SmartMediaTM K9S1208V0M-SSB0 Document Title 64M x 8 Bit SmartMediaTM Card Revision History Revision No History Draft Date Remark 0.0 Initial issue Mar. 30th 2001 preliminary 0.1 1. Changed DC characteristics Apr. 7th 2001 Final Parameter Operating Current Min Typ Max Sequential Read - 10 20->30 Program - 10 20->30 Erase - 10 20->30 Unit mA 2. Added t DBSY parameter 3. Removed Copy-Back program command 4. Changed AC characteristics Parameter ALE to RE Delay ( ID read ) Symbol Min Max Unit tAR1 100->10 - ns Note : For more detailed features and specifications including FAQ, please refer to Samsung’s Flash web site. http://www.intl.samsungsemi.com/Memory/Flash/datasheets.html The attached data sheets are prepared and approved by SAMSUNG Electronics. SAMSUNG Electronics CO., LTD. reserve the right to change the specifications. SAMSUNG Electronics will evaluate and reply to your requests and questions about device. If you have any questions, please contact the SAMSUNG branch office near your office. 1 SmartMediaTM K9S1208V0M-SSB0 64M x 8 Bit SmartMediaTM Card FEATURES GENERAL DESCRIPTION •Single 2.7V~3.6V Supply •Organization - Memory Cell Array : (64M + 2,048K)bit x 8bit - Data Register : (512 + 16)bit x8bit •Automatic Program and Erase - Page Program : (512 + 16)Byte - Block Erase : (16K + 512)Byte •528-Byte Page Read Operation - Random Access : 12µs(Max.) - Serial Page Access : 50ns(Min.) •Fast Write Cycle Time - Program Time : 200µs(Typ.) - Block Erase Time : 2ms(Typ.) •Command/Address/Data Multiplexed I/O Port •Hardware Data Protection - Program/Erase Lockout During Power Transitions •Reliable CMOS Floating-Gate Technology - Endurance : 100K Program/Erase Cycles - Data Retention : 10 Years •Command Register Operation •22pad SmartMediaTM (SSFDC) •ID for Copyright Protection The K9S1208V0M is a 64M(67,108,864)x8bit NAND Flash Memory with a spare 2,048K(2,097,152)x8bit. Its NAND cell provides the most cost-effective solution for the solid state mass storage market. A program operation programs the 528byte page in typically 200µs and an erase operation can be performed in typically 2ms on a 16K-byte block. Data in the page can be read out at 50ns cycle time per byte. The I/O pins serve as the ports for address and data input/output as well as command inputs. The on-chip write controller automates all program and erase functions including pulse repetition, where required, and internal verify and margining of data. n, where required, and internal verify and margining of data. Even the write-intensive systems can take advantage of the K9S1208V0M′s extended reliability of 100K program/erase cycles by providing ECC(Error Correcting Code) with real time mapping-out algorithm. The K9S1208V0M is an optimum solution for large nonvolatile storage applications such as solid state file storage, digital voice recorder, digital still camera and other portable applications requiring non-volatility. SmartMediaTM CARD(SSFDC) PIN DESCRIPTION Pin Name 22 VCC 12 22 I/O0 ~ I/O7 1 Pin Function Data Input/Outputs VSS CLE Command Latch Enable 21 CE 2 CLE 20 RE 3 ALE ALE Address Latch Enable 19 R/B 4 WE CE Chip Enable 5 WP 6 I/O0 RE Read Enable 7 I/O1 WE Write Enable 8 I/O2 WP Write Protect 14 I/O5 9 I/O3 13 I/O4 10 VSS 12 VCC 11 VSS 18 GND 17 LVD 16 I/O7 15 I/O6 11 1 ID 64MB 22 PAD SmartMediaTM LVD Low Voltage Detect GND Ground R/B Ready/Busy output VCC Power VSS Ground N.C No Connection NOTE : Connect all VCC and V SS pins of each device to common power supply outputs. Do not leave VCC or V SS disconnected. 2 SmartMediaTM K9S1208V0M-SSB0 Figure 1. FUNCTIONAL BLOCK DIAGRAM VCC VSS A9 - A25 X-Buffers Latches & Decoders A0 - A7 Y-Buffers Latches & Decoders 512M + 16M Bit NAND Flash ARRAY (512 + 16)Byte x 131,072 Page Register & S/A A8 Y-Gating Command Command Register CE RE WE VCC VSS I/O Buffers & Latches Control Logic & High Voltage Generator Output Driver Global Buffers I/0 0 I/0 7 CLE ALE WP Figure 2. ARRAY ORGANIZATION 1 Block = 32 Pages (16K + 512) Byte 128K Pages (=4,096 Blocks) 1st half Page Register 2nd half Page Register (=256 Bytes) (=256 Bytes) 1 Page = 528 Byte 1 Block = 528 Byte x 32 Pages = (16K + 512) Byte 1 Device = 528Byte x 32Pages x 4096 Blocks = 528 Mbits 8 bit 512B Byte 16 Byte I/O 0 ~ I/O 7 Page Register 512 Byte 1st Cycle 16 Byte I/O 0 I/O 1 I/O 2 I/O 3 I/O 4 I/O 5 I/O 6 I/O 7 A0 A1 A2 A3 A4 A5 A6 A7 2nd Cycle A9 A10 A11 A12 A13 A14 A15 A16 3rd Cycle A17 A18 A19 A20 A21 A22 A23 A24 4th Cycle A25 *L *L *L *L *L *L *L NOTE : Column Address : Starting Address of the Register. 00h Command(Read) : Defines the starting address of the 1st half of the register. 01h Command(Read) : Defines the starting address of the 2nd half of the register. * A8 is set to "Low" or "High" by the 00h or 01h Command. * L muxt be set to "Low". 3 Column Address Row Address (Page Address) SmartMediaTM K9S1208V0M-SSB0 Product Introduction The K9S1208V0M is a 528Mbit(553,648,218 bit) memory organized as 131,072 rows(pages) by 528 columns. Spare sixteen columns are located from column address of 512 to 527. A 528-byte data register is connected to memory cell arrays accommodating data transfer between the I/O buffers and memory during page read and page program operations. The memory array is made up of 16 cells that are serially connected to form a NAND structure. Each of the 16 cells resides in a different page. A block consists of the 32 pages formed by two NAND structures, totaling 8,192 NAND structures of 16 cells. The array organization is shown in Figure 2. The program and read operations are executed on a page basis, while the erase operation is executed on a block basis. The memory array consists of 4,096 separately erasable 