BOURNS MF

Features
R0
12255
0S
Applications
■
Radial Leaded Devices
Cured, flame retardant epoxy polymer
insulating material meets UL 94V-0
requirements
Lead free option available
■
Agency recognition:
■
■
Almost anywhere there is a load to be
protected with a voltage supply of up to
90 V, including:
■ Broadband cable power passing taps
■ Set-top boxes
T V Rheinland
MF-R/90 Series - PTC Resettable Fuses
Electrical Characteristics
Ihold
Itrip
Initial
Resistance
Values
Amps
at 23 °C
Amps
at 23 °C
Ohms
at 23 °C
One Hour
Post-Trip
Resistance
Standard Trip
Ohms
at 23 °C
V max.
Volts
I max.
Amps
Hold
Trip
Min.
Max.
Max.
MF-R055/90
90
10
0.55
1.1
0.45
0.9
MF-R055/90U
90
10
0.55
1.1
0.45
MF-R075/90
90
10
0.75
1.5
0.37
Model
Nominal
Tripped
Power
Dissipation
Maximum
Time
To Trip
Watts
at 23 °C
Amps
at 23 °C
Seconds
at 23 °C
2.0
1.6
60
0.9
2.0
1.6
28
2.0
0.75
1.65
2.0
60
2.5
Typ.
2.0
“U” suffix indicates product without insulation coating.
Environmental Characteristics
Operating/Storage Temperature ........................-40 °C to +85 °C
Maximum Device Surface Temperature
in Tripped State ................................................125 °C
Passive Aging......................................................+85 °C, 1000 hours ....................................±5 % typical resistance change
Humidity Aging....................................................+85°C, 85% R.H. 1000 hours......................±5 % typical resistance change
Thermal Shock ....................................................+125 °C to -55 °C, 10 times ........................±10 % typical resistance change
Solvent Resistance ............................................MIL-STD-202, Method 215 ........................No change
Vibration ..............................................................MIL-STD-883C, Method 2007.1, ................No change
Condition A
Test Procedures And Requirements For Model MF-R/90 Series
Test
Test Conditions
Accept/Reject Criteria
Visual/Mech. ......................................................Verify dimensions and materials..................Per MF physical description
Resistance ..........................................................In still air @ 23 °C ........................................Rmin ≤ R ≤ Rmax
Time to Trip ........................................................At specified current, Vmax, 23 °C ..............T ≤ max. time to trip (seconds)
Hold Current ......................................................30 min. at Ihold............................................No trip
Trip Cycle Life ....................................................Vmax, Imax, 100 cycles ..............................No arcing or burning
Trip Endurance....................................................Vmax, 48 hours ..........................................No arcing or burning
UL File Number ..................................................E 174545S
CSA File Number ................................................CA 110338
TÜV File Number ................................................R2057213
Thermal Derating Chart - Ihold / Itrip (Amps)
Ambient Operating Temperature
Model
MF-R055/90
MF-R055/90U
MF-R075/90
-40 ˚C
0.85 / 1.7
0.85 / 1.7
1.15 / 2.3
-20 ˚C
0.75 / 1.5
0.75 / 1.5
1.0 / 2.0
0 ˚C
0.65 / 1.3
0.65 / 1.3
0.9 / 1.8
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
23 ˚C
0.55 / 1.1
0.55 / 1.1
0.75 / 1.5
40 ˚C
0.45 / 0.9
0.45 / 0.9
0.61 / 1.22
50 ˚C
0.4 / 0.8
0.4 / 0.8
0.55 / 1.1
60 ˚C
0.35 / 0.7
0.35 / 0.7
0.48 / 0.96
70 ˚C
0.3 / 0.6
0.3 / 0.6
0.41 / 0.82
85 ˚C
0.22 / 0.44
0.22 / 0.44
0.30 / 0.6
Additional Features
■
■
Bulk packaging, tape and reel and Ammo-Pak available on most models
Patents pending
MF-R/90 Series - PTC Resettable Fuses
Product Dimensions
A
Max.
10.9
(0.43)
10.3
(0.4)
11.9
(0.47)
Model
MF-R055/90
MF-R055/90U
MF-R075/90
Packaging options:
BULK: 500 pcs. per bag.
B
Max.
14.0
(0.55)
10.3
(0.4)
15.5
(0.61)
TAPE & REEL: 1500 pcs. per reel.
C (Pitch)
Nom.
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
5.1 ± 0.7
(0.201 ± 0.028)
D
Min.
6.3
(0.248)
6.3
(0.248)
6.3
(0.248)
E
Max.
3.6
(0.142)
3.0
(0.118)
3.6
(0.142)
Physical Characteristics
Style Lead Dia.
Material
0.81
1
Sn/Cu
(0.032)
0.81
1
Sn/Cu
(0.032)
0.81
1
Sn/Cu
(0.032)
DIMENSIONS =
AMMO-PACK: 1000 pcs. per pack
MM
(INCHES)
Style 1
A
E
Typical Part Marking
How to Order
MF - R 055/90 U - 0 - 99
Represents total content. Layout may vary.
MANUFACTURER'S
TRADEMARK
Multifuse
Product
Designator
LOT NO.
