Schottky Barrier Diode, 500mA, 30V Type
■FEATURES
■APPLICATIONS
Forward Voltage
: VF=0.40V (TYP.)
●Rectification
Forward Current
: IF(AV)=500mA
●Protection against reverse connection of battery
Repetitive Peak Reverse Voltage : VRM=30V
■ABSOLUTE MAXIMUM RATINGS
■PACKAGING INFORMATION
Ta=25℃
PARAMETER
SYMBOL
RATINGS
UNIT
VRM
30
V
VR
20
V
IF(AV)
500
mA
IFSM
5
A
Tj
125
℃
Tstg
-55∼+150
℃
Repetitive Peak Voltage
Reverse Voltage (DC)
Forward Current (Average)
Non Continuous
Forward Surge Current
*1
Junction Temperature
Storage Temperature Range
*1:Non continuous high amplitude 60Hz half-sine wave.
■MARKING RULE
Cathode Bar
①②
①: 0 (Product Number)
②: Assembly Lot Number
Unit : mm
SOD-323A
■PRODUCT NAME
PRODUCT NAME
XBS053V13□
*
DEVICE ORIENTATION
R
: Embossed tape, standard feed
* □ Please put the device orientation type “R”.
■ELECTRICAL CHARACTERISTICS
PARAMETER
SYMBOL
Forward Voltage
TEST CONDITIONS
Ta=25℃
LIMITS
MIN.
TYP.
MAX.
UNIT
VF1
IF=100mA
-
0.28
-
V
VF2
IF=500mA
-
0.40
0.47
V
Reverse Current
IR
VR=20V
-
-
100
μA
Inter-Terminal Capacity
Ct
VR=10V , f=1MHz
-
12
-
pF
trr
IF=IR=10mA , irr=1mA
-
8
-
ns
Reverse Recovery Time
*2
*2:trr measurement circuit
Bias
Pulse Generatrix
Device Under Test
Oscilloscope
1/3
XBS053V13
■TYPICAL PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage
(2) Reverse Current vs. Reverse Voltage
100
1
Ta=125℃
0.1
-25℃
75℃
10
Reverse
IR (mA)
ReverseCurrent:
Current I
R (mA)
Forward Current: IF (A)
Forward Current IF (A)
Ta=125℃
25℃
0.01
75℃
1
0.1
25℃
0.01
0.001
0.001
0
0.2
0.4
0
0.6
10
20
30
Reverse
VRR(V)
(V)
ReverseVoltage:
Voltage V
ForwardVoltage V
Voltage: VF(V)
(V)
Forward
F
(3) Forward Voltage vs. Operating Temperature
(4) Reverse Current vs. Operating Temperature
0.6
100
0.4
IF=0.5A
0.1A
0.2
10
Reverse
Current I
R (mA)
Reverse
Current:
IR (mA)
Forward
Voltage:
VF (V) (V)
Forward
Voltage V
F
VR=20V
0.01A
0.0
10V
5V
1
0.1
0.01
0.001
-50
0
50
100
150
0
Operating Temperature: Ta (℃)
Operating Temperature Ta (℃)
150
(6) Average Forward Current vs. Operating Temperature
1.0
Average
Current: IFAV
(A)
Average Forward
Forward Current IF
AV (A)
100
Inter-Terminal Capacity: Ct (pF)
Inter-Terminal Capacity Ct (pF)
100
Operating Temperature: Ta (℃)
Operating Temperature Ta (℃)
(5) Inter-Terminal Capacity vs. Reverse Voltage
75
50
25
Ta=25℃
0.8
0.5
0.3
0.0
0
0
10
20
Reverse
Voltage:
VR (V)(V)
Reverse
Voltage V
R
2/3
50
30
0
50
100
Operating
Ta (℃)
OperatingTemperature:
Temperature Ta
(℃)
150
XBS053V13
1. The products and product specifications contained herein are subject to change without
notice to improve performance characteristics.
Consult us, or our representatives
before use, to confirm that the information in this catalog is up to date.
2. We assume no responsibility for any infringement of patents, patent rights, or other
rights arising from the use of any information and circuitry in this catalog.
3. Please ensure suitable shipping controls (including fail-safe designs and aging
protection) are in force for equipment employing products listed in this catalog.
4. The products in this catalog are not developed, designed, or approved for use with such
equipment whose failure of malfunction can be reasonably expected to directly
endanger the life of, or cause significant injury to, the user.
(e.g. Atomic energy; aerospace; transport; combustion and associated safety
equipment thereof.)
5. Please use the products listed in this catalog within the specified ranges.
Should you wish to use the products under conditions exceeding the specifications,
please consult us or our representatives.
6. We assume no responsibility for damage or loss due to abnormal use.
7. All rights reserved. No part of this catalog may be copied or reproduced without the
prior permission of Torex Semiconductor Ltd.
3/3