LTC6803-2/LTC6803-4 Multicell Battery Stack Monitor DESCRIPTION FEATURES Measures Up to 12 Battery Cells in Series Stackable Architecture n Supports Multiple Battery Chemistries and Supercapacitors n Individually Addressable Serial Interface n 0.25% Maximum Total Measurement Error n Engineered for ISO26262 Compliant Systems n 13ms to Measure All Cells in a System n Passive Cell Balancing: – Integrated Cell Balancing MOSFETs – Ability to Drive External Balancing MOSFETs n Onboard Temperature Sensor and Thermistor Inputs n 1MHz Serial Interface with Packet Error Checking n Safe with Random Connection of Cells n Built-In Self Tests n Delta-Sigma Converter With Built-In Noise Filter n Open-Wire Connection Fault Detection n 12µA Standby Mode Supply Current n High EMI Immunity n 44-Lead SSOP Package The LTC®6803 is a 2nd generation, complete battery monitoring IC that includes a 12-bit ADC, a precision voltage reference, a high voltage input multiplexer and a serial interface. Each LTC6803 can measure up to 12 series connected battery cells or supercapacitors. Many LTC6803 devices can be stacked to measure the voltage of each cell in a long battery string. Each LTC6803-2/LTC6803-4 has an individually addressable serial interface, allowing up to 16 LTC6803-2/LTC6803-4 devices to interface to one control processor and operate simultaneously. Each cell input has an associated MOSFET switch for discharging overcharged cells. The LTC6803-2 connects the bottom of the stack to V– internally. It is pin compatible with the LTC6802-2, providing a drop-in upgrade. The LTC6803-4 separates the bottom of the stack from V–, improving cell 1 measurement accuracy. APPLICATIONS The related LTC6803-1 and LTC6803-3 offer a serial interface that allows the serial ports of multiple LTC6803-1 or LTC6803-3 devices to be daisy chained without optocouplers or isolators. n n n n n n The LTC6803 provides a standby mode to reduce supply current to 12µA. Furthermore, the LTC6803 can be powered from an isolated supply, providing a technique to reduce battery stack current draw to zero. Electric and Hybrid Electric Vehicles High Power Portable Equipment Backup Battery Systems Electric Bicycles, Motorcycles, Scooters L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks of Linear Technology Corporation. All other trademarks are the property of their respective owners. TYPICAL APPLICATION V+ + 12-CELL BATTERY OR CAPACITOR STRING Supply Current vs Modes of Operation LTC6803-4 DIE TEMP MUX REGISTERS AND CONTROL + 12-BIT ∆Σ ADC 1mA SERIAL DATA 4-BIT ADDRESS 100µA 50V ISOLATED DC/DC CONVERTER + VOLTAGE REFERENCE NEXT 12-CELL PACK BELOW V– 100k NTC 12V SUPPLY CURRENT NEXT 12-CELL PACK ABOVE 10µA 1µA 100nA 10nA EXTERNAL TEMP 1nA 100k HW SHUTDOWN STANDBY MEASURE 680324 TA01b 680324 TA01a 680324f 1 LTC6803-2/LTC6803-4 ABSOLUTE MAXIMUM RATINGS (Note 1) Total Supply Voltage (V+ to V–)..................................75V Input Voltage (Relative to V–) C0............................................................. –0.3V to 8V C12......................................................... –0.3V to 75V Cn (Note 5).......................... –0.3V to Min (8 • n, 75V) Sn (Note 5).......................... –0.3V to Min (8 • n, 75V) All Other Pins............................................ –0.3V to 7V Voltage Between Inputs Cn to Cn – 1.............................................. –0.3V to 8V Sn to Cn – 1.............................................. –0.3V to 8V C12 to C8................................................ –0.3V to 25V C8 to C4.................................................. –0.3V to 25V C4 to C0.................................................. –0.3V to 25V Operating Temperature Range LTC6803I..............................................–40°C to 85°C LTC6803H........................................... –40°C to 125°C Specified Temperature Range LTC6803I..............................................–40°C to 85°C LTC6803H........................................... –40°C to 125°C Junction Temperature............................................ 