RL101 THRU RL107 Shanghai Lunsure Electronic Technology Co.,Ltd Tel:0086-21-37185008 Fax:0086-21-57152769 Features • • • 1 Amp Rectifier 50 - 1000 Volts Low Current Leakage Metalurgically Bonded Construction Low Cost Maximum Ratings • • • A-405 Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Maximum Thermal Resistance; 50 °C/W Junction To Lead Catalog Number RL101 RL102 RL103 RL104 RL105 RL106 RL107 Device Marking --------------- Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 140V 280V 420V 560V 700V 50V 100V 200V 400V 600V 800V 1000V D A Cathode Mark B D C Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward IF(AV) 1.0A TA = 75°C Current Peak Forward Surge IFSM 30A 8.3ms, half sine Current Maximum 1.1V IFM = 1.0A; Instantaneous VF Forward Voltage TJ = 25°C* Maximum DC Reverse Current At IR 5.0µA TJ = 25°C Rated DC Blocking 50µA TJ = 125°C Voltage Typical Junction CJ 15pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse test: Pulse width 300 µsec, Duty cycle 2% DIMENSIONS DIM A B C D INCHES MIN .166 .080 --1.000 www.cnelectr.com MAX .205 .107 .024 --- MM MIN 4.10 2.00 --25.40 MAX 5.20 2.70 .60 --- NOTE RL101 thru RL107 Figure 1 Typical Forward Characteristics 20 Figure 2 Forward Derating Curve 10 1.2 6 4 1.0 2 Amps .8 1 .6 .6 Amps .4 .4 .2 25°C .2 .1 Single Phase, Half Wave 60Hz Resistive or Inductive Load .06 0 .04 0 50 75 100 125 150 175 °C .02 .01 .4 .6 .8 1.0 1.2 Average Forward Rectified Current - Amperesversus Ambient Temperature - °C 1.4 Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 100 60 40 20 pF TJ=25°C 10 6 4 2 1 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 Junction Capacitance - pFversus Reverse Voltage - Volts www.cnelectr.com 400 1000 RL101 thru RL107 Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 100 60 60 40 50 20 40 10 30 6 Amps 4 T =100°C A 20 10 5 0 2 µAmps 1 1 2 4 6 .6 20 40 60 80 100 Cycles .4 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles .2 .1 8 10 TA=25°C .06 .04 .02 .01 20 40 60 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts www.cnelectr.com