TSC GBU406

GBU401 THRU GBU407
Single Phase 4.0 AMPS. Glass Passivated Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
4.0 Amperes
GBU
Features
UL Recognized File # E-96005
Ideal for printed circuit board
Reliable low cost construction
Plastic material has Underwriters Laboratory
Flammability Classification 94V-0
Surge overload rating to 150 amperes peak
High temperature soldering guaranteed:
260oC / 10 seconds / .375”, (9.5mm) lead
lengths at 5 lbs., (2.3kg) tension
.310(7.90)
.290(7.40)
0.125(3.2)x45
CHAMFER
.160(4.1)
.140(3.5)
.075
(1.9)R
.085(2.16)
.065(1.65)
.100(2.54)
.085(2.16)
Mechanical Data
.080(2.03)
.060(1.52)
.050(1.27)
.040(1.02)
9
TYP.
.740(18.8)
.720(18.3)
.085(2.16)
.075(1.90)
.710(18.0)
.690(17.5)
.190(4.83)
.210(5.33)
.080(2.03)
.065(1.65)
Case: Molded plastic body
Terminals: Leads solderable per MIL-STD-750,
Method 2026
Weight: 0. 3 ounce, 8.0 grams
Mounting torque: 5 in. lbs. Max.
.140(3.56)
.130(3.30)
.880(22.3)
.860(21.8)
.020R(TYP.)
.022(0.56)
.018(0.46)
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol GBU GBU GBU GBU GBU GBU GBU Units
Type Number
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
@TC = 100℃
Peak Forward Surge Current, 8.3 ms Single
Half Sne-wave Superimposed on Rated Load
(JEDEC method )
Maximum Instantaneous Forward Voltage
@ 4.0A
Maximum DC Reverse Current @ TA=25℃
at Rated DC Blocking Voltage @ TA=125℃
Typical Thermal Resistance (Note 1)
(Note 2)
Typical Junction Capacitance (Note 3)
Operating Temperature Range
VRRM
VRMS
VDC
401
402
403
404
405
406
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800 1000
560 700
800 1000
407
V
V
V
I(AV)
4.0
A
IFSM
150
A
VF
1.0
V
5.0
500
20
4.0
uA
uA
℃/W
IR
RθJA
RθJC
Cj
100
45
-55 to +150
-55 to + 150
TJ
Storage Temperature Range
TSTG
Notes: 1. Mounted on P.C.B. with 0.5 x 0.5” (12 x 12mm) Copper Pads and 0.375” 9.5mm) Lead
Length.
2. Mounted on Al. Plate of 2” x 3” x 0.25”
3. Measured at 1.0MHZ and Applied Reverse Voltage of 4.0 Volts.
- 648 -
pF
℃
℃
RATINGS AND CHARACTERISTIC CURVES (GBU401 THRU GBU407)
FIG.1- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT PER BRIDGE ELEMENT
FIG.2-MAXIMUM FORWARD CURRENT DERATING
CURVE
175
AVERAGE FORWARD CURRENT. (A)
PEAK FORWARD SURGE CURRENT. (A)
5
150
Tj=150 C
8.3ms Single Half Sine Wave
125
100
75
50
25
4
3
2
HEAT-SINK MOUNTG
2" x 3" x 0.25" AI-PLATE
1
0
1
2
10
5
20
50
100
50
0
FIG.4- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
500
40
100
INSTANTANEOUS REVERSE CURRENT. (mA)
INSTANTANEOUS FORWARD CURRENT. (A)
100
20
10
4.0
2.0
1.0
Tj=125 0C
10
1
0.1
Tj=25 0C
Pulse Width=300ms
1% Duty Cycle
Tj=25 0C
0.2
0
0.6
150
o
FIG.3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER BRIDGE ELEMENT
0.4
100
CASE TEMPERATURE. ( C)
NUMBER OF CYCLES AT 60Hz
50-400V
600-1000V
0.01
0.7
0.8
0.9
1.0
1.1
1.2
1.3
0
INSTANTANEOUSFORWARD VOLTAGE. (V)
20
40
60
80
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
- 649 -
100