =10 Hz to 100KHz
40
Long Term Stability
DV O U T
TA = 25°C, t = 1000 hrs.
150
(Note 3)
Dt
Output Noise Voltage
A
54
52
dB
µV/V
(Note 3)
RMS
mV
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN = 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
TYPICAL PERFORMANCE CHARACTERISTICS
PEAK OUTPUT CURRENT
DROPOUT VOLTAGE
Tj = -
2.5
Tj = 25°C
2
1.5
Tj = 150°C
1
0.5
DV O U T = 100mV
0
0
5
10
15
20
25
30
35
100
3.3
IO U T = 1A
2
IO U T =
1.5
IOUT = 0A
1
0.5
0
80
V O U T = 5V
60
40
V IN - V = 8VDC + 3.5 Vrms
IOUT = 1A
Tj = 25°C
20
DV O U T = 100MV
0
-75 -50 -25
Ripple Rejection (dB)
Input To Output Differential (V)
3
Output Current (A)
RIPPLE REJECTION
2.5
3.5
25
50
75 100 125 150
10
Input To Output Differential (V)
Junction Temperature (°C)
3.3 - 3
100
1k
10k
Frequency (Hz)
100k
COM7800T Series
TYPICAL APPLICATIONS
Fixed Output Regulator
INPUT
Circuit For Increasing Output Voltage
OUTPUT
COM78XX
OM7662SC
INPUT
OUTPUT
COM78XX
OM7605SC
VXX
1µFt
R1
0.1µF*
1µF
0.1µF
IQ
R2
R2
VO = VXX (1+ R1 ) + IQ R2
*Increasing value of output capacitor improves system transient response.
Required only if regulator is located an appreciable
distance from power supply filter.
High Output Current,
Short Circuit Protected
INPUT
RSC
R1
Adjustable Output Regulator,
7 To 30 Volts
2N4398
INPUT
2N6124
OM7662SC
COM78XX
OUTPUT
0.33µF
+
MECHANICAL OUTLINE
TO-257AA
0.1µF
LM741
1µF
1µF
OUTPUT
OM7662SC
COM78XX
10K
PIN CONNECTION
.200
.190
.420
.410
Tab
.045
.035
3.3
.665
.645
.150
.140
.537
.527
.430
.410
.038 MAX.
.750
.500
.035
.025
.100 TYP.
.005
.120 TYP.
COM78XXT
Isolated
Front View
Pin 1: Input
Pin 2: Ground
Pin 3: Output
Tab: Isolated
1 2 3
Note:
•Case is metal/hermetically sealed glass feedthroughs
•Isolated Tab