150°C Storage Temperature Range................... –65°C to 150°C Note: n = 1 to 12 PIN CONFIGURATION LTC6803-2 LTC6803-4 TOP VIEW V+ 1 C12 2 S12 TOP VIEW 44 CSBI V+ 1 44 CSBI 43 SDO C12 2 43 SDO 3 42 SDI S12 3 42 SDI C11 4 41 SCKI C11 4 41 SCKI S11 5 40 A3 S11 5 40 A3 C10 6 39 A2 C10 6 39 A2 S10 7 38 A1 S10 7 38 A1 C9 8 37 A0 C9 8 37 A0 S9 9 36 GPIO2 S9 9 36 GPIO2 C8 10 35 GPIO1 C8 10 35 GPIO1 S8 11 34 WDTB S8 11 34 WDTB C7 12 33 NC C7 12 33 TOS S7 13 32 TOS S7 13 32 VREG C6 14 31 VREG C6 14 31 VREF S6 15 30 VREF S6 15 30 VTEMP2 C5 16 29 VTEMP2 C5 16 29 VTEMP1 S5 17 28 VTEMP1 S5 17 28 NC C4 18 27 NC C4 18 27 V – S4 19 26 V – S4 19 26 C0 C3 20 25 S1 C3 20 25 S1 S3 21 24 C1 S3 21 24 C1 C2 22 23 S2 C2 22 23 S2 G PACKAGE 44-LEAD PLASTIC SSOP G PACKAGE 44-LEAD PLASTIC SSOP TJMAX = 150°C, θJA = 70°C/W TJMAX = 150°C, θJA = 70°C/W 680324f 2 LTC6803-2/LTC6803-4 ORDER INFORMATION LEAD FREE FINISH TAPE AND REEL PART MARKING* PACKAGE DESCRIPTION SPECIFIED TEMPERATURE RANGE LTC6803IG-2#PBF LTC6803IG-2#TRPBF LTC6803G-2 44-Lead Plastic SSOP –40°C to 85°C LTC6803IG-4#PBF LTC6803IG-4#TRPBF LTC6803G-4 44-Lead Plastic SSOP –40°C to 85°C LTC6803HG-2#PBF LTC6803HG-2#TRPBF LTC6803G-2 44-Lead Plastic SSOP –40°C to 125°C LTC6803HG-4#PBF LTC6803HG-4#TRPBF LTC6803G-4 44-Lead Plastic SSOP –40°C to 125°C Consult LTC Marketing for parts specified with wider operating temperature ranges. *The temperature grade is identified by a label on the shipping container. Consult LTC Marketing for information on non-standard lead based finish parts. For more information on lead free part marking, go to: http://www.linear.com/leadfree/ For more information on tape and reel specifications, go to: http://www.linear.com/tapeandreel/ ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the full operating + – temperature range, otherwise specifications are at TA = 25°C. V = 43.2V, V = 0V, unless otherwise noted. SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS DC Specifications VS VLSB VERR Supply Voltage, V+ Relative to V– VERR Specification Met Timing Specification Met l l 10 4 55 55 Measurement Resolution Quantization of the ADC l ADC Offset (Note 2) l –0.5 0.5 mV ADC Gain Error (Note 2) l –0.12 –0.22 0.12 0.22 % % Total Measurement Error (Note4) VCELL = –0.3V VCELL = 2.3V VCELL = 2.3V VCELL = 3.6V VCELL = 3.6V, LTC6803IG VCELL = 3.6V, LTC6803HG VCELL = 4.2V VCELL = 4.2V, LTC6803IG VCELL = 4.2V, LTC6803HG VCELL = 5V 2.3V < VTEMP < 4.2V, LTC6803IG 2.3V < VTEMP < 4.2V, LTC6803HG VCELL Cell Voltage Range Full-Scale Voltage Range VCM Common Mode Voltage Range Measured Relative to V– Range of Inputs Cn < 0.25% Gain Error, n = 2 to 11, LTC6803IG Die Temperature Measurement Error 1.5 V V l l –2.8 –5.1 –4.3 –7.9 –9 –5 –9.2 –10 l l –9.2 –10 l l l ±2.5 ±3 mV/Bit 2.8 5.1 4.3 7.9 9 5 9.2 10 9.2 10 mV mV mV mV mV mV mV mV mV mV mV mV –0.3 5 V l 1.8 5•n V Range of Inputs C0, C1 < 0.25% Gain Error, LTC6803IG l 0 5 V Range of Inputs Cn < 0.5% Gain Error, n = 2 to 11, LTC6803HG l 1.8 5•n V Range of Inputs C0, C1 < 0.5% Gain Error, LTC6803HG l 0 5 V Error in Measurement of 125°C 5 °C 680324f 3 LTC6803-2/LTC6803-4 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the full operating + – temperature range, otherwise specifications are at TA = 25°C. V = 43.2V, V = 0V, unless otherwise noted. SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS VREF Reference Pin Voltage RLOAD = 100k to V– 3.020 3.015 3.065 3.065 3.110 3.115 V V l Reference Voltage Temperature Coefficient 8 Reference Voltage Thermal Hysteresis 25°C to 85°C and 25°C to –40°C 100 Reference Voltage Long-Term Drift VREF2 VREG 10V < V+ < 50V, No Load ILOAD = 4mA Regulator Pin Short-Circuit Limit IB IS IQS ISD IOW Input Bias Current Supply Current, Measure Mode (Note 7) Supply Current, Standby ppm 60 2nd Reference Voltage Regulator Pin Voltage ppm/°C l 2.5 2.5 2.75 2.9 V V l l 4.5 4.5 5.0 5.0 5.5 V V l 8 In/Out of Pins C1 Through C12 When Measuring Cell When Not Measuring Cell Current Into the V+ Pin When Measuring Continuous Measuring (CDC = 2) Continuous Measuring (CDC = 2) Measure Every 130ms (CDC = 5) Measure Every 500ms (CDC = 6) Measure Every 2 Seconds (CDC = 7) Current Into V+ Pin When In Standby, All Serial Port Pin at Logic “1” LTC6803IG LTC6803HG Supply Current, Hardware Shutdown Current Out of V–, VC12 = 43.2V, V+ Floating (Note 8) Discharge Switch-On Resistance VCELL > 3V (Note 3) Current Used for Open-Wire Detection ppm/√kHr 2.25 2.1 –10 l l l l l l mA 1 10 µA nA 620 600 190 140 55 780 780 250 175 70 1000 1150 360 250 105 µA µA µA µA µA 8 12 16.5 µA 6 6 12 12 18 19 µA µA 0.001 1 µA 20 Ω 140 µA l l 10 l 70 Thermal Shutdown Temperature Thermal Shutdown Hysteresis 110 145 °C 5 °C Voltage Mode Timing Specifications tCYCLE Measurement Cycling t1 SDI Valid to SCKI Rising Setup l 10 ns t2 SDI Valid to SCKI Rising Hold l 250 ns t3 SCKI Low l 400 ns t4 SCKI High l 400 ns t5 CSBI Pulse Width l 400 ns t6 CSBI Falling to SCKI Rising l 100 ns t7 CSBI Falling to SDO Valid l 100 ns t8 SCKI Falling to SDO Valid l 250 Clock Frequency l 1 Watchdog