VISHAY 20TQSPBF

20TQ...SPbF
Vishay High Power Products
Schottky Rectifier, 20 A
FEATURES
• 150 °C TJ operation
D2PAK
Available
• Low forward voltage drop
Base
cathode
2
RoHS*
• High frequency operation
COMPLIANT
• High purity, high temperature epoxy
encapsulation for enhanced mechanical strength and
moisture resistance
1
N/C
• Guard ring for enhanced ruggedness and long term
reliability
3
Anode
• Lead (Pb)-free (“PbF” suffix)
• Designed and qualified for Q101 level
DESCRIPTION
PRODUCT SUMMARY
IF(AV)
20 A
VR
35 to 45 V
The 20TQ.. Schottky rectifier series has been optimized for
very low forward voltage drop, with moderate leakage. The
proprietary barrier technology allows for reliable operation up
to 150 °C junction temperature. Typical applications are in
switching power supplies, converters, freewheeling diodes,
and reverse battery protection.
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL
CHARACTERISTICS
IF(AV)
Rectangular waveform
VRRM
Range
IFSM
VF
TJ
Range
VALUES
UNITS
20
A
35 to 45
V
tp = 5 µs sine
1800
A
20 Apk, TJ = 125 °C
0.51
V
- 55 to 150
°C
VOLTAGE RATINGS
PARAMETER
SYMBOL
Maximum DC reverse voltage
Maximum working peak reverse voltage
VR
VRWM
20TQ035SPbF
20TQ040SPbF
20TQ045SPbF
UNITS
35
40
45
V
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Maximum average forward current
See fig. 5
IF(AV)
Maximum peak one cycle
non-repetitive surge current
See fig. 7
IFSM
Non-repetitive avalanche energy
EAS
TJ = 25 °C, IAS = 4 A, L = 3.40 mH
27
mJ
IAR
Current decaying linearly to zero in 1 µs
Frequency limited by TJ maximum VA = 1.5 x VR typical
4
A
Repetitive avalanche current
50 % duty cycle at TC = 116 °C, rectangular waveform
5 µs sine or 3 µs rect. pulse
10 ms sine or 6 ms rect. pulse
Following any rated load
condition and with rated
VRRM applied
20
1800
A
400
* Pb containing terminations are not RoHS compliant, exemptions may apply
Document Number: 94168
Revision: 14-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
1
20TQ...SPbF
Schottky Rectifier, 20 A
Vishay High Power Products
ELECTRICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
20 A
Maximum forward voltage drop
See fig. 1
VFM (1)
20 A
IRM (1)
0.73
0.67
2.7
VR = Rated VR
TJ = 125 °C
Maximum junction capacitance
CT
VR = 5 VDC (test signal range 100 kHz to 1 MHz) 25 °C
LS
Measured lead to lead 5 mm from package body
dV/dt
mA
105
Typical series inductance
Maximum voltage rate of change
V
0.51
TJ = 125 °C
TJ = 25 °C
UNITS
0.57
TJ = 25 °C
40 A
40 A
Maximum reverse leakage current
See fig. 2
VALUES
Rated VR
1400
pF
8.0
nH
10 000
V/µs
Note
(1) Pulse width < 300 µs, duty cycle < 2 %
THERMAL - MECHANICAL SPECIFICATIONS
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
- 55 to 150
°C
Maximum junction and storage
temperature range
TJ, TStg
Maximum thermal resistance,
junction to case
RthJC
DC operation
See fig. 4
1.50
Typical thermal resistance,
case to heatsink
RthCS
Mounting surface, smooth and greased
0.50
2
g
0.07
oz.
