M58LT128GST M58LT128GSB 128Mbit (8Mb x16, Multiple Bank, Multi-Level, Burst) 1.8V Supply Secure Flash Memories PRELIMINARY DATA Features Summary ■ SUPPLY VOLTAGE – VDD = 1.7 to 2.0V for program, erase and read – VDDQ = 2.7 to 3.6V for I/O Buffers – VPP = 9V for fast program ■ SYNCHRONOUS / ASYNCHRONOUS READ – Random Access: 110ns – Asynchronous Page Read: 25ns. – Synchronous Burst Read: 52MHz ■ SYNCHRONOUS BURST READ SUSPEND ■ PROGRAMMING TIME – 10µs typical Word program time using Buffer Enhanced Factory Program command ■ MEMORY ORGANIZATION – Multiple Bank Memory Array: 8 Mbit Banks – Parameter Blocks (Top or Bottom location) ■ DUAL OPERATIONS – program/erase in one Bank while read in others – No delay between read and write operations ■ HARDWARE PROTECTION – All Blocks Write Protected when VPP≤VPPLK ■ SECURITY – Software Security Features – 64-bit Unique Device Identifier – 2112 bits of User-Programmable OTP memory ■ COMMON FLASH INTERFACE (CFI) BGA TBGA64 (ZA) 10 x 13mm ■ 100,000 PROGRAM/ERASE CYCLES per BLOCK ■ ELECTRONIC SIGNATURE – Manufacturer Code: 20h – Device Code: M58LT128GST: 88C6h M58LT128GSB: 88C7h ■ ECOPACK® PACKAGE AVAILABLE September 2005 This is preliminary information on a new product now in development or undergoing evaluation. Details are subject to change without notice. Rev 1.0 1/98 www.st.com 1 M58LT128GST, M58LT128GSB Contents 1 Summary description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 Signal descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.1 Address Inputs (A0-A22) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.2 Data Input/Output (DQ0-DQ15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.3 Chip Enable (E) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.4 Output Enable (G) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.5 Write Enable (W) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.6 Reset (RP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.7 Latch Enable (L) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.8 Clock (K) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.9 Wait (WAIT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.10 VDD Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.10.1 VDDQ Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3 4 2/98 2.11 VPP Program Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 2.12 VSS Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.13 VSSQ Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Bus operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.1 Bus Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.2 Bus Write . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.3 Address Latch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.4 Output Disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.5 Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 3.6 Reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Command Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 4.1 Read Array command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 4.2 Read Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 4.3 Read Electronic Signature command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 4.4 Read CFI Query command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 4.5 Clear Status Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 M58LT128GST, M58LT128GSB 4.6 Block Erase command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 4.7 Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 4.8 Buffer Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 4.9 Buffer Enhanced Factory Program command . . . . . . . . . . . . . . . . . . . . . . . . 23 4.9.1 Setup phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 4.9.2 Program and Verify phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.9.3 Exit phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 4.10 Program/Erase Suspend command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 4.11 Program/Erase Resume command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 4.11.1 Protection Register Program command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 4.12 5 6 7 Set Configuration Register command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Status Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.1 Program/Erase Controller Status Bit (SR7) . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.2 Erase Suspend Status Bit (SR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 5.3 Erase Status Bit (SR5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.4 Program Status Bit (SR4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.5 VPP Status Bit (SR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 5.6 Program Suspend Status Bit (SR2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 5.7 Bank Write/Multiple Word Program Status Bit (SR0) . . . . . . . . . . . . . . . . . . 33 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6.1 Read Select Bit (CR15) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6.2 X-Latency Bits (CR13-CR11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 6.3 Wait Polarity Bit (CR10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6.4 Data Output Configuration Bit (CR9) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6.5 Wait Configuration Bit (CR8) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6.6 Burst Type Bit (CR7) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6.7 Valid Clock Edge Bit (CR6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.8 Wrap Burst Bit (CR3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 6.9 Burst length Bits (CR2-CR0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Read modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 7.1 Asynchronous Read modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 7.1.1 Asynchronous Random Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 3/98 M58LT128GST, M58LT128GSB 7.1.2 7.2 Asynchronous Page Read . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Synchronous Burst Read modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.2.1 Synchronous Burst Read Suspend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 7.2.2 Single Synchronous Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 8 Dual Operations and Multiple Bank architecture . . . . . . . . . . . . . . . . . . . 45 9 Program and Erase times and Endurance cycles . . . . . . . . . . . . . . . . . . 47 10 Maximum Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 11 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 12 Package mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 13 Part Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Appendix A Block address tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Appendix B Common Flash Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Appendix C Flowcharts and Pseudo Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Appendix D Command Interface state tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 14 4/98 REVISION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 M58LT128GST, M58LT128GSB List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. Table 23. Table 24. Table 25. Table 26. Table 27. Table 28. Table 29. Table 30. Table 31. Table 32. Table 33. Table 34. Table 35. Table 36. Table 37. Table 38. Table 39. Table 40. Table 41. Table 42. Table 43. Table 44. Table 45. Table 46. Table 47. Table 48. Signal Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Bank Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Bus Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Command Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Standard Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Factory Program Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Electronic Signature Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Protection Register Lock Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Status Register Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Configuration Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Burst Type Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Wait at the Boundary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Dual Operations Allowed In Other Banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Dual Operations Allowed In Same Bank. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Dual Operation Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Program/Erase Times and Endurance Cycles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Operating and AC Measurement Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 DC Characteristics - Currents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 DC Characteristics - Voltages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Asynchronous Read AC Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Synchronous Read AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Write AC Characteristics, Write Enable Controlled. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Write AC Characteristics, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Reset and Power-up AC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 TBGA64 10x13mm - 8x8 active ball array, 1mm pitch, Package Mechanical Data . . . . . . 66 Ordering Information Scheme. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Daisy Chain Ordering Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 M58LT128GST - Parameter Bank Block Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 M58LT128GST - Main Bank Base Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 M58LT128GST - Block Addresses in Main Banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 M58LT128GSB - Parameter Bank Block Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 M58LT128GSB- Main Bank Base Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 M58LT128GSB - Block Addresses in Main Banks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Query Structure Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 CFI Query Identification String . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 CFI Query System Interface Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Device Geometry Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Primary Algorithm-Specific Extended Query Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Protection Register Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Burst Read Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Bank and Erase Block Region Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Bank and Erase Block Region 1 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Bank and Erase Block Region 2 Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Command Interface States - Modify Table, Next State . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Command Interface States - Modify Table, Next Output State. . . . . . . . . . . . . . . . . . . . . . 92 Command Interface States - Lock Table, Next State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 5/98 M58LT128GST, M58LT128GSB Table 49. Table 50. 6/98 Command Interface States - Lock Table, Next Output State . . . . . . . . . . . . . . . . . . . . . . . 95 Document Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 M58LT128GST, M58LT128GSB List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Logic Diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 TBGA64 Connections (Top view through package) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Memory Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Protection Register Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 X-Latency and Data Output Configuration Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Wait Configuration Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 AC Measurement I/O Waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 AC Measurement Load Circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Asynchronous Random Access Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Asynchronous Page Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Synchronous Burst Read AC Waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Single Synchronous Read AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Synchronous Burst Read Suspend AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Clock input AC Waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Write AC Waveforms, Write Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Write AC Waveforms, Chip Enable Controlled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Reset and Power-up AC Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 TBGA64 10x13mm - 8x8 active ball array, 1mm pitch, Bottom View Package Outline . . . 66 Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Buffer Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Program Suspend & Resume Flowchart and Pseudo Code. . . . . . . . . . . . . . . . . . . . . . . . 85 Block Erase Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Erase Suspend & Resume Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Protection Register Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . . . . . 88 Buffer Enhanced Factory Program Flowchart and Pseudo Code . . . . . . . . . . . . . . . . . . . . 89 7/98 1 Summary description 1 M58LT128GST, M58LT128GSB Summary description The M58LT128GST and M58LT128GSB are 128 Mbit (8 Mbit x16) non-volatile Secure Flash memories. The devices may be erased electrically at block level and programmed in-system on a Word-byWord basis using a 1.7 to 2.0V VDD supply for the circuitry and a 2.7 to 3.6V VDDQ supply for the Input/Output pins. An optional 9V VPP power supply is provided to speed up factory programming. The devices feature an asymmetrical block architecture and are based on a multi-level cell technology. The memory array is organized as 131 blocks, and is divided into 8 Mbit banks. There are 15 banks each containing 8 main blocks of 64 KWords, and one parameter bank containing 4 parameter blocks of 16 KWords and 7 main blocks of 64 KWords. The Multiple Bank Architecture allows Dual Operations, while programming or erasing in one bank, read operations are possible in other banks. Only one bank at a time is allowed to be in program or erase mode. It is possible to perform burst reads that cross bank boundaries. The bank architecture is summarized in Table 2, and the memory maps are shown in Figure 3. The Parameter Blocks are located at the top of the memory address space for the M58LT128GST, and at the bottom for the M58LT128GSB. Each block can be erased separately. Erase can be suspended, in order to perform a program or read operation in any other block, and then resumed. Program can be suspended to read data at any memory location except for the one being programmed, and then resumed. Each block can be programmed and erased over 100,000 cycles using the supply voltage VDD. There is a Buffer Enhanced Factory programming command available to speed up programming. Program and erase commands are written to the Command Interface of the memory. An internal Program/Erase Controller takes care of the timings necessary for program and erase operations. The end of a program or erase operation can be detected and any error conditions identified in the Status Register. The command set required to control the memory is consistent with JEDEC standards. The device supports Synchronous Burst Read and Asynchronous Read and Page Read from all blocks of the memory array; at power-up the device is configured for Asynchronous Read. In Synchronous Burst Read mode, data is output on each clock cycle at frequencies of up to 52MHz. The Synchronous Burst Read operation can be suspended and resumed. The device features an Automatic Standby mode. When the bus is inactive during Asynchronous Read operations, the device automatically switches to the Automatic Standby mode. In this condition the power consumption is reduced to the standby value and the outputs are still driven. The M58LT128GST and M58LT128GSB are equipped with several features to increase data protection: 8/98 ● Hardware Protection: all blocks are protected from program and erase operations when the VPP ≤VPPLK . ● A full set of Software Security Features described in a dedicated Application Note. Please contact STMicroelectronics for further details. ● 64-bit Unique Device Identifier ● 2112 bits of User-Programmable OTP memory M58LT128GST, M58LT128GSB 1 Summary description The device includes 17 Protection Registers and 2 Protection Register locks, one for the first Protection Register and the other for the 16 One-Time-Programmable (OTP) Protection Registers of 128 bits each. The first Protection Register is divided into two segments: a 64 bit segment containing a unique device number written by ST, and a 64 bit segment One-TimeProgrammable (OTP) by the user. The user programmable segment can be permanently protected. Figure 4 shows the Protection Register Memory Map. The devices are offered in TBGA64 10 x 13mm, 1mm pitch. In order to meet environmental requirements, ST offers the M58LT128GST and M58LT128GSB in ECOPACK® package. ECOPACK package is Lead-free. The category of second Level Interconnect is marked on the package and on the inner box label, in compliance with JEDEC Standard JESD97. The maximum ratings related to soldering conditions are also marked on the inner box label. ECOPACK is an ST trademark. ECOPACK specifications are available at: www.st.com. The memories are supplied with all the bits erased (set to ’1’). Figure 1. Logic Diagram VDD VDDQ VPP 16 DQ0-DQ15 A0-A22 W E G WAIT M58LT128GSB M58LT128GST RP L K VSS VSSQ AI10259b 9/98 M58LT128GST, M58LT128GSB 1 Summary description Table 1. 