EPCOS B88069X0690T502

Switching Spark Gap
CAS02X-069
Ordering code: B88069X0690T502
DC spark-over voltage 1) 2)
205 ... 230
V
Initial values
Ignition time tI after 150 hours in darkness 3)
at –20 °C
at +25; 125 °C
Electrical life time
Maximum increase of DC spark-over voltage
Switching operations at +25; 125 °C
Switching frequency 10 … 25 Hz
Switching frequency < 10Hz
Test circuit parameters
Open circuit voltage V0'
Loading resistance R
Discharge capacitance C
Inductance L
Discharge peak current IP
95
≤4
≤2
99.9
≤5
≤3
100
≤7
≤4
%
s
s
25
V
2 000 000
4 000 000
Ignitions
Ignitions
230
54
1.8
15
~ 280
Vac
kΩ
µF
µH
A
Insulation resistance at 100 Vdc
> 0.1
GΩ
Capacitance at 1 MHz
<2
pF
Weight
~ 1.5
g
Operation and storage temperature
-20 ... +125
°C
Climatic category (IEC 60068-1)
20/ 125/ 21
Marking, red
CS 230 YYMM O
CS
230
YY
MM
O
1)
2)
3)
- Series
- Nominal voltage
- Year of production
- Month of production
- Non radioactive
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode, after load
Time from capacitor charged to the first high voltage spark
Test circuit: Vac = 198 V; R = 36 kΩ; C = 2.2 µF
AB E / AB PM
Issue 06, 10.02.2004
Page 1 of 2
Switching Spark Gap
CAS02X-069
Ordering code: B88069X0690T502
Not to scale
Dimensions in mm
Non controlled document
 EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and
Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless
otherwise agreed.
AB E / AB PM
Issue 06, 10.02.2004
Page 2 of 2