TOSHIBA TPS819

TPS819
TOSHIBA Photo IC Silicon Epitaxial Planar
TPS819
Mobile Phones, PHS, Pagers
Notebook PCs, PDAs
Cameras
Other Equipment Requiring Luminosity Adjustment
Unit: mm
The TPS819 is a linear-output photo-IC which incorporates a
photodiode and a current amp circuit in a single chip. This photo-IC also
incorporates a luminous-efficiency correction filter, so output value is
close to luminosity characteristics.
·
High sensitivity : IL = 50~100 µA
@EV = 100 lx λp = 522 nm LED
·
Luminous efficiency correction filter mounted on detector
: λp = 550 nm (typ.)
·
Open-emitter output
·
Compact and light surface-mount package
―
TOSHIBA
Maximum Ratings (Ta = 25°C)
Weight: 0.017 g (typ.)
Characteristics
Supply voltage
Output voltage
Light current
Symbol
Rating
Unit
VCC
-0.5~7
V
VOUT
<
= VCC
V
IL
10
mA
Permissible power dissipation
P
70
mW
Operating temperature range
Topr
-25~85
°C
Storage temperature range
Tstg
-40~100
°C
Tsol
260
°C
Soldering temperature range
(Note 1)
Note 1: The reflow time and the recommended temperature profile are shown in the section entitled Handling
Precautions.
1
2002-02-28
TPS819
Recommended Operating Conditions
Characteristics
Symbol
Min
Typ.
Max
Unit
Supply voltage
VCC
2.2
¾
5.5
V
Lead resistance
RL
510
¾
¾
W
Electrical and Optical Characteristics (Ta = 25°C)
Characteristics
Symbol
Test Condition
Min
Typ.
Max
Unit
ICC
VCC = 3 V, EV = 1000 lx,
RL = 1 kW
(Note 2)
¾
2
¾
mA
Light current (1)
IL (1)
VCC = 3 V, EV = 10 lx
(Note 2, 5)
¾
20
¾
Light current (2)
IL (2)
VCC = 3 V, EV = 100 lx
(Note 2, 5)
¾
200
¾
Light current (3)
IL (3)
VCC = 3 V, lp = 522 nm,
EV = 100 lx
(Note 3, 5)
50
¾
100
¾
0.03
0.10
VCC = 3.3 V, EV = 0
¾
¾
0.5
mA
Supply current
mA
IL (IR)
IL (3)
Light current ratio
(Note 4, 5)
Dark current
ILEAK
Saturation output voltage
Vo
VCC = 3 V, RL = 75 kW,
EV = 100 lx
(Note 3)
2.2
2.35
¾
V
Peak sensitivity wavelength
lp
¾
¾
550
¾
nm
¾
0.2
¾
¾
1
¾
¾
0.3
¾
¾
0.02
¾
tr
tf
Switching time
td
VCC = 3 V, RL = 5 kW,
lp = 522 nm
(Note 6)
ts
ms
Note 2: CIE standard A light source is used (color temperature = 2856K)
Note 3: Green LED (lp = 522 nm) is used as light source and set an illuminance meter for 100 lx.
Light current classification: A Rank: 50~83.5 mA, B Rank: 60~100 mA
Note 4: Infrared LED (lp = 870 nm) is used as light source for IL (IR) and light current is set to obtain VCC = 3 V and
2
E = 0.01 mW/cm .
Note 5: Light current measurement circuit
IF
VCC
IL
LED
TPS819
OUT
A
IF
Note 6: Rise time/fall time measurement method
Pulse drive
td
VCC
ts
1.5 V
lp = 522 nm
LED
90%
OUT
TPS819
VOUT
RL
10%
GND
2
tr
tf
2002-02-28
TPS819
Package Dimensions
Weight: 0.017 g (typ.)
Pin Connection
3 VCC
Current
amp
4 OUT
1 GND
2 GND
3
2002-02-28
TPS819
Handling Precautions
At power-on in darkness the internal circuit takes about 50 ms to stabilize. During this period the output signal
is unstable and may change. Please take this into account.
Moisture-proof Packing
(1)
To avoid moisture absorption by the resin, the product is packed in an aluminum envelope with silica gel.
(2)
The optical characteristics of the devices may be affected by exposure to moisture in the air before
soldering and they should therefore be stored after opening the moisture proof bag under the following
conditions:
Temperature: 5°C~30°C, Humidity: 60% (max), Storage time: 168 h (max)
Please perform baking when the storage time is expired. Expiration date for an unopened moisture proof
bag is six month and 168 h for an opened moisture proof bag. This device is a tape packed product; hence,
do not bake the product at high temperature:
Recommended baking condition: Baking Temperature = 60°C, Baking Hours = 12 h or longer
(3)
Mounting Precautions
(1)
Do not apply stress to the resin at high temperature.
(2)
The resin part is easily scratched, so avoid friction with hard materials.
(3)
When installing the assembly board in equipment, ensure that this product does not come into contact
with other components.
Mounting Methods
(1)
Reflow soldering
·
Package surface temperature: 260°C (max)
·
Please perform reflow soldering using the following reference temperature profile. Perform reflow
soldering no more than twice.
Temperature (°C) ®
·
260°C max
230°C
190°C
180°C
Preheat
60~120 s
30~50 s
Time (s) ®
·
Please perform the first reflow soldering with reference to the above temperature profile and within
168 h of opening the package.
·
Second reflow soldering
In case of second reflow soldering should be performed within 168 h of the first reflow under the
above conditions.
Storage conditions before the second reflow soldering: 30°C, 60% RH max
·
Do not perform flow soldering.
·
Make any necessary soldering corrections manually.