Timer Timeout Period l Time Required to Measure 12 Cells Time Required to Measure 10 Cells Time Required to Measure 3 Temperatures Time Required to Measure 1 Cell or Temperature l l l l 11 9 2.8 1.0 1 13 11 3.4 1.2 15 13 4.1 1.4 2.5 ms ms ms ms ns MHz Seconds 680324f 4 LTC6803-2/LTC6803-4 ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the full operating + – temperature range, otherwise specifications are at TA = 25°C. V = 43.2V, V = 0V, unless otherwise noted. SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS Voltage Mode Digital I/O VIH Digital Input Voltage High Pins SCKI, SDI and CSBI l VIL Digital Input Voltage Low Pins SCKI, SDI and CSBI l 0.8 VOL Digital Output Voltage Low Pin SDO, Sinking 500µA l 0.3 V IIN Digital Input Current VMODE, TOS, SCKI, SDI, CSBI l 10 µA Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The ADC specifications are guaranteed by the Total Measurement Error (VERR) specification. Note 3: Due to the contact resistance of the production tester, this specification is tested to relaxed limits. The 20Ω limit is guaranteed by design. Note 4: VCELL refers to the voltage applied across Cn to Cn – 1 for n = 1 to 12. VTEMP refers to the voltage applied from VTEMP1 or VTEMP2 to V–. 2 V V Note 5: These absolute maximum ratings apply provided that the voltage between inputs do not exceed the absolute maximum ratings. Note 6: Supply current is tested during continuous measuring. The supply current during periodic measuring (130ms, 500ms, 2s) is guaranteed by design. Note 7: The CDC = 5, 6 and 7 supply currents are not measured. They are guaranteed by the CDC = 2 supply current measurement. Note 8: Limit is determined by high speed automated test capability. TYPICAL PERFORMANCE CHARACTERISTICS Cell Measurement Error vs Cell Input Voltage 0 1.5 0 –1.5 –3.0 –4.5 0 –5 –10 C = 0µF C = 0.1µF C = 1µF C = 3.3µF CELL 1, 13ms CELL MEASUREMENT REPETITION VCELL = 3.3V –15 –20 –25 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 CELL INPUT VOLTAGE (V) 680324 G01 CELL VOLTAGE ERROR (mV) 3.0 Cell Measurement Error vs Input RC Values 5 TA = 125°C TA = 85°C TA = 25°C TA = –40°C CELL VOLTAGE ERROR (mV) TOTAL UNADJUSTED ERROR (mV) 4.5 Cell Measurement Error vs Input RC Values –30 0 1 2 3 7 8 4 5 6 INPUT RESISTANCE (kΩ) 9 10 680324 G02 CELLS 2 TO 12, 13ms CELL MEASUREMENT REPETITION VCELL = 3.3V –5 –10 –15 –20 C = 0µF C = 0.1µF C = 1µF C = 3.3µF –25 –30 0 1 2 3 7 8 4 5 6 INPUT RESISTANCE (kΩ) 9 10 680324 G03 680324f 5 LTC6803-2/LTC6803-4 TYPICAL PERFORMANCE CHARACTERISTICS Cell Voltage Measurement Error vs Common Mode Voltage 10 1 0.1 –0.8 –0.6 –0.4 –0.2 0 0.2 0.4 0.6 0.8 1.0 V+ – VC12 (V) 0 –2 –4 –6 –8 VCELL = 3.6V TA = 25°C CELL2 ERROR vs VC1 CELL3 ERROR vs VC2 CELLn ERROR VS VCn–1, n = 4 TO 12 –10 –12 –14 0 1 2 4 3 COMMON MODE VOLTAGE (V) 680324 G05 Cell 1 Voltage Measurement Error vs Temperature Cell 2 Voltage Measurement Error vs Temperature 0.25 –0.50 –1.25 –2.00 –50 –30 –10 10 30 50 70 90 110 130 TEMPERATURE (°C) 2.50 CELL MEASUREMENT ERROR (mV) VCELL = 0.8V V+ = 9.6V 4 SAMPLES VCELL = 0.8V V+ = 9.6V 4 SAMPLES 1.75 1.00 0.25 –0.50 –1.25 –2.00 –50 –30 –10 10 30 50 70 90 110 130 TEMPERATURE (°C) Measurement Gain Error Hysteresis 20 TA = 85°C TO 25°C 18 1 0.1 –1.0 –0.8 –0.6 –0.4 –0.2 0 0.2 0.4 0.6 0.8 1.0 VIN CELL6 (V) Cell 3 to Cell 12 Voltage Measurement Error vs Temperature 1.75 1.00 0.25 –0.50 –1.25 680324 G09 Cell Measurement Common Mode Rejection 0 TA = –45°C TO 25°C VCM(IN) = 5VP-P 72dB REJECTION –10 CORRESPONDS TO LESS THAN 1 BIT –20 AT ADC OUTPUT NUMBER OF UNITS 14 12 10 8 6 680324 G10 –40 –60 2 0 –250 –200 –150 –100 –50 0 50 100 150 200 CHANGE IN GAIN ERROR (ppm) –30 –50 4 5 VCELL = 0.8V V+ = 9.6V 4 SAMPLES –2.00 –50 –30 –10 10 30 50 70 90 110 130 TEMPERATURE (°C) 16 10 CELL6 10 Measurement Gain Error Hysteresis 20 NUMBER OF UNITS 100 680324 G08 680324 G07 15 ALL OTHER CELLS = 3V 680324 G06 REJECTION (dB) 1.00 25 5 680324 G04 1.75 CELL MEASUREMENT ERROR (mV) 1000 2 CELL VOLTAGE MEASUREMENT ERROR (mV) TA = 25°C VCELL = 3.3V CELL MEASUREMENT ERROR (mV) CELL 12 MEASUREMENT ERROR (mV) 100 Cell Measurement Error vs Cell Voltage CELL MEASUREMENT ERROR (mV) Cell 12 Measurement Error vs V+ 0 –250 –200 –150 –100 –50 0 50 100 150 200 CHANGE IN GAIN ERROR (ppm) 680324 G11 –70 10 100 1k 10k 100k FREQUENCY (Hz) 1M 10M 680324 G12 680324f 6 LTC6803-2/LTC6803-4 TYPICAL PERFORMANCE CHARACTERISTICS ADC Normal Mode Rejection vs Frequency ADC INL 2.0 1.0 –10 1.5 0.8 0.6 1.0 –30 –40 –50 0.4 0.5 DNL (BITS) INL (BITS) –20 0 –0.5 –60 –1.5 –70 –2.0 10 100 1k 10k FREQUENCY (Hz) 