16K-byte blocks. It indicates that the bit by bit erase operation is prohibited on the K9S1208V0M. The K9S1208V0M has addresses multiplexed into 8 I/O's. This scheme dramatically reduces pin counts and allows systems upgrades to future densities by maintaining consistency in system board design. Command, address and data are all written through I/O's by bringing WE to low while CE is low. Data is latched on the rising edge of WE. Command Latch Enable(CLE) and Address Latch Enable(ALE) are used to multiplex command and address respectively, via the I/O pins. The 64M byte physical space requires 26 addresses, thereby requiring four cycles for byte-level addressing: column address, low row address and high row address, in that order. Page Read and Page Program need the same four address cycles following the required command input. In Block Erase operation, however, only the three row address cycles are used. Device operations are selected by writing specific commands into the command register. Table 1 defines the specific commands of the K9S1208V0M. The device provides simultaneous program/erase capability up to four pages/blocks. By dividing the memory array into four 128Mbit separate planes, simultaneous multi-plane operation dramatically increases program/erase performance by 4X while still maintaining the conventional 512 byte structure. The extended pass/fail status for multi-plane program/erase allows system software to quickly identify the failing page/block out of selected multiple pages/blocks. Usage of multi-plane operations will be described further throughout this document. Table 1. Command Sets Function Read 1 1st. Cycle 2nd. Cycle 3rd. Cycle Acceptable Command - - Read 2 50h - - Read ID (1) 90h - - Read ID (2) 91h - - Reset FFh - - Page Program (True) 80h 10h - Page Program (Dummy) 80h 11h - Page Program (Multi Block Program) 80h 15h - Block Erase 60h D0h - 60h---60h D0h - 70h - - O - - O (1) 00h/01h Multi-Plane Block Erase Read Status Read Multi-Plane Status 71h (2) NOTE : 1. The 00h command defines starting address of the 1st half of registers. The 01h command defines starting address of the 2nd half of registers. After data access on the 2nd half of register by the 01h command, the status pointer is automatically moved to the 1st half register(00h) on the next cycle. 4 O SmartMediaTM K9S1208V0M-SSB0 Memory Map The device is arranged in four 128Mbit memory planes. Each plane contains 1,024 blocks and 528 byte page registers. This allows it to perform simultaneous page program and block erase by selecting one page or block from each plane. The block address map is configured so that multi-plane program/erase operations can be executed for every four sequential blocks. Figure 3. Memory Array Map Plane 0 (1024 Block) Block 0 Plane 2 (1024 Block) Plane 1 (1024 Block) Block 2 Block 1 Plane 3 (1024 Block) Block 3 Page 0 Page 0 Page 0 Page 0 Page 1 Page 1 Page 1 Page 1 Page 30 Page 30 Page 30 Page 30 Page 31 Page 31 Page 31 Page 31 Block 4 Block 6 Block 5 Block 7 Page 0 Page 0 Page 0 Page 0 Page 1 Page 1 Page 1 Page 1 Page 30 Page 30 Page 31 Page 30 Page 30 Page 31 Page 31 Page 31 Block 4088 Page 0 Block 4090 Block 4089 Block 4091 Page 0 Page 0 Page 0 Page 1 Page 1 Page 1 Page 1 Page 30 Page 30 Page 30 Page 30 Page 31 Page 31 Page 31 Page 31 Block 4092 Block 4094 Block 4093 Block 4095 Page 0 Page 0 Page 0 Page 0 Page 1 Page 1 Page 1 Page 1 Page 30 Page 30 Page 31 Page 30 Page 30 Page 31 Page 31 Page 31 528byte Page Registers 528byte Page Registers 528byte Page Registers 5 528byte Page Registers SmartMediaTM K9S1208V0M-SSB0 PIN DESCRIPTION Command Latch Enable(CLE) The CLE input controls the path activation for commands sent to the command register. When active high, commands are latched into the command register through the I/O ports on the rising edge of the WE signal. Address Latch Enable(ALE) The ALE input controls the activating path for address to the internal address registers. Addresses are latched on the rising edge of WE with ALE high. Chip Enable(CE) The CE input is the device selection control. When CE goes high during a read operation the device is returned to standby mode. However, when the device is in the busy state during program or erase, CE high is ignored, and does not return the device to standby mode. Write Enable(WE) The WE input controls writes to the I/O port. Commands, address and data are latched on the rising edge of the WE pulse. The WE must be held high when outputs are activated. Read Enable(RE) The RE input is the serial data-out control, and when active drives the data onto the I/O bus. Data is valid tREA after the falling edge of RE which also increments the internal column address counter by one. I/O Port : I/O 0 ~ I/O 7 The I/O pins are used to input command, address and data, and to output data during read operations. The I/O pins float to high-z when the chip is deselected or when the outputs are disabled. Write Protect(WP) The WP pin provides inadvertent write/erase protection during power transitions. The internal high voltage generator is reset when the WP pin is active low. Ready/Busy(R/B) The R/B output indicates the status of the device operation. When low, it indicates that a program, erase or random read operation is in process and returns to high state upon completion. It is an open drain output and does not float to high-z condition when the chip is deselected or when outputs are disabled. Low Voltage Detect(LVD) The LVD is used to electrically detect the proper supply voltage. By connecting this pin to Vss through a pull-down resister, it is possible to distinguish 3.3V product from 5V product. When 3.3V is applied as Vcc to pins 12 and 22, a ’High’level can be detected on the system side if the device is a 3.3V product, and ’Low’level for 5V product. 