OPTOWAY SPS-93120BF

Optoway
1
SPS-93120F-CXX0G
***********************************************************************************************************************************************************************
SPS-93120F-CXX0G / SPS-93120BF-CXX0G
(RoHS Compliant)
3.3V / CWDM / 2.125 Gbps SFP LC SINGLE-MODE TRANSCEIVER
**********************************************************************************************************************************************************************
FEATURES
DESCRIPTION
l Hot-Pluggable SFP Footprint LC Optical Transceiver
l Small Form-Factor Pluggable (SFP) MSA compatible
l 18 Wavelength (λ): 1270 nm to 1610 nm CWDM DFB
LD Transmitter
l Compliant with IEEE 802.3z 1000BASE
l Compliant with Fibre Channel 1X/2X SM-LC-L FC-PI
l APD High Sensitivity Receiver
l 30 dB Power Budget at Least
l AC/AC Coupling according to MSA
l Single +3.3 V Power Supply
l RoHS Compliant
l 0 to 70oC Operation: SPS-93120F-CXX0G
l -5 to 85 oC Operation: SPS-93120BF-CXX0G
l Class 1 Laser International Safety Standard IEC 60825
Compliant
The SPS-93120F-CXX0G series single mode transceivers
is small form factor pluggable module for bi-directional
serial optical data communications such as Gigabit Ethernet
1000BASE-ZX and Fibre Channel 1Xx/2X SM-LC-L
FC-PI. It is with the SFP 20-pin connector to allow hot plug
capability. This module is designed for single mode fiber
and operates at a nominal wavelength of CWDM
wavelength. There are eight center wavelengths available
from 1470 nm to 1610 nm, with each step 20 nm. A
guaranteed minimum optical link budget of 30 dB is
offered The transmitter section uses a multiple quantum
well CWDM DFB laser and is a class 1 laser compliant
according to International Safety Standard IEC-60825. The
receiver section uses an integrated InGaAs detector
preamplifier (IDP) mounted in an optical header and a
limiting post-amplifier IC.
APPLICATIONS
LASER SAFETY
l
l
l
l
This single mode transceiver is a Class 1 laser product. It
complies with IEC-60825 and FDA 21 CFR 1040.10 and
1040.11. The transceiver must be operated within the
specified temperature and voltage limits. The optical ports
of the module shall be terminated with an optical connector
or with a dust plug.
ATM Switches and Routers
SONET / SDH Switch Infrastructure
XDSL Applications
Metro Edge Switching
ORDER INFORMATION
P/No.
Bit Rate
(Gb/s)
FC-PI
SPS-93120F-CXX0G 2.125/1.063 200/100
SPS-93120BF-CXX0G 2.125/1.063 200/100
Power
Budget
(dB)
> 30
> 30
Wavelength Package
(nm)
CWDM*
CWDM*
LC SFP
LC SFP
Temp.
(oC)
0 to 70
-5 to 85
TX Power RX Sens.
RoHS
(dBm)
(dBm) Compliant
5 to 0
5 to 0
-30
-30
Yes
Yes
CWDM* Wavelength (0 to 70oC)
Central
Wavelength
-C270
-C290
-C310
-C330
-C350
-C370
-C390
-C410
-C430
Min.
(nm)
1264.5
1284.5
1304.5
1324.5
1344.5
1364.5
1384.5
1404.5
1424.5
Typ.
(nm)
1270
1290
1310
1330
1350
1370
1390
1410
1430
Max.
(nm)
1277.5
1297.5
1317.5
1337.5
1357.5
1377.5
1397.5
1417.5
1437.5
Clasp Color
Central
Code
Wavelength
Light Purple
-C450
Sky Blue
-C470
Yellow Green
-C490
Yellow Ocher
-C510
Pink
-C530
Beige
-C550
White
-C570
Silver
-C590
Black
-C610
Min.
(nm)
1444.5
1464.5
1484.5
1504.5
1524.5
1544.5
1564.5
1584.5
1604.5
Typ.
(nm)
1450
1470
1490
1510
1530
1550
1570
1590
1610
Max.
