5.0 AMPS. Surface Mount Schottky Barrier Rectifiers
Voltage Range
40 Volts
Current
5.0 Amperes
SMC/DO-214AB
Features
a
a
a
a
a
a
For surface mounted application
Metal to silicon rectifier, majority carrier conduction
Low forward voltage drop
Easy pick and place
High surge current capability
Plastic material used carriers Underwriters
Laboratory Classification 94V-0
a Epitaxial construction
a High temperature soldering:
o
260 C / 10 seconds at terminals
.245(6.22)
.220(5.59)
.280(7.11)
.260(6.60)
.012(.31)
.006(.15)
.103(2.62)
.079(2.00)
Mechanical Data
a
a
a
a
a
.129(3.27)
.118(3.0)
Case: Molded plastic
Terminals: Solder plated
Polarity: Indicated by cathode band
Packaging: 16mm tape per EIA STD RS-481
Weight: 0.21 gram
.008(.20)
.004(.10)
.060(1.52)
.030(0.76)
.320(8.13)
.305(7.75)
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol
Type Number
SKL54C
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at TL (See Fig. 1)
Peak Forward Surge Current, 8.3 ms Single Half
Sine-wave Superimposed on Rated Load
(JEDEC method )
Maximum Instantaneous Forward Voltage
(Note 1) @5.0A
Maximum DC Reverse Current @ TA =25 at
Rated DC Blocking Voltage
@ TA=75
Typical Thermal Resistance ( Note 2 )
Operating Temperature Range
Storage Temperature Range
Units
VRRM
VRMS
VDC
40
28
40
V
V
V
I(AV)
5.0
A
IFSM
150
A
VF
0.40
V
IR
5
50
10
75
-55 to +125
-55 to +150
mA
mA
RJC
RJA
TJ
TSTG
Notes: 1. Pulse Test with PW=300 usec, 1% Duty Cycle
2. Measured on P.C.Board with 0.6 x 0.6” (16.0 x 16.0mm) Copper Pad Areas.
- 902 -
/W
/W
RATINGS AND CHARACTERISTIC CURVES ( SKL54C)
FIG.1- MAXIMUM FORWARD CURRENT DERATING
CURVE
FIG.2-MAXIMUM NON-REPETIVE PEAK FORWARD
SURGE CURRENT
150
RESISTIVEOR
INDUCTIVE LOAD
4
3
2
1
0
AT RATED TL
8.3msSingle Half Sine Wave
PEAK FORWARD SURGE CURRENT (A)
AVERAGE FORWARD CURRENT (A)
5
125
100
75
50
25
0
50
100
JEDEC Method
150
1
10
100
NUMBER OF CYCLES AT 60HZ
LEAD TEMPERATURE.(c)
FIG.3-TYPICAL FORWARD CHARACTERISTICS
FIG.4-TYPICAL REVERSE CHARACTERISTICS
20
40
10
INSTANEDLIS REVERSE CURRENT.(mA)
INSTANTANEOUS FORWARD CURRENT(A)
TA=125 C
10.0
PULSE WIDTH=300 s
1%DUTY GYGLE
1.0
0.1
0.01
0
2
4
8
6
1.0
1.2
1.4
1.0
TA=75 C
0.1
0.01
TA=25 C
0.001
1.5
TRANSCIENT THERMAL IMPEDANCE. (oC/W )
JUNCTION CAPACITSNCE(pF)
1000
Tj=25 C
f=1.0MHZ
Vsig=50mvp-p
100
1
1.0
20
40
60
100
80
140
120
FIG.6- TYPICAL TRANSIENT THERMAL
CHARACTERISTICS
FIG.5-TYPICAL JUNCTION CAPACITANCE
10
0
PERCENT OF RATED PEAK REVERSE VOLTAGE.(%)
FORWARD VOLTAGE(V)
10
100
100
10.0
1
0.1
0.01
0.1
1
PULSE DURATION,(sec)
REVERSE VOLTAGE.(V)
- 41 -
10
100