100k –0.8 1 0 2 3 INPUT (V) 4 850 16 40 30 25 20 15 C12 10 10 8 6 4 C6 5 0 20 40 60 80 100 120 TEMPERATURE (°C) 10 0 20 40 30 SUPPLY VOLTAGE (V) CDC = 2 CONTINUOUS CONVERSION 4.5 10 SAMPLES 10 5 0 –5 –10 0 25 60 7000 125°C 85°C 25°C –40°C 650 600 0 10 20 40 30 SUPPLY VOLTAGE (V) 50 75 100 TEMPERATURE (°C) 50 60 680324 G18 External Temperature Measurement Total Unadjusted Error vs Input Internal Die Temperature Measurement Error Using an 8mV/°K Scale Factor 15 50 750 680324 G17 680324 G16 TOTAL UNADJUSTED ERROR (mV) 0 125°C 85°C 25°C –40°C 2 C1 5 4 800 12 SUPPLY CURRENT (µA) 35 3 2 INPUT (V) 1 Supply Current vs Supply Voltage During Continuous Conversions 14 E = (AMBIENT TEMP-INTERNAL DIE TEMP READING) (°C) CELL INPUT BIAS CURRENT (nA) 0 680324 G15 Standby Supply Current vs Supply Voltage CELL INPUT = 3.6V 0 –40 –20 –1.0 5 680324 G14 Cell Input Bias Current During Standby and Hardware Shutdown 50 0 –0.2 –0.6 680324 G13 45 0.2 –0.4 –1.0 SUPPLY CURRENT (µA) REJECTION (dB) ADC DNL 0 125 150 680324 G19 3.0 TA = 125°C TA = 85°C TA = 25°C TA = –40°C 1.5 0 –1.5 –3.0 –4.5 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 TEMPERATURE INPUT VOLTAGE (V) 680324 G20 680324f 7 LTC6803-2/LTC6803-4 TYPICAL PERFORMANCE CHARACTERISTICS VREF Output Voltage vs Temperature VREF Line Regulation VREF Load Regulation 3.070 3.09 3.068 3.074 3.072 3.08 3.070 3.062 3.07 TA = 85°C TA = 25°C 3.06 3.060 3.05 5 REPRESENTATIVE UNITS –25 25 75 0 50 TEMPERATURE (°C) 100 125 3.04 0 3.060 1000 10 100 SOURCING CURRENT (µA) 5.5 V+ = 43.2V 4.8 50 VREG (V) 4.5 0 2 4 6 8 SUPPLY CURRENT (mA) 10 12 4.0 TA = 125°C TA = 85°C TA = 25°C TA = –40°C 0 10 60 TA = 105°C TA = 85°C TA = 25°C TA = –45°C 45 5.0 4.2 50 Internal Discharge Resistance vs Cell Voltage CDC = 2 CONTINUOUS CONVERSIONS 5.0 TA = 125°C TA = 85°C TA = 25°C TA = –40°C 20 30 40 SUPPLY VOLTAGE (V) 680324 G23 VREG Line Regulation 4.4 10 0 680324 G22 VREG Load Regulation 4.6 TA = –40°C 3.062 680324 G21 5.2 TA = 85°C 3.066 DISCHARGE RESISTANCE (Ω) 3.056 –50 TA = 25°C 3.068 3.064 TA = –40°C 3.058 VREG (V) VREF (V) 3.064 VREF (V) VREF (V) 3.066 4.0 NO EXTERNAL LOAD ON VREF, CDC = 2 (CONTINUOUS CELL CONVERSIONS) 20 30 40 SUPPLY VOLTAGE (V) 50 40 35 30 25 20 15 10 5 0 60 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 CELL VOLTAGE (V) 680324 G26 680324 G24 680324 G25 Die Temperature Increase vs Discharge Current in Internal FET Cell Conversion Time 13.20 ALL 12 CELLS AT 3.6V 45 VS = 43.2V TA = 25°C 40 13.15 35 30 12 CELLS DISCHARGING 25 20 15 6 CELLS DISCHARGING 1 CELL DISCHARGING 10 13.10 13.05 13.00 12.95 12.90 12.85 5 0 CONVERSION TIME (ms) INCREASE IN DIE TEMPERATURE (°C) 50 0 10 20 30 40 50 60 70 80 DISCHARGE CURRENT PER CELL (mA) 680324 G27 12.80 –40 –20 0 20 40 60 80 TEMPERATURE (°C) 100 120 680324 G28 680324f 8 LTC6803-2/LTC6803-4 PIN FUNCTIONS To ensure pin compatibility with LTC6802-2, the LTC6803‑2 is configured such that the bottom cell input (C0) is connected internally to the negative supply voltage (V–). The LTC6803-4 offers a unique pinout with an input for the bottom cell (C0). This simple functional difference offers the possibility for enhanced cell 1 measurement accuracy, enhanced SPI noise tolerance and simplified wiring. More information is provided in the Applications Information section entitled Advantages of Kelvin Connection for C0. V+ (Pin 1): Positive Power Supply. Pin 1 can be tied to the most positive potential in the battery stack or an isolated power supply. V+ must be greater than the most positive potential in the battery stack under normal operation. With an isolated power supply, LTC6803 can be turned off by simply shutting down V+. C12, C11, C10, C9, C8, C7, C6, C5, C4, C3, C2, C1 (Pins 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24): C1 through C12 are the inputs for monitoring battery cell voltages. The negative terminal of the bottom cell should be tied to the V– pin for the LTC6803-2, and the C0 pin for the LTC6803-4. The next lowest potential is tied to C1 and so forth. See the figures in the Applications Information section for more details on connecting batteries to the LTC6803-2 and LTC6803-4. The LTC6803 can monitor a series connection of up to 12 cells. Each cell in a series connection must have a common mode voltage that is greater than or equal to the cells below it. 100mV negative voltages are permitted. C0 (Pin 26 on LTC6803-4): Negative Terminal of the Bottom Battery Cell. C0 and V– form a Kelvin connection to eliminate effect of voltage drop at the V– trace. S12, S11, S10, S9, S8, S7, S6, S5, S4, S3, S2, S1 (Pins 3, 5, 7, 9, 11, 13, 15, 17, 19, 21, 23, 25): S1 though S12 pins are used to balance battery cells. If one cell in a series becomes overcharged, an S output can be used to discharge the cell. Each S output has an internal N-channel MOSFET for discharging. See the Block Diagram. The NMOS has a maximum on-resistance of 20Ω. An external resistor should be connected in series with the NMOS to dissipate heat outside of the LTC6803 package. When using the internal MOSFETs to discharge cells, the die temperature should be monitored. See Power Dissipation and Thermal Shutdown in the Applications Information section. The S pins also feature an internal pull-up PMOS. This allows the S pins to be used to drive the gates of external MOSFETs for higher discharge capability. V– (Pin 26 on LTC6803-2/Pin 27 on LTC6803-4): Connect V– to the most negative potential in the series of cells. NC (Pin 27 on LTC6803-2/Pin 28 on LTC6803-4): This pin is not used and is internally connected to V– through 10Ω. It can be left unconnected or connected to V– on the PCB. VTEMP1, VTEMP2 (Pins 28, 29 on LTC6803-2/Pins 29, 30, on LTC6803-4): Temperature Sensor Inputs. The ADC will measure the voltage on VTEMPn with respect to V– and store the result in the TMP register. The ADC measurements are relative to the VREF pin voltage. Therefore a simple thermistor and resistor combination connected to the VREF pin can be used to monitor temperature. The VTEMP inputs can also be general purpose ADC inputs. VREF (Pin 30 on LTC6803-2/Pin 31 on LTC6803-4): 3.065V Voltage Reference Output. This pin should be bypassed with a 1µF capacitor. The VREF pin can drive a 100k resistive load connected to V–. Larger loads should be buffered with an LT6003 op amp, or a similar device. VREG (Pin 31 on LTC6803-2/Pin 32 on LTC6803-4): Linear Voltage Regulator Output. This pin should be bypassed with a 1µF capacitor. The VREG is capable of sourcing up to 4mA to an external load. The VREG pin does not sink current. TOS (Pin 32 on LTC6803-2/Pin 33 on LTC6803-4): Top of Stack Input. The TOS pin can be tied to VREG or V– for the LTC6803. The state of the TOS pin alters the operation of the SDO pin in the toggle polling mode. See the Serial Port description. NC (Pin 33 on LTC6803-2): No Connection. 680324f 9 LTC6803-2/LTC6803-4 PIN FUNCTIONS WDTB (Pin 34): Watchdog Timer Output (Active Low). If there is no valid command received in 1 to 2.5 seconds, the WDTB output is asserted. The WDTB pin is an open-drain NMOS output. When asserted it pulls the output down to V– and resets the configuration register to its default state. A0, A1, A2, A3 (Pins 37, 38, 39, 40): Address Inputs. These pins are tied to VREG or V–. The state of the address pins (VREG = 1, V– = 0) determines the LTC6803 address. See Address Commands in the Serial Port subsection of the Applications Information section. GPIO1, GPIO2 (Pins 35, 36): General Purpose Input/ Output. By writing a “0” to a GPIO configuration register bit, the open-drain output is activated and the pin is pulled to V–. By writing a logic “1” to the configuration register bit, the corresponding GPIO pin is high impedance. An external resistor is required to pull the pin up to VREG. By reading the configuration register locations GPIO1 and GPIO2, the state of the pins can be determined. For example, if a “0” is written to register bit GPIO1, a “0” is always read back because the output N-channel MOSFET pulls Pin 35 to V–. If a “1” is written to register bit GPIO1, the pin becomes high impedance. Either a “1” or a “0” is read back, depending on the voltage present at Pin 35. The GPIOs makes it possible to turn-on/off circuitry around the LTC6803-4, or read logic values from a circuit around the LTC6803-4. The GPIO pins should be connected to V– if not used. SCKI (Pin 41): Serial Clock Input. The SCKI pin interfaces to any logic gate (TTL levels). See Serial Port in the Applications Information section. SDI (Pin 42): Serial Data Input. The SDI pin interfaces to any logic gate (TTL levels). See Serial Port in the Applications Information section. SDO (Pin 43): Serial Data Output. The SDO pin is an NMOS open-drain output. A pull-up resistor is needed on SDO. See Serial Port in the Applications Information section. CSBI (Pin 44): Chip Select (Active Low) Input. The CSBI pin interfaces to any logic gate (TTL levels). See Serial Port in the Applications Information section. 