6 SmartMediaTM K9S1208V0M-SSB0 ABSOLUTE MAXIMUM RATINGS Parameter Symbol Rating Unit VIN -0.6 to + 4.6 VCC -0.6 to + 4.6 Temperature Under Bias TBIAS -10 to +65 °C Storage Temperature TSTG -20 to +65 °C Voltage on any pin relative to VSS V NOTE : 1. Minimum DC voltage is -0.3V on input/output pins. During transitions, this level may undershoot to -2.0V for periods <30ns. Maximum DC voltage on input/output pins is V CC+0.3V which, during transitions, may overshoot to VCC+2.0V for periods <20ns. 2. Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS are exceeded. Functional operation should be restricted to the conditions as detailed in the operational sections of this data sheet. Exposure to absolute maximum rating conditions for extended periods may affect reliability. RECOMMENDED OPERATING CONDITIONS (Voltage reference to GND, T A=0 to 55°C) Parameter Symbol Min Typ. Max Unit Supply Voltage VCC 2.7 3.3 3.6 V Supply Voltage VSS 0 0 0 V DC AND OPERATING CHARACTERISTICS(Recommended operating conditions otherwise noted.) Parameter Operating Current Symbol Test Conditions tRC=50ns, CE=VIL, IOUT=0mA Min Typ Max Sequential Read ICC1 - 10 30 Program ICC2 - - 10 30 Erase ICC3 - - 10 30 1 Stand-by Current(TTL) ISB1 CE=VIH, WP=0V/VCC - - Stand-by Current(CMOS) ISB2 CE=VCC-0.2, WP=0V/V CC - 10 50 Input Leakage Current ILI VIN=0 to 3.6V - - ±10 Output Leakage Current ILO VOUT=0 to 3.6V - - ±10 Input High Voltage, All inputs VIH - 2.0 - VCC+0.3 - -0.3 - 0.8 2.4 - - Input Low Voltage, All inputs VIL Output High Voltage Level VOH IOH=-400µA Output Low Voltage Level VOL IOL=2.1mA - - 0.4 Output Low Current(R/B) IOL(R/B) VOL=0.4V 8 10 - 7 Unit mA µA V mA SmartMediaTM K9S1208V0M-SSB0 VALID BLOCK Parameter Valid Block Number Symbol Min Typ. Max Unit N VB 4026 - 4096 Blocks NOTE : 1. The K9S1208V0M may include invalid blocks when first shipped. Additional invalid blocks may develop while being used. The number of valid blocks is presented with both cases of invalid blocks considered. Invalid blocks are defined as blocks that contain one or more bad bits . Do not try to access these invalid blocks for program and erase. Refer to the attached technical notes for a appropriate management of invalid blocks. 2. Per the specification of the physical format version 1.2 by SSFDC forum, minimum 1,000 vaild blocks are guaranteed for each 16MB memory space. AC TEST CONDITION (TA=0 to 55°C, VCC=2.7V~3.6V unless otherwise noted) Parameter Value Input Pulse Levels 0.4V to 2.4V Input Rise and Fall Times 5ns Input and Output Timing Levels 1.5V Output Load (3.0V +/-10%) 1 TTL GATE and CL=50pF Output Load (3.3V +/-10%) 1 TTL GATE and CL=100pF CAPACITANCE(TA=25°C, VCC=3.3V, f=1.0MHz) Item Symbol Test Condition Min Max Unit Input/Output Capacitance CI/O VIL =0V - 10 pF Input Capacitance CIN VIN=0V - 10 pF NOTE : Capacitance is periodically sampled and not 100% tested. MODE SELECTION CLE ALE CE RE WP H L L WE H X L H L H X Address Input(4clock) H L L H H Command Input L H L H H L L L H H Data Input L L L H X sequential Read & Data Output L L L H H X During Read(Busy) X X X X X H During Program(Busy) X X X X X H During Erase(Busy) X X(1) X X X L Write Protect X X H X X 0V/V CC (2) Mode Read Mode Write Mode Command Input Address Input(4clock) Stand-by NOTE : 1. X can be V IL or VIH. 2. WP should be biased to CMOS high or CMOS low for standby. Program / Erase Characteristics Parameter Symbol Min Typ Max Unit Program Time tPROG - 200 500 µs Dummy Busy Time for Multi Plane Program tDBSY 1 10 µs - - 1 cycle - - 2 cycles - 2 3 ms Number of Partial Program Cycles in the Same Page Block Erase Time Main Array Spare Array Nop tBERS 8 SmartMediaTM K9S1208V0M-SSB0 AC Timing Characteristics for Command / Address / Data Input Parameter Symbol Min Max Unit CLE setup Time tCLS 0 - ns CLE Hold Time tCLH 10 - ns CE setup Time tCS 0 - ns CE Hold Time tCH 10 - ns WE Pulse Width tWP 25(1) - ns ALE setup Time tALS 0 - ns ALE Hold Time tALH 10 - ns Data setup Time tDS 20 - ns Data Hold Time tDH 10 - ns Write Cycle Time tWC 50 - ns WE High Hold Time tWH 15 - ns NOTE : 1. If tCS is set less than 10ns, tWP must be minimum 35ns, otherwise, tWP may be minimum 25ns. AC Characteristics for Operation Parameter Symbol Min Max Unit tR - 12 µs Data Transfer from Cell to Register ALE to RE Delay( ID read ) tAR1 10 - ns ALE to RE Delay(Read cycle) tAR2 50 - ns Ready to RE Low tRR 20 - ns RE Pulse Width tRP 30 - ns WE High to Busy tWB - 100 ns Read Cycle Time tRC 50 - ns RE Access Time tREA - 35 ns RE High to Output Hi-Z tRHZ 15 30 ns CE High to Output Hi-Z tCHZ - 20 ns RE High Hold Time tREH 15 - ns Output Hi-Z to RE Low tIR 0 - ns Last RE High to Busy(at sequential read) tRB - 100 CE High to Ready(in case of interception by CE at read) tCRY - CE High Hold Time(at the last serial read) (2) tCEH 100 - ns ns 50 +tr(R/B) CE Access Time tCEA - 45 WE High to RE Low tWHR 60 - Device Resetting Time(Read/Program/Erase) tRST - NOTE : 1. The time to Ready depends on the value of the pull-up resistor tied R/B pin. 2. To break the sequential read cycle, CE must be held high for longer time than tCEH. 3. If reset command(FFh) is written at Ready state, the device goes into Busy for maximum 5us. 9 ns 5/10/500 (1) ns ns (3) µs SmartMediaTM K9S1208V0M-SSB0 SmartMedia Technical Notes Invalid Block(s) Invalid blocks are defined as blocks that contain one or more invalid bits whose reliability is not guaranteed by Samsung. The information regarding the invalid block(s) is so called as the invalid block information. An invalid block(s) does not affect the performance of valid