GBU401 THRU GBU407 Single Phase 4.0 AMPS. Glass Passivated Bridge Rectifiers Voltage Range 50 to 1000 Volts Current 4.0 Amperes GBU Features UL Recognized File # E-96005 Ideal for printed circuit board Reliable low cost construction Plastic material has Underwriters Laboratory Flammability Classification 94V-0 Surge overload rating to 150 amperes peak High temperature soldering guaranteed: 260oC / 10 seconds / .375”, (9.5mm) lead lengths at 5 lbs., (2.3kg) tension .310(7.90) .290(7.40) 0.125(3.2)x45 CHAMFER .160(4.1) .140(3.5) .075 (1.9)R .085(2.16) .065(1.65) .100(2.54) .085(2.16) Mechanical Data .080(2.03) .060(1.52) .050(1.27) .040(1.02) 9 TYP. .740(18.8) .720(18.3) .085(2.16) .075(1.90) .710(18.0) .690(17.5) .190(4.83) .210(5.33) .080(2.03) .065(1.65) Case: Molded plastic body Terminals: Leads solderable per MIL-STD-750, Method 2026 Weight: 0. 3 ounce, 8.0 grams Mounting torque: 5 in. lbs. Max. .140(3.56) .130(3.30) .880(22.3) .860(21.8) .020R(TYP.) .022(0.56) .018(0.46) Dimensions in inches and (millimeters) Maximum Ratings and Electrical Characteristics Rating at 25℃ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% Symbol GBU GBU GBU GBU GBU GBU GBU Units Type Number Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current @TC = 100℃ Peak Forward Surge Current, 8.3 ms Single Half Sne-wave Superimposed on Rated Load (JEDEC method ) Maximum Instantaneous Forward Voltage @ 4.0A Maximum DC Reverse Current @ TA=25℃ at Rated DC Blocking Voltage @ TA=125℃ Typical Thermal Resistance (Note 1) (Note 2) Typical Junction Capacitance (Note 3) Operating Temperature Range VRRM VRMS VDC 401 402 403 404 405 406 50 35 50 100 70 100 200 140 200 400 280 400 600 420 600 800 1000 560 700 800 1000 407 V V V I(AV) 4.0 A IFSM 150 A VF 1.0 V 5.0 500 20 4.0 uA uA ℃/W IR RθJA RθJC Cj 100 45 -55 to +150 -55 to + 150 TJ Storage Temperature Range TSTG Notes: 1. Mounted on P.C.B. with 0.5 x 0.5” (12 x 12mm) Copper Pads and 0.375” 9.5mm) Lead Length. 2. Mounted on Al. Plate of 2” x 3” x 0.25” 3. Measured at 1.0MHZ and Applied Reverse Voltage of 4.0 Volts. - 648 - pF ℃ ℃ RATINGS AND CHARACTERISTIC CURVES (GBU401 THRU GBU407) FIG.1- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER BRIDGE ELEMENT FIG.2-MAXIMUM FORWARD CURRENT DERATING CURVE 175 AVERAGE FORWARD CURRENT. (A) PEAK FORWARD SURGE CURRENT. (A) 5 150 Tj=150 C 8.3ms Single Half Sine Wave 125 100 75 50 25 4 3 2 HEAT-SINK MOUNTG 2" x 3" x 0.25" AI-PLATE 1 0 1 2 10 5 20 50 100 50 0 FIG.4- TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT 500 40 100 INSTANTANEOUS REVERSE CURRENT. (mA) INSTANTANEOUS FORWARD CURRENT. (A) 100 20 10 4.0 2.0 1.0 Tj=125 0C 10 1 0.1 Tj=25 0C Pulse Width=300ms 1% Duty Cycle Tj=25 0C 0.2 0 0.6 150 o FIG.3- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS PER BRIDGE ELEMENT 0.4 100 CASE TEMPERATURE. ( C) NUMBER OF CYCLES AT 60Hz 50-400V 600-1000V 0.01 0.7 0.8 0.9 1.0 1.1 1.2 1.3 0 INSTANTANEOUSFORWARD VOLTAGE. (V) 20 40 60 80 PERCENT OF RATED PEAK REVERSE VOLTAGE. (%) - 649 - 100