10/98 Signal Names A0-A22 Address Inputs DQ0-DQ15 Data Input/Outputs, Command Inputs E Chip Enable G Output Enable W Write Enable RP Reset K Clock L Latch Enable WAIT Wait VDD Supply Voltage VDDQ Supply Voltage for Input/Output Buffers VPP Optional Supply Voltage for Fast Program & Erase and Write Protect VSS Ground VSSQ Ground Input/Output Supply NC Not Connected Internally M58LT128GST, M58LT128GSB Figure 2. 1 Summary description TBGA64 Connections (Top view through package) 1 2 3 4 5 6 7 8 A A0 A5 A7 VPP A12 VDD A17 A21 B A1 VSS A8 E A13 NC A18 WAIT C A2 A6 A9 A11 A14 NC A19 A20 D A3 A4 A10 RP NC NC A15 A16 E DQ8 DQ1 DQ9 DQ3 DQ4 NC DQ15 NC F K DQ0 DQ10 DQ11 DQ12 NC NC G G A22 NC DQ2 VDDQ DQ5 DQ6 DQ14 W H L NC VDD VSSQ DQ13 VSS DQ7 NC AI10270b Table 2. Bank Architecture Parameter Bank 8 Mbits 4 blocks of 16 KWords 7 blocks of 64 KWords Bank 1 8 Mbits - 8 blocks of 64 KWords Bank 2 8 Mbits - 8 blocks of 64 KWords Bank 3 8 Mbits - 8 blocks of 64 KWords ---- Main Blocks ---- Parameter Blocks ---- Bank Size ---- Number Bank 14 8 Mbits - 8 blocks of 64 KWords Bank 15 8 Mbits - 8 blocks of 64 KWords 11/98 M58LT128GST, M58LT128GSB 1 Summary description Figure 3. Memory Map M58LT128GSB - Bottom Boot Block Address lines A22-A0 M58LT128GST - Top Boot Block Address lines A22-A0 000000h 00FFFFh 64 KWord 070000h 07FFFFh 64 KWord Bank 15 600000h 60FFFFh 8 Main Blocks Parameter Bank 7E0000h 7EFFFFh 7F0000h 7F3FFFh 7FC000h 7FFFFFh 4 Parameter Blocks 16 KWord 64 KWord 7 Main Blocks 64 KWord 64 KWord 8 Main Blocks 64 KWord 64 KWord 8 Main Blocks Bank 2 170000h 17FFFFh 180000h 18FFFFh 64 KWord Bank 1 770000h 77FFFFh 780000h 78FFFFh 0F0000h 0FFFFFh 100000h 10FFFFh 64 KWord 8 Main Blocks 16 KWord Bank 1 64 KWord 8 Main Blocks 00C000h 00FFFFh 010000h 01FFFFh 070000h 07FFFFh 080000h 08FFFFh 64 KWord Bank 2 6F0000h 6FFFFFh 700000h 70FFFFh Parameter Bank 64 KWord Bank 3 670000h 67FFFFh 680000h 68FFFFh 000000h 003FFFh 8 Main Blocks 64 KWord 64 KWord 8 Main Blocks Bank 3 64 KWord 1F0000h 1FFFFFh 64 KWord 780000h 78FFFFh 64 KWord 7F0000h 7FFFFFh 64 KWord 64 KWord 7 Main Blocks 64 KWord 16 KWord 4 Parameter Blocks 16 KWord 8 Main Blocks Bank 15 AI10261 12/98 M58LT128GST, M58LT128GSB 2 2 Signal descriptions Signal descriptions See Figure 1: Logic Diagram and Table 1: Signal Names, for a brief overview of the signals connected to this device. 2.1 Address Inputs (A0-A22) The Address Inputs select the cells in the memory array to access during Bus Read operations. During Bus Write operations they control the commands sent to the Command Interface of the Program/Erase Controller. 2.2 Data Input/Output (DQ0-DQ15) The Data I/O output the data stored at the selected address during a Bus Read operation or input a command or the data to be programmed during a Bus Write operation. 2.3 Chip Enable (E) The Chip Enable input activates the memory control logic, input buffers, decoders and sense amplifiers. When Chip Enable is at VILand Reset is at VIH the device is in active mode. When Chip Enable is at VIH the memory is deselected, the outputs are high impedance and the power consumption is reduced to the stand-by level. 2.4 Output Enable (G) The Output Enable input controls data outputs during the Bus Read operation of the memory. 2.5 Write Enable (W) The Write Enable input controls the Bus Write operation of the memory’s Command Interface. The data and address inputs are latched on the rising edge of Chip Enable or Write Enable whichever occurs first. 2.6 Reset (RP) The Reset input provides a hardware reset of the memory. When Reset is at VIL, the memory is in reset mode: the outputs are high impedance and the current consumption is reduced to the Reset Supply Current IDD2. Refer to Table 20: DC Characteristics - Currents, for the value of IDD2. After Reset all blocks are in the Protected state and the Configuration Register is reset. When Reset is at VIH, the device is in normal operation. Exiting reset mode the device enters asynchronous read mode, but a negative transition of Chip Enable or Latch Enable is required to ensure valid data outputs. The Reset pin can be interfaced with 3V logic without any additional circuitry. It can be tied to VRPH (refer to Table 21: DC Characteristics - Voltages). 13/98 2 Signal descriptions 2.7 M58LT128GST, M58LT128GSB Latch Enable (L) Latch Enable latches the A0-A22 address bits on its rising edge. The address latch is transparent when Latch Enable is at VIL and it is inhibited when Latch Enable is at VIH. 2.8 Clock (K) The clock input synchronizes the memory to the microcontroller during synchronous read operations; the address is latched on a Clock edge (rising or falling, according to the configuration settings) when Latch Enable is at VIL. Clock is ignored during asynchronous read and in write operations. 2.9 Wait (WAIT) Wait is an output signal used during synchronous read to indicate whether the data on the output bus are valid. This output is high impedance when Chip Enable is at VIH or Reset is at VIL. It can be configured to be active during the wait cycle or one clock cycle in advance. The WAIT signal is forced deasserted when Output Enable is at VIH. 2.10 VDD Supply Voltage VDD provides the power supply to the internal core of the memory device. It is the main power supply for all operations (Read, Program and Erase). 2.10.1 VDDQ Supply Voltage VDDQ provides the power supply to the I/O pins and enables all Outputs to be powered independently from VDD. VDDQ can be tied to VDD or can use a separate supply. 2.11 VPP Program Supply Voltage The VPP pin is both a power supply and a write protect pin. The functions are selected by the voltage range applied to the pin. When VPP is lower than VPPLK, it is seen as a write protect pin protecting the whole memory array. Program and erase operations on all blocks are ignored while VPP is Low. When VPP is Higher than VPP1, the memory reverts to the previous protection state of the memory array. Program and erase operations can now modify the data in any block (refer to Table 21: DC Characteristics - Voltages for VPPLK and VPP1 values). VPP is only sampled at the beginning of a program or erase; a change in its value after the operation has started does not have any effect and program or erase operations continue. If VPP is in the range of VPPH it acts as a power supply pin. In this condition VPP must be stable until the Program/Erase algorithm is completed. The VPP pin must not be left floating or unconnected or the device may become unreliable. A 0.1µF capacitor should be connected between the VPP pin and the VSS Ground pin to decouple the current surges from the power supply. The PCB track widths must be sufficient to carry the currents required during Unlock Bypass Program, IPP. 14/98 M58LT128GST, M58LT128GSB 2.12 2 Signal descriptions VSS Ground VSS ground is the reference for the core supply. It must be connected to the system ground. 2.13 VSSQ Ground VSSQ ground is the reference for the input/output circuitry driven by VDDQ. VSSQ must be connected to VSS Note: Each device in a system should have VDD, VDDQ and VPP decoupled with a 0.1µF ceramic capacitor close to the pin (high frequency, inherently low inductance capacitors should be as close as possible to the package). See Figure 8: AC Measurement Load Circuit. The PCB track widths should be sufficient to carry the required VPP program and erase currents. 15/98 3 Bus operations 3 M58LT128GST, M58LT128GSB Bus operations There are six standard bus operations that control the device. These are Bus Read, Bus Write, Address Latch, Output Disable, Standby and Reset. See Table 3: Bus Operations, for a summary. Typically glitches of less than 5ns on Chip Enable or Write Enable are ignored by the memory and do not affect Bus Write operations. 3.1 Bus Read Bus Read operations are used to output the contents of the Memory Array, the Electronic Signature, the Status Register and the Common Flash Interface. Both Chip Enable and Output Enable must be at VIL in order to perform a read operation. The Chip Enable input should be used to enable the device. Output Enable should be used to gate data onto the output. The data read depends on the previous command written to the memory (see Command Interface section). See Figure 9, Figure 11 and Figure 12 Read AC Waveforms, and Table 22 and Table 23 Read AC Characteristics, for details of when the output becomes valid. 3.2 Bus Write Bus Write operations write Commands to the memory or latch Input Data to be programmed. A bus write operation is initiated when Chip Enable and Write Enable are at VIL with Output Enable at VIH. Commands, Input Data and Addresses are latched on the rising edge of Write Enable or Chip Enable, whichever occurs first. The addresses can also be latched prior to the write operation by toggling Latch Enable. In this case the Latch Enable should be tied to VIH during the bus write operation. See Figure 15 and Figure 16, Write AC Waveforms, and Table 24 and Table 25, Write AC Characteristics, for details of the timing requirements. 3.3 Address Latch Address latch operations input valid addresses. Both Chip enable and Latch Enable must be at VIL during address latch operations. The addresses are latched on the rising edge of Latch Enable. 3.4 Output Disable The outputs are high impedance when the Output Enable is at VIH. 3.5 Standby Standby disables most of the internal circuitry allowing a substantial reduction of the current consumption. The memory is in standby when Chip Enable and Reset are at VIH. The power consumption is reduced to the standby level IDD3 and the outputs are set to high impedance, independently from the Output Enable or Write Enable inputs. If Chip Enable switches to VIH during a program or erase operation, the device enters Standby mode when finished. 16/98 M58LT128GST, M58LT128GSB 3.6 3 Bus operations Reset During Reset mode the memory is deselected and the outputs are high impedance. The memory is in Reset mode when Reset is at VIL. The power consumption is reduced to the Reset level, independently from the Chip Enable, Output Enable or Write Enable inputs. If Reset is pulled to VSS during a Program or Erase, this operation is aborted and the memory content is no longer valid. Table 3. Bus Operations Operation(1) WAIT(2) E G W L RP Bus Read VIL VIL VIH VIH VIH Data Output Bus Write VIL VIH VIL VIH VIH Data Input Address Latch VIL VIH X VIL VIH Address Input Output Disable VIL VIH VIH VIH VIH Hi-Z Standby VIH X X X VIH Hi-Z Hi-Z X X X X VIL Hi-Z Hi-Z Reset DQ15-DQ0 1. X = Don't care. 2. WAIT signal polarity is configured using the Set Configuration Register command. 17/98 M58LT128GST, M58LT128GSB 4 Command Interface 4 Command Interface All Bus Write operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write operations. An internal Program/Erase Controller handles all timings and verifies the correct execution of the program and erase commands. The Program/Erase Controller provides a Status Register whose output may be read at any time to monitor the progress or the result of the operation. The Command Interface is reset to read mode when power is first applied, when exiting from Reset or whenever VDD is lower than VLKO. Command sequences must be followed exactly. Any invalid combination of commands will be ignored. Refer to Table 4: Command Codes, Table 5: Standard Commands, Table 6: Factory Program Command, and Appendix D: Command Interface state tables, for a summary of the Command Interface. Note: The security features are described in a dedicated Application Note. Please contact STMicroelectronics for further details. Table 4. Command Codes Hex Code 18/98 Command 03h Set Configuration Register Confirm 10h Alternative Program Setup 20h Block Erase Setup 40h Program Setup 50h Clear Status Register 70h Read Status Register 80h Buffer Enhanced Factory Program 90h Read Electronic Signature 98h Read CFI Query B0h Program/Erase Suspend C0h Program Register Program D0h Program/Erase Resume, Block Erase Confirm, or Buffer Program Confirm E8h Buffer Program FFh Read Array M58LT128GST, M58LT128GSB 4.1 4 Command Interface Read Array command The Read Array command returns the addressed bank to Read Array mode. One Bus Write cycle is required to issue the Read Array command. Once a bank is in Read Array mode, subsequent read operations will output the data from the memory array. A Read Array command can be issued to any banks while programming or erasing in another bank. If the Read Array command is issued to a bank currently executing a program or erase operation, the bank will return to Read Array mode but the program or erase operation will continue, however the data output from the bank is not guaranteed until the program or erase operation has finished. The read modes of other banks are not affected. 4.2 Read Status Register command The device contains a Status Register that is used to monitor program or erase operations. The Read Status Register command is used to read the contents of the Status Register for the addressed bank. One Bus Write cycle is required to issue the Read Status Register command. Once a bank is in Read Status Register mode, subsequent read operations will output the contents of the Status Register. The Status Register data is latched on the falling edge of the Chip Enable or Output Enable signals. Either Chip Enable or Output Enable must be toggled to update the Status Register data The Read Status Register command can be issued at any time, even during program or erase operations. The Read Status Register command will only change the read mode of the addressed bank. The read modes of other banks are not affected. Only Asynchronous Read and Single Synchronous Read operations should be used to read the Status Register. A Read Array command is required to return the bank to Read Array mode. See Table 9 for the description of the Status Register Bits. 4.3 Read Electronic Signature command The Read Electronic Signature command is used to read the Manufacturer and Device Codes, the Protection Status of the addressed bank, the Configuration Register and the Protection Register. One Bus Write cycle is required to issue the Read Electronic Signature command. Once a bank is in Read Electronic Signature mode, subsequent read operations in the same bank will output the Manufacturer Code, the Device Code, the Protection Status of the addressed bank, or the Configuration Register (see Table 7). The Read Electronic Signature command can be issued at any time, even during program or erase operations, except during Protection Register Program operations. Dual operations between the Parameter bank and the Electronic Signature location are not allowed (see Table 15: Dual Operation Limitations for details). If a Read Electronic Signature command is issued to a bank that is executing a program or erase operation the bank will go into Read Electronic Signature mode. Subsequent Bus Read 19/98 4 Command Interface M58LT128GST, M58LT128GSB cycles will output the Electronic Signature data and the Program/Erase controller will continue to program or erase in the background. The Read Electronic Signature command will only change the read mode of the addressed bank. The read modes of other banks are not affected. Only Asynchronous Read and Single Synchronous Read operations should be used to read the Electronic Signature. A Read Array command is required to return the bank to Read Array mode. 4.4 Read CFI Query command The Read CFI Query command is used to read data from the Common Flash Interface (CFI). One Bus Write cycle is required to issue the Read CFI Query command. Once a bank is in Read CFI Query mode, subsequent Bus Read operations in the same bank read from the Common Flash Interface. The Read CFI Query command can be issued at any time, even during program or erase operations. If a Read CFI Query command is issued to a bank that is executing a program or erase operation the bank will go into Read CFI Query mode. Subsequent Bus Read cycles will output the CFI data and the Program/Erase controller will continue to program or erase in the background. The Read CFI Query command will only change the read mode of the addressed bank. The read modes of other banks are not affected. Only Asynchronous Read and Single Synchronous Read operations should be used to read from the CFI. A Read Array command is required to return the bank to Read Array mode. Dual operations between the Parameter Bank and the CFI memory space are not allowed (see Table 15: Dual Operation Limitations for details). See Appendix B: Common Flash Interface, Table 36, Table 37, Table 38, Table 39, Table 40, Table 42, Table 43, Table 44 and Table 45 for details on the information contained in the Common Flash Interface memory area. 4.5 Clear Status Register command The Clear Status Register command can be used to reset (set to ‘0’) all error bits (SR1, 3, 4 and 5) in the Status Register. One Bus Write cycle is required to issue the Clear Status Register command. The Clear Status Register command does not affect the read mode of the bank. The error bits in the Status Register do not automatically return to ‘0’ when a new command is issued. The error bits in the Status Register should be cleared before attempting a new program or erase command. 20/98 M58LT128GST, M58LT128GSB 4.6 4 Command Interface Block Erase command The Block Erase command is used to erase a block. It sets all the bits within the selected block to ’1’. All previous data in the block is lost. If the block is protected then the erase operation will abort, the data in the block will not be changed and the Status Register will output the error. Two Bus Write cycles are required to issue the command. 