MCC RA255

MCC
Features
l
Plastic Material Used Carriers Underwrites Laboratory
Classification 94V-O
l
Low Cost Construction Utilizing Void-free Molded Plastic
Technique
l
High Surge Capability
l
Diffused Junction
RA251
THRU
RA257
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
25.0 Amp High
Current Plastic Silicon
Rectifier
50 to 1000 Volts
Maximum Ratings
o
RA
o
l
Operating & Storage Temperature: -50 C to +175 C
l
For Capacitive Load, Derate Current by 20%
A
RA251
RA252
RA253
RA254
RA255
Maximum
Recurrent
Peak
Reverse
Voltage
50V
100V
200V
400V
600V
RA256
800V
560V
800V
RA257
1000V
700V
1000V
MCC Part
Number
Maximum
RMS Voltage
Maximum
DC
Blocking
Voltage
35V
70V
140V
280V
420V
50V
100V
200V
400V
600V
Electrical Characteristics @ 25oC Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
E
C
D
B
o
IF(AV)
25.0A
T C =150 C
IFSM
400A
8.3ms half
sine
Maximum
Instantaneous
Forward Voltage
VF
1.1V
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR
5.0uA
Typical Reverse
Recovery Times
trr
3.0us
IF =0.5A,
IR =1.0A,
Irr=0.25A
Typical Junction
Capacitance
Cj
300pF
Measured at
1.0MHz,
V R=4.0V
IFM =25.0A
o
TA =25 C
T C =25 o C
DIMENSION
DIM INCHES
MM
NOTE
MIN MAX MIN MAX
A .380 .410 9.70 10.40
B .165 .185 4.19 4.70
C .215 .225 5.50 5.70
D .235 .250 6.00 6.40
E ----5o
----5o NOM
www.mccsemi.com
MCC
RA251 thru RA257
RATINGS AND CHARACTERISTIC CURVES
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
HALF SINE WAVE 60Hz
RESISTIVE OR
INDUCTIVE LOAD
40
30
20
10
0
125
135
145
155
165
FIG.2- MAXIMUM NON-REPETITIVE PEAK FORWARD
SURGE CURRENT
600
PEAK FORWARD SURGE CURRENT. (A)
AVERAGE FORWARD CURRENT. (A)
50
Tj=25 0C
Tj=150 0C
200
cycle
100
80
60
175
8.3ms Single Half Sine Wave
JEDEC Method
400
300
1
10
o
CASE TEMPERATURE. ( C)
100
NUMBER OF CYCLES AT 60Hz
FIG.3- TYPICAL FORWARD CHARACTERISTICS
FIG.4- TYPICAL REVERSE CHARACTERISTICS
1000
100
60
INSTANTANEOUS REVERSE CURRENT. ( A)
100
10
1.0
20
10
6
4
2
1
0.6
0.4
Tj=25 0C
0
Tj=25 C
PULSE WIDTH-300 S
2% DUTY CYCLE
0.1
0.6
1.0
1.4
1.8
2.2
0.2
0.1
2.6
FORWARD VOLTAGE. (V)
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
FIG.5- TYPICAL JUNCTION CAPACITANCE
1000
JUNCTION CAPACITANCE.(pF)
INSTANTANEOUS FORWARD CURRENT. (A)
40
500
Tj=25 0C
100
f=1.0MHz
Vsig=50mVp-p
50
1
2
5
10
REVERSE VOLTAGE. (V)
www.mccsemi.com
20
50
100