block(s) because it is isolated from the bit line and the common source line by a select transistor. The system design must be able to mask out the invalid block(s) via address mapping. Identifying Invalid Block(s) SSFDC Forum specifies the logical format and physical format to ensure compatibility of SmartMedia. Samsung pre-formats SmartMedia in the Forum-compliant format prior to shipping. Physical format standard by SSFDC Forum specifies that for the invalid blocks the 6th byte in the spare area (column address 517 for 4MB SmartMedia and higher densities, 261 for 2MB SmartMedia, respectively) contains two or more "0" bits to indicate a invalid block. Other than the blocks with format data and the invalid blocks are erased(FFh). Since the invalid block information is also erasable in most cases, it is impossible to recover the information once it has been erased. Therefore, the system must be able to recognize the invalid block(s) based on the original invalid block information and create the invalid block table via the following suggested flow chart(Figure 4). Any intentional erasure of the original invalid block information is prohibited. Start Set Block Address = 0 Increment Block Address Create (or update) Invalid Block(s) Table No * Check "FFh" at the column address 517 (or 261) of the first page in the block Check "FFh" ? Yes No Last Block ? Yes End Figure 4. Flow chart to create invalid block table. 10 SmartMediaTM K9S1208V0M-SSB0 SmartMedia Technical Notes (Continued) Error in write or read operation Over its life time, the additional invalid blocks may develop with NAND Flash memory. Refer to the qualification report for the actual data.The following possible failure modes should be considered to implement a highly reliable system. In the case of status read failure after erase or program, block replacement should be done. To improve the efficiency of memory space, it is recommended that the read or verification failure due to single bit error be reclaimed by ECC without any block replacement. The said additional block failure rate does not include those reclaimed blocks. Failure Mode Write Read ECC Detection and Countermeasure sequence Erase Failure Status Read after Erase --> Block Replacement Program Failure Status Read after Program --> Block Replacement Read back ( Verify after Program) --> Block Replacement or ECC Correction Single Bit Failure Verify ECC -> ECC Correction : Error Correcting Code --> Hamming Code etc. Example) 1bit correction & 2bit detection Program Flow Chart If ECC is used, this verification operation is not needed. Start Write 00h Write 80h Write Address Write Address Wait for tR Time Write Data Write 10h Verify Data Read Status Register No * Program Error Yes Program Completed I/O 6 = 1 ? or R/B = 1 ? * Program Error Yes No No * I/O 0 = 0 ? Yes 11 : If program operation results in an error, map out the block including the page in error and copy the target data to another block. SmartMediaTM K9S1208V0M-SSB0 SmartMedia Technical Notes (Continued) Erase Flow Chart Read Flow Chart Start Start Write 60h Write 00h Write Block Address Write Address Write D0h Read Data Read Status Register ECC Generation I/O 6 = 1 ? or R/B = 1 ? * Erase Error No Reclaim the Error Verify ECC Yes Yes No No Page Read Completed I/O 0 = 0 ? Yes Erase Completed * : If erase operation results in an error, map out the failing block and replace it with another block. Block Replacement Buffer memory error occurs Page a Block A Block B 12 When the error happens with page "a" of Block "A", try to write the data into another Block "B" from an external buffer. Then, prevent further system access to Block "A" (by creating a "invalid block" table or other appropriate scheme.) SmartMediaTM K9S1208V0M-SSB0 Pointer Operation of K9S1208V0M Samsung NAND Flash has three address pointer commands as a substitute for the two most significant column addresses. ’00h’ command sets the pointer to ’A’area(0~255byte), ’01h’command sets the pointer to ’B’area(256~511byte), and ’50h’command sets the pointer to ’C’ area(512~527byte). With these commands, the starting column address can be set to any of a whole page(0~527byte). ’00h’ or ’50h’ is sustained until another address pointer command is inputted. ’01h’ command, however, is effective only for one operation. After any operation of Read, Program, Erase, Reset, Power_Up is executed once with ’01h’ command, the address pointer returns to ’A’area by itself. To program data starting from ’A’or ’C’area, ’00h’or ’50h’command must be inputted before ’80h’command is written. A complete read operation prior to ’80h’ command is not necessary. To program data starting from ’B’area, ’01h’command must be inputted right before ’80h’command is written. Table 2. Destination of the pointer Command Pointer position Area 00h 01h 50h 0 ~ 255 byte 256 ~ 511 byte 512 ~ 527 byte 1st half array(A) 2nd half array(B) spare array(C) "A" area (00h plane) "B" area (01h plane) 256 Byte 256 Byte "A" "B" "C" area (50h plane) 16 Byte "C" Internal Page Register Pointer select commnad (00h, 01h, 50h) Pointer Figure 5. Block Diagram of Pointer Operation (1) Command input sequence for programming ’A’ area The address pointer is set to ’A’area(0~255), and sustained Address / Data input 00h 80h Address / Data input 10h 00h ’A’,’B’,’C’area can be programmed. It depends on how many data are inputted. 80h 10h ’00h’command can be omitted. (2) Command input sequence for programming ’B’ area The address pointer is set to ’B’area(256~512), and will be reset to ’A’area after every program operation is executed. Address / Data input Address / Data input 01h 80h 10h 01h ’B’, ’C’area can be programmed. It depends on how many data are inputted. 