TOSHIBA TORX178S

TORX178S
FIBER OPTIC RECEIVING MODULE
TORX178S
FIBER OPTIC RECEIVING MODULE
FOR DIGITAL AUDIO INTERFACE
Unit: mm
l Conforms to EIAJ Standard CP−1201 (For
Digital Audio Interface including Fiber Optic
inter−connections).
1. Maximum Ratings (Ta = 25°C)
PARAMETER
SYMBOL
RATING
UNIT
Storage Temperature
Tstg
−40~70
°C
Operating Temperature
Topr
−20~70
°C
Supply Voltage
VCC
−0.5~7
V
High Level Output Current
IOH
−1
mA
Low Level Output Current
IOL
5
mA
Soldering Temperature
Tsol
260 (Note 1)
°C
Note 1: Soldering time ≤ 10 s (At a distance of 1 mm from the package).
000707EAC1
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general
can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the
buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and
to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or
damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the
most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling
Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal
equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are
neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or
failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy
control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control
instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document
shall be made at the customer’s own risk.
· Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes are toxic. Do not
break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the products, follow the appropriate
regulations. Do not dispose of the products with other industrial waste or with domestic garbage.
· The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by
TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its
use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or
others.
· The information contained herein is subject to change without notice.
2001-02-28
1/4
TORX178S
2. Recommended Operating Conditions
PARAMETER
Supply Voltage
SYMBOL
MIN
TYP.
MAX
UNIT
VCC
4.75
5.0
5.25
V
3. Electrical and Optical Characteristics (Ta = 25°C, VCC = 5 V)
PARAMETER
SYMBOL
CONDITION
MIN
TYP.
MAX
UNIT
Data Rate
NRZ Code
(Note 2)
0.1
―
6
Mb / s
Transmission Distance
Using APF
(Note 3)
0.2
―
5
m
Pulse Width Distortion
(Note 4)
Maximum Receivable
Power
(Note 5)
Minimum Receivable
Power
(Note 5)
∆tw
Pulse Width = 165 ns
Pulse Cycle = 330 ns
Using TOTX178S
CL = 10 pF
−30
―
30
ns
PMAX
6 Mb / s, Using APF
−14.5
―
―
dBm
PMIN
6 Mb / s, Using APF
―
―
−24
dBm
40
mA
Current Consumption
ICC
―
22
High Level Output Voltage
VOH
3.6
4.0
―
V
Low Level Output Voltage
VOL
―
0.2
0.4
V
Note 2: When non−modulated signal (optical all high or all low level signal) is inputted, output signal is unstable.
When modulated optical high level signal is received, output signal is high. When modulated optical low level
signal is received, output signal is low. The duty factor must be maintained between 25 to 75%.
Note 3: All Plastic Fiber (970 / 1000 µm).
Note 4: Between input of transmitting module and output of TORX178S.
−9
Note 5: BER ≤ 10 , peak value.
4. Mechanical Characteristics (Ta = 25°C)
PARAMETER
SYMBOL
CONDITION
MIN
TYP.
MAX
UNIT
Insertion Force
Using TOCP172, Initial value
―
―
39.2
N
Withdrawal Force
Using TOCP172, Initial value
5.9
―
39.2
N
5. Application Circuit
2001-02-28
2/4
TORX178S
6. Required Optical Fiber with Fiber Optic Connectors
TOCP172−□□B
7. Precautions on Use
(1)
Maximum rating
The maximum ratings are the limit values which must not be exceeded during operation of device.
None of these rating value must not be exceeded. If the maximum rating value is exceeded, the
characteristics of devices may never be restored properly. In extreme cases, the device may be
permanently damages.
(2) Soldering
Optical modules are comprised of internal semiconductor devices. However, in principle, optical
modules are optical components. During soldering, ensure that flux does not contact with the emitting
surface or the detecting surface. Also ensure that proper flux removal is conducted after soldering.
Some optical modules come with a protective cap. The protective cap is used to avoid malfunction
when the optical module is not in use. Note that it is not dust or waterproof.
As mentioned before, optical modules are optical components. Thus, in principle, soldering where
there may be flux residue and flux removal after soldering is not recommended. Toshiba recommend
that soldering be performed without the optical module mounted on the board. Then, after the board
has been cleaned, the optical module should be soldered on to the board manually.
If the optical module cannot be soldered manually, use non−halogen (chlorine−free) flux and make
sure, without cleaning, there is no residue such as chlorine. This is one of the ways to eliminate the
effects of flux. In such a cases, be sure to check the devices’ reliability.
(3) Noise resistance
It is believed that the use of optical transfer devices improve noise resistance. In theory, optical fiber
is not affected by noise at all. However, receiving modules which handle signals whose level is
extremely small, are susceptible to noise.
TOSLINK improve noise resistance to use a conductive case. However, the current signal output by
the optical receiving modules' photodiode is extremely small. Thus, in some environments, shielding
the case may not achieve sufficient noise resistance.
For systems which incorporate TOSLINK, Toshiba recommend testing using the actual device to
check its noise resistance.
Use a simple noise filter on TOSLINK fiber optic transceiving module's power line. If the ripple in the
power supply used is significant, reinforce the filter.
The optical module is to be used in an area which is susceptible to radiated noise, increase the
shielding by covering the optical module and the power line filter with a metallic cover.
(4) Vibration and shock
This module is plastic sealed and has its wire fixed by resin. This structure is relatively resistant to
vibration and shock. In actual equipment, there are sometime cases in which vibration, shock, or
stress is applied to soldered parts or connected parts, resulting in lines cut. A care must be taken in
the design of equipment which will be subject to high levels of vibration.
(5) Attaching the fiber optic receiving module
Solder the fixed pin (pin 4 and 5) of the fiber optic receiving module TORX178S to the printed circuit
board in order to fix it to the board.
(6) Solvent
When using solvent for flux removal, do not use a high acid or high alkali solvent. Be careful not to
pour solvent in to the optical connector ports. If solvent is inadvertently poured in to them, clean it off
using cotton tips.
(7) Protective cap
When the TORX178S is not in use, attach the protective cap.
(8) Supply voltage
Use the supply voltage within the recommended operating condition (VCC = 5 ± 0.25 V). Make sure
that supply voltage does not exceed the maximum rating value of 7 V, even for an instant.
(9) Interface
The TORX178S has a TTL interface. It can be interfaced with any TTL−compatible C−MOS IC.
(10) Output
If the receiver output is at low and is connected to the power supply, or if the output is high and is
connected to GND, the internal IC may be destroyed.
2001-02-28
3/4
TORX178S
(11) Soldering condition
Solder at 260°C or less for no more than ten seconds.
(12) Precautions when disposing of devices and packing materials.
When disposing devices and packing materials, follow the procedures stipulated by local regulations
in order to protect the environment against contamination.
(13) Precautions during use
Toshiba is continually working to improve the quality and the reliability of their products.
Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical
sensitivity and their vulnerability to physical stress. It is the responsibility of the buyer, when
utilizing Toshiba products, to observe standards of safety, and to avoid situations in which the
malfunction or failure of a Toshiba product could cause loss of human life, bodily injury or damage to
property.
When developing equipment, please ensure that Toshiba products are used within the specified
operating ranges set forth in the most recent product specifications. Also, please keep in mind the
precautions and conditions set forth in the Toshiba Semiconductor Reliability Handbook.
2001-02-28