ZPY3V9 to ZPY100 www.vishay.com Vishay Semiconductors Zener Diodes FEATURES • Silicon planar power Zener diodes • For use in stabilizing and clipping circuits with high power rating • The Zener voltages are graded according to the international E 12 standard. Smaller voltage tolerances are available upon request • These diodes are also available in the MELF case with the type designation ZMY3V9 to ZMY100 • Compliant to RoHS Directive 2002/95/EC and in accordance to WEEE 2002/96/EC PRIMARY CHARACTERISTICS PARAMETER VALUE UNIT VZ range nom. 3.9 to 100 V Test current IZT 5 to 100 mA VZ specification Pulse current Int. construction Single • Halogen-free according to IEC 61249-2-21 definition ORDERING INFORMATION DEVICE NAME ORDERING CODE TAPED UNITS PER REEL MINIMUM ORDER QUANTITY ZPY3V9 to ZPY100 ZPY3V9 to ZPY100-series-TR 5000 (52 mm tape on 13" reel) 25 000/box ZPY3V9 to ZPY100 ZPY3V9 to ZPY100-series-TAP 5000 per ammopack (52 mm tape) 25 000/box PACKAGE PACKAGE NAME DO-41 WEIGHT 310 mg MOLDING COMPOUND MOISTURE SENSITIVITY FLAMMABILITY RATING LEVEL UL 94 V-0 MSL level 1 (according J-STD-020) SOLDERING CONDITIONS 260 °C/10 s at terminals ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified) PARAMETER Power dissipation Zener current Junction to ambient air Junction temperature Storage temperature range Rev. 1.9, 22-Nov-11 TEST CONDITION SYMBOL VALUE UNIT Valid provided that leads at a distance of 4 mm from case are kept at ambient temperature Ptot 1300 mW RthJA 110 K/W Tj 175 °C Tstg - 55 to + 175 °C See table “Caharacteristics” Valid provided that leads at a distance of 4 mm from case are kept at ambient temperature Document Number: 85790 1 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 ZPY3V9 to ZPY100 www.vishay.com Vishay Semiconductors ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified) ZENER VOLTAGE RANGE (2) TEST CURRENT REVERSE VOLTAGE DYNAMIC RESISTANCE f = 1 kHz ADMISSIBLE ZENER CURRENT (1) TEMPERATURE COEFFICIENT OF ZENER VOLTAGE VZ at IZT1 IZT1 VR at IR ZZ at IZT1 IZ TCVZ at IZT1 V mA V μA Ω mA 10-4/°C PART NUMBER MIN. MAX. ZPY3V9 MIN. 3.7 NOM. MAX. 3.9 4.1 100 - 0.5 4 (< 7) TYP. 290 -7 2 ZPY4V3 4 4.3 4.6 100 - 0.5 4 (< 7) 260 -7 3 ZPY4V7 4.4 4.7 5 100 - 0.5 4 (< 7) 235 -7 4 ZPY5V1 4.8 5.1 5.4 100 > 0.7 0.5 2 (< 5) 215 -6 5 ZPY5V6 5.2 5.6 6 100 > 1.5 0.5 1 (< 2) 193 -3 5 ZPY6V2 5.8 6.2 6.6 100 > 2.0 0.5 1 (< 2) 183 -1 6 ZPY6V8 6.4 6.8 7.2 100 > 3.0 0.5 1 (< 2) 157 0 7 ZPY7V5 7 7.5 7.9 100 > 5.0 0.5 1 (< 2) 143 0 7 ZPY8V2 7.7 8.2 8.7 100 > 6.0 0.5 1 (< 2) 127 3 8 ZPY9V1 8.5 9.1 9.6 50 > 7.0 0.5 2 (< 4) 117 3 8 ZPY10 9.41 10 10.6 50 > 7.5 0.5 2 (< 4) 105 5 9 ZPY11 10.4 11 11.6 50 > 8.5 0.5 3 (< 7) 94 5 10 ZPY12 11.4 12 12.7 50 > 9.0 0.5 3 (< 7) 85 5 10 ZPY13 12.4 13 14.1 50 > 10 0.5 4 (< 9) 78 5 10 ZPY15 13.8 15 15.8 50 > 11 0.5 4 (< 9) 70 5 10 ZPY16 15.3 16 17.1 25 > 12 0.5 5 (< 10) 63 7 11 ZPY18 16.8 18 19.1 25 > 14 0.5 5 (< 11) 57 7 11 ZPY20 18.8 20 21.2 25 > 15 0.5 6 (< 12) 52 7 11 ZPY22 20.8 22 23.3 25 > 17 0.5 7 (< 13) 48 7 11 ZPY24 22.8 24 25.6 25 > 18 0.5 8 (< 14) 42 7 12 ZPY27 25.1 27 28.9 25 > 20 0.5 9 (< 15) 38 7 12 ZPY30 28 30 32 25 > 22.5 0.5 10 (< 20) 35 7 12 ZPY33 31 33 35 25 > 25 0.5 11 (< 20) 31 7 12 ZPY36 34 36 38 10 > 