1. The first bus cycle sets up the Block Erase command. 2. The second latches the block address and starts the Program/Erase Controller. If the second bus cycle is not the Block Erase Confirm code, Status Register bits SR4 and SR5 are set and the command is aborted. Once the command is issued the bank enters Read Status Register mode and any read operation within the addressed bank will output the contents of the Status Register. A Read Array command is required to return the bank to Read Array mode. During Block Erase operations the bank containing the block being erased will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command, all other commands will be ignored. The Block Erase operation aborts if Reset, RP, goes to VIL. As data integrity cannot be guaranteed when the Block Erase operation is aborted, the block must be erased again. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being erased. Typical Erase times are given in Table 16: Program/Erase Times and Endurance Cycles. See Appendix C, Figure 22: Block Erase Flowchart and Pseudo Code, for a suggested flowchart for using the Block Erase command. 4.7 Program command The program command is used to program a single Word to the memory array. Two Bus Write cycles are required to issue the Program Command. 1. The first bus cycle sets up the Program command. 2. The second latches the address and data to be programmed and starts the Program/ Erase Controller. Once the programming has started, read operations in the bank being programmed output the Status Register content. During a Program operation, the bank containing the Word being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command, all other commands will be ignored. A Read Array command is required to return the bank to Read Array mode. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being programmed. Typical Program times are given in Table 16: Program/Erase Times and Endurance Cycles. The Program operation aborts if Reset, RP, goes to VIL. As data integrity cannot be guaranteed when the Program operation is aborted, the Word must be reprogrammed. 21/98 4 Command Interface M58LT128GST, M58LT128GSB See Appendix C, Figure 19: Program Flowchart and Pseudo Code, for the flowchart for using the Program command. 4.8 Buffer Program command The Buffer Program Command makes use of the device’s 32-Word Write Buffer to speed up programming. Up to 32 Words can be loaded into the Write Buffer. The Buffer Program command dramatically reduces in-system programming time compared to the standard nonbuffered Program command. Four successive steps are required to issue the Buffer Program command. 1. The first Bus Write cycle sets up the Buffer Program command. The setup code can be addressed to any location within the targeted block. After the first Bus Write cycle, read operations in the bank will output the contents of the Status Register. Status Register bit SR7 should be read to check that the buffer is available (SR7 = 1). If the buffer is not available (SR7 = 0), re-issue the Buffer Program command to update the Status Register contents. 2. The second Bus Write cycle sets up the number of Words to be programmed. Value n is written to the same block address, where n+1 is the number of Words to be programmed. 3. Use n+1 Bus Write cycles to load the address and data for each Word into the Write Buffer. Addresses must lie within the range from the start address to the start address + n. Optimum performance is obtained when the start address corresponds to a 32 Word boundary. If the start address is not aligned to a 32 word boundary, the total programming time is doubled 4. The final Bus Write cycle confirms the Buffer Program command and starts the program operation. All the addresses used in the Buffer Program operation must lie within the same block. Invalid address combinations or failing to follow the correct sequence of Bus Write cycles will set an error in the Status Register and abort the operation without affecting the data in the memory array. If the Status Register bits SR4 and SR5 are set to '1', the Buffer Program Command is not accepted. Clear the Status Register before re-issuing the command. If the block being programmed is protected an error will be set in the Status Register and the operation will abort without affecting the data in the memory array. During Buffer Program operations the bank being programmed will only accept the Read Array, Read Status Register, Read Electronic Signature, Read CFI Query and the Program/Erase Suspend command, all other commands will be ignored. Refer to Dual Operations section for detailed information about simultaneous operations allowed in banks not being programmed. See Appendix C, Figure 20: Buffer Program Flowchart and Pseudo Code, for a suggested flowchart on using the Buffer Program command. 22/98 M58LT128GST, M58LT128GSB 4.9 4 Command Interface Buffer Enhanced Factory Program command The Buffer Enhanced Factory Program command has been specially developed to speed up programming in manufacturing environments where the programming time is critical. It is used to program one or more Write Buffer(s) of 32 Words to a block. Once the device enters Buffer Enhanced Factory Program mode, the Write Buffer can be reloaded any number of times as long as the address remains within the same block. Only one block can be programmed at a time. The use of the Buffer Enhanced Factory Program command requires certain operating conditions: ● The targeted block must be unprotected. if it is protected, the user must return the device to read mode. ● VPP must be set to VPPH. ● VDD must be within operating range. ● Ambient temperature TA must be 30°C ± 10°C. ● The start address must be aligned with the start of a 32 Word buffer boundary. ● The address must remain the Start Address throughout programming. Dual operations are not supported during the Buffer Enhanced Factory Program operation and the command cannot be suspended. The Buffer Enhanced Factory Program Command consists of three phases: the Setup Phase, the Program and Verify Phase, and the Exit Phase, See Appendix C, Figure 25: Buffer Enhanced Factory Program Flowchart and Pseudo Code, for a suggested flowchart on using the Buffer Program command and to Table 6: Factory Program Command for details on the Buffer Enhanced Factory Program command. 4.9.1 Setup phase The Buffer Enhanced Factory Program command requires two Bus Write cycles to initiate the command. 1. The first Bus Write cycle sets up the Buffer Enhanced Factory Program command. 2. The second Bus Write cycle confirms the command. After the confirm command is issued, read operations output the contents of the Status Register. The read Status Register command must not be issued as it will be interpreted as data to program. The Status Register P/E.C. Bit SR7 should be read to check that the P/E.C. is ready to proceed to the next phase. If an error is detected, SR4 goes high (set to ‘1’) and the Buffer Enhanced Factory Program operation is terminated. See Status Register section for details on the error. 23/98 4 Command Interface 4.9.2 M58LT128GST, M58LT128GSB Program and Verify phase The Program and Verify Phase requires 32 cycles to program the 32 Words to the Write Buffer. The data is stored sequentially, starting at the first address of the Write Buffer, until the Write Buffer is full (32 Words). To program less than 32 Words, the remaining Words should be programmed with FFFFh. Three successive steps are required to issue and execute the Program and Verify Phase of the command. 1. Use one Bus Write operation to latch the Start Address and the first Word to be programmed. The Status Register Bank Write Status bit SR0 should be read to check that the P/E.C. is ready for the next Word. 2. Each subsequent Word to be programmed is latched with a new Bus Write operation. The address must remain the Start Address as the P/E.C. increments the address location.If any address that is not in the same block as the Start Address is given, the Program and Verify Phase terminates. Status Register bit SR0 should be read between each Bus Write cycle to check that the P/E.C. is ready for the next Word. 3. Once the Write Buffer is full, the data is programmed sequentially to the memory array. After the program operation the device automatically verifies the data and reprograms if necessary. The Program and Verify phase can be repeated, without re-issuing the command, to program additional 32 Word locations as long as the address remains in the same block. 4. Finally, after all Words, or the entire block have been programmed, write one Bus Write operation to any address outside the block containing the Start Address, to terminate Program and Verify Phase. Status Register bit SR0 must be checked to determine whether the program operation is finished. The Status Register may be checked for errors at any time but it must be checked after the entire block has been programmed. 4.9.3 Exit phase Status Register P/E.C. bit SR7 set to ‘1’ indicates that the device has exited the Buffer Enhanced Factory Program operation and returned to Read Status Register mode. A full Status Register check should be done to ensure that the block has been successfully programmed. See the section on the Status Register for more details. For optimum performance the Buffer Enhanced Factory Program command should be limited to a maximum of 100 program/erase cycles per block. If this limit is exceeded the internal algorithm will continue to work properly but some degradation in performance is possible. Typical program times are given in Table 16 See Appendix C, Figure 25: Buffer Enhanced Factory Program Flowchart and Pseudo Code, for a suggested flowchart on using the Buffer Enhanced Factory Program command. 24/98 M58LT128GST, M58LT128GSB 4.10 4 Command Interface Program/Erase Suspend command The Program/Erase Suspend command is used to pause a Program or Block Erase operation. The command can be addressed to any bank. The Program/Erase Resume command is required to restart the suspended operation. One bus write cycle is required to issue the Program/Erase Suspend command. Once the Program/Erase Controller has paused bits SR7, SR6 and/ or SR2 of the Status Register will be set to ‘1’. The following commands are accepted during Program/Erase Suspend: ● Program/Erase Resume ● Read Array (data from erase-suspended block or program-suspended Word is not valid) ● Read Status Register ● Read Electronic Signature ● Read CFI Query. In addition, if the suspended operation was a Block Erase then the following commands are also accepted: ● Clear Status Register ● Program (except in erase-suspended block) ● Buffer Program (except in erase suspended blocks) It is possible to accumulate multiple suspend operations. For example: suspend an erase operation, start a program operation, suspend the program operation, then read the array. If a Program command is issued during a Block Erase Suspend, the erase operation cannot be resumed until the program operation has completed. The Program/Erase Suspend command does not change the read mode of the banks. If the suspended bank was in Read Status Register, Read Electronic signature or Read CFI Query mode the bank remains in that mode and outputs the corresponding data. Refer to Dual Operations section for detailed information about simultaneous operations allowed during Program/Erase Suspend. During a Program/Erase Suspend, the device can be placed in standby mode by taking Chip Enable to VIH. Program/erase is aborted if Reset, RP, goes to VIL. See Appendix C, Figure 21: Program Suspend & Resume Flowchart and Pseudo Code, and Figure 23: Erase Suspend & Resume Flowchart and Pseudo Code, for flowcharts for using the Program/Erase Suspend command. 4.11 Program/Erase Resume command The Program/Erase Resume command is used to restart the program or erase operation suspended by the Program/Erase Suspend command. One Bus Write cycle is required to issue the command. The command can be issued to any address. The Program/Erase Resume command does not change the read mode of the banks. If the suspended bank was in Read Status Register, Read Electronic signature or Read CFI Query mode the bank remains in that mode and outputs the corresponding data. 25/98 4 Command Interface M58LT128GST, M58LT128GSB If a Program command is issued during a Block Erase Suspend, then the erase cannot be resumed until the program operation has completed. See Appendix C, Figure 21: Program Suspend & Resume Flowchart and Pseudo Code, and Figure 23: Erase Suspend & Resume Flowchart and Pseudo Code, for flowcharts for using the Program/Erase Resume command. 4.11.1 Protection Register Program command The Protection Register Program command is used to program the user One-TimeProgrammable (OTP) segments of the Protection Register and the two Protection Register Locks. The device features 16 OTP segments of 128 bits and one OTP segment of 64 bits, as shown in Figure 4: Protection Register Map. The segments are programmed one Word at a time. When shipped all bits in the segment are set to ‘1’. The user can only program the bits to ‘0’. Two Bus Write cycles are required to issue the Protection Register Program command. 1. The first bus cycle sets up the Protection 2. Register Program command. 3. The second latches the address and data to be programmed to the Protection Register and starts the Program/Erase Controller. Read operations to the bank being programmed output the Status Register content after the program operation has started. Attempting to program a previously protected Protection Register will result in a Status Register error. The Protection Register Program cannot be suspended. Dual operations between the Parameter Bank and the Protection Register memory space are not allowed (see Table 15: Dual Operation Limitations for details). The two Protection Register Locks are used to protect the OTP segments from further modification. The protection of the OTP segments is not reversible. Refer to Figure 4: Protection Register Map, and Table 8: Protection Register Lock Bits, for details on the Lock bits. See Appendix C, Figure 24: Protection Register Program Flowchart and Pseudo Code, for a flowchart for using the Protection Register Program command. 4.12 Set Configuration Register command The Set Configuration Register command is used to write a new value to the Configuration Register. Two Bus Write cycles are required to issue the Set Configuration Register command. 1. The first cycle sets up the Set Configuration Register command and the address corresponding to the Configuration Register content. 2. The second cycle writes the Configuration Register data and the confirm command. The Configuration Register data must be written as an address during the bus write cycles, that is DQ0 = CR0, DQ1 = CR1, …, DQ15 = CR15. Addresses A0-A22 are ignored. Read operations output the array content after the Set Configuration Register command is issued. 26/98 M58LT128GST, M58LT128GSB 4 Command Interface The Read Electronic Signature command is required to read the updated contents of the Configuration Register. Table 5. Standard Commands Commands Cycles Bus Operations(1) 1st Cycle 2nd Cycle Op. Add Data Op. Add Data Read Array 1+ Write BKA FFh Read WA RD Read Status Register 1+ Write X 70h Read BKA(2) SRD Read Electronic Signature 1+ Write X 90h Read BKA(2) ESD Read CFI Query 1+ Write BKA 98h Read BKA(2) QD Clear Status Register 1 Write BKA 50h Block Erase 2 Write BKA or BA(3) 20h Write BA D0h Program 2 Write BKA or WA(3) 40h or 10h Write WA PD Write BA E8h Write BA n Write PA1 PD1 Write PA2 PD2 Write PAn+1(4) PDn+1(4) Write X D0h Write PRA PRD Write CRD 03h Buffer Program n+4 Program/Erase Suspend 1 Write X B0h Protection Register Program 2 Write PRA C0h Program/Erase Resume 1 Write X D0h Set Configuration Register 2 Write CRD 60h 1. X = Don't Care, WA=Word Address in targeted bank, RD=Read Data, SRD=Status Register Data, ESD=Electronic Signature Data, QD=Query Data, BA=Block Address, BKA= Bank Address, PD=Program Data, PRA = Protection Register Address, PRD = Protection Register Data, CRD=Configuration Register Data. 2. Must be same bank as in the first cycle. The signature addresses are listed in Table 7 3. Any address within the bank can be used. 4. n+1 is the number of Words to be programmed. 27/98 M58LT128GST, M58LT128GSB 4 Command Interface Table 6. Factory Program Command Command Cycles Bus Write Operations(1) Phase 2nd 3rd Add Data Add Data Add 2 BKA or WA(2) 80h WA1 D0h ≥32 WA1 PD1 WA1 PD2 1 NOT BA1(4) X Setup Buffer Enhanced Program/ Factory Verify(3) Program 1st Exit WA1 Final -1 Final Data Add Data Add Data PD3 WA1 PD31 WA1 PD32 1. WA=Word Address in targeted bank, BKA= Bank Address, PD=Program Data, BA=Block Address, X = Don’t Care. 2. Any address within the bank can be used. 3. The Program/Verify phase can be executed any number of times as long as the data is to be programmed to the same block. 4. WA1 is the Start Address, NOT BA1 = Not Block Address of WA1. Table 7. Electronic Signature Codes Code Address (h) Data (h) Manufacturer Code Bank Address + 00 0020 Top Bank Address + 01 88C6h (M58LT128GST) Bottom Bank Address + 01 88C7h (M58LT128GSB) Die Revision Code Block Address + 03 DRC(1) Configuration Register Bank Address + 05 CR(1) Device Code ST Factory Default Protection Register PR0 OTP Area Permanently Locked bit 0 = ‘0’ Bank Address + 80 bit 1 = ‘0’ Bank Address + 81 Bank Address + 84 Unique Device Number Bank Address + 85 Bank Address + 88 OTP Area Protection Register PR1 through PR16 Lock Bank Address + 89 PRLD Protection Registers PR1-PR16 Bank Address + 8A Bank Address + 109 OTP Area Protection Register PR0 1. CR = Configuration Register, DRC = Die Revision Code. 28/98 M58LT128GST, M58LT128GSB Figure 4. 