MICREL SY100E337JCTR

3-BIT SCANNABLE
REGISTERED BUS
TRANSCEIVER
FEATURES
The SY10/100E337 are 3-bit registered bus transceivers
with scan designed for use in new, high- performance ECL
systems. The bus outputs (BUS0–BUS2) are designed to
drive a 25Ω bus; the receive outputs (Q0–Q2) are designed
for 50Ω. The bus outputs feature a normal logic HIGH level
(VOH) and a cutoff LOW level of –2.0V and the output
emitter-follower is “off”, presenting a high impedance to the
bus. The bus outputs also feature edge slow-down
capacitors.
Both drive and receive sides feature the same logic,
including a loopback path to hold data. The LOAD/HOLD
function is controlled by Transmit Enable (TEN) and Receive
Enable (REN) on the transmit and receive sides,
respectively, with a HIGH selecting LOAD. The
implementation of the E337 Receive Enable differs from
that of the E336.
A synchronous bus enable (SBUSEN) is provided for
normal, non-scan operation. The asynchronous bus disable
(ABUSDIS) disables the bus for scan mode.
The SYNCEN input allows either synchronous or
asynchronous re-enabling after disabling with ABUSDIS.
An alternative use is asynchronous-only operation with
ABUSDIS, in which case SYNCEN is tied LOW. SYNCEN
is implemented as an overriding SET control to the enable
flip-flop.
Scan mode is selected by a logic HIGH at the SCAN
input. Scan input data is shifted in through S-IN, and output
data appears at the Q2 output.
All registers are clocked on the rising edge of CLK.
Additional lead-frame grounding is provided through the
ground pins (GND) which should be connected to 0V. The
GND pins are not electrically connected to the chip.
Q0
VCCO
B0
A0
ABUSDIS
PIN CONFIGURATION
SBUSEN
SYNCEN
25 24 23 22 21 20 19
18
27
17
28
TOP VIEW
PLCC
J28-1
1
2
16
15
14
3
13
4
12
5
6
7
8
9
GND
BUS0
VCC
Q1
PIN NAMES
Pin
VCCO
BUS1
GND
A0–A2
10 11
GND
Q2
REN
CLK
A1
26
BUS2
SCAN
S-IN
TEN
VEE
VCCO
■
■
■
1500ps max. clock to bus (data transmit)
1000ps max. clock to Q (data receive)
Extended 100E VEE range of –4.2V to –5.5V
25Ω cutoff bus outputs
50Ω receiver outputs
Scannable implementation of E336
Synchronous and asynchronous bus enables
Non-inverting data path
Bus outputs feature internal edge slow-down
capacitors
Additional package ground pins
Fully compatible with industry standard 10KH,
100K ECL levels
Internal 75KΩ input pulldown resistors
Fully compatible with Motorola MC10E/100E337
Available in 28-pin PLCC package
B1
■
■
DESCRIPTION
A2
B2
■
■
■
■
■
■
■
■
■
SY10E337
SY100E337
Function
Data Inputs A
B0–B2
Data Inputs B
S-IN
Serial (Scan) Data Input
TEN, REN
LOAD/HOLD Controls
SCAN
Scan Control
ABUSDIS
Asynchronous Bus Disable
SBUSEN
Synchronous Bus Enable
SYNCEN
Synchronous Enable Control
CLK
Clock
BUS0–BUS2
25Ω Cutoff BUS Outputs
Q0–Q2
Receive Data Outputs (Q2 serves as
SCAN_OUT in scan mode)
VCCO
VCC to Output
Rev.: C
1
Amendment: /2
Issue Date: February, 1998
SY10E337
SY100E337
Micrel
BLOCK DIAGRAM
BUS2
D
D
Q
Q
A2
B2
Q2
SCAN-OUT
BUS1
D
D
Q
Q
Q1
A1
B1
BUS0
D
Q
SBUSEN
D
Q
SYNCEN
SET
D
A0
B0
S-IN
TEN
REN
SCAN
ABUSDIS
CLK
2
Q
Q0
SY10E337
SY100E337
Micrel
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
Min.
VCUT
Cut-off Output Voltage
IIH
Input HIGH Current
All Other Inputs
IEE
Power Supply Current
10E
100E
TA = +25°C
Typ. Max. Min. Typ. Max.
–2.03 –2.10
—
TA = +85°C
Min. Typ.
–2.03 –2.10
Max.
Unit
Condition
—
–2.03
V
1
µA
—
mA
—
Unit
Condition
ps
—
ps
—
ps
—
ps
—
ps
—
–2.10
—
—
—
150
—
—
150
—
—
150
—
—
145
145
174
174
—
—
145
125
174
174
—
—
145
167
174
200
NOTE:
1. Applies to BUS outputs only. Measured with VTT = –2.10V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
Parameter
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ. Max.
Min. Typ.
Max.
tPLH
tPHL
Propagation Delay to Output
CLK to Q
CLK to BUS
ABUSDIS
SYNCEN
450
800
500
800
—
—
—
—
1000
1800
1500
1800
450
800
500
800
—
—
—
—
1000
1800
1500
1800
450
800
500
800
—
—
—
—
1000
1800
1500
1800
tS
Set-up Time
BUS
SBUSEN
Data, S-IN
TEN, REN, SCAN
350
100
400
550
—
—
—
—
—
—
—
—
350
100
400
550
—
—
—
—
—
—
—
—
350
100
400
550
—
—
—
—
—
—
—
—
Hold Time
BUS
SBUSEN
Data, S-IN
TEN, REN, SCAN
350
500
350
200
—
—
—
—
—
—
—
—
350
500
350
200
—
—
—
—
—
—
—
—
350
500
350
200
—
—
—
—
—
—
—
—
tPW
Minimum Pulse Width
400
—
—
400
—
—
400
—
—
tr
tf
Rise/Fall Time
20% to 80% (Qn)
20% to 80% (BUSn Rise)
20% to 80% (BUSn Fall)
300
500
300
—
—
—
800
1000
800
300
500
300
—
—
—
800
1000
800
300
500
300
—
—
—
800
1000
800
tH
PRODUCT ORDERING CODE
Ordering
Code
Package
Type
Operating
Range
SY10E337JC
J28-1
Commercial
SY10E337JCTR
J28-1
Commercial
SY100E337JC
J28-1
Commercial
SY100E337JCTR
J28-1
Commercial
3
SY10E337
SY100E337
Micrel
28 LEAD PLCC (J28-1)
Rev. 03
MICREL-SYNERGY
TEL
3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA
+ 1 (408) 980-9191
FAX
+ 1 (408) 914-7878
WEB
http://www.micrel.com
This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or
other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc.
© 2000 Micrel Incorporated
4