SANYO SB10W05Z

Ordering number : EN3876A
Schottky Barrier Diode (Twin Type · Cathode Common)
SB10W05Z
50V, 1A Rectifier
Applications
• High frequency rectification (switching regulators, converters, choppers).
Features
• Low forward voltage (VF max=0.55V).
• Fast reverse recovery time (trr max=10ns).
• Low switching noise.
• Low leakage current and high reliability due to highly reliable planar structure.
Absolute Maximum Ratings at Ta=25°C (Value per element)
Repetitive Peak Reverse Voltage
Nonrepetitive Peak Reverse
Surge Voltage
Average Output Current
Surge Forward Current
Junction Temperature
Storage Temperature
Io
IFSM
Tj
Tstg
50Hz sine wave, 1 cycle
Electrical Characteristics at Ta=25°C (Value per element)
Reverse Voltage
Forward Voltage
Reverse Current
Interterminal Capacitance
Reverse Recovery Time
VR
VF
IR
c
trr
Thermal Resistance
Rthj-a
trr Test Circuit
50
55
unit
V
V
1
10
–55 to +125
–55 to +125
A
A
°C
°C
VRRM
VRSM
IR=300µA
IF=1A
VR=25V
VR=10V, f=1MHz
IF=IR=100mA
See specified Test Circuit.
min
50
typ
max
0.55
80
52
10
75
unit
V
V
µA
pF
ns
°C/W
Package Dimensions 1243A
(unit : mm)
Electrical Connection
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
O0797GI/42297YH (KOTO) 8-7461 No.3876-1/2
Forward Current, IF – A
Reverse Current, IR – mA
SB10W05Z
Reverse Voltage, VR – V
Average Reverse Power Dissipation, PR(AV) – mW
Peak Reverse Voltage, VRM – V
Surge Forward Current, Is(Peak) – S
Average Foward Current, Io – A
Interterminal Capacitance, C – pF
Average Forward Power Dissipation, PF(AV) – W
Forward Voltage, VF – V
Reverse Voltage, VR – V
Time, t – s
No products described or contained herein are intended for use in surgical implants, life-support systems,
aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and
the like, the failure of which may directly or indirectly cause injury, death or property lose.
Anyone purchasing any products described or contained herein for an above-mentioned use shall:
Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates,
subsidiaries and distributors and all their officers and employees, jointly and severally, against any
and all claims and litigation and all damages, cost and expenses associated with such use:
Not impose any responsibilty for any fault or negligence which may be cited in any such claim or
litigation on SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of
their officers and employees jointly or severally.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees
are made or implied regarding its use or any infringements of intellectual property rights or other rights of
third parties.
This catalog provides information as of October, 1997. Specifications and information herein are subject
to change without notice.
No.3876-2/2