MPD A515ERW

A500ERW Series
Low Cost, Wide Input, 5W
Single & Dual Output
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 5W Output Power
Parameter
• 2:1 Input Voltage Range
Input Start Voltage
• 1,500 VDC Isolation
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
• Compact DIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
• Low Cost
Conditions
Min.
12 VDC Input
4.5
24 VDC Input
8.0
π (Pi) Filter
Typ.
6.0
12.0
Max.
8.0
16.0
Units
1,000
1.0
3,000
A
mW
Typ.
±0.5
±0.5
±0.1
±0.3
50
Max.
±1.0
±2.0
±0.3
±1.0
75
100
15
150
±2.0
±0.01
Continuous (Autorecovery)
300
±6.0
±0.02
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/ºC
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Recovery Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Dual Output , Balanced Loads
Vin = Min to Max
Iout = 20% to 100%
Over Line, Load & Temp.
120
25% Load Step Change
General
RoHS Compliant
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,500
1,000
Typ.
Max.
380
300
500
Units
VDC
MΩ
pF
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-40
+25
-40
-40
Free Air Convection
RH, Non-condensing
Ambient
Case
Max.
+71
+90
+125
Units
ºC
ºC
ºC
95
%
Physical
Case Size
Case Material
Weight
1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm)
Non-Conductive Black Plastic (UL94-V0)
0.60 Oz (17g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
Typ.
1.0
Max.
Units
MHours
Conditions
12 VDC Input
24 VDC Input
1.5mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
Typ.
Max.
25.0
50.0
260
2,500
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
VDC
ºC
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
Voltage (VDC)
Input
Current (mA)
Nominal
Range
Full-Load
12
12
12
12
12
24
24
24
24
24
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
9.0 - 18.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
18.0 - 36.0
429
514
595
595
595
209
251
291
291
291
Output
Reflected
Efficiency
Current
Ripple Voltage Current
(%, Typ)
(VDC) (mA, Max) (mA, Min)
No-Load Current
Fuse Rating
Slow-Blow
(mA)
(mA, Typ)
A501ERW
A502ERW
A503ERW
A504ERW
A505ERW
A511ERW
A512ERW
A513ERW
A514ERW
A515ERW
20
20
20
20
20
5
5
5
5
5
25
25
25
25
25
15
15
15
15
15
3.3
5.0
12.0
±12.0
±15.0
3.3
5.0
12.0
±12.0
±15.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.47 µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units. For
noise sensitive applications, the use of 3.3 µF capacitors will reduce the
output ripple.
2. Transient recovery is measured to within a 1% error band for a load step
change of 75% to 100%.
3. Operation at no-load will not damage these units. However, they may not
meet all specifications.
4. Dual output units may be connected to provide a 10 VDC,
24 VDC or 30 VDC output. To do this, connect the load across the positive
(+Vout) and negative (-Vout) outputs and float the output common.
5. The converter should be connected to a low ac-impedance source. An
input source with a highly inductive impedance may affect the stability of
the converter. In applications where the converter output loading is high
and input power is supplied over long lines, it may be necessary to use a
capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz)
capacitor be mounted close to the converter. For 12V input units a 3.3 µF
is recommended and for 24V units a 2.2 µF.
6. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
1,200.0
1,000.0
500.0
±250.0
±200.0
1,200.0
1,000.0
500.0
±250.0
±200.0
60.0
50.0
25.0
±12.5
±10.0
60.0
50.0
25.0
±12.5
±10.0
77
81
84
84
84
79
83
86
86
86
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
2
-Vin
-Vin
3
-Vin
-Vin
9
No Pin
Common
11
NC
-Vout
14
+Vout
+Vout
16
-Vout
Common
22
+Vin
+Vin
23
+Vin
+Vin
NC: No Connection
Capacitive Load
Single Output
µF Max
Dual Output
µF Max
6,800
±1,000
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]