CHENYI RL103

RL101
THRU
RL107
Shanghai Lunsure Electronic
Technology Co.,Ltd
Tel:0086-21-37185008
Fax:0086-21-57152769
Features
•
•
•
1 Amp Rectifier
50 - 1000 Volts
Low Current Leakage
Metalurgically Bonded Construction
Low Cost
Maximum Ratings
•
•
•
A-405
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Maximum Thermal Resistance; 50 °C/W Junction To Lead
Catalog
Number
RL101
RL102
RL103
RL104
RL105
RL106
RL107
Device
Marking
---------------
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
35V
70V
140V
280V
420V
560V
700V
50V
100V
200V
400V
600V
800V
1000V
D
A
Cathode
Mark
B
D
C
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
IF(AV)
1.0A
TA = 75°C
Current
Peak Forward Surge
IFSM
30A
8.3ms, half sine
Current
Maximum
1.1V
IFM = 1.0A;
Instantaneous
VF
Forward Voltage
TJ = 25°C*
Maximum DC
Reverse Current At
IR
5.0µA
TJ = 25°C
Rated DC Blocking
50µA
TJ = 125°C
Voltage
Typical Junction
CJ
15pF
Measured at
Capacitance
1.0MHz, VR=4.0V
*Pulse test: Pulse width 300 µsec, Duty cycle 2%
DIMENSIONS
DIM
A
B
C
D
INCHES
MIN
.166
.080
--1.000
www.cnelectr.com
MAX
.205
.107
.024
---
MM
MIN
4.10
2.00
--25.40
MAX
5.20
2.70
.60
---
NOTE
RL101 thru RL107
Figure 1
Typical Forward Characteristics
20
Figure 2
Forward Derating Curve
10
1.2
6
4
1.0
2
Amps
.8
1
.6
.6
Amps
.4
.4
.2
25°C
.2
.1
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.06
0
.04
0
50
75
100
125
150
175
°C
.02
.01
.4
.6
.8
1.0
1.2
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
100
60
40
20
pF
TJ=25°C
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
Junction Capacitance - pFversus
Reverse Voltage - Volts
www.cnelectr.com
400
1000
RL101 thru RL107
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
100
60
60
40
50
20
40
10
30
6
Amps
4 T =100°C
A
20
10
5
0
2
µAmps 1
1
2
4
6
.6
20
40
60 80 100
Cycles
.4
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
.2
.1
8 10
TA=25°C
.06
.04
.02
.01
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
www.cnelectr.com