27 0.5 25 (< 60) 29 7 12 ZPY39 37 39 41 10 > 29 0.5 30 (< 60) 26 8 12 ZPY43 40 43 46 10 > 32 0.5 35 (< 80) 24 8 13 ZPY47 44 47 50 10 > 35 0.5 40 (< 80) 22 8 13 ZPY51 48 51 54 10 > 38 0.5 45 (< 100) 20 8 13 ZPY56 52 56 60 10 > 42 0.5 50 (< 100) 18 8 13 ZPY62 58 62 66 10 > 47 0.5 60 (< 130) 16 8 13 ZPY68 64 68 72 10 > 51 0.5 65 (< 130) 14 8 13 ZPY75 70 75 79 10 > 56 0.5 70 (< 160) 13 8 13 ZPY82 77 82 88 10 > 61 0.5 80 (< 160) 12 8 13 ZPY91 85 91 96 5 > 68 0.5 120 (< 250) 11 9 13 ZPY100 94 100 106 5 > 75 0.5 130 (< 250) 10 9 13 Notes (1) Valid provided that leads are kept at ambient temperature at a distance of 10 mm from case (2) Tested with pulses t = 5 ms p Rev. 1.9, 22-Nov-11 Document Number: 85790 2 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 ZPY3V9 to ZPY100 www.vishay.com Vishay Semiconductors BASIC CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified) W 2 Ω 103 ZPY... ZPY... 7 5 4 Ptot rzj 3 2 102 1 ZPY100 ZPY82 ZPY68 ZPY56 ZPY43 7 5 4 3 2 10 0.1 0 0 200 °C 100 Tamb Fig. 1 - Admissible Power Dissipation vs. Ambient Temperature °C/W 103 rthA gzpy1_07 Fig. 4 - Dynamic Resistance vs. Zener Current Ω 100 ZPY... 5 4 3 rzj 102 2 10 ZPY43 0.5 0.2 tP 0.02 0.01 5 4 3 t v= T T PI ZPY22 ZPY18 2 1 10-4 10-3 10-2 10-5 ZPY30 ZPY24 7 P ___ 1 ZPY36 10 0.1 0.05 5 4 3 2 10-1 1 tP 10 s Ω 103 1 2 3 4 5 10 ZPY... 5 4 3 2 2 3 4 5 IZ gzpy1_05 Fig. 2 - Pulse Thermal Resistance vs. Pulse Duration 100 mA gzpy1_08 Fig. 5 - Dynamic Resistance vs. Zener Current °C/W 200 ZPY... l l RthA ZPY5.1 10 10 mA 3 4 5 2 7 5 4 3 2 2 1 IZ ZPY... 5 4 3 2 rzj 3 4 5 2 gzpy1_04 ZPY4.3 5 4 3 2 ZPY18 ZPY12 100 10 5 4 3 2 ZPY6.2 ZPY1 ZPY10 1 1 2 3 4 5 7 10 ZPY7.5 2 IZ 3 4 5 7 100 mA gzpy1_06 Fig. 3 - Dynamic Resistance vs. Zener Current Rev. 1.9, 22-Nov-11 0 0 5 10 15 lead length l 20 mm gzpy1_09 Fig. 6 - Thermal Resistance vs. Lead Length Document Number: 85790 3 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 ZPY3V9 to ZPY100 www.vishay.com Vishay Semiconductors mA Tj = 25 °C ZPY56 ZPY5.6 IZ ZPY6.8 160 120 20 Tj = 25 °C ZPY3.9 ZPY4.7 200 IZ mA ZPY... 240 ZPY68 Test Current lZ 10 mA ZPY8.2 Test Current lZ 100 mA ZPY82 ZPY100 10 ZPY10 ZPY12 80 5 mA 50 mA 40 0 0 0 1 2 3 4 5 6 8 7 9 10 11 12 13 14 15 V VZ 0 50 150 100 VZ gzpy1_01 Fig. 7 - Breakdown Characteristics 200 V gzpy1_03 Fig. 9 - Breakdown Characteristics mA ZPY... 60 ZPY18 ZPY15 ZPY22 50 IZ Tj = 25 °C ZPY27 40 Test Current lZ 25 mA 30 ZPY33 ZPY39 ZPY47 20 10 mA 10 0 0 5 10 15 20 25 30 35 40 VZ 45 50 V gzpy1_02 Fig. 8 - Breakdown Characteristics PACKAGE DIMENSIONS in millimeters (inches): DO-41 26 (1.024) min. 4.1 (0.161) max. 26 (1.024) min. 2.6 (0.102) max. 0.86 (0.034) max. Cathode identification 94 9368 Rev. 1.9, 22-Nov-11 Document Number: 85790 4 For technical questions within your region: [email protected], [email protected], [email protected] THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000 Legal Disclaimer Notice www.vishay.com Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Material Category Policy Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (EEE) - recast, unless otherwise specified as non-compliant. Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU. Revision: 12-Mar-12 1 Document Number: 91000