BOURNS 4B04B-523-RC

Features
■
■
■
■
Matched pair of resistors
Power line fault/lightning protection to
BELLCORE GR-1089
Typical application is secondary
protection on telecom line cards
Bourns TISP® products are recommended
for the overvoltage section of the
protection circuit
4B04B-523-RC - Line Protection Network
Matched Pair of Resistors
Electrical Characteristics
Product Dimensions
Resistance Values (R1 = R2)...............................................15Ω - 60Ω
Resistance Tolerance
>34Ω .........................................................................................±2%
<34Ω .........................................................................................±5%
TCR ...................................................................................100ppm/°C
Ratio Tolerance
>34Ω ......................................................................................±0.5%
<34Ω .........................................................................................±2%
Temperature Range.....................................................-40ºC to +85ºC
51.05
MAX.
(2.010)
12.19
(.480)
1
8.89
(.350)
Physical Characteristics
Body Style ................................................................Open Frame SIP
Substrate Material .........................................................96% Alumina
Lead Frame Material........................................Copper, solder coated
Flammability .....................................................Conforms to UL94V-0
Functional Characteristics (per Bellcore GR-1089)
1.52
(.060)
MAX.
4
11
7.62
(.300)
14
0.36
(.014)
MAX.
3.43 ± .381
(.135 ± .015)
17.78
(.700)
MM
(INCHES)
DIMENSIONS:
Electrical Schematic
First Level Lightning Surge Resistors will remain within tolerance after testing.
R1
1000 Volts Peak, 100 Amp Peak Current,
Max. Rise/Min. Decay Time 10x1000µs,
Number of Pulses ..............................25 each resistor each polarity
25 simultaneous each polarity
2500 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10µs,
Number of Pulses .............................10 simultaneous each polarity
1
600 Vrms, 1.0 Amp Short Circuit Current,
Duration ........................................................60 One-second pulses
11
14
100
10
TIME (Seconds)
100 Vrms, .17 Amp Short Circuit Current,
Duration...........................................................................15 minutes
4
Break Open Time
First Level AC Power Fault Resistors will remain within tolerance after testing.
50 Vrms, .33 Amp Short Circuit Current,
Duration...........................................................................15 minutes
R2
SINGLE RESISTOR
1
BOTH RESISTORS
SIMULTANEOUS
0.1
0.01
10
100
Second Level Lightning Surge Resistor package must fail safely causing no fire,
electrical, or framentation hazard.
1000
10000
POWER (Watts)
How To Order
5000 Volts Peak, 500 Amp Peak Current,
Max. Rise/Min. Decay Time 2x10µs,
Number of Pulses ...............................1 simultaneous each polarity
Number of Pins
Second Level AC Power Fault Resistor package must fail safely causing no fire,
electrical, or framentation hazard.
Physical Configuration
Electrical Configuration
• 523 = Matched Pair of Resistors
Standard Resistance Values
Resistance
(ohms)
Resistance
Code
20
40
50
200
400
500
Specifications are subject to change without notice.
4B 04 B - 523 - RC
Model
(4B = Open Frame)
Resistance Code
• First 2 digits are significant
• Third digit represents the number of zeros to follow
REV. A
COPYRIGHT© 2001, BOURNS, INC. LITHO IN U.S.A. IP 7/01 N0XXX