DIODES BAT1000

BAT1000
1A SURFACE MOUNT SCHOTTKY BARRIER RECTIFIER
Features
Mechanical Data
•
•
•
•
•
•
•
Very Low Forward Voltage Drop
High Conductance
For Use in DC-DC Converter, PCMCIA, and Mobile
Telecommunications Applications
Lead, Halogen and Antimony Free, RoHS Compliant "Green"
Device (Notes 1 and 2)
Qualified to AEC-Q101 Standards for High Reliability
•
•
•
•
Case: SOT-23
Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
Moisture Sensitivity: Level 1 per J-STD-020
Terminals: Matte Tin Finish annealed over Alloy 42 leadframe
(Lead Free Plating). Solderable per MIL-STD-202, Method 208
Polarity: See Diagram
Weight: 0.008 grams (approximate)
TOP VIEW
Schematic and Pin Configuration
Top View
Ordering Information (Note 3)
Part Number
BAT1000-7-F
Notes:
Case
SOT-23
Packaging
3000/Tape & Reel
1. No purposefully added lead. Halogen and Antimony Free.
2. Product manufactured with Data Code V9 (week 33, 2008) and newer are built with Green Molding Compound. Product manufactured prior to Date
Code V9 are built with Non-Green Molding Compound and may contain Halogens or Sb2O3 Fire Retardants.
3. For packaging details, go to our website at http://www.diodes.com.
Marking Information
YM
K79 = Product Type Marking Code
YM = Date Code Marking
Y = Year (ex: N = 2002)
M = Month (ex: 9 = September)
K79
Date Code Key
Year
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
Code
N
P
R
S
T
U
V
W
X
Y
Z
Month
Code
Jan
1
Feb
2
BAT1000
Document number: DS30245 Rev. 9 - 2
Mar
3
Apr
4
May
5
Jun
6
1 of 4
www.diodes.com
Jul
7
Aug
8
Sep
9
Oct
O
Nov
N
Dec
D
October 2010
© Diodes Incorporated
BAT1000
Maximum Ratings @TA = 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.
Characteristic
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
RMS Reverse Voltage
Average Rectified Current
Non-Repetitive Peak Forward Surge Current
8.3ms Single half sine-wave superimposed on rated load
Symbol
VRRM
VRWM
VR
VR(RMS)
IO
Value
Unit
40
V
28
1.0
V
A
IFSM
5.5
A
Symbol
PD
Value
500
Unit
mW
RθJA
200
°C/W
TJ
TSTG
-40 to +125
-40 to +150
°C
°C
Thermal Characteristics
Characteristic
Power Dissipation (Note 4)
Typical Thermal Resistance, Junction to Ambient Air
(Note 4)
Operating Temperature Range
Storage Temperature Range
Electrical Characteristics
Characteristic
Reverse Breakdown Voltage (Note 5)
Forward Voltage
@TA = 25°C unless otherwise specified
Symbol
V(BR)R
VF
Reverse Current (Note 5)
IR
Total Capacitance
CT
Notes:
Min
40
Typ
⎯
Max
⎯
Unit
V
⎯
225
235
290
340
390
420
475
270
290
340
400
450
500
600
mV
⎯
⎯
⎯
⎯
175
25
100
⎯
⎯
μA
pF
pF
Test Condition
IR = 300uA
IF = 50mA
IF = 100mA
IF = 250mA
IF = 500mA
IF = 750mA
IF = 1000mA
IF = 1500mA
VR = 30V
VR = 0V, f = 1.0MHz
VR = 25V, f = 1.0MHz
4. Part mounted on FR-4 board with recommended pad layout, which can be found on our website at http://www.diodes.com.
5. Short duration pulse test used to minimize self-heating effect.
BAT1000
Document number: DS30245 Rev. 9 - 2
2 of 4
www.diodes.com
October 2010
© Diodes Incorporated
1,000
10
CT, TOTAL CAPACITANCE (pF)
IF, INSTANTANEOUS FORWARD CURRENT (A)
BAT1000
1.0
0.1
0.01
0
1.0
0
TA, DERATED AMBIENT TEMPERATURE (ºC)
IO, AVERAGE RECTIFIED CURRENT (A)
Notes:
10
0.2
0.4
0.6
0.8
1.0
VF, INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 1 Typical Forward Characteristics
1.0
0.75
0.50
0.25
0
0
100
50
100
25
75
125
TT, TERMINAL TEMPERATURE (°C)
Fig. 3 Forward Current Derating Curve
10
15
20
25
5
VR, DC REVERSE VOLTAGE (V)
Fig. 2 Total Capacitance vs. Reverse Voltage
150
125
RθJA = 300°C/W
Note 6
100
150
75
50
25
1
20 30 40 50
10
VR, DC REVERSE VOLTAGE (V)
Fig. 4 Operating Temperature Derating
6. Assumed application thermal conditions. RθJA varies depending on application.
Package Outline Dimensions
A
B C
H
K
M
K1
D
J
F
G
BAT1000
Document number: DS30245 Rev. 9 - 2
L
3 of 4
www.diodes.com
SOT-23
Dim
Min
Max
Typ
A
0.37
0.51
0.40
B
1.20
1.40
1.30
C
2.30
2.50
2.40
D
0.89
1.03 0.915
F
0.45
0.60 0.535
G
1.78
2.05
1.83
H
2.80
3.00
2.90
J
0.013 0.10
0.05
K
0.903 1.10
1.00
K1
0.400
L
0.45
0.61
0.55
M
0.085 0.18
0.11
0°
8°
α
All Dimensions in mm
October 2010
© Diodes Incorporated
BAT1000
Suggested Pad Layout
Y
Z
C
X
Dimensions Value (in mm)
Z
2.9
X
0.8
Y
0.9
C
2.0
E
1.35
E
IMPORTANT NOTICE
DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
(AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION).
Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes
without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the
application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or
trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume
all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated
website, harmless against all damages.
Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel.
Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and
hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or
indirectly, any claim of personal injury or death associated with such unintended or unauthorized application.
Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings
noted herein may also be covered by one or more United States, international or foreign trademarks.
LIFE SUPPORT
Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express
written approval of the Chief Executive Officer of Diodes Incorporated. As used herein:
A. Life support devices or systems are devices or systems which:
1. are intended to implant into the body, or
2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the
labeling can be reasonably expected to result in significant injury to the user.
B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the
failure of the life support device or to affect its safety or effectiveness.
Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any
use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related
information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its
representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems.
Copyright © 2010, Diodes Incorporated
www.diodes.com
BAT1000
Document number: DS30245 Rev. 9 - 2
4 of 4
www.diodes.com
October 2010
© Diodes Incorporated