80h 10h ’01h’command must be rewritten before every program operation (3) Command input sequence for programming ’C’ area The address pointer is set to ’C’area(512~527), and sustained Address / Data input 50h 80h Address / Data input 10h 50h Only ’C’area can be programmed. 80h ’50h’command can be omitted. 13 10h SmartMediaTM K9S1208V0M-SSB0 System Interface Using CE don’t-care. For an easier system interface, CE may be inactive during the data-loading or sequential data-reading as shown below. The internal 528byte page registers are utilized as seperate buffers for this operation and the system design gets more flexible. In addition, for voice or audio applications which use slow cycle time on the order of u-seconds, de-activating CE during the data-loading and reading would provide significant savings in power consumption. Figure 6. Program Operation with CE don’t-care. CLE CE don’t-care WE ≈ ≈ CE ALE I/O0~7 80h Start Add.(4Cycle) tCS Data Input tCH Data Input 10h tCEA CE CE tREA RE tWP WE I/O0~7 out Figure 7. Read Operation with CE don’t-care. CLE CE don’t-care Must be held low during tR. ≈ CE RE ALE tR R/B WE I/O0~7 00h Data Output(sequential) Start Add.(4Cycle) 14 SmartMediaTM K9S1208V0M-SSB0 * Command Latch Cycle CLE tCLS tCLH tCS tCH CE tWP WE tALH tALS ALE tDH tDS Command I/O0~7 * Address Latch Cycle tCLS CLE tWC tCS tWC tWC CE tWP tWP tWP tWP WE tWH tALH tALS tALS tWH tALH tALS tWH tALH tALS tALH ALE tDS I/O0~7 tDH A0~A7 tDS tDH A9~A16 15 tDS tDH A17~A 24 tDS tDH A25 SmartMediaTM K9S1208V0M-SSB0 * Input Data Latch Cycle tCLH CLE tCH CE tWC tALS tWP ≈ ALE tWP tWP WE tWH tDH tDS tDH tDS tDH ≈ tDS I/O0~7 DIN 511 DIN 1 ≈ DIN 0 * Sequential Out Cycle after Read (CLE=L, WE=H, ALE=L) tRC ≈ CE tREH ≈ tREA tREA tREA tCHZ* RE tRHZ* Dout I/O0~7 Dout ≈ tRHZ* ≈ tRR R/B NOTES : Transition is measured ±200mV from steady state voltage with load. This parameter is sampled and not 100% tested. 16 Dout SmartMediaTM K9S1208V0M-SSB0 * Status Read Cycle tCLS CLE tCLS tCLH tCS CE tCH tWP WE tCEA tCHZ* tWHR RE tDS I/O0~7 tDH tREA tIR tRHZ* Status Output 70h READ1 OPERATION (READ ONE PAGE) CLE tCEH CE tCHZ tWC WE tWB tCRY tAR2 ALE tR tRHZ tRC ≈ RE I/O0~7 00h or 01h A0 ~ A7 A9 ~ A16 Column Address R/B A17 ~ A24 Dout N A25 Page(Row) Address Busy 17 Dout N+1 Dout N+2 ≈ ≈ tRR Dout 527 tRB SmartMediaTM K9S1208V0M-SSB0 READ1 OPERATION (INTERCEPTED BY CE) CLE CE WE tWB tCHZ tAR2 ALE tR tRC RE tRR I/O0~7 00h or 01h A9 ~ A16 A0 ~ A 7 Column Address A17 ~ A24 Dout N A25 Dout N+1 Dout N+2 Page(Row) Address Busy R/B READ2 OPERATION(READ ONE PAGE) CLE CE WE tR tWB tAR2 ALE ≈ tRR I/O0~7 50h A0 ~ A 7 A9 ~ A16 A17 ~ A24 Dout 511+M A25 R/B ≈ RE Dout 527 Selected Row M Address A0~A3 : Valid Address A4~A7 : Don′t care 512 16 Start address M 18 SmartMediaTM K9S1208V0M-SSB0 SEQUENTIAL ROW READ OPERATION ( WITHIN A BLOCK ) CLE CE WE ≈ ≈ ALE Dout N A25 Dout N+1 Ready Busy R/B Dout 527 Dout 0 Dout 1 Dout 527 ≈ A0 ~ A7 A9 ~ A16 A17 ~ A24 ≈ 00h ≈ I/O0~7 ≈ RE Busy M M+1 Output Output N PAGE PROGRAM OPERATION CLE CE tWC ≈ tWC tWC WE tWB tPROG ALE I/O0~7 80h A0 ~ A7 A9 ~ A16 A17 ~ A24 Sequential Data Column Input Command Address Page(Row) Address A25 ≈ ≈ RE Din Din 10h N 527 1 up to 528 Byte Data Program Command Serial Input ≈ R/B 70h 19 I/O0 Read Status Command I/O0=0 Successful Program I/O0=1 Error in Program SmartMediaTM K9S1208V0M-SSB0 BLOCK ERASE OPERATION (ERASE ONE BLOCK) CLE CE tWC WE tBERS tWB ALE RE I/O 0~7 60h A9 ~ A16 A17 ~ A24 A25 DOh 70h I/O 0 Busy R/B Auto Block Erase Setup Command Erase Command 20 ≈ Page(Row) Address Read Status Command I/O0=0 Successful Erase I/O0=1 Error in Erase 21 R/B I/O0~7 RE ALE WE Sequential Data Input Command 80h tWC I/O 0~7 R/B Din 527 80h A0 ~ A7 & A9 ~ A25 528 Byte Data Address & Data Input 11h tDBSY 80h 11h Program 1 up to 528 Byte Data Command (Dummy) Serial Input Din N Max. three times repeatable Page(Row) Address A25 ≈ ≈ ≈ Ex.) Four-Plane Page Program Column Address A0 ~ A7 A9 ~ A16 A17 ~ A24 Address & Data Input tDBSY : typ. 1us max. 10us tDBSY A0 ~ A7 & A9 ~ A25 528 Byte Data tWB ≈ CE 11h 80h A25 Din N A0 ~ A7 & A9 ~ A25 528 Byte Data Address & Data Input 11h tDBSY Last Plane Input & Program A0 ~ A7 A9 ~ A16 A17 ~ A24 tDBSY 80h ≈ ≈ ≈ CLE tPROG A0 ~ A7 & A9 ~ A25 528 Byte Data Address & Data Input 10h Program Confirm Command (True) 80h Din 527 tWB ≈ Multi-Plane Page Program Operation 71h tPROG 10h I/O 71h Read Multi-Plane Status Command K9S1208V0M-SSB0 SmartMediaTM SmartMediaTM K9S1208V0M-SSB0 Multi-Plane Block Erase Operation CLE CE tWC WE tBERS tWB ALE RE 60h I/O 0~7 A9 ~ A16 A17 ~ A24 A25 DOh 71h I/O 0 Busy R/B Block Erase Setup Command ≈ Page(Row) Address Erase Confirm Command Read Multi-Plane Status Command Max. 4 times repeatable * For Multi-Plane Erase operation, Block address to be erased should be repeated before "D0H" command. Ex.) Four-Plane Block Erase Operation R/B I/O0~7 tBERS 60h Address 60h Address 60h Address 60h A9 ~ A25 22 Address D0h 71h SmartMediaTM K9S1208V0M-SSB0 Read ID (1) Operation CLE CE WE ALE RE tREA I/O 0 ~ 7 90h 00h Read ID (1) Command Address. 1cycle ECh 76h Maker Code Device Code Read ID (2) Operation CLE CE WE ALE RE tREA I/O 0 ~ 7 00h 20h Address. 