MCC 1N5400 THRU 1N5408 omponents 21201 Itasca Street Chatsworth !"# $ % !"# Features • • • • 3 Amp Rectifier 50 - 1000 Volts Low Current Leakage Metalurgically Bonded Construction Low Forward Voltage High Current Capability Maximum Ratings • • • DO-201AD Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Maximum Thermal Resistance; 30 °C/W Junction To Lead MCC Catalog Number Device Marking 1N5400 1N5401 1N5402 1N5404 1N5405 1N5406 1N5407 1N5408 ----------------- Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 500V 600V 800V 1000V Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 140V 280V 350V 420V 560V 700V 50V 100V 200V 400V 500V 600V 800V 1000V D A Cathode Mark B D C Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward IF(AV) 3.0A TA = 105°C Current Peak Forward Surge IFSM 200A 8.3ms, half sine Current Maximum 1.0V IFM = 3.0A; Instantaneous VF Forward Voltage TJ = 25°C* Maximum DC Reverse Current At IR 5.0µA TJ = 25°C Rated DC Blocking 50µA TJ = 125°C Voltage Typical Junction CJ 40pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse test: Pulse width 300 µsec, Duty cycle 2% DIMENSIONS DIM A B C D INCHES MIN ----.048 1.000 www.mccsemi.com MAX .370 .250 .052 --- MM MIN ----1.20 25.40 MAX 9.50 6.40 1.30 --- NOTE MCC 1N5400 thru 1N5408 Figure 1 Typical Forward Characteristics 20 Figure 2 Forward Derating Curve 10 3.0 6 4 2.5 2 Amps 2 1 .6 1.5 Amps .4 1.0 .2 25°C .5 .1 Single Phase, Half Wave 60Hz Resistive or Inductive Load .06 0 .04 0 50 75 100 125 150 175 °C .02 .01 .4 .6 .8 1.0 1.2 Average Forward Rectified Current - Amperesversus Ambient Temperature - °C 1.4 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 100 60 40 20 pF TJ=25°C 10 6 4 2 1 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 Junction Capacitance - pFversus Reverse Voltage - Volts www.mccsemi.com 1000 MCC 1N5400 thru 1N5408 Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 100 300 60 40 250 20 200 10 150 6 Amps 4 100 50 2 0 µAmps 1 .6 1 2 4 6 8 10 40 60 80 100 Cycles .4 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles .2 .1 20 TA=25°C .06 .04 .02 .01 20 40 60 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts www.mccsemi.com