minimum
6 (5)
kgf ⋅ cm
maximum
12 (10)
(lbf ⋅ in)
Approximate weight
Mounting torque
Marking device
www.vishay.com
2
°C/W
Case style
D2PAK
For technical questions, contact: [email protected]
20TQ045S
Document Number: 94168
Revision: 14-Aug-08
20TQ...SPbF
Schottky Rectifier, 20 A
1000
IR - Reverse Current (mA)
IF - Instantaneous
Forward Current (A)
1000
Vishay High Power Products
100
TJ = 150 °C
TJ = 125 °C
TJ = 25 °C
10
1
0.1
TJ = 150 °C
100
TJ = 125 °C
10
TJ = 100 °C
1
TJ = 75 °C
TJ = 50 °C
0.1
TJ = 25 °C
0.01
0.001
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0
1.8
5
10
15
20
25
30
35
40
45
VFM - Forward Voltage Drop (V)
VR - Reverse Voltage (V)
Fig. 1 - Maximum Forward Voltage Drop Characteristics
Fig. 2 - Typical Values of Reverse Current vs.
Reverse Voltage
CT - Junction Capacitance (pF)
10 000
TJ = 25 °C
100
0
10
20
30
40
50
VR - Reverse Voltage (V)
ZthJC - Thermal Impedance (°C/W)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage
10
1
PDM
0.1
t1
D = 0.50
D = 0.33
D = 0.25
D = 0.17
D = 0.08
0.01
Single pulse
(thermal resistance)
0.001
0.00001
0.0001
0.001
0.01
t2
Notes:
1. Duty factor D = t1/t2
2. Peak TJ = PDM x ZthJC + TC
0.1
1
10
100
t1 - Rectangular Pulse Duration (s)
Fig. 4 - Maximum Thermal Impedance ZthJC Characteristics
Document Number: 94168
Revision: 14-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
3
20TQ...SPbF
Schottky Rectifier, 20 A
Vishay High Power Products
18
D = 0.08
D = 0.17
D = 0.25
D = 0.33
D = 0.50
16
20TQ
RthJC (DC) = 1.50 °C/W
Average Power Loss (W)
Allowable Case Temperature (°C)
155
145
135
DC
125
14
12
10
RMS limit
8
6
DC
4
2
0
115
0
5
10
15
20
0
30
25
5
10
15
20
25
30
IF(AV) - Average Forward Current (A)
Fig. 5 - Maximum Allowable Case Temperature vs.
Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
IFSM - Non-Repetitive Surge Current (A)
IF(AV) - Average Forward Current (A)
10 000
At any rated load condition
and with rated VRRM applied
following surge
1000
100
10
100
1000
10 000
tp - Square Wave Pulse Duration (µs)
Fig. 7 - Maximum Non-Repetitive Surge Current
L
D.U.T.
IRFP460
Rg = 25 Ω
Current
monitor
High-speed
switch
Freewheel
diode
+ Vd = 25 V
40HFL40S02
Fig. 8 - Unclamped Inductive Test Circuit
www.vishay.com
4
For technical questions, contact: [email protected]
Document Number: 94168
Revision: 14-Aug-08
20TQ...SPbF
Schottky Rectifier, 20 A
Vishay High Power Products
ORDERING INFORMATION TABLE
Device code
20
T
Q
045
S
1
2
3
4
5
1
-
Current rating (20 A)
2
-
Package:
TRL PbF
6
7
T = TO-220
3
-
Schottky “Q” series
4
-
Voltage ratings
5
-
S = D2PAK
6
-
None = Tube (50 pieces)
035 = 35 V
040 = 40 V
045 = 45 V
TRL = Tape and reel (left oriented)
TRR = Tape and reel (right oriented)
7
-
None = Standard production
PbF = Lead (Pb)-free
LINKS TO RELATED DOCUMENTS
Dimensions
http://www.vishay.com/doc?95014
Part marking information
http://www.vishay.com/doc?95008
Packaging information
http://www.vishay.com/doc?95032
Document Number: 94168
Revision: 14-Aug-08
For technical questions, contact: [email protected]
www.vishay.com
5
Legal Disclaimer Notice
Vishay
Disclaimer
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.
Document Number: 91000
Revision: 18-Jul-08
www.vishay.com
1