1cycle Maker Code 91h Read ID (2) Command ID Defintition Table 90 ID : Access command = 90H 91 ID : Access command = 91H READ ID (1) READ ID (2) st 1 Byte 2nd Byte Value ECh 76h Description st 1 Byte Maker Code Device Code 23 Value Description 20h Supports Multi Plane Operation SmartMediaTM K9S1208V0M-SSB0 Device Operation PAGE READ Upon initial device power up, the device defaults to Read1 mode. This operation is also initiated by writing 00h to the command register along with four address cycles. Once the command is latched, it does not need to be written for the following page read operation. Three types of operations are available : random read, serial page read and sequential row read. The random read mode is enabled when the page address is changed. The 528 bytes of data within the selected page are transferred to the data registers in less than 12µs(tR). The system controller can detect the completion of this data transfer(tR) by analyzing the output of R/B pin. Once the data in a page is loaded into the registers, they may be read out in 50ns cycle time by sequentially pulsing RE. High to low transitions of the RE clock output the data stating from the selected column address up to the last column address. After the data of last column address is clocked out, the next page is automatically selected for sequential row read. Waiting 12µs again allows reading the selected page. The sequential row read operation is terminated by bringing CE high. The way the Read1 and Read2 commands work is like a pointer set to either the main area or the spare area. The spare area of bytes 512 to 527 may be selectively accessed by writing the Read2 command. Addresses A0 to A3 set the starting address of the spare area while addresses A 4 to A7 are ignored. Unless the operation is aborted, the page address is automatically incremented for sequential row read as in Read1 operation and spare sixteen bytes of each page may be sequentially read. The Read1 command(00h/01h) is needed to move the pointer back to the main area. Figures 8 to 11 show typical sequence and timings for each read operation. Figure 8. Read1 Operation CLE CE WE ALE tR R/B RE I/O0~7 00h Start Add.(4Cycle) Data Output(Sequential) A0 ~ A7 & A9 ~ A25 (00h Command) 1st half array (01h Command)* 2st half array Data Field Spare Field 1st half array 2st half array Data Field Spare Field * After data access on 2nd half array by 01h command, the start pointer is automatically moved to 1st half array (00h) at next cycle. 24 SmartMediaTM K9S1208V0M-SSB0 Figure 9. Read2 Operation CLE CE WE ALE tR R/B RE 50h I/O 0~7 Data Output(Sequential) Start Add.(4Cycle) A0 ~ A3 & A9 ~ A25 Spare Field (A4 ~ A7 : Don′t Care) 1st half array 2nd half array Data Field Spare Field I/O0 ~ 7 tR tR R/B 00h Start Add.(4Cycle) 01h A0 ~ A7 & A9 ~ A25 ≈ Figure 10. Sequential Row Read1 Operation Data Output Data Output Data Output 2nd (528 Byte) Nth (528 Byte) 1st (01h Command) (00h Command) 1st half array 1st half array 2nd half array 1st 2nd Nth Data Field tR 2nd half array 1st 2nd Nth Block Data Field Spare Field Spare Field The Sequential Read 1 and 2 operation is allowed only within a block and after the last page of a block is readout, the sequential read operation must be terminated by bringing CE high. When the page address moves onto the next block, read command and address must be given. 25 SmartMediaTM K9S1208V0M-SSB0 I/O0~7 tR tR R/B 50h ≈ Figure 11. Sequential Row Read2 Operation Start Add.(4Cycle) Data Output 1st A0 ~ A3 & A9 ~ A25 tR Data Output Data Output 2nd (16Byte) Nth (16Byte) (A4 ~ A7 : Don ′t Care) 1st Block Nth Data Field Spare Field PAGE PROGRAM The device is programmed basically on a page basis, but it does allow multiple partial page programing of a byte or consecutive bytes up to 528, in a single page program cycle. The number of consecutive partial page programming operation within the same page without an intervening erase operation must not exceed 1 for main array and 2 for spare array. The addressing may be done in any random order in a block. A page program cycle consists of a serial data loading period in which up to 528 bytes of data may be loaded into the page register, followed by a non-volatile programming period where the loaded data is programmed into the appropriate cell. Serial data loading can be started from 2nd half array by moving pointer. About the pointer operation, please refer to the attached technical notes. The serial data loading period begins by inputting the Serial Data Input command(80h), followed by the four cycle address input and then serial data loading. The bytes other than those to be programmed do not need to be loaded.The Page Program confirm command(10h) initiates the programming process. Writing 10h alone without previously entering the serial data will not initiate the programming process. The internal write state control automatically executes the algorithms and timings necessary for program and verify, thereby freeing the system controller for other tasks. Once the program process starts, the Read Status Register command may be entered, with RE and CE low, to read the status register. The system controller can detect the completion of a program cycle by monitoring the R/B output, or the Status bit(I/O 6) of the Status Register. Only the Read Status command and Reset command are valid while programming is in progress. When the Page Program is complete, the Write Status Bit(I/O 0) may be checked(Figure 12). The internal write verify detects only errors for "1"s that are not successfully programmed to "0"s. The command register remains in Read Status command mode until another valid command is written to the command register. Figure 12. Program & Read Status Operation tPROG R/B I/O0~7 80h Address & Data Input 10h 70h A0 ~ A7 & A9 ~ A25 528 Byte Data I/O0 Fail 26 Pass SmartMediaTM K9S1208V0M-SSB0 BLOCK ERASE The Erase operation is done on a block(16K Byte) basis. Block address loading is accomplished in three cycles initiated by an Erase Setup command(60h). Only address A14 to A25 is valid while A9 to A13 is ignored. The Erase Confirm command(D0h) following the block address loading