(nm)
1457.5
1477.5
1497.5
1517.5
1537.5
1557.5
1577.5
1597.5
1617.5
Clasp Color
Code
Yellow Orange
Gray
Violet
Blue
Green
Yellow
Orange
Red
Brown
CWDM*: 18 Wavelengths from 1270 nm to 1610 nm, each step 20 nm.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: [email protected] http: // www.optoway.com.tw
1/1/2008 V3.0
Optoway
SPS-93120F-CXX0G
2
***********************************************************************************************************************************************************************
Absolute Maximum Ratings
Parameter
Storage Temperature
Operating Case Temperature
Power Supply Voltage
Symbol
Tstg
Topr
Vcc
Min
-40
0
-5
-0.5
Max
85
70
85
3.6
Units
o
C
o
C
Min
3.13
0
-5
Typ
3.3
Max
3.47
70
85
300
Notes
SPS-93120F-CXX0G
SPS-93120BF-CXX0G
V
Recommended Operating Conditions
Parameter
Power Supply Voltage
Operating Case Temperature
Power Supply Current
Data Rate
Symbol
Vcc
Topr
ICC (TX+RX)
200
2125
1000
Units / Notes
V
o
C / SPS-93120F-CXX0G
o
C / SPS-93120BF-CXX0G
mA
Mb/s
Transmitter Specifications (0 oC < Topr < 70 oC, 3.13V < Vcc < 3.47V)
Parameter
Optical
Optical Transmit Power
Output Center Wavelength
Output Spectrum Width
Side Mode Suppression Ratio
Extinction Ratio
Optical Modulation Amplitude
(Peak-to-Peak)
Optical Rise Time
Optical Fall Time
Relative Intensity Noise
Dispersion Penalty
Electrical
Data Input Current – Low
Data Input Current – High
Differential Input Voltage
TX Disable Input Voltage – Low
TX Disable Input Voltage – High
TX Disable Assert Time
TX Disable Deassert Time
TX Fault Output Voltage -- Low
TX Fault Output Voltage -- High
Symbol
Min
Typ
Max
Units
Po
λ
∆λ
SMSR
ER
OMA
0
λc –5.5
--λc
5
λc +7.5
--30
---
1
9
---
dBm
nm
nm
dB
dB
µW
174
tr
tf
RIN
IIL
IIH
V IH - V IL
TDIS, L
TDIS, H
T ASSERT
TDEASSERT
TFaultL
TFaultH
160
160
-120
2.5
ps
ps
dB/Hz
dB
350
2.4
0.5
Vcc
10
1
0.5
Vcc+0.3
µA
µA
V
V
V
µs
ms
V
V
-350
0.5
0
2.0
0
2.0
Notes
1
2
-20 dB Width
FC-PI Standard
20 % to 80% Values
20 % to 80% Values
Peak-to-Peak
3
3
4
4
1. Output power is power coupled into a 9/125 µm single mode fiber.
2. ITU-T G.694.2 CWDM wavelength from 1470 nm to 1610 nm, each step 20 nm.
3. There is an internal 4.7K to 10K ohm pull-up resistor to VccTX.
4. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
Receiver Specifications (0oC < Topr < 70oC, 3.13V < Vcc < 3.47V)
Parameter
Symbol
Min
Typ
Max
Units
SENS (2X)
Pin
Pa
Pd
---9
---40
---
-30
---
-30
---
dBm
dBm
dBm
dBm
Notes
Optical
Sensitivity @2.125Gb/s @ BER=10-12
Maximum Input Power
Signal Detect -- Asserted
Signal Detect -- Deasserted
4
4
Transition: low to high
Transition: high to low
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: [email protected] http: // www.optoway.com.tw
1/1/2008 V2.0
Optoway
SPS-93120F-CXX0G
3
***********************************************************************************************************************************************************************
