SANYO LA5692M

Ordering number : EN2770B
Monolithic Linear IC
LA5692D, 5692S, 5692M
Voltage Regulator Driver
with Watchdog Timer
Overview
Package Dimensions
The LA5692 is a single-chip voltage regulator for unit: mm
microcomputer system monitor use that performs the
3001B-DIP8
functions of 5V output voltage control, watchdog timer,
and voltage detector. Since the LA5692 can hold the reset
output, it is especially suited for use in peripheral control
and monitor output applications (example : valves used in
refrigeration equipment, hot water supply system).
[LA5692D]
8
0.25
7.62
6.4
5
1
4
0.5
0.89
Functions
3.0
3.9max
• Microcomputer system for car equipment, refrigeration/
heating equipment, office automation equipment.
3.2
Applications
0.51min
9.4
1.4
SANYO : DIP8
2.54
unit: mm
• Output voltage 5V control.
• Watchdog timer.
• Reset generation at power-ON mode.
• Reset hold output [RES (2)] (Cleared with CK reinput).
3017B-SIP9
[LA5692S]
22.3
3.0
0.51 min
3.2
1.0
• An external PNP transistor can be used to provide a lowsaturation voltage regulator.
• CK input with edge detector.
• Variable detection voltage.
• The watchdog time can be made longer.
4.8
Features
5.7 max
1.5
1
0.99
9
2.54
1.3
0.5
0.25
1.35
SANYO : SIP9
unit: mm
3032B-MFP8
0.625
[LA5692M]
8
4.4
5.15
6.4
5
4
1.8max
1
0.15
0.1
1.5
5.1
0.35
1.27
0.645
SANYO : MFP8
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
D0597HA (KT)/8099YT/8037TA, TS No.2770-1/6
LA5692D, 5692S, 5692M
Specifications
Maximum Ratings at Ta=25°C
Parameter
Symbol
Conditions
Ratings
1s
Unit
Control pin voltage
VCONTmax
Control pin voltage
VCONTmax
Control pin current
ICONTmax
CK input voltage
VCKmax
Reset pin voltage
VRES(1)max,
41
V
LA5692D, 5692S
500
mW
LA5692M
370
mW
*VCC≥6V
60
V
41
V
11
mA
25
V
VRES(2)max
Allowable power dissipation
Pd max
Operating temperature
Topr
–40 to +85
°C
Storage temperature
Tstg
–55 to +150
°C
* : A PNP transistor is connected to the LA5692D, 5692S externally to provide a low-saturation voltage regulator.
Therefore, ICONT≈100mA will flow, as starting current, in the VCC range where the output cannot be regulated.
Operating Conditions at Ta=25°C
Parameter
Symbol
Control pin voltage
VCONT
Control pin current
ICONTmax
Reset output current
IRES(1)max,
Conditions
Ratings
Unit
6 to 40
External R pull-up
V
10
mA
8
mA
4
V
IRES(2)max
Reset detection voltage
VS min
Operating Characteristics at Ta=25°C, VCC=14V, IO=50mA, unless otherwise specified.
