MCC FST19035

MCC
FST19035
omponents
21201 Itasca Street Chatsworth
!"#
$
% !"#
THRU
FST19050
Features
•
•
•
•
200 Amp
Schottky Barrier
Rectifier
35 to 50 Volts
Metal of siliconrectifier, majonty carrier conducton
Guard ring for transient protection
Low power loss high efficiency
High surge capacity, High current capability
Maximum Ratings
•
•
POWERMOD
Operating Temperature: -65°C to +150°C
Storage Temperature: -65°C to +150°C
A
MCC
Part Number
FST19035
FST12040
FST12045
FST12050
Maximum
Recurrent
Peak Reverse
Voltage
35V
40V
45V
50V
Maximum
RMS Voltage
Maximum DC
Blocking
Voltage
24.5V
28V
31.5V
35V
N
E
C
35V
40V
45V
50V
B
L
M
D
Q
R
F
G
P
J
K
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
Typical Junction
Capacitance
IF(AV)
200 A
TA = 126°C
IFSM
1500A
8.3ms, half sine
VF
IR
.70V
4 mA
IFM = 100.0A;
TA = 25°C
TA = 25°C
DIMENSIONS
DIM
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
CJ
340pF
H
INCH
ES
MIN
1.995
.330
.495
.182
.990
1.490
1.500
.120
-----.240
.490
.330
.175
.035
.445
.890
Measured at
1.0MHz, VR=4.0V
www.mccsemi.com
MAX
2.005
.325
.505
.192
1.010
1.510
1.525
.130
.400
.260
.510
.350
.195
.045
.455
.910
MM
MIN
50.67
7.62
12.57
4.62
25.12
37.85
38.10
3.05
-----6.10
12.45
MAX
50.93
8.26
12.83
4.88
26.65
38.35
38.70
3.30
10.16
6.60
12.95
8.38
4.45
0.89
11.30
22.61
6.90
4.95
1.14
11.56
23.11
NOTE
∅
MCC
FST9035 thru FST19050
Figure 1
Typical Forward Characteristics
200
Figure 2
Forward Derating Curve
100
200
60
40
160
20
25°C
120
Amps 10
6
80
Amps
4
40
2
20
1
.6
0
.4
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
50
70
90
110
130
150
°C
.2
.1
0.8
0.6
1.0
1.4
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
2.0
1.8
Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 3
Junction Capacitance
1000
600
400
200
pF
TJ=25°C
100
60
40
20
10
.1
.2
.4
1
Volts
2
4
10
20
40
100
200
400
Junction Capacitance - pF versus
Reverse Voltage - Volts
www.mccsemi.com
1000
MCC
FST19035 thru FST19050
Figure 4
Typical Reverse Characteristics
Figure 5
Peak Forward Surge Current
1500
1000
600
400
1300
200
1000
100
800
60
Amps
40
600
200
20
0
TA=125°C
mAmps 1.5
1
2
4
6
60 80 100
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
1.3
1.2
1.1
.6
.4
TA=25°C
.2
10
40
Cycles
1.4
.1
8 10 20
20
40
60
80
100
120
Volts
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
www.mccsemi.com