680324f 10 LTC6803-2/LTC6803-4 BLOCK DIAGRAMS 1 LTC6803-2 V+ 2nd REFERENCE 2 3 4 REGULATOR VREF2 C12 S12 WATCHDOG TIMER VREG WDTB 22 23 24 34 C11 A3 A2 21 31 A1 S3 ∆Σ A/D CONVERTER MUX C2 12 RESULTS REGISTER AND COMMUNICATIONS S2 A0 CSBI SDO SDI SCKI C1 40 39 38 37 44 43 42 41 REFERENCE 25 26 S1 GPIO2 V– CONTROL EXTERNAL TEMP DIE TEMP NC 27 VTEMP1 28 VTEMP2 29 GPIO1 TOS 39 38 32 VREF 30 68032 BD 680324f 11 LTC6803-2/LTC6803-4 BLOCK DIAGRAMS 1 LTC6803-4 V+ 2nd REFERENCE 2 3 4 REGULATOR VREF2 C12 S12 WATCHDOG TIMER VREG WDTB 22 23 24 A3 A1 S3 MUX C2 12 ∆Σ A/D CONVERTER RESULTS REGISTER AND COMMUNICATIONS S2 26 27 A0 CSBI SDO SDI C1 SCKI REFERENCE 25 34 C11 A2 21 32 GPIO2 S1 C0 CONTROL V – EXTERNAL TEMP DIE TEMP VTEMP1 NC 28 29 GPIO1 TOS VTEMP2 40 39 38 37 44 43 42 41 36 35 33 VREF 30 31 68033 BD TIMING DIAGRAM Timing Diagram of the Serial Interface t1 t4 t2 t6 t3 t7 SCKI D3 SDI D2 D1 D0 D7···D4 D3 t5 CSBI t8 SDO D4 D3 PREVIOUS COMMAND D2 D1 D0 D7···D4 CURRENT COMMAND D3 68034 TD 680324f 12 LTC6803-2/LTC6803-4 OPERATION THEORY OF OPERATION The LTC6803 is a data acquisition IC capable of measuring the voltage of 12 series connected battery cells. An input multiplexer connects the batteries to a 12-bit delta-sigma analog-to-digital converter (ADC). An internal 8ppm/°C voltage reference combined with the ADC give the LTC6803 its outstanding measurement accuracy. The inherent benefits of the delta-sigma ADC versus other types of ADCs (e.g., successive approximation) are explained in Advantages of Delta-Sigma ADCs in the Applications Information section. Communication between the LTC6803 and a host processor is handled by a SPI compatible serial interface. Multiple LTC6803s can be connected to a single serial interface. As shown in Figure 1, the LTC6803-2s or LTC6803-4s are isolated from one another using digital isolators. A unique addressing scheme allows all the LTC6803-2s or LTC6803‑4s to connect to the same serial port of the host processor. Further explanation of the LTC6803-2/LTC68034 can be found in the Serial Port section of the data sheet. The LTC6803 also contains circuitry to balance cell voltages. Internal MOSFETs can be used to discharge cells. These internal MOSFETs can also be used to control external balancing circuits. Figure 1 illustrates cell balancing by internal discharge. Figure 3 shows the S pin controlling an external balancing circuit. It is important to note that the LTC6803 makes no decisions about turning on/off the internal MOSFETs. This is completely controlled by the host processor. The host processor writes values to a configuration register inside the LTC6803 to control the switches. The watchdog timer on the LTC6803 can be used to turn off the discharge switches if communication with the host processor is interrupted. Since the LTC6803-4 separates C0 and V–, C0 can have higher potential than V–. This feature is very useful for super capacitors and fuel cells whose voltages can go to zero or slightly negative. In such a case, the stacked cells can’t power the LTC6803-4. In Figure 1, an isolated 36V and –3.6V provides power to each LTC6803-4. This allows the C1 to C12 pins to go up to 3.6V below C0. The LTC6803 has three modes of operation: hardware shutdown, standby and measure. Hardware shutdown is a true zero power mode. Standby mode is a power saving state where all circuits except the serial interface are turned off. In measure mode, the LTC6803 is used to measure cell voltages and store the results in memory. Measure mode will also monitor each cell voltage for overvoltage (OV) and undervoltage (UV) conditions. HARDWARE SHUTDOWN MODE The V+ pin can be disconnected from the C pins and the battery pack. If the V+ supply pin is 0V, the LTC6803 will typically draw less than 1nA from the battery cells. All circuits inside the IC are off. It is not possible to communicate with the IC when V+ = 0V. See the Applications Information section for hardware shutdown circuits. STANDBY MODE The LTC6803 defaults (powers up) to standby mode. Standby mode is the lowest supply current state with a supply connected. Standby current is typically 12µA when V+ = 44V. All circuits are turned off except the serial interface and the voltage regulator. For the lowest possible standby current consumption, all SPI logic inputs should be set to logic 1 level. The LTC6803 can be programmed for standby mode by setting the comparator duty cycle configuration bits, CDC[2:0], to 0. If the part is put into standby mode while ADC measurements are in progress, the measurements will be interrupted and the cell voltage registers will be in an indeterminate state. To exit standby mode, the CDC bits must be written to a value other than 0. MEASURE MODE The LTC6803 is in measure mode when the CDC bits are programmed with a value from 1 to 7. When CDC = 1 the LTC6803 is on and waiting for a start ADC conversion command. When CDC is 2 through 7 the IC monitors each cell voltage and produces an interrupt signal on the SDO pin indicating all cell voltages are within the UV and OV limits. The value of the CDC bits determines how often the cells are monitored, and, how much average supply current is consumed. 