Parameter
Symbol
Conditions
Ratings
min
typ
max
4.8
Unit
Output voltage
VO
5.0
5.2
V
Line regulation1
∆VOLN1
9V≤VCC≤16V
2
10
mV
Line regulation2
∆VOLN2
6V≤VCC≤40V
4
30
mV
Load regulation
∆VOLD
1mA≤IO≤50mA
4
30
mV
Current dissipation
ICC
IO=0
4.4
6.5
mA
Output noise voltage
VNO
10Hz≤f≤100kHz, VCK=0
150
µV
Temperature coefficient
∆VO /∆Ta
IO=5mA, –40°C≤Ta≤+85°C
±0.2
mV/°C
of output voltage
1.13
Reference voltage
VREF
‘H’-level CK input voltage
VIH
‘L’-level CK input voltage
VIL
‘H’-level CK input current
IIH
VCK=5V
‘L’-level CK input current
IIL
VCK=0V
‘H’-level reset output voltage
VORH(1)/
RES(2) : 10kΩ pull-up
1.18
1.23
2
V
V
0.3
0.8
V
0.7
mA
–1.0
–0.1
4.8
5.0
5.2
µA
V
RES(2) : 10kΩ pull-up
40
200
mV
‘L’-level reset output voltage2 VORL(1)2/
VORL(2)2
IRES(1)=IRES(2)=8mA
0.16
0.8
V
CK input pulse width
tCKW
VCK=5V
Reset output delay time
td
Ct=1µF
7.5
10
12.5
ms
Watchdog time
tWD
Ct=1µF
30
40
50
ms
Watchdog reset time
tWR
Ct=1µF
0.1
0.25
0.4
ms
Reset hysteresis voltage
Vhys
VS=4.5V
100
200
300
mV
VORH(2)
‘L’-level reset output voltage1 VORL(1)1/
VORL(2)1
3
µs
No.2770-2/6
LA5692D, 5692S, 5692M
Pin Assignment
Do not use the NC pin.
Top view
Equivalent Circuit Block Diagram
Starter
Error
amp
Reset
generator
Voltage detector
RES(1) : Contains a pull-up resistor of 10kΩ.
RES(2) : Open collector
Test Circuit
Unit (resistance : Ω, capacitance : F)
No.2770-3/6
LA5692D, 5692S, 5692M
Sample Application Circuit
Unit (resistance : Ω, capacitance : F)
Note on application
1. For stable operation, place Cin, CO, and TR1 as near to the IC as possible.
2. When used in 0°C or below it, a capacitor of which impedance at high-frequency operation is low and has a good
temperature characteristic (such as SANYO OS-CON capacitor or others) should be used to prevent oscillation.
3. Set VS to the output voltage level where the circuit will be reset using external resistors R1 and R2. VS should be set
to 4V or greater due to internal circuit operation.
4. CCK must be inserted to cut the high range element of clock noise to prevent it from becoming a reset output noise.
5. For Ct, a capacitor which less varies the capacitance according to the temperature should be used.
Timing Chart
Application of power
Instantaneous drop
Digital output at I/O
port of microcomputer
Microcomputer
operation start
CPU
abnormality
Note : Edge-triggered at the point indicated by the arrow of CK signal.
No.2770-4/6
Output voltage, VO – V
Allowable power dissipation, Pd max – mW
LA5692D, 5692S, 5692M
Supply voltage, VCC – V
Output voltage, VO – V
Reset output voltage, VRES – V
Ambient temperature, Ta – °C
Indeterminate operation
Ambient temperature, Ta – °C
Current drain, ICC – mA
Current drain, ICC – mA
Output voltage, VO – V
Ambient temperature, Ta – °C
Ripple rejection, Rrej – dB
Reset output delay time, td – ms
Watchdog time, tWD – ms
Supply voltage, VCC – V
Frequency, f – Hz
Ambient temperature, Ta – °C
No.2770-5/6
Watchdog time, tWR – ms
CK input threshold voltage, VIN – V
LA5692D, 5692S, 5692M
Ambient temperature, Ta – °C
CK input current, IIH – µA
L reset output voltage, VORL(2) – mV
Ambient temperature, Ta – °C
Ambient temperature, Ta – °C
Reset output current, IRES(2) – mA
No products described or contained herein are intended for use in surgical implants, life-support systems,
aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and
the like, the failure of which may directly or indirectly cause injury, death or property loss.
Anyone purchasing any products described or contained herein for an above-mentioned use shall:
Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates,
subsidiaries and distributors and all their officers and employees, jointly and severally, against any
and all claims and litigation and all damages, cost and expenses associated with such use:
Not impose any responsibilty for any fault or negligence which may be cited in any such claim or
litigation on SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of
their officers and employees jointly or severally.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees
are made or implied regarding its use or any infringements of intellectual property rights or other rights of
third parties.
This catalog provides information as of December, 1997. Specifications and information herein are subject
to change without notice.
No.2770-6/6