4 Command Interface Protection Register Map PROTECTION REGISTERS 109h PR16 User Programmable OTP 102h 91h PR1 User Programmable OTP 8Ah Protection Register Lock 89h 88h 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 PR0 User Programmable OTP 85h 84h Unique device number 81h 80h Protection Register Lock 1 0 AI07563 29/98 M58LT128GST, M58LT128GSB 4 Command Interface Table 8. Protection Register Lock Bits Lock Description Number Protection Register Lock 1 Protection Register Lock 2 30/98 Address Bits Bit 0 Read-only bit preprogrammed to ‘0’ protect Unique Device Number (address 81h to 84h in PR0) Bit 1 protects 64bits of OTP segment (address 85h to 88h in PR0) when set to ‘0’ Default Value is ‘1’ Bit 0 protects 128bits of OTP segment PR1 Bit 1 protects 128bits of OTP segment PR2 Bit 2 protects 128bits of OTP segment PR3 --- --- Bit 13 protects 128bits of OTP segment PR14 Bit 14 protects 128bits of OTP segment PR15 Bit 15 protects 128bits of OTP segment PR16 80h 89h M58LT128GST, M58LT128GSB 5 5 Status Register Status Register The Status Register provides information on the current or previous program or erase operations. Issue a Read Status Register command to read the contents of the Status Register, refer to Read Status Register Command section for more details. To output the contents, the Status Register is latched and updated on the falling edge of the Chip Enable or Output Enable signals and can be read until Chip Enable or Output Enable returns to VIH. The Status Register can only be read using single Asynchronous or Single Synchronous reads. Bus Read operations from any address within the bank, always read the Status Register during program and erase operations. The various bits convey information about the status and any errors of the operation. Bits SR7, SR6, SR2 and SR0 give information on the status of the device and are set and reset by the device. Bits SR5, SR4, SR3 and SR1 give information on errors, they are set by the device but must be reset by issuing a Clear Status Register command or a hardware reset. If an error bit is set to ‘1’ the Status Register should be reset before issuing another command. Refer to Table 9: Status Register Bits in conjunction with the following text descriptions. 5.1 Program/Erase Controller Status Bit (SR7) The Program/Erase Controller Status bit indicates whether the Program/Erase Controller is active or inactive in any bank. When the Program/Erase Controller Status bit is Low (set to ‘0’), the Program/Erase Controller is active; when the bit is High (set to ‘1’), the Program/Erase Controller is inactive, and the device is ready to process a new command. The Program/Erase Controller Status bit is Low immediately after a Program/Erase Suspend command is issued until the Program/Erase Controller pauses. After the Program/Erase Controller pauses the bit is High. 5.2 Erase Suspend Status Bit (SR6) The Erase Suspend Status bit indicates that an erase operation has been suspended in the addressed block. When the Erase Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. The Erase Suspend Status bit should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). SR6 is set within the Erase Suspend Latency time of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Erase Suspend Status bit returns Low. 31/98 5 Status Register 5.3 M58LT128GST, M58LT128GSB Erase Status Bit (SR5) The Erase Status bit is used to identify if there was an error during a block or bank erase operation. When the Erase Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the block or bank and still failed to verify that it has erased correctly. The Erase Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). Once set High, the Erase Status bit must be set Low by a Clear Status Register command or a hardware reset before a new erase command is issued, otherwise the new command will appear to fail. 5.4 Program Status Bit (SR4) The Program Status bit is used to identify if there was an error during a program operation. The Program Status bit should be read once the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). When the Program Status bit is High (set to ‘1’), the Program/Erase Controller has applied the maximum number of pulses to the Word and still failed to verify that it has programmed correctly. Attempting to program a '1' to an already programmed bit while VPP = VPPH will also set the Program Status bit High. If VPP is different from VPPH, SR4 remains Low (set to '0') and the attempt is not shown. Once set High, the Program Status bit must be set Low by a Clear Status Register command or a hardware reset before a new program command is issued, otherwise the new command will appear to fail. 5.5 VPP Status Bit (SR3) The VPP Status bit is used to identify an invalid voltage on the VPP pin during program and erase operations. The VPP pin is only sampled at the beginning of a program or erase operation. Program and erase operations are not guaranteed if VPP becomes invalid during an operation. When the VPP Status bit is Low (set to ‘0’), the voltage on the VPP pin was sampled at a valid voltage. when the VPP Status bit is High (set to ‘1’), the VPP pin has a voltage that is below the VPP Lockout Voltage, VPPLK, the memory is protected and program and erase operations cannot be performed. Once set High, the VPP Status bit must be set Low by a Clear Status Register command or a hardware reset before a new program or erase command is issued, otherwise the new command will appear to fail. 32/98 M58LT128GST, M58LT128GSB 5.6 5 Status Register Program Suspend Status Bit (SR2) The Program Suspend Status bit indicates that a program operation has been suspended in the addressed block. The Program Suspend Status bit should only be considered valid when the Program/Erase Controller Status bit is High (Program/Erase Controller inactive). When the Program Suspend Status bit is High (set to ‘1’), a Program/Erase Suspend command has been issued and the memory is waiting for a Program/Erase Resume command. SR2 is set within the Program Suspend Latency time of the Program/Erase Suspend command being issued therefore the memory may still complete the operation rather than entering the Suspend mode. When a Program/Erase Resume command is issued the Program Suspend Status bit returns Low. SR1. Reserved. 5.7 Bank Write/Multiple Word Program Status Bit (SR0) The Bank Write Status bit indicates whether the addressed bank is programming or erasing. In Buffer Enhanced Factory Program mode the Multiple Word Program bit shows if the device is ready to accept a new Word to be programmed to the memory array. The Bank Write Status bit should only be considered valid when the Program/Erase Controller Status SR7 is Low (set to ‘0’). When both the Program/Erase Controller Status bit and the Bank Write Status bit are Low (set to ‘0’), the addressed bank is executing a program or erase operation. When the Program/Erase Controller Status bit is Low (set to ‘0’) and the Bank Write Status bit is High (set to ‘1’), a program or erase operation is being executed in a bank other than the one being addressed. In Buffer Enhanced Factory Program mode if Multiple Word Program Status bit is Low (set to ‘0’), the device is ready for the next Word, if the Multiple Word Program Status bit is High (set to ‘1’) the device is not ready for the next Word. For further details on how to use the Status Register, see the Flowcharts and Pseudo codes provided in Appendix C. 33/98 M58LT128GST, M58LT128GSB 5 Status Register Table 9. Bit Status Register Bits Name SR7 P/E.C. Status SR6 Erase Suspend Status SR5 Erase Status SR4 Program Status SR3 VPP Status SR2 Program Suspend Status Type Logic Level Definition '1' Ready '0' Busy '1' Erase Suspended '0' Erase In progress or Completed '1' Erase Error '0' Erase Success '1' Program Error '0' Program Success '1' VPP Invalid, Abort '0' VPP OK '1' Program Suspended '0' Program In Progress or Completed Status Status Error Error Error Status SR1 Reserved SR7 = ‘1’ Not Allowed '1' SR7 = ‘0’ Bank Write Status Status Program or erase operation in a bank other than the addressed bank SR7 = ‘1’ No Program or erase operation in the device '0' SR7 = ‘0’ Program or erase operation in addressed bank SR0 SR7 = ‘1’ Not Allowed Multiple Word Program Status (Enhanced Factory Program mode) '1' SR7 = ‘0’ the device is NOT ready for the next Word Status SR7 = ‘1’ the device is exiting from BEFP '0' SR7 = ‘0’ 1. Logic level '1' is High, '0' is Low. 34/98 the device is ready for the next Word M58LT128GST, M58LT128GSB 6 6 Configuration Register Configuration Register The Configuration Register is used to configure the type of bus access that the memory will perform. Refer to Read Modes section for details on read operations. The Configuration Register is set through the Command Interface using the Set Configuration Register command. After a reset or power-up the device is configured for asynchronous read (CR15 = 1). The Configuration Register bits are described in Table 10 They specify the selection of the burst length, burst type, burst X latency and the read operation. Refer to Figure 5 and Figure 6 for examples of synchronous burst configurations. 6.1 Read Select Bit (CR15) The Read Select bit, CR15, is used to switch between Asynchronous and Synchronous Read operations. When the Read Select bit is set to ’1’, read operations are asynchronous; when the Read Select bit is set to ’0’, read operations are synchronous. Synchronous Burst Read is supported in both parameter and main blocks and can be performed across banks. On reset or power-up the Read Select bit is set to ’1’ for asynchronous access. 6.2 X-Latency Bits (CR13-CR11) The X-Latency bits are used during Synchronous Read operations to set the number of clock cycles between the address being latched and the first data becoming available. For correct operation the X-Latency bits can only assume the values in Table 10: Configuration Register. The correspondence between X-Latency settings and the maximum sustainable frequency must be calculated taking into account some system parameters. Two conditions must be satisfied: 1. Depending on whether tAVK_CPU or tDELAY is supplied either one of the following two equations must be satisfied: (n + 1) tK ≥ tAVQV - tAVK_CPU + tQVK_CPU (n + 2) tK ≥ tAVQV + tDELAY + tQVK_CPU 2. and also tK > tKQV + tQVK_CPU where ● n is the chosen X-Latency configuration code ● tK is the clock period ● tAVK_CPU is clock to address valid, L Low, or E Low, whichever occurs last ● tDELAY is address valid, L Low, or E Low to clock, whichever occurs last ● tQVK_CPU is the data setup time required by the system CPU, ● tKQV is the clock to data valid time ● tAVQV is the random access time of the device. 35/98 6 Configuration Register M58LT128GST, M58LT128GSB Refer to Figure 5: X-Latency and Data Output Configuration Example. 6.3 Wait Polarity Bit (CR10) The Wait Polarity bit is used to set the polarity of the Wait signal used in Synchronous Burst Read mode. During Synchronous Burst Read mode the Wait signal indicates whether the data output are valid or a WAIT state must be inserted. When the Wait Polarity bit is set to ‘0’ the Wait signal is active Low. When the Wait Polarity bit is set to ‘1’ the Wait signal is active High. 6.4 Data Output Configuration Bit (CR9) The Data Output Configuration bit is used to configure the output to remain valid for either one or two clock cycles during synchronous mode. When the Data Output Configuration Bit is ’0’ the output data is valid for one clock cycle, when the Data Output Configuration Bit is ’1’ the output data is valid for two clock cycles. The Data Output Configuration must be configured using the following condition: ● tK > tKQV + tQVK_CPU where ● tK is the clock period ● tQVK_CPU is the data setup time required by the system CPU ● tKQV is the clock to data valid time. If this condition is not satisfied, the Data Output Configuration bit should be set to ‘1’ (two clock cycles). Refer to Figure 5: X-Latency and Data Output Configuration Example. 6.5 Wait Configuration Bit (CR8) The Wait Configuration bit is used to control the timing of the Wait output pin, WAIT, in Synchronous Burst Read mode. When WAIT is asserted, Data is Not Valid and when WAIT is deasserted, Data is Valid. When the Wait Configuration bit is Low (set to ’0’) the Wait output pin is asserted during the WAIT state. When the Wait Configuration bit is High (set to ’1’), the Wait output pin is asserted one data cycle before the WAIT state. 6.6 Burst Type Bit (CR7) The Burst Type bit determines the sequence of addresses read during Synchronous Burst Reads. The Burst Type bit is High (set to ’1’), as the memory outputs from sequential addresses only. See Table 11: Burst Type Definition, for the sequence of addresses output from a given starting address in sequential mode. 36/98 M58LT128GST, M58LT128GSB 6.7 6 Configuration Register Valid Clock Edge Bit (CR6) The Valid Clock Edge bit, CR6, is used to configure the active edge of the Clock, K, during synchronous read operations. When the Valid Clock Edge bit is Low (set to ’0’) the falling edge of the Clock is the active edge. When the Valid Clock Edge bit is High (set to ’1’) the rising edge of the Clock is the active edge. 6.8 Wrap Burst Bit (CR3) The Wrap Burst bit, CR3, is used to select between wrap and no wrap. Synchronous burst reads can be confined inside the 4, 8 or 16 Word boundary (wrap) or overcome the boundary (no wrap). When the Wrap Burst bit is Low (set to ‘0’) the burst read wraps. When it is High (set to ‘1’) the burst read does not wrap. 6.9 Burst length Bits (CR2-CR0) The Burst Length bits are used to set the number of Words to be output during a Synchronous Burst Read operation as result of a single address latch cycle. They can be set for 4 Words, 8 Words, 16 Words or continuous burst, where all the Words are read sequentially. In continuous burst mode the burst sequence can cross bank boundaries. In continuous burst mode, in 4, 8 or 16 Words no-wrap, depending on the starting address, the device asserts the WAIT signal to indicate that a delay is necessary before the data is output. If the starting address is aligned to an 8 Word boundary no WAIT states are needed and the WAIT output is not asserted. If the starting address is not aligned to the 8 Word boundary, WAIT will be asserted when the burst sequence crosses the first 16 Word boundary to indicate that the device needs an internal delay to read the successive Words in the array. In the worst case, the number of WAIT states is one clock cycle less than the latency setting. The exact number is reported in Table 12: Wait at the Boundary. WAIT will be asserted only once during a continuous burst access. See also Table 11: Burst Type Definition. CR14, CR5 and CR4 are reserved for future use. 37/98 M58LT128GST, M58LT128GSB 6 Configuration Register Table 10. Configuration Register Bit CR15 CR14 CR13-CR11 Description Value Description 0 Synchronous Read 1 Asynchronous Read (Default at power-on) 010 2 clock latency(1) 011 3 clock latency 100 4 clock latency 101 5 clock latency 110 6 clock latency 111 7 clock latency (default) Read Select Reserved X-Latency Other configurations reserved CR10 CR9 CR8 CR7 CR6 CR5-CR4 CR3 CR2-CR0 0 WAIT is active Low (default) 1 WAIT is active High 0 Data held for one clock cycle 1 Data held for two clock cycles (default)(1) 0 WAIT is active during WAIT state (default) 1 WAIT is active one data cycle before WAIT state(1) 0 Reserved 1 Sequential (default) 0 Falling Clock edge 1 Rising Clock edge (default) 0 Wrap 1 No Wrap (default) 001 4 Words 010 8 Words 011 16 Words 111 Continuous (default) Wait Polarity Data Output Configuration Wait Configuration Burst Type Valid Clock Edge Reserved Wrap Burst Burst Length 1. The combination X-Latency=2, Data held for two clock cycles and Wait active one data cycle before the WAIT state is not supported. 38/98 M58LT128GST, M58LT128GSB Mode Table 11. Start Add. 6 Configuration Register Burst Type Definition Sequential Continuous Burst 4 Words 8 Words 16 Words 0 0-1-2-3 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7-8-9-10-11-12-13-1415 0-1-2-3-4-5-6... 1 1-2-3-0 1-2-3-4-5-6-7-0 1-2-3-4-5-6-7-8-9-10-11-12-13-1415-0 1-2-3-4-5-6-7... 2 2-3-0-1 2-3-4-5-6-7-0-1 2-3-4-5-6-7-8-9-10-11-12-13-14-150-1 2-3-4-5-6-7-8... 3 3-0-1-2 3-4-5-6-7-0-1-2 3-4-5-6-7-8-9-10-11-12-13-14-15-01-2 3-4-5-6-7-8-9... 7-4-5-6 7-0-1-2-3-4-5-6 7-8-9-10-11-12-13-14-15-0-1-2-3-45-6 7-8-9-10-11-12-13... 12 12-13-14-15 12-13-14-15-8-9-1011 12-13-14-15-0-1-2-3-4-5-6-7-8-9-1011 12-13-14-15-16-17... 13 13-14-15-12 13-14-15-8-9-10-1112 13-14-15-0-1-2-3-4-5-6-7-8-9-10-1112 13-14-15-16-17-18... 14 14-15-12-13 14-15-8-9-10-11-1213 14-15-0-1-2-3-4-5-6-7-8-9-10-11-1213 14-15-16-17-18-19... 15 15-12-13-14 15-8-9-10-11-12-1314 15-0-1-2-3-4-5-6-7-8-9-10-11-12-1314 15-16-17-18-19-20... 0 0-1-2-3 0-1-2-3-4-5-6-7 0-1-2-3-4-5-6-7-8-9-10-11-12-13-1415 1 1-2-3-4 1-2-3-4-5-6-7-8 1-2-3-4-5-6-7-8--9-10-11-12-13-1415-16 2 2-3-4-5 2-3-4-5-6-7-8-9... 2-3-4-5--6-7-8-9-10-11-12-13-14-1516-17 3 3-4-5-6 3-4-5-6-7-8-9-10 3-4-5-6-7-8-9-10-11-12-13-14-1516-17-18 7-8-9-10 7-8-9-10-11-12-13-14 7-8-9-10-11-12-13-14-15-16-17-1819-20-21-22 12 12-13-14-15 12-13-14-15-16-1718-19 12-13-14-15-16-17-18-19-20-21-2223-24-25-26-27 13 13-14-15-16 13-14-15-16-17-1819-20 13-14-15-16-17-18-19-20-21-22-2324-25-26-27-28 14 14-15-16-17 14-15-16-17-18-1920-21 14-15-16-17-18-19-20-21-22-23-2425-26-27-28-29 15 15-16-17-18 15-16-17-18-19-2021-22 15-16-17-18-19-20-21-22-23-24-2526-27-28-29-30 Wrap ... 