initiates the internal erasing process. This two-step sequence of setup followed by execution command ensures that memory contents are not accidentally erased due to external noise conditions. At the rising edge of WE after the erase confirm command input, the internal write controller handles erase and erase-verify. When the erase operation is completed, the Write Status Bit(I/O 0) may be checked. Figure 13 details the sequence. Figure 13. Block Erase Operation tBERS R/B I/O 0~7 60h Address Input(3Cycle) Pass I/O0 70h D0h Fail Block Add. : A 9 ~ A25 Fail MULTI-PLANE PAGE PROGRAM Multi-Plane Page Program is an extension of Page Program, which is executed for a single plane with 528 byte page registers. Since the device is equipped with four memory planes, activating the four sets of 528 byte page registers enables a simultaneous programming of four pages. Partial activation of four planes is also permitted. After writing the first set of data up to 528 byte into the selected page register, Dummy Page Program command (11h) instead of actual Page Program (10h) is inputted to finish data-loading of the current plane and move to the next plane. Since no programming process is involved, R/B remains in Busy state for a short period of time(tDBSY). Read Status command (standard 70h or alternate 71h) may be issued to find out when the device returns to Ready state by polling the Ready/Busy status bit(I/O 6). Then the next set of data for one of the other planes is inputted with the same command and address sequences. After inputting data for the last plane, actual True Page Program (10h) instead of dumy Page Program command (11h) must be followed to start the programming process. The operation of R/B and Read Status is the same as that of Page Program. Since maximum four pages are programmed simultaneously, pass/fail status is available for each page when the program operation completes. The extended status bits (I/O1 through I/ O 4) are checked by inputting the Read Multi-Plane Status Register. Status bit of I/O 0 is set to "1" when any of the pages fails. MultiPlane page Program with "01h" pointer is not supported, thus prohibited. Figure 14. Four-Plane Page Program tDBSY R/B I/O0~7 80h Address & 11h Data Input A0 ~ A7 & A9 ~ A25 80h tDBSY Address & Data Input 11h 80h 11h 80h tPROG tDBSY Address & Data Input 11h 80h 11h 80h Address & Data Input 10h 528 Byte Data 80h 11h 80h 10h Data input Plane 3 (1024 Block) Plane 0 (1024 Block) Plane 1 (1024 Block) Block 0 Block 1 Block 2 Block 3 Block 4 Block 5 Block 6 Block 7 Block 4088 Block 4092 Block 4089 Block 4093 Block 4090 Block 4094 Plane 2 (1024 Block) 27 Block 4091 Block 4095 71h SmartMediaTM K9S1208V0M-SSB0 RESTRICTION IN ADDRESSING WITH PLANE-PLANE PAGE PROGRAM While any block in each plane may be addressable for Multi-Plane Page Program, the four least significant addresses(A9-A13) for the selected pages at one operation must be the same. Figure 15 shows an example where 2nd page of each addressed block is selected for four planes. However, any arbitrary sequence is allowed in addressing multiple planes as shown in Figure16. Figure 15. Multi-Plane Program & Read Status Operation Block 0 Plane 3 (1024 Block) Plane 2 (1024 Block) Plane 1 (1024 Block) Plane 0 (1024 Block) Block 2 Block 1 Block 3 Page 0 Page 0 Page 0 Page 0 Page 1 Page 1 Page 1 Page 1 Page 30 Page 31 Page 30 Page 30 Page 31 Page 30 Page 31 Page 31 Figure 16. Addressing Multiple Planes Plane 2 80h 11h Plane 0 80h 11h Plane3 80h 11h Plane 1 80h 10h Figure 17. Multi-Plane Page Program & Read Status Operation tPROG R/B Last Plane input I/O0~7 80h Address & Data Input 10h Pass I/O 71h A0 ~ A7 & A9 ~ A25 528 Byte Data Fail The 15h command may be used as actual Page Program with 10h command. The pass/fail status data with 15h command are accumulated until the programming with 10h command as shown in Figure 18. Note that program with 10h command should be executed for the last pages of each four multi-plane blocks. Figure 18 shows an example when the 2nd page of plane 1 fails during multi-plane page program and fail status("1") sets. Figure 18. Multi-Plane Page Program Using 15h Command Read Status Register Data by 71h Command Plane 0 1st Page 80h 11h 80h 2nd Page 80h 11h 80h I/O 0 I/O 1 I/O 2 I/O 3 I/O 4 I/O 5 I/O 6 I/O 7 Plane 3 Plane 2 Plane 1 11h 80h 11h 80h 15h 0 11h 80h 11h 80h 15h 1 0 0 0 0 X 1 0 0 1 0 0 X 1 0 "Fail" Block N 31th Page 80h 11h 80h 11h 80h 11h 80h 15h 1 0 1 0 0 X 1 0 32nd Page 80h 11h 80h 11h 80h 11h 80h 10h 1 0 1 0 0 X 1 0 1st Page 80h 11h 80h 11h 80h 11h 80h 15h 0 0 0 0 X 1 0 0 Block N+1 - Please refer to "Read Status Register Definition" of Table 2 on page 29. - X means "don’t cared". 28 SmartMediaTM K9S1208V0M-SSB0 MULTI-PLANE BLOCK ERASE Basic concept of Multi-Plane Block Erase operation is identical to that of Multi-Plane Page Program. Up to four blocks, one from each plane can be simultaneously erased. Standard Block Erase command sequences (Block Erase Setup command followed by three address cycles) may be repeated up to four times for erasing up to four blocks. Only one block should be selected from each plane. The Erase Confirm command initiates the actual erasing process. The completion is detected by analyzing R/B pin or Ready/Busy status (I/O 6). Upon the erase completion, pass/fail status of each block is examined by reading extended pass/fail status(I/O 1 through I/O 4). Figure 19. Four Block Erase Operation tBERS R/B I/O0~7 60h Address (3 Cycle) 60h Address (3 Cycle) 60h Address (3 Cycle) 60h Address (3 Cycle) D0h 71h I/O A0 ~ A7 & A9 ~ A25 Fail READ STATUS The device contains a Status Register which may be read to find out whether program or erase operation is