(S = CHINA)
Series
R = Radial Leaded
Component
®
B
PART
IDENTIFICATION
DATE CODE
(FIRST DIGIT =
LAST DIGIT OF YEAR;
NEXT THREE DIGITS =
DAY OF YEAR)
R055
1220S
Hold Current, Ihold
055, 075 (0.55 Amps - 0.75 Amps)
Max. Voltage, V
D
Coating
__ = Coated
U = Uncoated
C
Also available with straight leads.
Packaging Options
- 0 = Bulk Packaging
- 2 = Tape and Reel*
- AP = Ammo-Pak*
Typical Time to Trip at 23 ˚C
Lead Free Option
__ = Standard Product
- 99 = Lead Free
100
Time to Trip (Seconds)
*Packaged per EIA486-B
10
1
MF-R075/90
MF-R055/90
MF-R055/90U
0.1
1
10
Fault Current (Amps)
MF-R/90, REV. C, 02/04
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
MF-R, MF-RX, MF-R/90, MF-R/250, MF-RX/250 & MF-R/600 Series
Tape and Reel Specifications
Devices taped using EIA468–B/IEC286-2 standards. See table below and Figures 1 and 2 for details.
Dimension Description
IEC
Mark
EIA
Mark
Carrier tape width
W
W
Hold down tape width: MF-R/600
W4
Hold down tape width: all others
W4
Hold down tape
W0
Top distance between tape edges
W2
Dimensions
Dimensions
Tolerance
18
(.709)
5
(.197)
11
(.433)
Lead protrusion
I1
Protrusion of cutout
L
L
Protrusion beyond hold tape
I2
I2
Not specified
Sprocket hole pitch
P0
P0
12.7
(0.5)
W6
Sprocket hole position
W1
W5
Sprocket hole diameter
D0
D0
Abscissa to plane (straight lead)
H
H
Abscissa to plane (kinked lead)
H0
H0
Abscissa to top
H1
H1
Overall width w/lead protrusion
C1
Overall width w/o lead protrusion
C2
L1
Pitch tolerance
20 consecutive
Device pitch: MF-R005 – MF-R160 & MF-R/90
Device pitch: MF-R185 – MF-R400 & MF-R/600
Device pitch: MF-RX110 – MF-RX160
Device pitch: MF-RX185 – MF-RX375
Device pitch: MF-R/250 & MF-RX/250
t
t
t1
Tape thickness with splice
Splice sprocket hole alignment
12.7
(0.5)
25.4
(1.0)
12.7
(0.5)
12.7
(0.5)
12.7
(0.5)
0.9
(.035)
2.0
(.079)
0
Body lateral deviation
∆h
∆h
Body tape plane deviation
∆p
∆p
0
3.81
(.015)
Lead seating plane deviation: MF-R/600*
∆P1
P1
Lead seating plane deviation
∆P1
P1
Lead spacing
F
F
Reel width
w
w
Reel diameter
d
a
Space between flanges less device
*Differs from EIA specification.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
min.
ref.
No protrusion
3
(.118)
9
(.354)
4
(.157)
18.5
(.728)
16
(.63)
32.2
(1.268)
43.2
(1.7)
42.5
(1.673)
1.0
(.039)
11
(.433)
Tape thickness
-0.5/+1.0
(-0.02/+.039)
0
0
5.08
(0.2)
56
(2.205)
370
(14.57)
4.75
(.187)
max.
-0.5/+0.75
(-0.02/+0.03)
±0.2
(±.0078)
±3.0
(±.118)
±0.5
(±.02)
max.
max.
max.
max.
max.
±0.3
(±.012)
±1
max.
max.
±0.3
(±.012)
±1.0
(±.039)
±1.3
(±.051)
±0.7
(±.028)
±0.7
(±.028)
±0.8
(±.035)
max.
max.
±3.25
(±.128)
DIMENSIONS =
MM
(INCHES)
MF-R, MF-RX, MF-R/90, MF-R/250, MF-RX/250 & MF-R/600 Series
Tape and Reel Specifications
IEC
Mark
Dimension Description
EIA
Mark
Dimensions
Dimensions
Tolerance
Space between flanges less device
Arbor hole diameter
f
c
Core diameter: MF-R, MF-RX, MF-R/90 & MF-R/250
h
n
Core diameter: MF-RX/250 & MF-R/600
h
n
4.75
(.187)
26
(1.024)
±3.25
(±.128)
±12.0
(±.472)
80
(3.15)
max.
91
(3.58)
372
(14.6)
372
(14.6)
372
(14.6)
56
(2.2)
67
(2.64)
64
(2.52)
Box: MF-R, MF-RX, MF-R/90 & MF-R/250
Box: MF-RX/250
Box: MF-R/600
max.
372
(14.6)
362
(14.25)
362
(14.25)
max.
max.
max.
Consecutive missing places:
MF-R, MF-RX, MF-R/90 & MF-R/250
3
Consecutive missing places: MF-RX/250 & MF-R/600
max.
None
Empty places per reel:
MF-R, MF-RX, MF-R/90 & MF-R/250
Not specified
Empty places per reel: MF-RX/250 & MF-R/600
0.1 %
Taped Component Dimensions - Figure 1
∆p
∆h
∆h
∆p
Reference plane
P1
H1
A
L
I2
H1
F
H
H0
B
W0
I1
P0
D0
DIMENSIONS =
MM
(INCHES)
W1
W
User direction of feed
Cross section A - B
Reel Dimensions - Figure 2
t
Reel
h
d
User
direction
of
feed
Upper side
Tape
Lower side
f
h
w
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.