7 ... No-wrap ... 7 ... Same as for Wrap (Wrap /No Wrap has no effect on Continuous Burst) 39/98 M58LT128GST, M58LT128GSB 6 Configuration Register Table 12. Start Address Wait at the Boundary Number of WAIT states X-Latency = 7 X-Latency = 6 X-Latency = 5 X-Latency = 4 X-Latency = 3 X-Latency = 2 0 0 0 0 0 0 0 1 0 0 0 0 0 0 2 1 0 0 0 0 0 3 2 1 0 0 0 0 4 3 2 1 0 0 0 5 4 3 2 1 0 0 6 5 4 3 2 1 0 7 6 5 4 3 2 1 Figure 5. X-Latency and Data Output Configuration Example X-latency 1st cycle 2nd cycle 3rd cycle 4th cycle K E L A22-A0 tDELAY VALID ADDRESS tAVK_CPU tQVK_CPU tACC tK tKQV tQVK_CPU DQ15-DQ0 VALID ADDRESS VALID DATA VALID DATA AI10262 1. The settings shown are X-latency = 4, Data Output held for one clock cycle. 40/98 M58LT128GST, M58LT128GSB Figure 6. 6 Configuration Register Wait Configuration Example E K L G A22-A0 VALID ADDRESS DQ15-DQ0 VALID ADDRESS VALID DATA VALID DATA NOT VALID VALID DATA WAIT CR8 = '0' CR10 = '0' WAIT CR8 = '1' CR10 = '0' WAIT CR8 = '0' CR10 = '1' WAIT CR8 = '1' CR10 = '1' AI10263 41/98 7 Read modes 7 M58LT128GST, M58LT128GSB Read modes Read operations can be performed in two different ways depending on the settings in the Configuration Register. If the clock signal is ‘don’t care’ for the data output, the read operation is asynchronous; if the data output is synchronized with clock, the read operation is synchronous. The read mode and format of the data output are determined by the Configuration Register. (See Configuration Register section for details). All banks support both asynchronous and synchronous read operations. 7.1 Asynchronous Read modes In Asynchronous Read operations the clock signal is ‘don’t care’. The device outputs the data corresponding to the address latched, that is the memory array, Status Register, Common Flash Interface or Electronic Signature depending on the command issued. CR15 in the Configuration Register must be set to ‘1’ for asynchronous operations. In Asynchronous Read mode, the WAIT signal is always deasserted. The device features an Automatic Standby mode. During Asynchronous Read operations, after a bus inactivity of 150ns, the device automatically switches to the Automatic Standby mode. In this condition the power consumption is reduced to the standby value and the outputs are still driven. Asynchronous Read operations can be performed in two different ways, Asynchronous Random Read and Asynchronous Page Read. 7.1.1 Asynchronous Random Read Asynchronous Random Read operations are controlled by the Latch Enable, L, signal. A valid bus operation involves setting the desired address on the Address Inputs, setting Chip Enable and Latch Enable Low, VIL, and keeping Write Enable High, VIH. The address is latched on the rising edge of Latch Enable, L, before the value is output on the data bus. Once latched, the Address Inputs can change. Set Output Enable Low, VIL, to read the data on the Data Inputs/Outputs. See Table 22: Asynchronous Read AC Characteristics, and Figure 9: Asynchronous Random Access Read AC Waveforms for details. 7.1.2 Asynchronous Page Read Only Asynchronous Page Read takes full advantage of the internal page storage so different timings are applied. In Asynchronous Page Read mode, a Page of data is internally read and stored in a Page Buffer. The Page size is 8 Words and is addressed by address inputs A0, A1 and A2. The first read operation within the Page has the normal access time (tAVQV), subsequent reads within the same Page have much shorter access times (tAVQV1). If the Page changes then the normal longer timings apply again. See Table 22: Asynchronous Read AC Characteristics, Figure 10: Asynchronous Page Read AC Waveforms for details. 42/98 M58LT128GST, M58LT128GSB 7.2 7 Read modes Synchronous Burst Read modes In Synchronous Burst Read mode the data is output in bursts synchronized with the clock. It is possible to perform burst reads across bank boundaries. Synchronous Burst Read mode can only be used to read the memory array. For other read operations, such as Read Status Register, Read CFI and Read Electronic Signature, Single Synchronous Read or Asynchronous Random Access Read must be used. In Synchronous Burst Read mode the flow of the data output depends on parameters that are configured in the Configuration Register. A burst sequence starts at the first clock edge (rising or falling depending on Valid Clock Edge bit CR6 in the Configuration Register) after the falling edge of Latch Enable or Chip Enable, whichever occurs last. Addresses are internally incremented and data is output on each data cycle after a delay which depends on the X latency bits CR13-CR11 of the Configuration Register. The number of Words to be output during a Synchronous Burst Read operation can be configured as 4 Words, 8 Words, 16 Words or Continuous (Burst Length bits CR2-CR0). The data can be configured to remain valid for one or two clock cycles (Data Output Configuration bit CR9). The order of the data output can be modified through the Wrap Burst bit in the Configuration Register. The burst sequence is sequential and can be confined inside the 4, 8 or 16 Word boundary (Wrap) or overcome the boundary (No Wrap). The WAIT signal may be asserted to indicate to the system that an output delay will occur. This delay will depend on the starting address of the burst sequence and on the burst configuration. WAIT is asserted during the X latency, the WAIT state and at the end of a 4, 8 and 16 Word burst. It is only deasserted when output data are valid or when G is at VIH. In Continuous Burst Read mode a WAIT state will occur when crossing the first 16 Word boundary. If the starting address is aligned to the Burst Length (4, 8 or 16 Words) the wrapped configuration has no impact on the output sequence. The WAIT signal can be configured to be active Low or active High by setting CR10 in the Configuration Register. See Table 23: Synchronous Read AC Characteristics, and Figure 11: Synchronous Burst Read AC Waveforms, for details. 7.2.1 Synchronous Burst Read Suspend A Synchronous Burst Read operation can be suspended, freeing the data bus for other higher priority devices. It can be suspended during the initial access latency time (before data is output) in which case the initial latency time can be reduced to zero, or after the device has output data. When the Synchronous Burst Read operation is suspended, internal array sensing continues and any previously latched internal data is retained. A burst sequence can be suspended and resumed as often as required as long as the operating conditions of the device are met. A Synchronous Burst Read operation is suspended when Chip Enable, E, is Low and the current address has been latched (on a Latch Enable rising edge or on a valid clock edge). The Clock signal is then halted at VIH or at VIL, and Output Enable, G, goes High. When Output Enable, G, becomes Low again and the Clock signal restarts, the Synchronous Burst Read operation is resumed exactly where it stopped. 43/98 7 Read modes M58LT128GST, M58LT128GSB WAIT being gated by E, it will remain active and will not revert to high impedance when G goes High. So if two or more devices are connected to the system’s READY signal, to prevent bus contention the WAIT signal of the M58LT128GST and M58LT128GSB should not be directly connected to the system’s READY signal. WAIT will revert to high-impedance when Output Enable, G, or Chip Enable, E, goes High. See Table 23: Synchronous Read AC Characteristics, and Figure 13: Synchronous Burst Read Suspend AC Waveforms, for details. 7.2.2 Single Synchronous Read mode Single Synchronous Read operations are similar to Synchronous Burst Read operations except that the memory outputs the same data to the end of the operation. Synchronous Single Reads are used to read the Electronic Signature, Status Register, CFI, Configuration Register Status, or Protection Register. When the addressed bank is in Read CFI, Read Status Register or Read Electronic Signature mode, the WAIT signal is deasserted when Output Enable, G, is at VIH or for the one clock cycle during which output data is valid. Otherwise, it is asserted. See Table 23: Synchronous Read AC Characteristics, and Figure 11: Synchronous Burst Read AC Waveforms, for details. 44/98 M58LT128GST, M58LT128GSB 8 8 Dual Operations and Multiple Bank architecture Dual Operations and Multiple Bank architecture The Multiple Bank Architecture of the M58LT128GST and M58LT128GSB gives greater flexibility for software developers to split the code and data spaces within the memory array. The Dual Operations feature simplifies the software management of the device by allowing code to be executed from one bank while another bank is being programmed or erased. The Dual Operations feature means that while programming or erasing in one bank, read operations are possible in another bank with zero latency (only one bank at a time is allowed to be in program or erase mode). If a read operation is required in a bank, which is programming or erasing, the program or erase operation can be suspended. Also if the suspended operation was erase then a program command can be issued to another block, so the device can have one block in Erase Suspend mode, one programming and other banks in read mode. Bus Read operations are allowed in another bank between setup and confirm cycles of program or erase operations. By using a combination of these features, read operations are possible at any moment in the M58LT128GST and M58LT128GSB devices. Dual operations between the Parameter Bank and either of the CFI, or the Electronic Signature memory space are not allowed. Table 15 shows which dual operations are allowed or not between the CFI, the Electronic Signature locations and the memory array. Table 13 and Table 14 show the dual operations possible in other banks and in the same bank. Table 13. Dual Operations Allowed In Other Banks Commands allowed in another bank Read Array Read Status Register Read CFI Query Idle Yes Yes Yes Yes Yes Yes Yes Yes Programming Yes Yes Yes Yes – – Yes – Erasing Yes Yes Yes Yes – – Yes – Program Suspended Yes Yes Yes Yes – – – Yes Erase Suspended Yes Yes Yes Yes Yes – – Yes Status of bank Read Program/ Program/ Program, Block Electronic Erase Erase Buffer Program Erase Signature Suspend Resume 45/98 M58LT128GST, M58LT128GSB 8 Dual Operations and Multiple Bank architecture Table 14. Dual Operations Allowed In Same Bank Commands allowed in same bank Status of bank Read Array Read Read Read CFI Status Electronic Query Register Signature Program, Buffer Program Block Erase Program/ Program/ Erase Erase Suspend Resume Idle Yes Yes Yes Yes Yes Yes Yes Yes Programming –(1) Yes Yes Yes – – Yes – Erasing –(1) Yes Yes Yes – – Yes – Program Suspended Yes(2) Yes Yes Yes – – – Yes Erase Suspended Yes(2) Yes Yes Yes Yes(2) – – Yes 1. The Read Array command is accepted but the data output is not guaranteed until the Program or Erase has completed. 2. Not allowed in the Word that is being erased or programmed. Table 15. Dual Operation Limitations Commands allowed Current Status Read Parameter Blocks No No No Yes Located in Parameter Bank No No No Yes Not Located in Parameter Bank No Yes Yes In Different Bank Only Programming / Erasing Parameter Blocks Programming / Erasing Main Blocks 46/98 Read Main Blocks Read CFI / Electronic Signature Located in Not Located in Parameter Bank Parameter Bank M58LT128GST, M58LT128GSB 9 9 Program and Erase times and Endurance cycles Program and Erase times and Endurance cycles The Program and Erase times and the number of Program/ Erase cycles per block are shown in Table 16 Exact erase times may change depending on the memory array condition. The best case is when all the bits in the block are at ‘0’ (pre-programmed). The worst case is when all the bits in the block are at ‘1’ (not preprogrammed). Usually, the system overhead is negligible with respect to the erase time. In the M58LT128GST and M58LT128GSB the maximum number of Program/Erase cycles depends on the VPP voltage supply used. Table 16. Program/Erase Times and Endurance Cycles Parameter Condition(1)(2) Min Parameter Block (16 KWord) Erase Main Block (64 KWord) Preprogrammed Typ Typical after 100kW/E Cycles Max Unit 0.4 1 2.5 s 1 3 4 s Not Preprogrammed 1.2 4 s Word Program 30 60 µs Buffer Program 30 60 µs Word Program 90 180 µs Buffer Program 90 180 µs Buffer (32 Words) (Buffer Program) 440 880 µs Main Block (64 KWord) 880 Program 20 25 µs Erase 20 25 µs VPP = VDD SIngle Cell Program(3) Single Word ms Suspend Latency Main Blocks Program/Erase Cycles (per Block) Parameter Blocks 100,000 cycles 100,000 cycles 47/98 M58LT128GST, M58LT128GSB 9 Program and Erase times and Endurance cycles Parameter Condition(1)(2) Max Unit 0.4 2.5 s 1 4 s Word Program 30 60 µs Word Program 85 170 µs Buffer Enhanced Factory Program(4) 10 Buffer Program 340 Buffer Enhanced Factory Program 320 µs Buffer Program 640 ms Buffer Enhanced Factory Program 640 ms Buffer Program 10 s Buffer Enhanced Factory Program 10 s Parameter Block (16 KWord) Min Typ Typical after 100kW/E Cycles Erase Main Block (64 KWord) Single Cell VPP = VPPH Single Word Buffer (32 Words) Program(3) Main Block (64 KWords) Bank (16 Mbits) Main Blocks Program/Erase Cycles (per Block) Parameter Blocks µs 680 1000 cycles 2500 cycles 1. TA = –25 to 85°C; VDD = 1.7V to 2V; VDDQ = 2.7 to 3.6V. 2. Values are liable to change with the external system-level overhead (command sequence and Status Register polling execution). 3. Excludes the time needed to execute the command sequence. 4. This is an average value on the entire device. 48/98 µs M58LT128GST, M58LT128GSB 10 10 Maximum Rating Maximum Rating Stressing the device above the rating listed in the Absolute Maximum Ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. Table 17. Absolute Maximum Ratings Value Symbol Parameter Unit Min Max Ambient Operating Temperature –25 85 °C TBIAS Temperature Under Bias –25 85 °C TSTG Storage Temperature –65 125 °C VIO Input or Output Voltage –0.5 4.2 V VDD Supply Voltage –0.2 2.5 V Input/Output Supply Voltage –0.6 5 V Program Voltage –0.2 10 V Output Short Circuit Current 100 mA Time for VPP at VPPH 100 hours TA VDDQ VPP IO tVPPH 49/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters 11 DC and AC parameters This section summarizes the operating measurement conditions, and the DC and AC characteristics of the device. The parameters in the DC and AC characteristics Tables that follow, are derived from tests performed under the Measurement Conditions summarized in Table 18: Operating and AC Measurement Conditions. Designers should check that the operating conditions in their circuit match the operating conditions when relying on the quoted parameters. Table 18. Operating and AC Measurement Conditions M58LT128GST, M58LT128GSB Parameter Units 110 Min Max VDD Supply Voltage 1.7 2.0 V VDDQ Supply Voltage 2.7 3.6 V VPP Supply Voltage (Factory environment) 8.5 9.5 V VPP Supply Voltage (Application environment) –0.4 VDDQ+0.4 V Ambient Operating Temperature –25 85 °C Load Capacitance (CL) 30 Input Rise and Fall Times 5 Input Pulse Voltages Input and Output Timing Ref. Voltages Figure 7. ns 0 to VDDQ V VDDQ/2 V AC Measurement I/O Waveform VDDQ VDDQ/2 0V AI06161 50/98 pF M58LT128GST, M58LT128GSB Figure 8. 11 DC and AC parameters AC Measurement Load Circuit VDDQ VDDQ VDD 16.7kΩ DEVICE UNDER TEST CL 0.1µF 16.7kΩ 0.1µF CL includes JIG capacitance Table 19. Symbol CIN COUT AI06162 Capacitance Parameter Input Capacitance Output Capacitance Test Condition Min(1) Max(1) Unit VIN = 0V 6 8 pF VOUT = 0V 8 12 pF 1. Sampled only, not 100% tested. 51/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters Table 20. DC Characteristics - Currents Symbol Parameter Test Condition Typ Max Unit 0V ≤VIN ≤VDDQ ±1 µA ±1 µA ILI Input Leakage Current ILO Output Leakage Current 0V ≤VOUT ≤VDDQ Supply Current Asynchronous Read (f=5MHz) E = VIL, G = VIH 13 15 mA 4 Word 16 18 mA 8 Word 18 20 mA 16 Word 23 25 mA Continuous 25 27 mA RP = VSS ± 0.2V 25 70 µA IDD1 Supply Current Synchronous Read (f=52MHz) IDD2 Supply Current (Reset) IDD3 Supply Current (Standby) E = VDD ± 0.2V 25 70 µA IDD4 Supply Current (Automatic Standby) E = VIL, G = VIH 25 70 µA VPP = VPPH 8 15 mA VPP = VDD 10 20 mA VPP = VPPH 8 15 mA VPP = VDD 10 20 mA Program/Erase in one Bank, Asynchronous Read in another Bank 23 35 mA Program/Erase in one Bank, Synchronous Read (Continuous f=52MHz) in another Bank 35 47 mA E = VDD ± 0.2V 25 70 µA VPP = VPPH 2 5 mA VPP = VDD 0.2 5 µA VPP = VPPH 2 5 mA VPP = VDD 0.2 5 µA VPP Supply Current (Read) VPP ≤VDD 0.2 5 µA VPP Supply Current (Standby) VPP ≤VDD 0.2 5 µA Supply Current (Program) IDD5 (1) Supply Current (Erase) Supply Current IDD6 (1)(2) (Dual Operations) IDD7(1) Supply Current Program/ Erase Suspended (Standby) VPP Supply Current (Program) IPP1(1) VPP Supply Current (Erase) IPP2 IPP3(1) 1. Sampled only, not 100% tested. 2. VDD Dual Operation current is the sum of read and program or erase currents. 