680324f 13 LTC6803-2/LTC6803-4 OPERATION LTC6803-4 IC #1 CSBI V SDO C12 SDI S12 SCKI C11 A3 S11 A2 C10 A1 S10 A0 C9 GPIO2 S9 GPIO1 C8 WDTB S8 TOS C7 VREG S7 C6 VREF S6 VTEMP2 C5 VTEMP1 V2 – OE2 + + + + + + + + + + + S5 C4 S4 C3 S3 C2 V1– OE1 LTC6803-4 IC #7 CSBI V SDO C12 SDI S12 SCKI C11 A3 S11 A2 C10 A1 S10 A0 C9 GPIO2 S9 GPIO1 C8 WDTB S8 TOS C7 VREG S7 C6 VREF S6 VTEMP2 C5 VTEMP1 + ADDRESS1 V2 – V1– V2 + V1+ DIGITAL ISOLATOR + 3V + + + + + + NC V– C0 S1 C1 S2 ISOLATED DC/DC CONVERTER V2 – OE2 + 12V S5 C4 S4 C3 S3 C2 + + + + NC V– C0 S1 C1 S2 ADDRESS7 V1– OE1 V2 – V1– V2 + V1+ DIGITAL ISOLATOR ISOLATED DC/DC CONVERTER 3V 12V 680324 F01 + 3V + + + + + + + + + + + LTC6803-4 IC #0 CSBI V+ SDO C12 SDI S12 SCKI C11 A3 S11 A2 C10 A1 S10 A0 C9 GPIO2 S9 GPIO1 C8 WDTB S8 TOS C7 VREG S7 C6 VREF S6 VTEMP2 C5 VTEMP1 S5 C4 S4 C3 S3 C2 NC V– C0 S1 C1 S2 V2 – OE2 V1– OE1 – – MPU MISO CS MODULE IO M0SI ADDRESS0 V2 V1 V2 + V1+ DIGITAL ISOLATOR ISOLATED DC/DC CONVERTER CLK 3V 12V + Figure 1. Simplified 96-Cell Battery or Supercapacitor, Isolated Interface. In this Diagram the Battery Negative is Isolated from the Module Ground. Isolated Power Supplies Each LTC6803-4. Opto-Couplers or Digital Isolators Allow Each IC to Be Addressed Individually 680324f 14 LTC6803-2/LTC6803-4 OPERATION There are two methods for indicating the UV/OV interrupt status: toggle polling (using a 1kHz output signal) and level polling (using a high or low output signal). The polling methods are described in the Serial Port section. The UV/OV limits are set by the VUV and VOV values in the configuration registers. When a cell voltage exceeds the UV/OV limits a bit is set in the flag register. The UV and OV flag status for each cell can be determined using the Read Flag Register Group. absolute ADC measurement range is –0.768V to 5.376V. The resolution is VLSB = 1.5mV = (5.376 + 0.768)/212. The useful range is –0.3V to 5V. This range allows monitoring supercapacitors which could have small negative voltage. Inputs below –0.3V exceed the absolute maximum rating of the C pins. If all inputs are negative, the ADC range is reduced to –0.1V. Inputs above 5V will have noisy ADC readings (see Typical Performance Characteristics). An ADC measurement can be requested at any time when the IC is in measure mode. To initiate cell voltage measurements while in measure mode, a Start A/D Conversion command is sent. After the command has been sent, the LTC6803 will indicate the A/D converter status via toggle polling or level polling (as described in the Serial Port section). During cell voltage measurement commands, the UV and OV flags (within the flag register group) are also updated. When the measurements are complete, the part will continue monitoring UV and OV conditions at the rate designated by the CDC bits. ADC MEASUREMENTS DURING CELL BALANCING Operating with Less than 12 Cells If fewer than 12 cells are connected to the LTC6803, the unused input channels must be masked. The MCxI bits in the configuration registers are used to mask channels. In addition, the LTC6803 can be configured to automatically bypass the measurements of the top 2 cells, reducing power consumption and measurement time. If the CELL10 bit is high, the inputs for cell 11 and cell 12 are masked and only the bottom 10-cell voltages will be measured. By default, the CELL10 bit is low, enabling measurement of all 12-cell voltages. Additional information regarding operation with less than 12 cells is provided in the applications section. ADC RANGE AND OUTPUT FORMAT The ADC outputs a 12-bit code with an offset of 0x200 (512 decimal). The input voltage can be calculated as: VIN = (DOUT – 512) • VLSB; VLSB = 1.5mV where DOUT is a decimal integer. The primary cell voltage ADC measurement commands (STCVAD and STOWAD) automatically turn off a cell’s discharge switch while its voltage is being measured. The discharge switches for the cell above and the cell below will also be turned off during the measurement. For example, discharge switches S4, S5 and S6 will be off while cell 5 is being