VISHAY ZPY30

ZPY3V9 to ZPY100
www.vishay.com
Vishay Semiconductors
Zener Diodes
FEATURES
• Silicon planar power Zener diodes
• For use in stabilizing and clipping circuits with
high power rating
• The Zener voltages are graded according to the
international E 12 standard. Smaller voltage
tolerances are available upon request
• These diodes are also available in the MELF
case with the type designation ZMY3V9 to ZMY100
• Compliant to RoHS Directive 2002/95/EC and in
accordance to WEEE 2002/96/EC
PRIMARY CHARACTERISTICS
PARAMETER
VALUE
UNIT
VZ range nom.
3.9 to 100
V
Test current IZT
5 to 100
mA
VZ specification
Pulse current
Int. construction
Single
• Halogen-free according to IEC 61249-2-21 definition
ORDERING INFORMATION
DEVICE NAME
ORDERING CODE
TAPED UNITS PER REEL
MINIMUM ORDER QUANTITY
ZPY3V9 to ZPY100
ZPY3V9 to ZPY100-series-TR
5000 (52 mm tape on 13" reel)
25 000/box
ZPY3V9 to ZPY100
ZPY3V9 to ZPY100-series-TAP
5000 per ammopack
(52 mm tape)
25 000/box
PACKAGE
PACKAGE NAME
DO-41
WEIGHT
310 mg
MOLDING COMPOUND MOISTURE SENSITIVITY
FLAMMABILITY RATING
LEVEL
UL 94 V-0
MSL level 1
(according J-STD-020)
SOLDERING
CONDITIONS
260 °C/10 s at terminals
ABSOLUTE MAXIMUM RATINGS (Tamb = 25 °C, unless otherwise specified)
PARAMETER
Power dissipation
Zener current
Junction to ambient air
Junction temperature
Storage temperature range
Rev. 1.9, 22-Nov-11
TEST CONDITION
SYMBOL
VALUE
UNIT
Valid provided that leads at a distance of 4 mm
from case are kept at ambient temperature
Ptot
1300
mW
RthJA
110
K/W
Tj
175
°C
Tstg
- 55 to + 175
°C
See table “Caharacteristics”
Valid provided that leads at a distance of 4 mm
from case are kept at ambient temperature
Document Number: 85790
1
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
ZPY3V9 to ZPY100
www.vishay.com
Vishay Semiconductors
ELECTRICAL CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
ZENER VOLTAGE
RANGE (2)
TEST
CURRENT
REVERSE
VOLTAGE
DYNAMIC
RESISTANCE
f = 1 kHz
ADMISSIBLE
ZENER
CURRENT (1)
TEMPERATURE
COEFFICIENT OF ZENER
VOLTAGE
VZ at IZT1
IZT1
VR at IR
ZZ at IZT1
IZ
TCVZ at IZT1
V
mA
V
μA
Ω
mA
10-4/°C
PART NUMBER
MIN.
MAX.
ZPY3V9
MIN.
3.7
NOM. MAX.
3.9
4.1
100
-
0.5
4 (< 7)
TYP.
290
-7
2
ZPY4V3
4
4.3
4.6
100
-
0.5
4 (< 7)
260
-7
3
ZPY4V7
4.4
4.7
5
100
-
0.5
4 (< 7)
235
-7
4
ZPY5V1
4.8
5.1
5.4
100
> 0.7
0.5
2 (< 5)
215
-6
5
ZPY5V6
5.2
5.6
6
100
> 1.5
0.5
1 (< 2)
193
-3
5
ZPY6V2
5.8
6.2
6.6
100
> 2.0
0.5
1 (< 2)
183
-1
6
ZPY6V8
6.4
6.8
7.2
100
> 3.0
0.5
1 (< 2)
157
0
7
ZPY7V5
7
7.5
7.9
100
> 5.0
0.5
1 (< 2)
143
0
7
ZPY8V2
7.7
8.2
8.7
100
> 6.0
0.5
1 (< 2)
127
3
8
ZPY9V1
8.5
9.1
9.6
50
> 7.0
0.5
2 (< 4)
117
3
8
ZPY10
9.41
10
10.6
50
> 7.5
0.5
2 (< 4)
105
5
9
ZPY11
10.4
11
11.6
50
> 8.5
0.5
3 (< 7)
94
5
10
ZPY12
11.4
12
12.7
50
> 9.0
0.5
3 (< 7)
85
5
10
ZPY13
12.4
13
14.1
50
> 10
0.5
4 (< 9)
78
5
10
ZPY15
13.8
15
15.8
50
> 11
0.5
4 (< 9)
70
5
10
ZPY16
15.3
16
17.1
25
> 12
0.5
5 (< 10)
63
7
11
ZPY18
16.8
18
19.1
25
> 14
0.5
5 (< 11)
57
7
11
ZPY20
18.8
20
21.2
25
> 15
0.5
6 (< 12)
52
7
11
ZPY22
20.8
22
23.3
25
> 17
0.5
7 (< 13)
48
7
11
ZPY24
22.8
24
25.6
25
> 18
0.5
8 (< 14)
42
7
12