52/98 M58LT128GST, M58LT128GSB Table 21. Symbol 11 DC and AC parameters DC Characteristics - Voltages Parameter Test Condition Min Typ Max Unit VIL Input Low Voltage 0 0.4 V VIH Input High Voltage VDDQ –0.4 VDDQ + 0.4 V VOL Output Low Voltage IOL = 100µA 0.1 V VOH Output High Voltage IOH = –100µA VDDQ –0.1 VPP1 VPP Program Voltage-Logic Program, Erase 1.1 1.8 3.3 V VPPH VPP Program Voltage Factory Program, Erase 8.5 9.0 9.5 V VPPLK Program or Erase Lockout 0.4 V VLKO VDD Lock Voltage VRPH RP pin Extended High Voltage V 1 V 3.3 V 53/98 54/98 Hi-Z Hi-Z tGLTV tELQX tELTV tGLQV tLHAX tGLQX tELQV tLLQV tAVQV Note. Write Enable, W, is High, WAIT is active Low. WAIT DQ0-DQ15 G E tELLH tLLLH tAVLH VALID tGHTZ VALID tEHQZ tEHQX tEHTZ tGHQZ tGHQX tAXQX VALID AI08311 Figure 9. L A0-A22 tAVAV 11 DC and AC parameters M58LT128GST, M58LT128GSB Asynchronous Random Access Read AC Waveforms M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 10. Asynchronous Page Read AC Waveforms A2-A22 VALID ADDRESS tAVAV A0-A2 VALID ADDRESS VALID ADD. VALID ADD. VALID ADD. tLHAX tAVLH L tLLLH tLLQV tELLH E tELQV tELQX G tGLTV WAIT (1) Hi-Z tELTV tGLQV tGLQX tAVQV1 VALID DATA DQ0-DQ15 Outputs Valid Address Latch Note 1. WAIT is active Low. Enabled VALID DATA VALID DATA Valid Data VALID DATA Standby AI08334b 55/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters Table 22. Asynchronous Read AC Characteristics Symbol Alt M58LT128GST, M58LT128GSB Parameter Unit 110 tAVAV tRC Address Valid to Next Address Valid Min 110 ns tAVQV tACC Address Valid to Output Valid (Random) Max 110 ns tAVQV1 tPAGE Address Valid to Output Valid (Page) Max 25 ns tAXQX(1) tOH Address Transition to Output Transition Min 0 ns Chip Enable Low to Wait Valid Max 16 ns Read Timings tELTV tELQV(2) tCE Chip Enable Low to Output Valid Max 110 ns tELQX(1) tLZ Chip Enable Low to Output Transition Max 0 ns Chip Enable High to Wait Hi-Z Max 17 ns tEHTZ tEHQX(1) tOH Chip Enable High to Output Transition Min 0 ns tEHQZ(1) tHZ Chip Enable High to Output Hi-Z Max 17 ns tGLQV (2) tOE Output Enable Low to Output Valid Max 30 ns tGLQX(1) tOLZ Output Enable Low to Output Transition Min 0 ns Output Enable Low to WAIT Valid Max 17 ns Latch Timings tGLTV tGHQX (1) tOH Output Enable High to Output Transition Min 0 ns tGHQZ (1) tDF Output Enable High to Output Hi-Z Max 17 ns tGHTZ tDF Output Enable High to WAIT Hi-Z Max 17 ns tAVLH tAVADVH Address Valid to Latch Enable High Min 11 ns tELLH tELADVH Chip Enable Low to Latch Enable High Min 10 ns tLHAX tADVHAX Latch Enable High to Address Transition Min 9 ns Min 11 ns Max 110 ns tLLLH tLLQV tADVLADVH Latch Enable Pulse Width tADVLQV Latch Enable Low to Output Valid (Random) 1. Sampled only, not 100% tested. 2. G may be delayed by up to tELQV - tGLQV after the falling edge of E without increasing tELQV. 56/98 Hi-Z tELKH Hi-Z tLLLH Address Latch tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS X Latency tGLTV tGLQX Note 2 Note 1 VALID Valid Data Flow tKHTV tKHQV tKHQV VALID Note 2 tKHTX tKHQX tKHQX VALID Boundary Crossing Note 2 tKHTV tKHTX tKHQV tKHQX NOT VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Burst Configuration Register. 2. The WAIT signal can be configured to be active during wait state or one cycle before. WAIT signal is active Low. 3. Address latched and data output on the rising clock edge. 4. Either the rising or the falling edge of the clock signal, K, can be configured as the active edge. Here, the active edge of K is the rising one. WAIT G E K(4) L A0-A22 DQ0-DQ15 Data Valid tGHQZ tGHQX Standby tEHTZ AI08309 tEHQZ tEHQX tEHEL VALID M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 11. Synchronous Burst Read AC Waveforms 57/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 12. Single Synchronous Read AC Waveforms A0-A22 VALID ADDRESS tAVKH L tLLKH K(2) tELKH tKHQV tELQV E tGLQV tGLQX G tELQX DQ0-DQ15 tGHTZ Hi-Z VALID tKHTV tGLTV WAIT(1,2) Hi-Z Note 1. The WAIT signal is configured to be active during wait state. WAIT signal is active Low. 2. Address latched and data output on the rising clock edge. Either the rising or the falling edge of the clock signal, K, can be configured as the active edge. Here, the active edge is the rising one. AI08312 58/98 tELKH Hi-Z Hi-Z tLLLH tELTV tKHAX tAVKH tLLKH tAVLH VALID ADDRESS tGLTV tGLQV tGLQX Note 1 tKHQV VALID VALID tGHTZ tGHQZ Note 3 tGLTV tGLQV tGHQZ tGHQX tEHEL tEHQZ AI08308 tEHTZ NOT VALID tEHQX NOT VALID Note 1. The number of clock cycles to be inserted depends on the X latency set in the Configuration Register. 2. The WAIT signal is configured to be active during wait state. WAIT signal is active Low. 3. The CLOCK signal can be held high or low 4. Address latched and data output on the rising clock edge. Either the rising or the falling edge of the clock signal, K, can be configured as the active edge. Here, the active edge is the rising one. WAIT(2) G E K(4) L A0-A22 DQ0-DQ15 M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 13. Synchronous Burst Read Suspend AC Waveforms 59/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 14. Clock input AC Waveform tKHKL tKHKH tr tf tKLKH AI06981 Table 23. Synchronous Read AC Characteristics Symbol Alt M58LT128GST, M58LT128GSB Parameter(1) Unit Synchronous Read Timings 110 tAVKH tAVCLKH Address Valid to Clock High Min 11 ns tELKH tELCLKH Chip Enable Low to Clock High Min 11 ns tELTV Chip Enable Low to Wait Valid Max 16 ns tEHEL Chip Enable Pulse Width (subsequent synchronous reads) Min 17 ns tEHTZ Chip Enable High to Wait Hi-Z Max 17 ns tGLTV Output Enable Low to Wait Valid Max 17 ns tCLKHAX Clock High to Address Transition Min 10 ns tCLKHQV Clock High to Output Valid Clock High to WAIT Valid Max 17 ns tCLKHQX Clock High to Output Transition Clock High to WAIT Transition Min 3 ns tLLKH tADVLCLKH Latch Enable Low to Clock High Min 11 ns tGHTZ tDF Output Enable High to WAIT Hi-Z Max 17 ns tKHKH tCLK Clock Period (f=52MHz) Min 19 ns tKLKH Clock High to Clock Low Clock Low to Clock High Min 6 ns tf, tr Clock Fall or Rise Time Max 2 ns tKHAX tKHQV tKHTV tKHQX Clock Specifications tKHTX tKHKL 1. Sampled only, not 100% tested. For other timings please refer to Table 22: Asynchronous Read AC Characteristics. 60/98 K VPP DQ0-DQ15 W G E L A0-A22 tWHDX CONFIRM COMMAND OR DATA INPUT tWHVPL tELKV tWHEL tWHGL tWHAV tWHAX CMD or DATA VALID ADDRESS tAVWH tVPHWH tWHWL tWHEH tWHLL tWLWH tLHAX COMMAND tLLLH SET-UP COMMAND tDVWH tGHWL tELWL tELLH tAVLH BANK ADDRESS tAVAV tQVVPL STATUS REGISTER STATUS REGISTER READ 1st POLLING tELQV VALID ADDRESS PROGRAM OR ERASE AI08016c M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 15. Write AC Waveforms, Write Enable Controlled 61/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters Table 24. Write AC Characteristics, Write Enable Controlled Symbol M58LT128GST, M58LT128GSB Parameter(1) Alt Unit 110 tAVAV tWC Address Valid to Next Address Valid Min 110 ns tAVLH Address Valid to Latch Enable High Min 11 ns tAVWH(2) Address Valid to Write Enable High Min 50 ns Data Valid to Write Enable High Min 50 ns Chip Enable Low to Latch Enable High Min 11 ns Chip Enable Low to Write Enable Low Min 0 ns tELQV Chip Enable Low to Output Valid Min 110 ns tELKV Chip Enable Low to Clock Valid Min 9 ns tGHWL Output Enable High to Write Enable Low Min 17 ns tLHAX Latch Enable High to Address Transition Min 9 ns tLLLH Latch Enable Pulse Width Min 11 ns tWHAV(2) Write Enable High to Address Valid Min 0 ns tWHAX(2) Write Enable High to Address Transition Min 0 ns tDVWH tDS tELLH Protection Timings Write Enable Controlled Timings tELWL tCS tWHDX tDH Write Enable High to Input Transition Min 0 ns tWHEH tCH Write Enable High to Chip Enable High Min 0 ns tWHEL(3) Write Enable High to Chip Enable Low Min 25 ns tWHLL Write Enable High to Latch Enable Low Min 0 ns tWHWL tWPH Write Enable High to Write Enable Low Min 25 ns tWLWH tWP Write Enable Low to Write Enable High Min 50 ns Output (Status Register) Valid to VPP Low Min 0 ns VPP High to Write Enable High Min 200 ns Write Enable High to VPP Low Min 200 ns tQVVPL tVPHWH tWHVPL tVPS 1. Sampled only, not 100% tested. 2. These timings are meaningful only if Latch Enable, L, is always kept Low, VIL. 3. tWHEL has the values shown when reading in the targeted bank. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing a command. If it is a Read Array operation in a different bank tWHEL is 0ns. 62/98 K VPP DQ0-DQ15 E G W L A0-A22 tGHEL tELEH tLHAX COMMAND SET-UP COMMAND tDVEH tLLLH tELLH tWLEL tAVLH BANK ADDRESS tEHDX tEHEL tEHWH CMD or DATA tEHAX CONFIRM COMMAND OR DATA INPUT tVPHEH tAVEH VALID ADDRESS tAVAV tEHVPL tELKV tWHEL tEHGL AI08017c tQVVPL STATUS REGISTER STATUS REGISTER READ 1st POLLING tELQV VALID ADDRESS PROGRAM OR ERASE M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 16. Write AC Waveforms, Chip Enable Controlled 63/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters Table 25. Write AC Characteristics, Chip Enable Controlled Symbol M58LT128GST, M58LT128GSB Parameter(1) Alt Unit 110 Chip Enable Controlled Timings tAVAV tWC Address Valid to Next Address Valid Min 110 ns tAVEH Address Valid to Chip Enable High Min 50 ns tAVLH Address Valid to Latch Enable High Min 11 ns tDVEH tDS Data Valid to Chip Enable High Min 50 ns tEHAX tAH Chip Enable High to Address Transition Min 0 ns tEHDX tDH Chip Enable High to Input Transition Min 0 ns tEHEL tWPH Chip Enable High to Chip Enable Low Min 25 ns Chip Enable High to Output Enable Low Min 0 ns Chip Enable High to Write Enable High Min 0 ns Chip Enable Low to Clock Valid Min 7 ns Chip Enable Low to Chip Enable High Min 50 ns tELLH Chip Enable Low to Latch Enable High Min 11 ns tELQV Chip Enable Low to Output Valid Min 110 ns tGHEL Output Enable High to Chip Enable Low Min 17 ns tLHAX Latch Enable High to Address Transition Min 9 ns tLLLH Latch Enable Pulse Width Min 11 ns Write Enable High to Chip Enable Low Min 25 ns Write Enable Low to Chip Enable Low Min 0 ns tEHVPL Chip Enable High to VPP Low Min 200 ns tQVVPL Output (Status Register) Valid to VPP Low Min 0 ns VPP High to Chip Enable High Min 200 ns tEHGL tEHWH tCH tELKV tELEH tWP tWHEL(2) Protection Timings tWLEL tVPHEH tCS tVPS 1. Sampled only, not 100% tested. 2. tWHEL has the values shown when reading in the targeted bank. System designers should take this into account and may insert a software No-Op instruction to delay the first read in the same bank after issuing a command. If it is a Read Array operation in a different bank tWHEL is 0ns. 64/98 M58LT128GST, M58LT128GSB 11 DC and AC parameters Figure 17. Reset and Power-up AC Waveforms tPHWL tPHEL tPHGL tPHLL W, E, G, L tPLWL tPLEL tPLGL tPLLL RP tVDHPH tPLPH VDD, VDDQ Power-Up Reset AI06976 Table 26. Reset and Power-up AC Characteristics Symbol Parameter Test Condition 110 Unit During Program Min 25 µs During Erase Min 25 µs Other Conditions Min 110 ns Reset High to Write Enable Low Chip Enable Low Output Enable Low Latch Enable Low Min 30 ns tPLPH(1)(2) RP Pulse Width Min 50 ns tVDHPH(3) Supply Voltages High to Reset High Min 100 µs tPLWL tPLEL tPLGL tPLLL tPHWL tPHEL tPHGL tPHLL Reset Low to Write Enable Low, Chip Enable Low, Output Enable Low, Latch Enable Low 1. The device Reset is possible but not guaranteed if tPLPH < 50ns. 2. Sampled only, not 100% tested. 3. It is important to assert RP in order to allow proper CPU initialization during Power-Up or Reset. 65/98 M58LT128GST, M58LT128GSB 12 Package mechanical 12 Package mechanical Figure 18. TBGA64 10x13mm - 8x8 active ball array, 1mm pitch, Bottom View Package Outline D D1 FD FE E SD SE E1 ddd BALL "A1" A e b A2 A1 BGA-Z23 1. Drawing is not to scale. Table 27. TBGA64 10x13mm - 8x8 active ball array, 1mm pitch, Package Mechanical Data millimeters inches Symbol Typ Min A Typ Min 1.200 A1 0.300 A2 0.800 b 0.200 0.350 Max 0.0472 0.0118 0.0079 0.0138 0.0138 0.0197 0.0315 0.350 0.500 D 10.000 9.900 10.100 0.3937 0.3898 0.3976 D1 7.000 – – 0.2756 – – ddd 66/98 Max 0.100 0.0039 e 1.000 – – 0.0394 – – E 13.000 12.900 13.100 0.5118 0.5079 0.5157 E1 7.000 – – 0.2756 – – FD 1.500 – – 0.0591 – – FE 3.000 – – 0.1181 – – SD 0.500 – – 0.0197 – – SE 0.500 – – 0.0197 – – M58LT128GST, M58LT128GSB 13 13 Part Numbering Part Numbering Table 28. Ordering Information Scheme Example: M58LT128GS T 1 ZA 5 E Device Type M58 Architecture L = Multilevel, Multiple Bank, Burst Mode Operating Voltage T = VDD = 1.7V to 2.0V, VDDQ =2.7V to 3.6V Density 128 = 128 Mbit (x16) Technology G = 0.13µm Security S = Security Parameter Location T = Top Boot B = Bottom Boot Speed 1 = 110ns Package ZA = TBGA64, 10 x 13mm, 1mm pitch Temperature Range 5 = –25 to 85°C Packing Option Blank = Standard Packing E = ECOPACK Package, Standard Packing F =ECOPACK Package, 24mm Tape & Reel Packing 67/98 M58LT128GST, M58LT128GSB 13 Part Numbering Table 29. Daisy Chain Ordering Scheme Example: M58LT128GS -ZA E Device Type M58LT128GS Daisy Chain ZA = TBGA64, 10 x 13mm, 1mm pitch Option Blank = Standard Packing E = ECOPACK Package, Standard Packing Devices are shipped from the factory with the memory content bits erased to ’1’. For a list of available options (Speed, Package, etc.) or for further information on any aspect of this device, please contact the ST Sales Office nearest to you. 68/98 M58LT128GST, M58LT128GSB 13 Part Numbering Appendix A Block address tables The following set of equations can be used to calculate a complete set of block addresses for the M58LT128GST and M58LT128GSB using the information contained in Table 30 to Table 35. To calculate the Block Base Address from the Block Number: First it is necessary to calculate the Bank Number and the Block Number Offset. This can be achieved using the following formulas: Bank_Number = (Block_Number − 3) / 16 Block_Number_Offset = Block_Number − 3 − (Bank_Number x 16) If Bank_Number = 0, the Block Base Address can be directly read from Table 30 and Table 33 (Parameter Bank Block Addresses) in the Address Range column, in the row that corresponds to the given block number. Otherwise: Block_Base_Address = Bank_Base_Address + Block_Base_Address_Offset To calculate the Bank Number and the Block Number from the Block Base Address: If the address is in the range of the Parameter Bank, the Bank Number is 0 and the Block Number can be directly read from Table 30 for the M58LT128GST and Table 33 for the M58LT128GSB (Parameter Bank Block Addresses), in the Block Number column, in the row that corresponds to the address given. Otherwise, the Block Number can be calculated using the formulas below: For the top configuration (M58LT128GST): Block_Number = ((NOT address) / 216) + 3 For the bottom configuration (M58LT128GSB): Block_Number = (address / 216) + 3 For both configurations the Bank Number and the Block Number Offset can be calculated using the following formulas: Bank_Number = (Block_Number − 3) / 16 Block_Number_Offset = Block_Number − 3 − (Bank_Number x 16) 69/98 M58LT128GST, M58LT128GSB 13 Part Numbering Table 30. M58LT128GST - Parameter Bank Block Addresses Block Number Size (KWords) Address Range 0 16 7FC000-7FFFFF 1 16 7F8000-7FBFFF 2 16 7F4000-7F7FFF 3 16 7F0000-7F3FFF 4 64 7E0000-7EFFFF 5 64 7D0000-7DFFFF 6 64 7C0000-7CFFFF 7 64 7B0000-7BFFFF 8 64 7A0000-7AFFFF 9 64 790000-79FFFF 10 64 780000-78FFFF Table 31. M58LT128GST - Main Bank Base Addresses Bank Number Block Numbers Bank Base Address 1 11-18 700000 2 19-26 680000 3 27-34 600000 4 35-42 580000 5 43-50 500000 6 51-58 480000 7 59-66 400000 8 67-74 380000 9 75-82 300000 10 83-90 280000 11 91-98 200000 12 99-106 180000 13 107-114 100000 14 115-122 080000 15 123-130 000000 1. There are two Bank Regions: Bank Region 1 contains all the banks that are made up of main blocks only; Bank Region 2 contains the banks that are made up of the parameter and main blocks (Parameter Bank). 70/98 M58LT128GST, M58LT128GSB Table 32. 13 Part Numbering M58LT128GST - Block Addresses in Main Banks Block Number Offset Block Base Address Offset 0 070000 1 060000 2 050000 3 040000 4 030000 5 020000 6 010000 7 000000 Table 33. M58LT128GSB - Parameter Bank Block Addresses Block Number Size (KWords) Address Range 10 64 070000-07FFFF 9 64 060000-06FFFF 8 64 050000-05FFFF 7 64 040000-04FFFF 6 64 030000-03FFFF 5 64 020000-02FFFF 4 64 010000-01FFFF 3 16 00C000-00FFFF 2 16 008000-00BFFF 1 16 004000-007FFF 0 16 000000-003FFF 71/98 M58LT128GST, M58LT128GSB 13 Part Numbering Table 34. M58LT128GSB- Main Bank Base Addresses Bank Number Block Numbers Bank Base Address 15 123-130 780000 14 115-122 700000 13 107-114 680000 12 99-106 600000 11 91-98 580000 10 83-90 500000 9 75-82 480000 8 67-74 400000 7 59-66 380000 6 51-58 300000 5 43-50 280000 4 35-42 200000 3 27-34 180000 2 19-26 100000 1 11-18 080000 1. There are two Bank Regions: Bank Region 2 contains all the banks that are made up of main blocks only; Bank Region 1 contains the banks that are made up of the parameter and main blocks (Parameter Bank). Table 35. 72/98 M58LT128GSB - Block Addresses in Main Banks Block Number Offset Block Base Address Offset 7 070000 6 060000 5 050000 4 040000 3 030000 2 020000 1 010000 0 000000 M58LT128GST, M58LT128GSB 13 Part Numbering Appendix B Common Flash Interface The Common Flash Interface is a JEDEC approved, standardized data structure that can be read from the Flash memory device. It allows a system software to query the device to determine various electrical and timing parameters, density information and functions supported by the memory. The system can interface easily with the device, enabling the software to upgrade itself when necessary. When the Read CFI Query Command is issued the device enters CFI Query mode and the data structure is read from the memory. Table 36, Table 37, Table 38, Table 39, Table 40, Table 42, Table 43, Table 44 and Table 45 show the addresses used to retrieve the data. The Query data is always presented on the lowest order data outputs (DQ0-DQ7), the other outputs (DQ8-DQ15) are set to 0. The CFI data structure also contains a security area where a 64 bit unique security number is written (see Figure 4: Protection Register Map).This area can be accessed only in Read mode by the final user. It is impossible to change the security number after it has been written by ST. Issue a Read Array command to return to Read mode. Table 36. Query Structure Overview Offset Sub-section Name Description 000h Reserved Reserved for algorithm-specific information 010h CFI Query Identification String Command set ID and algorithm data offset 01Bh System Interface Information Device timing & voltage information 027h Device Geometry Definition Flash device layout P Primary Algorithm-specific Extended Query table Additional information specific to the Primary Algorithm (optional) A Alternate Algorithm-specific Extended Query table Additional information specific to the Alternate Algorithm (optional) Security Code Area Lock Protection Register Unique device Number and User Programmable OTP 080h 1. The Flash memory display the CFI data structure when CFI Query command is issued. In this table are listed the main subsections detailed in Table 37, Table 38, Table 39 and Table 40. Query data is always presented on the lowest order data outputs. 