MCC Features • • • • SDB101 THRU SDB107 omponents 21201 Itasca Street Chatsworth !"# $ % !"# 1 Amp Single Phase Glass Passivated Bridge Rectifier 50 to 1000 Volts Surface Mount Package Glass Passivated Diode Construction Moisture Resistant Epoxy Case High Surge Current Capability Maximum Ratings • • SDB-1 Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C MCC Catalog Number Device Marking SDB101 SDB102 SDB103 SDB104 SDB105 SDB106 SDB107 --------------- Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V B Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V + ∼ ∼ D C K Notch in Case A G E H DIMENSIONS Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward IF(AV) 1A TA = 40°C Current Peak Forward Surge IFSM 50A 8.3ms, half sine Current Maximum 1.1V IFM = 1.0A; Instantaneous VF Forward Voltage TA = 25°C Maximum DC Reverse Current At IR 10µA TA = 25°C Rated DC Blocking 0.5mA TA = 125°C Voltage Maximum Reverse Trr 36ns IF=0.5A, IR=1.0A, Recovery Time Irr=0.25A Typical Junction CJ 25pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse Test: Pulse Width 300µsec, Duty Cycle 1% Version: 3 DIM A B C D E G H K INCHES MIN .320 .245 .040 .386 .120 .002 .195 .040 MAX .335 .255 .060 .404 .130 .008 .205 .047 MM MIN 8.13 6.20 1.02 9.80 3.05 0.05 5.00 1.02 MAX 8.50 6.50 1.52 10.3 3.30 0.20 5.20 1.20 NOTE TYP Suggested Solder Pad Layout .047” .344” .060” www.mccsemi.com .205” 2003/01/08 MCC SDB101 thru SDB107 Figure 1 Typical Forward Characteristics Figure 2 Typical Reverse Characteristics 20 100 60 10 40 6 20 4 10 2 6 25°C 1 4 .6 2 .4 µAmps 1 Amps .6 .2 .4 .1 .2 .06 .04 .06 .04 .02 .01 TA=25°C .1 .02 .4 .6 .8 1.0 1.2 1.4 Volts .01 20 40 60 Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperesversus Percent Of Rated Peak Reverse Voltage - Volts Figure 3 Forward Derating Curve Figure 4 Peak Forward Surge Current 1.2 60 1.0 50 40 .8 30 .6 Amps Amps .4 20 10 5 0 .2 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 0 50 75 100 125 1 2 4 6 8 10 20 40 60 80 100 Cycles 150 175 °C Peak Forward Surge Current - Amperesversus Number Of Cycles At 60Hz - Cycles Average Forward Rectified Current - Amperesversus Ambient Temperature - °C Version: 3 www.mccsemi.com 2003/01/08