Signal detect -- Hysteresis
Wavelength of Operation
Electrical
Differential Output Voltage
Output LOS Voltage -- Low
Output LOS Voltage -- High
1.0
1260
V OH – VOL
VOL
VOH
-----
0.6
0
2.0
1620
dB
nm
2.0
0.5
Vcc+0.3
V
V
V
5
5
4. Measured at 2 7-1 PRBS at BER 1E-12.
5. Open collector compatible, 4.7K to 10K ohm pull-up to Vcc (Host Supply Voltage).
CONNECTION DIAGRAM
PIN
Signal Name
1
2
3
TX GND
TX Fault
TX Disable
4
MOD-DFE2
5
MOD-DEF1
6
MOD-DEF0
7
8
9
10
N/C
LOS
RX GND
RX GND
Description
PIN
Transmitter Ground
Transmitter Fault Indication
Transmitter Disable (Module disables
on high or open)
Modulation Definition 2 – Two wires
serial ID Interface
Modulation Definition 1 – Two wires
serial ID Interface
Modulation Definition 0 – Ground in
Module
Not Connected
Loss of Signal
Receiver Ground
Receiver Ground
11
12
13
RX GND
Receiver Ground
RX DATA OUT- Inverse Receiver Data Out
RX DATA OUT+ Receiver Data Out
Signal Name
Description
14
RX GND
Receiver Ground
15
Vcc RX
Receiver Power – 3.3V±5%
16
Vcc TX
Transmitter Power – 3.3V±5%
17
18
19
20
TX GND
TX DATA IN+
TX DATA INTX GND
Transmitter Ground
Transmitter Data In
Inverse Transmitter Data In
Transmitter Ground
Module Definition
Module Definition
MOD-DEF2
PIN 4
MOD-DEF1
PIN 5
MOD-DEF0
PIN 6
Interpretation by Host
4
SDA
SCL
LV-TTL Low
Serial module definition
protocol
Module Definition 4 specifies a serial definition protocol. For this definition, upon power up, MOD-DEF(1:2) appear as no connector
(NC) and MOD-DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol. The protocol uses the
2-wire serial CMOS E 2PROM protocol of the ATMEL AT24C01A/02/04 family of components.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: [email protected] http: // www.optoway.com.tw
1/1/2008 V2.0
Optoway
SPS-93120F-CXX0G
4
***********************************************************************************************************************************************************************
RECOMMENDED CIRCUIT SCHEMATIC
VeeT
Tx_DISABLE
Tx_FAULT
(1,17,20)
3
Tx_DISABLE
2
Tx_FAULT
4.7K to 10KΩ
TD +
LD
Driver
18
TD +
Z=50Ω
100Ω
TD -
19
TD Z=50Ω
VccT
1μH
16
Vcc 3.3V
10μF
10nF
10μF
10nF
SerDes
IC
1μH
VccR
15
10μF
10nF
RD -
12
Protocol
IC
RD Z=50Ω
100Ω
POST
Amp
RD +
13
RD +
Z=50Ω
4.7K to 10KΩ
LOS
VeeR
MOD_DEF(0)
EEPROM
MOD_DEF(1)
MOD_DEF(2)
SFP module
depending on SERDES
8
LOSS OF SINGAL
(9,10,11,14)
6
MODULE DETECT
5
SCL
4
SDA
4.7K to 10KΩ
4.7K to 10KΩ
Vcc 3.3V
4.7K to 10KΩ
PACKAGE DIAGRAM
Units in mm
Note: Specifications subject to change without notice.
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: [email protected] http: // www.optoway.com.tw
1/1/2008 V2.0
Optoway
SPS-93120F-CXX0G
5
***********************************************************************************************************************************************************************
Revision History
Version
1.0
2.0
3.0
Subject
Initial datasheet
Add 1270 to 1450 nm CWDM.
1. Revise package diagram for high port density use
2. Add clasp color codes for 18 wavelengths
Release Date
2004/1/1
2005/12/1
2008/1/1
***********************************************************************************************************************************************************************
OPTOWAY TECHNOLOGY INC. No.38, Kuang Fu S. Road, Hu Kou, Hsin Chu Industrial Park, Hsin Chu, Taiwan 303
Tel: 886-3-5979798
Fax: 886-3-5979737
E-mail: [email protected] http: // www.optoway.com.tw
1/1/2008 V2.0