73/98 M58LT128GST, M58LT128GSB 13 Part Numbering Table 37. CFI Query Identification String Offset Sub-section Name 000h 0020h Manufacturer Code 001h 88C6h 88C7h Device Code 002h reserved 003h DRC 004h-00Fh reserved 010h 0051h 011h 0052h 012h 0059h 013h 0001h 014h 0000h 015h offset = P = 000Ah 016h 0001h 017h 0000h 018h 0000h 019h value = A = 0000h 01Ah 0000h Table 38. Description Value ST M58LT128GST M58LT128GSB Top Bottom Reserved Die Revision Code Reserved "Q" Query Unique ASCII String "QRY" "R" "Y" Primary Algorithm Command Set and Control Interface ID code 16 bit ID code defining a specific algorithm Address for Primary Algorithm extended Query table (see Table 40) p = 10Ah Alternate Vendor Command Set and Control Interface ID Code second vendor - specified algorithm supported NA Address for Alternate Algorithm extended Query table NA CFI Query System Interface Information Offset Data 01Bh 0017h 01Ch 0020h 01Dh 0085h Description Value VDD Logic Supply Minimum Program/Erase or Write voltage bit 7 to 4 BCD value in volts bit 3 to 0 BCD value in 100 millivolts 1.7V VDD Logic Supply Maximum Program/Erase or Write voltage bit 7 to 4 BCD value in volts bit 3 to 0 BCD value in 100 millivolts 2V VPP [Programming] Supply Minimum Program/Erase voltage bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 millivolts 8.5V VPP [Programming] Supply Maximum Program/Erase voltage 9.5V 01Eh 0095h bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 millivolts 01Fh 0008h Typical time-out per single byte/word program = 2n µs 256µs 020h 0009h Typical time-out for Buffer Program = 2n µs 512µs 021h 000Ah Typical time-out per individual block erase = 2n ms 1s 022h 0000h Typical time-out for full chip erase = 2n ms NA 74/98 M58LT128GST, M58LT128GSB 13 Part Numbering Offset Data 023h 0001h Maximum time-out for word program = 2n times typical 512µs 024h 0001h Maximum time-out for Buffer Program = 2n times typical 1024µs 025h 0002h Maximum time-out per individual block erase = 2n times typical 4s 026h 0000h Maximum time-out for chip erase = 2n times typical NA TOP DEVICES Table 39. Value Device Geometry Definition Offset Data 027h 0018h Device Size = 2n in number of bytes 028h 029h 0001h 0000h Flash Device Interface Code description 02Ah 02Bh 0006h 0000h Maximum number of bytes in multi-byte program or page = 2n 64 Bytes 02Ch 0002h Number of identical sized erase block regions within the device bit 7 to 0 = x = number of Erase Block Regions 2 02Dh 02Eh 007Eh 0000h Erase Block Region 1 Information Number of identical-size erase blocks = 007Eh+1 02Fh 030h 0000h 0002h Erase Block Region 1 Information Block size in Region 1 = 0200h * 256 Byte 031h 032h 0003h 0000h Erase Block Region 2 Information Number of identical-size erase blocks = 0003h+1 033h 034h 0080h 0000h Erase Block Region 2 Information Block size in Region 2 = 0080h * 256 Byte 035h 038h BOTTOM DEVICES Description Description Reserved Reserved for future erase block region information 02Dh 02Eh 0003h 0000h Erase Block Region 1 Information Number of identical-size erase block = 0003h+1 02Fh 030h 0080h 0000h Erase Block Region 1 Information Block size in Region 1 = 0080h * 256 bytes 031h 032h 007Eh 0000h Erase Block Region 2 Information Number of identical-size erase block = 007Eh+1 033h 034h 0000h 0002h Erase Block Region 2 Information Block size in Region 2 = 0200h * 256 bytes 035h 038h Reserved Reserved for future erase block region information Value 16 MBytes x16 Async. 127 128 KByte 4 32 KByte NA 4 32 KBytes 127 128 KBytes NA 75/98 M58LT128GST, M58LT128GSB 13 Part Numbering Table 40. Primary Algorithm-Specific Extended Query Table Offset Data (P)h = 10Ah 0050h 0052h Description Value "P" Primary Algorithm extended Query table unique ASCII string “PRI” 0049h "R" "I" (P+3)h =10Dh 0031h Major version number, ASCII "1" (P+4)h = 10Eh 0033h Minor version number, ASCII "3" (P+5)h = 10Fh 00E6h Extended Query table contents for Primary Algorithm. Address (P+5)h contains less significant byte. 0003h (P+7)h = 111h (P+8)h = 112h 0000h 0000h bit 0 Chip Erase supported(1 = Yes, 0 = No) bit 1 Erase Suspend supported(1 = Yes, 0 = No) bit 2 Program Suspend supported(1 = Yes, 0 = No) bit 3 Reserved bit 5 Instant individual block locking supported(1 = Yes, 0 = No) bit 6 Protection bits supported(1 = Yes, 0 = No) bit 7 Page mode read supported(1 = Yes, 0 = No) bit 8 Synchronous read supported(1 = Yes, 0 = No) bit 9 Simultaneous operation supported(1 = Yes, 0 = No) bit 10 to 31 Reserved; undefined bits are ‘0’. If bit 31 is ’1’ then another 31 bit field of optional features follows at the end of the bit-30 field. No Yes Yes No No Yes Yes Yes Yes Yes Supported Functions after Suspend Read Array, Read Status Register and CFI Query (P+9)h = 113h 0001h Yes bit 0 Program supported after Erase Suspend (1 = Yes, 0 = No) bit 7 to 1 Reserved; undefined bits are ‘0’ (P+A)h = 114h 0003h (P+B)h = 115h 0000h Reserved VDD Logic Supply Optimum Program/Erase voltage (highest performance) (P+C)h = 116h 0018h bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 mV 1.8V VPP Supply Optimum Program/Erase voltage (P+D)h = 117h 76/98 0090h bit 7 to 4 HEX value in volts bit 3 to 0 BCD value in 100 mV 9V M58LT128GST, M58LT128GSB Table 41. 13 Part Numbering Protection Register Information Offset Data (P+E)h = 118h 0002h (P+F)h = 119h 0080h (P+10)h = 11Ah 0000h (P+11)h = 11Bh 0003h (P+12)h = 11Ch 0003h (P+13)h = 11Dh 0089h (P+14)h = 11Eh 0000h (P+15)h = 11Fh 0000h (P+16)h = 120h 0000h (P+17)h = 121h 0000h Description Number of protection register fields in JEDEC ID space. 0000h indicates that 256 fields are available. Protection Field 1: Protection Description Bits 0-7 Lower byte of protection register address Bits 8-15 Upper byte of protection register address Bits 16-23 2n bytes in factory pre-programmed region Bits 24-31 2n bytes in user programmable region Value 2 80h 00h 8 Bytes 8 Bytes 89h 00h Protection Register 2: Protection Description Bits 0-31 protection register address Bits 32-39 n number of factory programmed regions (lower byte) Bits 40-47 n number of factory programmed regions (upper byte) 00h 00h 0 Bits 48-55 2n bytes in factory programmable region Bits 56-63 n number of user programmable regions (lower byte) Bits 64-71 n number of user programmable regions (upper byte) 0 Bits 72-79 2n bytes in user programmable region 16 (P+18)h = 122h 0000h (P+19)h = 123h 0000h (P+1A)h = 124h 0010h (P+1B)h = 125h 0000h 0 (P+1C)h = 126h 0004h 16 Table 42. 0 Burst Read Information Offset Data Description Value Page-mode read capability (P+1D)h = 127h 0004h (P+1E)h = 128h 0004h bits 0-7 n’ such that 2n HEX value represents the number of read-page 16 Bytes bytes. See offset 0028h for device word width to determine page-mode data output width. Number of synchronous mode read configuration fields that follow. 4 Synchronous mode read capability configuration 1 bit 3-7 Reserved bit 0-2 n’ such that 2n+1 HEX value represents the maximum number of continuous synchronous reads when the device is configured for its maximum word width. A value of 07h indicates that the device is capable of continuous linear bursts that will output data until the internal burst counter reaches the end of the device’s burstable address space. This field’s 3-bit value can be written directly to the read configuration register bit 0-2 if the device is configured for its maximum word width. See offset 0028h for word width to determine the burst data output width. (P+1F)h = 129h 0001h (P+20)h = 12Ah 0002h Synchronous mode read capability configuration 2 8 (P-21)h = 12Bh 0003h Synchronous mode read capability configuration 3 16 (P+22)h = 12Ch 0007h Synchronous mode read capability configuration 4 Cont. 4 77/98 M58LT128GST, M58LT128GSB 13 Part Numbering Table 43. Bank and Erase Block Region Information Flash memory (top) Flash memory (bottom) Description Offset Data Offset Data (P+23)h = 12Dh 02h (P+23)h = 12Dh 02h Number of Bank Regions within the device 1. The variable P is a pointer which is defined at CFI offset 015h. 2. Bank Regions. There are two Bank Regions, see Table 30 to Table 35. 78/98 M58LT128GST, M58LT128GSB Table 44. 13 Part Numbering Bank and Erase Block Region 1 Information Flash memory (top) Flash memory (bottom) Offset Data Offset Data (P+24)h = 12Eh 0Fh (P+24)h = 12Eh 01h (P+25)h = 12Fh 00h (P+25)h = 12Fh 00h Description Number of identical banks within Bank Region 1 (P+26)h = 130h (P+27)h = 131h (P+28)h = 132h (P+29)h = 133h 11h 00h 00h 01h (P+26)h = 130h (P+27)h = 131h (P+28)h = 132h (P+29)h = 133h 11h Number of program or erase operations allowed in Bank Region 1: Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in same region is programming Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is erasing Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 02h Types of erase block regions in Bank Region 1 n = number of erase block regions with contiguous same-size erase blocks. Symmetrically blocked banks have one blocking region(2). (P+2A)h = 134h 07h (P+2A)h = 134h 03h (P+2B)h = 135h 00h (P+2B)h = 135h 00h (P+2C)h = 136h 00h (P+2C)h = 136h 80h (P+2D)h = 137h 02h (P+2D)h = 137h 00h (P+2E)h = 138h 64h (P+2E)h = 138h 64h (P+2F)h = 139h 00h (P+2F)h = 139h 00h (P+30)h = 13Ah (P+31)h = 13Bh 02h 03h (P+30)h = 13Ah (P+31)h = 13Bh Bank Region 1 Erase Block Type 1 Information Bits 0-15: n+1 = number of identical-sized erase blocks Bits 16-31: n×256 = number of bytes in erase block region Bank Region 1 (Erase Block Type 1) Minimum block erase cycles × 1000 02h Bank Region 1 (Erase Block Type 1): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 03h Bank Region 1 (Erase Block Type 1): Page mode and Synchronous mode capabilities Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved 79/98 M58LT128GST, M58LT128GSB 13 Part Numbering Flash memory (top) Offset Data Flash memory (bottom) Description Offset Data (P+32)h = 13Ch 06h (P+33)h = 13Dh 00h (P+34)h = 13Eh 00h (P+35)h = 13Fh 02h Bits 16-31: n×256 = number of bytes in erase block region (P+36)h = 140h 64h (P+37)h = 141h 00h Bank Region 1 (Erase Block Type 2) Minimum block erase cycles × 1000 (P+38)h = 142h (P+39)h = 143h Bank Region 1 Erase Block Type 2 Information Bits 0-15: n+1 = number of identical-sized erase blocks 02h Bank Regions 1 (Erase Block Type 2): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 03h Bank Region 1 (Erase Block Type 2): Page mode and Synchronous mode capabilities Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved 1. The variable P is a pointer which is defined at CFI offset 015h. 2. Bank Regions. There are two Bank Regions, see Table 30 to Table 35. 80/98 M58LT128GST, M58LT128GSB Table 45. 13 Part Numbering Bank and Erase Block Region 2 Information Flash memory (top) Flash memory (bottom) Description Offset Data Offset Data (P+32)h = 13Ch 01h (P+3A)h = 144h 0Fh (P+33)h = 13Dh 00h (P+3B)h = 145h 00h Number of identical banks within Bank Region 2 (P+34)h = 13Eh (P+35)h = 13Fh (P+36)h = 140h (P+37)h = 141h 11h 00h 00h 02h (P+3C)h = 146h (P+3D)h = 147h (P+3E)h = 148h (P+3F)h = 149h 11h Number of program or erase operations allowed in Bank Region 2: Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is programming Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 00h Number of program or erase operations allowed in other banks while a bank in this region is erasing Bits 0-3: Number of simultaneous program operations Bits 4-7: Number of simultaneous erase operations 01h Types of erase block regions in Bank Region 2 n = number of erase block regions with contiguous samesize erase blocks. Symmetrically blocked banks have one blocking region.(2) (P+38)h = 142h 06h (P+40)h = 14Ah 07h (P+39)h = 143h 00h (P+41)h = 14Bh 00h (P+3A)h = 144h 00h (P+42)h = 14Ch 00h (P+3B)h = 145h 02h (P+43)h = 14Dh 02h (P+3C)h = 146h 64h (P+44)h = 14Eh 64h (P+3D)h = 147h 00h (P+45)h = 14Fh 00h (P+3E)h = 148h 02h (P+3F)h = 149h 03h (P+40)h = 14Ah 03h (P+41)h = 14Bh 00h (P+42)h = 14Ch 80h (P+43)h = 14Dh 00h (P+46)h = 150h (P+47)h = 151h Bank Region 2 Erase Block Type 1 Information Bits 0-15: n+1 = number of identical-sized erase blocks Bits 16-31: n×256 = number of bytes in erase block region Bank Region 2 (Erase Block Type 1) Minimum block erase cycles × 1000 02h Bank Region 2 (Erase Block Type 1): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 03h Bank Region 2 (Erase Block Type 1):Page mode and Synchronous mode capabilities (defined in Table 42) Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved Bank Region 2 Erase Block Type 2 Information Bits 0-15: n+1 = number of identical-sized erase blocks Bits 16-31: n×256 = number of bytes in erase block region 81/98 M58LT128GST, M58LT128GSB 13 Part Numbering Flash memory (top) Flash memory (bottom) Description Offset Data (P+44)h = 14Eh 64h (P+45)h = 14Fh 00h (P+46)h = 150h (P+47)h = 151h Offset Data Bank Region 2 (Erase Block Type 2) Minimum block erase cycles × 1000 02h Bank Region 2 (Erase Block Type 2): BIts per cell, internal ECC Bits 0-3: bits per cell in erase region Bit 4: reserved for “internal ECC used” BIts 5-7: reserved 03h Bank Region 2 (Erase Block Type 2): Page mode and Synchronous mode capabilities (defined in Table 42) Bit 0: Page-mode reads permitted Bit 1: Synchronous reads permitted Bit 2: Synchronous writes permitted Bits 3-7: reserved (P+48)h = 152h (P+48)h = 152h Feature Space definitions (P+49)h = 153h (P+43)h = 153h Reserved 1. The variable P is a pointer which is defined at CFI offset 015h. 2. Bank Regions. There are two Bank Regions, see Table 30 to Table 32 for the M58LT128GST and Table 33 to Table 35 for the M58LT128GSB. 82/98 M58LT128GST, M58LT128GSB 13 Part Numbering Appendix C Flowcharts and Pseudo Codes Figure 19. Program Flowchart and Pseudo Code Start program_command (addressToProgram, dataToProgram) {: writeToFlash (addressToProgram, 0x40); /*writeToFlash (addressToProgram, 0x10);*/ /*see note (3)*/ Write 40h or 10h (3) writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write Address & Data do { status_register=readFlash (addressToProgram); "see note (3)"; /* E or G must be toggled*/ Read Status Register (3) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06170b 1. Status check of SR1 (Protected Block), SR3 (VPP Invalid) and SR4 (Program Error) can be made after each program operation or after a sequence. 2. If an error is found, the Status Register must be cleared before further Program/Erase Controller operations. 3. Any address within the bank can equally be used. 83/98 M58LT128GST, M58LT128GSB 13 Part Numbering Figure 20. Buffer Program Flowchart and Pseudo Code Start Buffer Program E8h Command, Start Address status_register=readFlash (Start_Address); Read Status Register SR7 = 1 Buffer_Program_command (Start_Address, n, buffer_Program[] ) /* buffer_Program [] is an array structure used to store the address and data to be programmed to the Flash memory (the address must be within the segment Start Address and Start Address+n) */ { do {writeToFlash (Start_Address, 0xE8) ; NO } while (status_register.SR7==0); YES writeToFlash (Start_Address, n); Write n(1), Start Address Write Buffer Data, Start Address writeToFlash (buffer_Program[0].address, buffer_Program[0].data); /*buffer_Program[0].address is the start address*/ X=0 X=n x = 0; YES while (x<n) NO Write Next Buffer Data, Next Program Address(2) { writeToFlash (buffer_Program[x+1].address, buffer_Program[x+1].data); x++; X=X+1 } Program Buffer to Flash Confirm D0h writeToFlash (Start_Address, 0xD0); Read Status Register SR7 = 1 do {status_register=readFlash (Start_Address); NO } while (status_register.SR7==0); YES Full Status Register Check(3) full_status_register_check(); } End AI08913b 1. n + 1 is the number of data being programmed. 2. Next Program data is an element belonging to buffer_Program[].data; Next Program address is an element belonging to buffer_Program[].address. 3. Routine for Error Check by reading SR3, SR4 and SR1. 84/98 M58LT128GST, M58LT128GSB 13 Part Numbering Figure 21. Program Suspend & Resume Flowchart and Pseudo Code Start program_suspend_command ( ) { writeToFlash (any_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if program has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR2 = 1 NO Program Complete YES Write FFh Read data from another address if (status_register.SR2==0) /*program completed */ { writeToFlash (bank_address, 0xFF) ; read_data ( ) ; /*read data from another block*/ /*The device returns to Read Array (as if program/erase suspend was not issued).