MCC omponents 21201 Itasca Street Chatsworth !"# $ % !"# MBR1520 THRU MBR15100 Features • • • • Metal of siliconrectifier, majonty carrier conducton Guard ring for transient protection Low power loss high efficiency High surge capacity, High current capability 15 Amp Schottky Barrier Rectifier 20 to 100 Volts Maximum Ratings • • Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Microsemi Catalog Number MBR1520 MBR1530 MBR1535 MBR1540 MBR1545 MBR1560 MBR1580 MBR15100 Device Marking MBR1520 MBR1530 MBR1535 MBR1540 MBR1545 MBR1560 MBR1580 MBR15100 Maximum Recurrent Peak Reverse Voltage 20V 30V 35V 40V 45V 60V 80V 100V TO-220AC Maximum RMS Voltage Maximum DC Blocking Voltage C B S F Q T 14V 21V 24.5V 28V 31.5 42V 56V 70V 20V 30V 35V 40V 45V 60V 80V 100V A U H K L D Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward Current IF(AV) 15A TC = 125°C Peak Forward Surge Current IFSM 150A 8.3ms, half sine Maximum Forward Voltage Drop Per Element MBR1520-1545 VF MBR1560 MBR1580-1500 Maximum DC Reverse Current At Rated DC Blocking Voltage .63V .75V .84V IFM = 16A mper IFM = 15 Amper TA = 25°C* IR 0.2 mA TJ = 25°C J R G A B C D F G H J K L Q R S T U INCHES .595 .620 .380 .405 .160 .190 .025 .035 .142 .147 .190 .210 .110 .130 .018 .025 .500 .562 .045 .060 .100 .120 .080 .110 .045 .055 .235 .255 -----.050 *Pulse test: Pulse width 300 µsec, Duty cycle 1% www.mccsemi.com MM 15.11 9.65 4.06 0.64 3.61 4.83 2.79 0.46 12.70 1.14 2.54 2.04 1.14 5.97 ----- 15.75 10.29 4.82 0.89 3.73 5.33 3.30 0.64 14.27 1.52 3.04 2.79 1.39 6.48 1.27 MCC MBR1520 thru MBR15100 Figure 1 Typical Forward Characteristics Figure 2 Typical Reverse Characteristics 10 100 MBR1560 60 6 4 40 2 20 MBR1520-1545 1 10 .6 6 .4 4 MBR1580-15100 .2 2 TJ=25°C 25°C µAmps .1 Amps 1 .06 .6 .04 .4 .02 .2 .01 .1 .006 .06 .00 4 .04 .002 .02 .01 .001 20 .2 .3 .4 .5 .6 .7 75 50 100 125 150 175 .8 Volts Volts Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts Figure 3 Forward Derating Curve Figure 4 Peak Forward Surge Current 15 150 13 125 11 100 75 9 Amps Amps 50 7 25 5 0 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 25 50 75 100 125 1 2 4 8 10 20 40 60 80 100 Cycles 150 °C 6 Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles Average Forward Rectified Current - Amperesversus Ambient Temperature - °C www.mccsemi.com