(only once at each soldering point)
Temperature: 350°C or less
Time: within 5 s
4
2002-02-28
TPS819
(2)
Recommended soldering pattern
1.3
1.6
Unit: mm
0.95
0.6
0.95
1.6
(3)
Cleaning conditions
When cleaning is required after soldering
Chemicals: AK225 alcohol
Temperature and time: 50°C ´ 30 s or : 30°C ´ 3 min
Ultrasonic cleaning: 300 W or less
Packing Display
(1)
(2)
Packing quantity
Reel (minimum packing quantity)
3000 pcs
Carton
5 reels (15000 pcs)
Packing form
To avoid moisture absorption by the resin, the devices are sealed in an aluminum package with silica gel.
Buffer materials are enclosed with carton.
·
Carton appearance
Label position
Carton dimensions
(W) 81 mm ´ (L) 280 mm (H) 280 mm
5
2002-02-28
TPS819
Tape Packing Specifications
(1)
Reel dimensions
11.4 ± 1
+0
f180 - 4
9 ± 0.3
f21 ± 0.3
f13 ± 0.5
f60
2 ± 0.5
Label
Tape dimensions
A’
max 6°
max 6°
Device Orientation
3.6 ± 0.1
B’
0.2 ± 0.05
8.0 ± 0.2
B
4.0 ± 0.1
A
2.0 ± 0.05
3.5 ± 0.1
+ 0.1
f1.5 0
1.75 ± 0.1
4.0 ± 0.1
(2.75)
(2)
2.8 ± 0.1
Feed direction
max 6°
1.3 ± 0.1
A-A’
max 6°
B-B’
6
2002-02-28
TPS819
ILEAK – Ta
P – Ta
80
(typ.)
10
Please refer to Figure 2
(mA)
60
Dark current ILEAK
Power dissipation
P (mW)
70
50
40
30
20
1
0.1
0.01
VCC = 3 V
10
VCC = 5 V
0
0
20
40
60
80
0.001
20
100
40
Ambient temperature Ta (°C)
IL – EV
60
80
100
Ambient temperature Ta (°C)
IL – Ta
(typ.)
10000
(typ.)
1.4
VCC = 3 V
Ta = 25°C
Please refer to Figure 1
Using the A light source
100
1.2
Relative light current
IL (mA)
Light current
Please refer to Figure 1
1000
A light source VCC = 3 V
10
1.0
0.8
Fluorescent light VCC = 3 V
E = 10 lx (A light source)
A light source VCC = 5 V
E = 100 lx (Fluorescent light)
Fluorescent light VCC = 5 V
1
1
10
100
1000
Illuminance EV
10000
E = 100 lx (A light source)
0.6
-40
100000
(lx)
0
20
40
60
80
100
Ambient temperature Ta (°C)
IL – VCC
(typ.)
(typ.)
Vo – EV
1.6
10
Ta = 25°C
(V)
Please refer to Figure 1
Output voltage Vo
1.2
Relative light current
-20
0.8
0.4
VCC = 3 V
Ta = 25°C
Please refer to Figure 4
1
0.1
Fluorescent light 7.5 kW
0.01
Fluorescent light 1 kW
A light source 7.5 kW
A light source 1 kW
0
2
3
4
6
5
Supply voltage VCC
0.001
1
7
(V)
10
100
1000
Illuminance EV
7
10000
100000
(lx)
2002-02-28
TPS819
ICC – EV
(typ.)
Consumption current
ICC
(mA)
10000
VCC = 3 V
Ta = 25°C
Using the A light source
1000 RL = 1 kW
Please refer to Figure 3
100
10
1
1
10
100
Illuminance EV
1000
(lx)
Switching characteristics
(Non-saturating operation)
Switching characteristics
(Saturating operation)
(typ.)
10000
(typ.)
10000
Ta = 25°C
Ta = 25°C
VCC = 3 V
VOUT = 1.5 V
VCC = 3 V
VOUT >
= 2V
lp = 522 nm
lp = 522 nm
Please refer to Figure 5
Please refer to Figure 5
1000
1000
tf
(ms)
td
Switching time
Switching time
(ms)
tf
100
tr
ts
100
td
10
10
ts
tr
1
0.1
1
Load resistance RL
1
0.1
10
(kW)
1
Load resistance RL
8
10
(kW)
2002-02-28
TPS819
Spectral response
Radiation pattern
(typ.)
(typ.)
1.0
Ta = 25°C
Ta = 25°C
Relative sensitivity
0.8
Luminosity angle
0.6
20°
10°
0°
10°
30°
20°
30°
40°
40°
50°
0.4
50°
60°
60°
70°
0.2
70°
80°
0
200
400
600
1000
800
Wavelength l
80°
90°
1200
0
0.2
0.4
0.6
0.8
90°
1.0
Relative sensitivity
(nm)
Measurement Circuits
VCC
VCC
ILEAK
IL
Light
OUT
TPS819
OUT
TPS819
A
A
Figure 1 Light current measurement circuit
Figure 2 Dark current measurement circuit
Icc
VCC
VCC
A
Light
Light
OUT
TPS819
TPS819
RL
RL
lp = 522 nm
LED
Vo
Figure 4 Output voltage measurement circuit
Figure 3 Consumption current measurement circuit
Pulse drive
V
VCC
OUT
TPS819
RL
Figure 5 Switching measurement circuit
9
2002-02-28
TPS819
RESTRICTIONS ON PRODUCT USE
000707EBA
· TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the “Handling Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability
Handbook” etc..
· The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury (“Unintended Usage”). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer’s own risk.
· The products described in this document are subject to the foreign exchange and foreign trade laws.
· The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other
rights of the third parties which may result from its use. No license is granted by implication or otherwise under
any intellectual property or other rights of TOSHIBA CORPORATION or others.
· The information contained herein is subject to change without notice.
10
2002-02-28