Ordering number : EN3876A Schottky Barrier Diode (Twin Type · Cathode Common) SB10W05Z 50V, 1A Rectifier Applications • High frequency rectification (switching regulators, converters, choppers). Features • Low forward voltage (VF max=0.55V). • Fast reverse recovery time (trr max=10ns). • Low switching noise. • Low leakage current and high reliability due to highly reliable planar structure. Absolute Maximum Ratings at Ta=25°C (Value per element) Repetitive Peak Reverse Voltage Nonrepetitive Peak Reverse Surge Voltage Average Output Current Surge Forward Current Junction Temperature Storage Temperature Io IFSM Tj Tstg 50Hz sine wave, 1 cycle Electrical Characteristics at Ta=25°C (Value per element) Reverse Voltage Forward Voltage Reverse Current Interterminal Capacitance Reverse Recovery Time VR VF IR c trr Thermal Resistance Rthj-a trr Test Circuit 50 55 unit V V 1 10 –55 to +125 –55 to +125 A A °C °C VRRM VRSM IR=300µA IF=1A VR=25V VR=10V, f=1MHz IF=IR=100mA See specified Test Circuit. min 50 typ max 0.55 80 52 10 75 unit V V µA pF ns °C/W Package Dimensions 1243A (unit : mm) Electrical Connection SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN O0797GI/42297YH (KOTO) 8-7461 No.3876-1/2 Forward Current, IF – A Reverse Current, IR – mA SB10W05Z Reverse Voltage, VR – V Average Reverse Power Dissipation, PR(AV) – mW Peak Reverse Voltage, VRM – V Surge Forward Current, Is(Peak) – S Average Foward Current, Io – A Interterminal Capacitance, C – pF Average Forward Power Dissipation, PF(AV) – W Forward Voltage, VF – V Reverse Voltage, VR – V Time, t – s No products described or contained herein are intended for use in surgical implants, life-support systems, aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and the like, the failure of which may directly or indirectly cause injury, death or property lose. Anyone purchasing any products described or contained herein for an above-mentioned use shall: Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors and all their officers and employees, jointly and severally, against any and all claims and litigation and all damages, cost and expenses associated with such use: Not impose any responsibilty for any fault or negligence which may be cited in any such claim or litigation on SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of their officers and employees jointly or severally. Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees are made or implied regarding its use or any infringements of intellectual property rights or other rights of third parties. This catalog provides information as of October, 1997. Specifications and information herein are subject to change without notice. No.3876-2/2