completed, and whether the program or erase operation is completed successfully. After writing 70h command to the command register, a read cycle outputs the content of the Status Register to the I/O pins on the falling edge of CE or RE, whichever occurs last. This two line control allows the system to poll the progress of each device in multiple memory connections even when R/B pins are common-wired. RE or CE does not need to be toggled for updated status. Refer to table 2 for specific Status Register definitions. The command register remains in Status Read mode until further commands are issued to it. Therefore, if the status register is read during a random read cycle, a read command(00h or 50h) should be given before sequential page read cycle. For Read Status of Multi Plane Program/Erase, the Read Multi-Plane Status command(71h) should be used to find out whether multi-plane program or erase operation is completed, and whether the program or erase operation is completed successfully. The pass/fail status data must be checked only in the Ready condition after the completion of Multi-Plane program or erase operation. Table2. Read Staus Register Definition I/O No. Status I/O 0 Total Pass/Fail Definition by 70h Command Pass : "0" Fail : "1" Definition by 71h Command Pass : "0"(1) Fail : "1" I/O 1 Plane 0 Pass/Fail Must be don’t -cared Pass : "0" I/O 2 Plane 1 Pass/Fail Must be don’t -cared Pass : "0"(2) Fail : "1" I/O 3 Plane 2 Pass/Fail Must be don’t -cared Pass : "0" (2) Fail : "1" I/O 4 Plane 3 Pass/Fail Must be don’t -cared Pass : "0" (2) Fail : "1" I/O 5 Reserved Must be don’t -cared Must be don’t-cared I/O 6 Device Operation I/O 7 Write Protect Busy : "0" Protected : "0" Ready : "1" Not Protected : "1" (2) Fail : "1" Busy : "0" Protected : "0" Ready : "1" Not Protected : "1" NOTE : 1. I/O 0 describes combined Pass/Fail condition for all planes. If any of the selected multiple pages/blocks fails in Program/ Erase operation, it sets "Fail" flag. 2. The pass/fail status applies only to the corresponding plane. 29 Pass SmartMediaTM K9S1208V0M-SSB0 READ ID The device contains a product identification mode, initiated by writing 90h and 91h to the command register, followed by an address input of 00h. Two read cycles with 90h sequentially output the manufacture code(ECh) and the device code (76h) respectively. One read cycle with 91h outputs the Multi plane operation code(20h). 20h means that device supports Multi Plane operation. The command register remains in Read ID mode until further commands are issued to it. Figure 20 and 21 show the operation sequence. Figure 20. Read ID (1) Operation CLE tCEA CE WE tAR1 ALE tWHR RE I/O0~7 90h tREA 00h ECh Address. 1cycle Maker code Figure 21. Read ID (2) Operation CLE tCEA CE WE tAR1 ALE tWHR RE I/O 0~7 91h tREA 00h 20h Address. 1cycle Maker code 30 76h Device code SmartMediaTM K9S1208V0M-SSB0 RESET The device offers a reset feature, executed by writing FFh to the command register. When the device is in Busy state during random read, program or erase mode, the reset operation will abort these operations. The contents of memory cells being altered are no longer valid, as the data will be partially programmed or erased. The command register is cleared to wait for the next command, and the Status Register is cleared to value C0h when WP is high. Refer to table 4 for device status after reset operation. If the device is already in reset state a new reset command will not be accepted by the command register. The R/B pin transitions to low for tRST after the Reset command is written. Reset command is not necessary for normal operation. Refer to Figure 22 below. Figure 22. RESET Operation tRST R/B I/O 0~7 FFh Table4. Device Status After Power-up After Reset Read 1 Waiting for next command Operation Mode READY/BUSY The device has a R/B output that provides a hardware method of indicating the completion of a page program, erase and random read completion. The R/B pin is normally high but transitions to low after program or erase command is written to the command register or random read is started after address loading. It returns to high when the internal controller has finished the operation. The pin is an open-drain driver thereby allowing two or more R/B outputs to be Or-tied. An appropriate pull-up resister is required for proper operation and the value may be calculated by the following equation. Rp VCC 3.2V VCC(Max.) - VOL(Max.) Rp = R/B open drain output IOL + ΣIL = 8mA + ΣIL where IL is the sum of the input currents of all devices tied to the R/B pin. GND Device 31 SmartMediaTM K9S1208V0M-SSB0 DATA PROTECTION The device is designed to offer protection from any involuntary program/erase during power-transitions. An internal voltage detector disables all functions whenever Vcc is below about 2V. WP pin provides hardware protection and is recommended to be kept at VIL during power-up and power-down as shown in Figure 23. The two step command sequence for program/erase provides additional software protection. ≈ Figure 23. AC Waveforms for Power Transition ~ 2.5V VCC ≈ High WP 32 ~ 2.5V SmartMediaTM SmartMedia Dimensions DIMENSIONS Unit:mm 22 PAD SOLID STATE FLOPPY DISK CARD (3.3V) SOLID STATE PRODUCT OUTLINE 37.0±0.1 0.15±0.05 5.0±0.2 Index Label Area 10.0±0.2 Write Protect Area Contact Area (+0.1mm package body surface) 33.0±0.2 22.1(Max) 27.5 45.0±0.1 4.5(Min) 0 5. 0.5mm Chamfer 4.2(Min) (3.3V Card) 0.76±0.08 1.5±0.1 27.0 0.000 2.540 5.080 7.620 10.160 12.700 2.140 TYP 0.400 TYP 22 12 I/O5 I/O6 I/O7 vcc GND R/B RE CE vcc I/O3 I/O2 I/O1 I/O0 WP WE ALE CLE vSS I/O4 vcc 8.650 7.900 6.500 0.000 vSS 6.500 7.900 8.650 1 11 12.700 10.160 7.620 5.080 2.540 0.000 33