ZPY27
25.1
27
28.9
25
> 20
0.5
9 (< 15)
38
7
12
ZPY30
28
30
32
25
> 22.5
0.5
10 (< 20)
35
7
12
ZPY33
31
33
35
25
> 25
0.5
11 (< 20)
31
7
12
ZPY36
34
36
38
10
> 27
0.5
25 (< 60)
29
7
12
ZPY39
37
39
41
10
> 29
0.5
30 (< 60)
26
8
12
ZPY43
40
43
46
10
> 32
0.5
35 (< 80)
24
8
13
ZPY47
44
47
50
10
> 35
0.5
40 (< 80)
22
8
13
ZPY51
48
51
54
10
> 38
0.5
45 (< 100)
20
8
13
ZPY56
52
56
60
10
> 42
0.5
50 (< 100)
18
8
13
ZPY62
58
62
66
10
> 47
0.5
60 (< 130)
16
8
13
ZPY68
64
68
72
10
> 51
0.5
65 (< 130)
14
8
13
ZPY75
70
75
79
10
> 56
0.5
70 (< 160)
13
8
13
ZPY82
77
82
88
10
> 61
0.5
80 (< 160)
12
8
13
ZPY91
85
91
96
5
> 68
0.5
120 (< 250)
11
9
13
ZPY100
94
100
106
5
> 75
0.5
130 (< 250)
10
9
13
Notes
(1) Valid provided that leads are kept at ambient temperature at a distance of 10 mm from case
(2) Tested with pulses t = 5 ms
p
Rev. 1.9, 22-Nov-11
Document Number: 85790
2
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
ZPY3V9 to ZPY100
www.vishay.com
Vishay Semiconductors
BASIC CHARACTERISTICS (Tamb = 25 °C, unless otherwise specified)
W
2
Ω
103
ZPY...
ZPY...
7
5
4
Ptot
rzj
3
2
102
1
ZPY100
ZPY82
ZPY68
ZPY56
ZPY43
7
5
4
3
2
10
0.1
0
0
200 °C
100
Tamb
Fig. 1 - Admissible Power Dissipation vs. Ambient Temperature
°C/W
103
rthA
gzpy1_07
Fig. 4 - Dynamic Resistance vs. Zener Current
Ω
100
ZPY...
5
4
3
rzj
102
2
10
ZPY43
0.5
0.2
tP
0.02
0.01
5
4
3
t
v=
T
T
PI
ZPY22
ZPY18
2
1
10-4 10-3 10-2
10-5
ZPY30
ZPY24
7
P
___
1
ZPY36
10
0.1
0.05
5
4
3
2
10-1
1
tP
10 s
Ω
103
1
2
3 4 5
10
ZPY...
5
4
3
2
2
3 4 5
IZ
gzpy1_05
Fig. 2 - Pulse Thermal Resistance vs. Pulse Duration
100 mA
gzpy1_08
Fig. 5 - Dynamic Resistance vs. Zener Current
°C/W
200
ZPY...
l
l
RthA
ZPY5.1
10
10 mA
3 4 5
2
7
5
4
3
2
2
1
IZ
ZPY...
5
4
3
2
rzj
3 4 5
2
gzpy1_04
ZPY4.3
5
4
3
2
ZPY18
ZPY12
100
10
5
4
3
2
ZPY6.2
ZPY1 ZPY10
1
1
2
3 4 5 7
10
ZPY7.5
2
IZ
3 4 5
7
100 mA
gzpy1_06
Fig. 3 - Dynamic Resistance vs. Zener Current
Rev. 1.9, 22-Nov-11
0
0
5
10
15
lead length l
20 mm
gzpy1_09
Fig. 6 - Thermal Resistance vs. Lead Length
Document Number: 85790
3
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
ZPY3V9 to ZPY100
www.vishay.com
Vishay Semiconductors
mA
Tj = 25 °C
ZPY56
ZPY5.6
IZ
ZPY6.8
160
120
20
Tj = 25 °C
ZPY3.9 ZPY4.7
200
IZ
mA
ZPY...
240
ZPY68
Test Current lZ
10 mA
ZPY8.2
Test Current lZ
100 mA
ZPY82
ZPY100
10
ZPY10
ZPY12
80
5 mA
50 mA
40
0
0
0
1
2
3
4
5
6
8
7
9
10 11 12 13 14 15 V
VZ
0
50
150
100
VZ
gzpy1_01
Fig. 7 - Breakdown Characteristics
200 V
gzpy1_03
Fig. 9 - Breakdown Characteristics
mA
ZPY...
60
ZPY18
ZPY15
ZPY22
50
IZ
Tj = 25 °C
ZPY27
40
Test Current lZ
25 mA
30
ZPY33
ZPY39
ZPY47
20
10 mA
10
0
0
5
10
15
20
25
30
35
40
VZ
45 50 V
gzpy1_02
Fig. 8 - Breakdown Characteristics
PACKAGE DIMENSIONS in millimeters (inches): DO-41
26 (1.024) min.
4.1 (0.161) max.
26 (1.024) min.
2.6 (0.102) max.
0.86 (0.034) max.
Cathode identification
94 9368
Rev. 1.9, 22-Nov-11
Document Number: 85790
4
For technical questions within your region: [email protected], [email protected], [email protected]
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Revision: 12-Mar-12
1
Document Number: 91000