*/ } else Write D0h Write FFh Write 70h(1) Read Status Register { writeToFlash (bank_address, 0xFF) ; read_data ( ); /*read data from another address*/ writeToFlash (any_address, 0xD0) ; /*write 0xD0 to resume program*/ writeToFlash (bank_address, 0x70) ; /*read status register to check if erase has completed */ } } Program Continues with Bank in Read Status Register Mode AI10117 1. The Read Status Register command (Write 70h) can be issued just before or just after the Program Resume command. 85/98 M58LT128GST, M58LT128GSB 13 Part Numbering Figure 22. Block Erase Flowchart and Pseudo Code Start erase_command ( blockToErase ) { writeToFlash (blockToErase, 0x20) ; /*see note (2) */ Write 20h (2) writeToFlash (blockToErase, 0xD0) ; /* only A12-A20 are significannt */ /* Memory enters read status state after the Erase Command */ Write Block Address & D0h do { status_register=readFlash (blockToErase) ; /* see note (2) */ /* E or G must be toggled*/ Read Status Register (2) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1) YES Command Sequence Error (1) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; YES SR4, SR5 = 1 if ( (status_register.SR4==1) && (status_register.SR5==1) ) /* command sequence error */ error_handler ( ) ; NO SR5 = 0 NO Erase Error (1) if ( (status_register.SR5==1) ) /* erase error */ error_handler ( ) ; YES SR1 = 0 NO Erase to Protected Block Error (1) if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06174b 1. If an error is found, the Status Register must be cleared before further Program/Erase operations. 2. Any address within the bank can equally be used. 86/98 M58LT128GST, M58LT128GSB 13 Part Numbering Figure 23. Erase Suspend & Resume Flowchart and Pseudo Code Start erase_suspend_command ( ) { writeToFlash (bank_address, 0xB0) ; Write B0h writeToFlash (bank_address, 0x70) ; /* read status register to check if erase has already completed */ Write 70h do { status_register=readFlash (bank_address) ; /* E or G must be toggled*/ Read Status Register SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR6 = 1 NO Erase Complete if (status_register.SR6==0) /*erase completed */ { writeToFlash (bank_address, 0xFF) ; YES read_data ( ) ; /*read data from another block*/ /*The device returns to Read Array (as if program/erase suspend was not issued).*/ Write FFh Read data from another block } else Write D0h Write FFh Write 70h(1) Read Status Register { writeToFlash (bank_address, 0xFF) ; read_program_data ( ); /*read or program data from another address*/ writeToFlash (bank_address, 0xD0) ; /*write 0xD0 to resume erase*/ writeToFlash (bank_address, 0x70) ; /*read status register to check if erase has completed */ } } Erase Continues with Bank in Read Status Register Mode AI10116 1. The Read Status Register command (Write 70h) can be issued just before or just after the Erase Resume command. 87/98 M58LT128GST, M58LT128GSB 13 Part Numbering Figure 24. Protection Register Program Flowchart and Pseudo Code Start protection_register_program_command (addressToProgram, dataToProgram) {: writeToFlash (addressToProgram, 0xC0) ; /*see note (3) */ Write C0h (3) writeToFlash (addressToProgram, dataToProgram) ; /*Memory enters read status state after the Program Command*/ Write Address & Data do { status_register=readFlash (addressToProgram) ; /* see note (3) */ /* E or G must be toggled*/ Read Status Register (3) SR7 = 1 NO } while (status_register.SR7== 0) ; YES SR3 = 0 NO VPP Invalid Error (1, 2) if (status_register.SR3==1) /*VPP invalid error */ error_handler ( ) ; NO Program Error (1, 2) if (status_register.SR4==1) /*program error */ error_handler ( ) ; NO Program to Protected Block Error (1, 2) YES SR4 = 0 YES SR1 = 0 if (status_register.SR1==1) /*program to protect block error */ error_handler ( ) ; YES End } AI06177b 88/98 M58LT128GST, M58LT128GSB 13 Part Numbering Figure 25. Buffer Enhanced Factory Program Flowchart and Pseudo Code SETUP PHASE Buffer_Enhanced_Factory_Program_Command (start_address, DataFlow[]) { Start VerifyTargeted Block Protection Status Verify Block Protection Status YES if block protected Return Device to Read Mode Protected Block NO Write FFFFh to Address WA1 Read Mode Write 80h to Address WA1 writeToFlash (start_address, 0x80) ; Write D0h to Address WA1 writeToFlash (start_address, 0xD0) ; do { do { status_register = readFlash (start_address); Read Status Register NO SR7 = 0 YES NO Initialize count X=0 SR4 = 1 Read Status Register SR3 and SR1for errors Write PDX Address WA1 Exit Increment Count X=X+1 NO if (status_register.SR4==1) { /*error*/ if (status_register.SR3==1) error_handler ( ) ;/*VPP error */ if (status_register.SR1==1) error_handler ( ) ;/* Locked Block */ } PROGRAM AND while (status_register.SR7==1) VERIFY PHASE x=0; /* initialize count */ do { writeToFlash (start_address, DataFlow[x]); x++; X = 32 }while (x<32) do { YES Read Status Register NO status_register = readFlash (start_address); }while (status_register.SR0==1) SR0 = 0 YES NO Last data? } while (not last data) YES Write FFFFh to Address = NOT WA1 Read Status Register NO SR7 = 1 writeToFlash (another_block_address, FFFFh) EXIT PHASE do { status_register = readFlash (start_address) }while (status_register.SR7==0) YES Full Status Register Check End full_status_register_check(); } AI10658 1. For how to check the targeted block protection status, refer to the Application Note concerning the device security features. 89/98 M58LT128GST, M58LT128GSB 13 Part Numbering Appendix D Command Interface state tables Table 46. Command Interface States - Modify Table, Next State Command Input(1) Current CI State Read Array (FFh)(2) Ready Ready Lock/CR Setup Program Setup (10/40h) (3)(4) Buffer Program (E8h)(3)(4) Block Erase, Setup (20h) BEFP Setup (80h) (3)(4) Buffer Program Setup Program Setup Erase Setup (3)(4) Ready (Lock Error) Busy (70h) (50h)(5) Program Suspend (90h, 98h) Program Busy Program Busy Program Suspend Buffer Program Load 1 (give word count load (N-1)); Buffer if N=0 go to Buffer Program Confirm. Else (N not =0) go to Buffer Program Load 2 (data load) Buffer Buffer Program Confirm when count =0; Else Buffer Program Load 2 (note: Buffer Program will fail at this point if any block address is different from the first address) Load 2 Confirm Buffer Program Busy Ready (error) Busy Ready (error) Buffer Program Suspend Buffer Program Busy Buffer Program Busy Suspend Buffer Program Suspend Buffer Program Busy Buffer Program Suspend Setup Ready (error) Erase Busy Ready (error) Busy Erase Suspend Program in Erase Suspend Buffer Program Setup in Erase Suspend Erase Suspend Setup Busy Suspend Erase Suspend Erase Busy Erase Suspend Read Electronic Signature, Read CFI Query Ready (Lock Error) Program Suspend Program Busy Load 1 90/98 Clear status Register Ready Ready Setup Program in Erase Suspend Read Status Register Program Busy Suspend Buffer Program Buffer Program, Program/ Erase Suspend (B0h) BEFP Setup Setup Program Erase Confirm P/E Resume, BEFP Confirm(D0h) Erase Busy Erase Busy Erase Suspend Program Busy in Erase Suspend Program Suspend in Erase Suspend Program Busy in Erase Suspend Program Suspend in Erase Suspend Program Busy in Erase Suspend Program Busy in Erase Suspend Program Suspend in Erase Suspend M58LT128GST, M58LT128GSB 13 Part Numbering Command Input(1) Current CI State Read Array (FFh)(2) Buffer Program in Erase Suspend (3)(4) Buffer Program (E8h)(3)(4) Block Erase, Setup (20h) Erase Confirm P/E Resume, BEFP Confirm(D0h) BEFP Setup (80h) (3)(4) (3)(4) Buffer Program, Program/ Erase Suspend (B0h) Read Status Register Clear status Register (70h) (50h)(5) Read Electronic Signature, Read CFI Query (90h, 98h) Setup Buffer Program Load 1 in Erase Suspend (give word count load (N-1)); if N=0 go to Buffer Program confirm. Else (N not =0) go to Buffer Program Load 2 Buffer Load 1 Buffer Program Load 2 in Erase Suspend (data load) Buffer Load 2 Buffer Program Confirm in Erase Suspend when count =0; Else Buffer Program Load 2 in Erase Suspend (note: Buffer Program will fail at this point if any block address is different from the first address) Confirm Busy Suspend Lock/CR Setup in Erase Suspend Buffer EFP Program Setup (10/40h) Setup Buffer Program Busy in Erase Suspend Ready (error) Ready (error) Buffer Program Suspend in Erase Suspend Buffer Program Busy in Erase Suspend Buffer Program Busy in Erase Suspend Buffer Program Suspend in Erase Suspend Buffer Program Busy in Erase Suspend Buffer Program Suspend in Erase Suspend Erase Suspend (Lock Error) Erase Suspend Erase Suspend (Lock Error) Ready (error) BEFP Busy Ready (error) Busy BEFP Busy(6) 1. CI = Command Interface, CR = Configuration Register, BEFP = Buffer Enhanced Factory Program, P/E. C. = Program/ Erase Controller. 2. At Power-Up, all banks are in Read Array mode. Issuing a Read Array command to a busy bank, results in undetermined data output. 3. The two cycle command should be issued to the same bank address. 4. If the P/E.C. is active, both cycles are ignored. 5. The Clear Status Register command clears the Status Register error bits except when the P/E.C. is busy or suspended. 6. BEFP is allowed only when Status Register bit SR0 is set to ‘0’. BEFP is busy if Block Address is first BEFP Address. Any other commands are treated as data. 91/98 M58LT128GST, M58LT128GSB 13 Part Numbering Table 47. Command Interface States - Modify Table, Next Output State Command Input(1)(2) Current CI State Read Array (FFh)(3) Program Setup (10/ 40h)(4)(5) Buffer Program (E8h) Block Erase, Setup (20h)(4)(5) Erase Confirm BEFP Setup (80h) P/E Resume, BEFP Confirm Program/ Erase Suspend (B0h) Read Status Register (70h) Clear status Register (50h) Read Electronic signature, Read CFI Query (90h, 98h) (D0h)(4)(5) Program Setup Erase Setup Program in Erase Suspend BEFP Setup BEFP Busy Buffer Program Setup Buffer Program Load 1 Buffer Program Load 2 Status Register Buffer Program Confirm Buffer Program Setup in Erase Suspend Buffer Program Load 1 in Erase Suspend Buffer Program Load 2 in Erase Suspend Buffer Program Confirm in Erase Suspend Lock/CR Setup Lock/CR Setup in Erase Suspend Ready Program Busy Erase Busy Buffer Program Busy Program/Erase Suspend Buffer Program Suspend Program Busy in Erase Suspend Buffer Program Busy in Erase Suspend Program Suspend in Erase Suspend Buffer Program Suspend in Erase Suspend 92/98 Array Status Register Output Unchanged Status Register Output Unchanged Electronic Signature/ CFI M58LT128GST, M58LT128GSB 13 Part Numbering 1. The output state shows the type of data that appears at the outputs if the bank address is the same as the command address. A bank can be placed in Read Array, Read Status Register, Read Electronic Signature or Read CFI mode, depending on the command issued. Each bank remains in its last output state until a new command is issued to that bank. The next state does not depend on the bank output state. 2. CI = Command Interface, CR = Configuration Register, BEFP = Buffer Enhanced Factory Program, P/E. C. = Program/ Erase Controller. 3. At Power-Up, all banks are in Read Array mode. Issuing a Read Array command to a busy bank, results in undetermined data output. 4. The two cycle command should be issued to the same bank address. 5. If the P/E.C. is active, both cycles are ignored. Table 48. Command Interface States - Lock Table, Next State Command Input(1)(2) Current CI State Lock/CR Setup(60h)(2) Ready Lock/CR Setup Lock/CR Setup Ready (Lock error) Program Erase Illegal Command(4) Ready Ready WSM Operation Completed N/A Ready (Lock error) N/A N/A Busy Program Busy Ready Suspend Program Suspend N/A Setup Buffer Program Load 1 (give word count load (N-1) N/A Buffer Program Load 2(5) Exit see note(5) N/A Buffer Load 2 Buffer Program Confirm when count =0; Else Buffer Program Load 2 (note: Buffer Program will fail at this point if any block address is different from the first address) N/A Confirm Ready (error) N/A Busy Buffer Program Busy Ready Suspend Buffer Program Suspend N/A Setup Ready (error) N/A Busy Erase Busy Ready Lock/CR Setup in Erase Suspend Erase Suspend N/A Setup Program Busy in Erase Suspend N/A Busy Program Busy in Erase Suspend Erase Suspend Suspend Program Suspend in Erase Suspend Setup Buffer Program Load 1 in Erase Suspend (give word count load (N-1)) Buffer Load 1 Buffer Program in Erase Suspend (XXXXh)(3) Program Busy Suspend Program in Erase Suspend Block Address (WA0) (03h) Setup Buffer Load 1 Buffer Program Set CR Confirm Buffer Program Load 2 in Erase Suspend(6) Exit see note (6) Buffer Load 2 Buffer Program Confirm in Erase Suspend when count =0; Else Buffer Program Load 2 in Erase Suspend (note: Buffer Program will fail at this point if any block address is different from the first address) Confirm Ready (error) Busy Buffer Program Busy in Erase Suspend Suspend Buffer Program Suspend in Erase Suspend N/A 93/98 M58LT128GST, M58LT128GSB 13 Part Numbering Command Input(1)(2) Current CI State Lock/CR Setup(60h)(2) Lock/CR Setup in Erase Suspend Erase Suspend (Lock error) Set CR Confirm Block Address (WA0) (03h) (XXXXh)(3) Erase Suspend (Lock error) Erase Suspend Setup Illegal Command(4) Ready (error) WSM Operation Completed N/A N/A BEFP Busy BEFP Busy(7) Exit BEFP Busy(7) N/A 1. CI = Command Interface, CR = Configuration Register, BEFP = Buffer Enhanced Factory Program, P/E. C. = Program/ Erase Controller, WA0 = Address in a block different from first BEFP address. 2. If the P/E.C. is active, both cycles are ignored. 3. BEFP Exit when Block Address is different from first Block Address and data are FFFFh. 4. Illegal commands are those not defined in the command set. 5. if N=0 go to Buffer Program Confirm. Else (N ≠ 0) go to Buffer Program Load 2 (data load). 6. if N=0 go to Buffer Program Confirm in Erase Suspend. Else (N ≠ 0) go to Buffer Program Load 2 in Erase Suspend. 7. BEFP is allowed only when Status Register bit SR0 is set to ‘0’. BEFP is busy if Block Address is first BEFP Address. Any other commands are treated as data. 94/98 M58LT128GST, M58LT128GSB Table 49. 13 Part Numbering Command Interface States - Lock Table, Next Output State Command Input(1)(2) Current CI State Lock/CR Setup Set CR Confirm (60h)(3) (03h) BEFP Exit (FFFFh)(4) Illegal Command(5) WSM Operation Completed Program Setup Erase Setup Program in Erase Suspend BEFP Setup BEFP Busy Buffer Program Setup Buffer Program Load 1 Status Register Buffer Program Load 2 Buffer Program Confirm Buffer Program Setup in Erase Suspend Buffer Program Load 1 in Erase Suspend Buffer Program Load 2 in Erase Suspend Buffer Program Confirm in Erase Suspend Output Unchanged Lock/CR Setup Array Lock/CR Setup in Erase Suspend Status Register Ready Program Busy Erase Busy Buffer Program Busy Program/Erase Suspend Status Register Buffer Program Suspend Output Unchanged Array Output Unchanged Program Busy in Erase Suspend Buffer Program Busy in Erase Suspend Program Suspend in Erase Suspend Buffer Program Suspend in Erase Suspend 1. The output state shows the type of data that appears at the outputs if the bank address is the same as the command address. A bank can be placed in Read Array, Read Status Register, Read Electronic Signature or Read CFI mode, depending on the command issued. Each bank remains in its last output state until a new command is issued to that bank. The next state does not depend on the bank's output state. 95/98 13 Part Numbering M58LT128GST, M58LT128GSB 2. CI = Command Interface, CR = Configuration Register, BEFP = Buffer Enhanced Factory Program, P/E. C. = Program/ Erase Controller, WA0 = Address in a block different from first BEFP address. 3. If the P/E.C. is active, both cycles are ignored. 4. BEFP Exit when Block Address is different from first Block Address and data are FFFFh. 5. Illegal commands are those not defined in the command set. 96/98 M58LT128GST, M58LT128GSB 14 14 Revision history Revision history Table 50. Document Revision History Date Version Revision Details 16-Nov-2004 0.1 First Issue. 10-Dec-2004 0.2 Asynchronous Page Read mode added in Summary description, Section 3: Bus operations. Figure 10: Asynchronous Page Read AC Waveforms updated and Table 22: Asynchronous Read AC Characteristics for tAVQV1. 17-Jan-2004 0.3 WP and R pins removed from Figure 1: Logic Diagram. WP removed from Figure 15: Write AC Waveforms, Write Enable Controlled and Figure 16: Write AC Waveforms, Chip Enable Controlled. 80ns speed class chagned into 85ns. DU pins changed into NC in Figure 2: TBGA64 Connections (Top view through package). tWHQV removed from Figure 15, Figure 16. 20-Jun-2005 0.4 Table 22, Table 23 and Table 26 updated. Table 24 updated; tWHQV removed and tAVWH, tELQV, tELKV, tGHWL, tWHAV, and tWHAX timings added. Table 25 updated, tWHQV removed, and tAVEH, tEHAX, tEHGL, tELKV, and tGHEL added. 21-Jun-2005 0.5 tGHTZ added inTable 22: Asynchronous Read AC Characteristics and Table 23: Synchronous Read AC Characteristics. Burst frequency chagned from 54 to 52MHz. 85ns speed class removed. tAVQV1 changed to 25ns. 29-Sep-2005 1.0 VIO maximum value updated in Table 17: Absolute Maximum Ratings. tAVLH and tLLLH updated in Table 22: Asynchronous Read AC Characteristics. tAVKH, tELKH and tLLKH updated in Table 23: Synchronous Read AC Characteristics. tAVLH, tLLLH and tELLH updated in Table 24: Write AC Characteristics, Write Enable Controlled and Table 25: Write AC Characteristics, Chip Enable Controlled. 97/98 M58LT128GST, M58LT128GSB Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not authorized for use as critical components in life support devices or systems without express written approval of STMicroelectronics. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners © 2005 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com 98/98