MCC UF5406GP

MCC
UF5400GP
THRU
UF5408GP
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
Features
•
•
•
•
3 Amp Ultra Fast
Glass Passivated
Recovery Rectifier
50 to 1000 Volts
High Surge Capability
Glass Passivated Junction
Low Forward Voltage Drop
Ultra Fast Switching Speed For High Efficiency
Maximum Ratings
•
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Typical Thermal Resistance 20°C/W
MCC
Device
Maximum
Maximum
Catalog
Marking
Recurrent
RMS
Number
Peak Reverse
Voltage
Voltage
UF5400GP
--50V
35V
UF5401GP
--100V
70V
UF5402GP
--200V
140V
UF5404GP
--400V
280V
UF5406GP
--600V
420V
UF5407GP
--800V
560V
UF5408GP
--1000V
700V
DO-201AD
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
400V
800V
1000V
D
A
Cathode
Mark
B
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
IF(AV)
3A
TA = 55°C
Current
Peak Forward Surge
IFSM
150A
8.3ms, half sine
Current
Maximum
Instantaneous
Forward Voltage
1.0V
IFM = 3.0A;
UF5400GP-5402GP
VF
1.3V
UF5404GP
TA = 25°C
1.7V
UF5406GP-5408GP
Maximum DC
Reverse Current At
IR
10µA
TA = 25°C
Rated DC Blocking
50µA
TA = 100°C
Voltage
Maximum Reverse
Recovery Time
50ns
IF=0.5A, IR=1.0A,
UF5400GP-5404GP
Trr
75ns
Irr=0.25A
UF5406GP-5408GP
Typical Junction
Capacitance
75pF
Measured at
UF5400GP-5404GP
CJ
50pF
1.0MHz, VR=4.0V
UF5406GP-5408GP
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
D
C
DIMENSIONS
DIM
A
B
C
D
INCHES
MIN
----.048
1.000
MAX
.370
.250
.052
---
www.mccsemi.com
MM
MIN
----1.20
25.40
MAX
9.50
6.40
1.30
---
NOTE
MCC
UF5400GP thru UF5408GP
Figure 1
Typical Forward Characteristics
20
Figure 2
Forward Derating Curve
10
3.0
6
4
2.5
UF5400GP - UF5404GP
2
25°C
Amps
2.0
1
.6
1.5
Amps
.4
1.0
.2
UF5406GP - UF5408GP
.1
.5
Single Phase, Half Wave
60Hz Resistive or Inductive Load
.06
0
.04
50
75
100
125
175
.4
.6
.8
1.0
1.2
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
1.4
Volts
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
UF5400GP - UF5404GP
100
60
40
UF5406GP - UF5408GP
20
pF
150
°C
.02
.01
0
TJ=25°C
10
6
4
2
1
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
Junction Capacitance - pFversus
Reverse Voltage - Volts
www.mccsemi.com
1000
MCC
UF5400GP thru UF5408GP
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
100
150
60
40
TJ=150°C
125
20
100
10
75
6
Amps
4 TJ=100°C
50
25
2
0
µAmps 1
1
4
2
.6
.4
6
8 10
20
40
60 80 100
Cycles
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
TJ=25°C
.2
.1
.06
.04
.02
.01
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
50Ω
10Ω
trr
+0.5A
0
Pulse
Generator
Note 2
25Vdc
1Ω
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
Oscilloscope
Note 1
-0.25
-1.0
1cm
Set Time Base for 20/100ns/cm
www.mccsemi.com