measured. In some systems it may be desirable to allow discharging to continue during cell voltage measurements. The cell voltage ADC conversion commands STCVDC and STOWDC allow the discharge switches to remain on during cell voltage measurements. This feature allows the system to perform a self test to verify the discharge functionality. All discharge switches are automatically disabled during OV and UV comparison measurements. ADC REGISTER CLEAR COMMAND The clear command can be used to clear the cell voltage registers and temperature registers. The clear command will set all registers to 0xFFF. This command is used to make sure conversions are being made. When cell voltages are stable, ADC results could stay the same. If a start ADC conversion command is sent to the LTC6803 but the PEC fails to match then the command is ignored and the voltage register contents also will not change. Sending a clear command then reading back register contents is a way to make sure LTC6803 is accepting commands and performing new measurements. The clear command takes 1ms to execute. For example, a 0V input will have an output reading of 0x200. An ADC reading of 0x000 means the input was –0.768V. The 680324f 15 LTC6803-2/LTC6803-4 OPERATION ADC CONVERTER SELF TEST Two self-test commands can be used to verify the functionality of the digital portions of the ADC. The self tests also verify the cell voltage registers and temperature monitoring registers. During these self tests a test signal is applied to the ADC. If the circuitry is working properly all cell voltage and temperature registers will contain 0x555 or 0xAAA. The time required for the self-test function is the same as required to measure all cell voltages or all temperature sensors. MULTIPLEXER AND REFERENCE SELF TEST The LTC6803 uses a multiplexer to measure the 12 battery cell inputs as well as the temperature signals. A diagnostic command is used to validate the function of the multiplexer, the temperature sensor, and the precision reference circuit. Diagnostic registers will be updated after each diagnostic test. The muxfail bit of the registers will be 1 if the multiplexer self test fails. A constant voltage generated by the 2nd reference circuit will be measured by the ADC and the results written to the diagnostic register. The voltage reading should be 2.5V ±16%. Readings outside this range indicate a failure of the temperature sensor circuit, the precision reference circuit, or the analog portion of the ADC. The DAGN command executes in 16.4ms, which is the sum of the 12-cell tCYCLE and the 3 temperature tCYCLE. The diagnostic read command can be used to read the registers. USING THE GENERAL PURPOSE INPUTS/OUTPUTS (GPIO1, GPIO2) The LTC6803 has two general purpose digital input/output pins. By writing a GPIO configuration register bit to a logic low, the open-drain output can be activated. The GPIOs give the user the ability to turn on/off circuitry around the LTC6803. One example might be a circuit to verify the operation of the system. When a GPIO configuration bit is written to a logic high, the corresponding GPIO pin may be used as an input. The read back value of that bit will be the logic level that appears at the GPIO pins. WATCHDOG TIMER CIRCUIT The LTC6803 includes a watchdog timer circuit. The watchdog timer is on for all modes except CDC = 0. The watchdog timer times out if no valid command is received for 1 to 2.5 seconds. When the watchdog timer circuit times out, the WDTB open-drain output is asserted low and the configuration register bits are reset to their default (power-up) state. In the power-up state, CDC is 0, the S outputs are off and the IC is in the low power standby mode. The WDTB pin remains low until a valid command is received. The watchdog timer provides a means to turn off cell discharging should communications to the MPU be interrupted. There is no need for the watchdog timer at CDC = 0 since discharging is off. The open-drain WDTB output can be wire ORd with other external open-drain signals. Pulling the WDTB signal low will not initiate a watchdog event, but the CNFGO bit 7 will reflect the state of this signal. Therefore, the WDTB pin can be used to monitor external digital events if desired. SERIAL PORT Overview The LTC6803-2/LTC6803-4 has an SPI bus compatible serial port. Devices can be connected in parallel, using digital isolators. Multiple devices are uniquely identified by a part address determined by the A0 to A3 pins. Physical Layer on the LTC6803-2/LTC6803-4, four pins comprise the serial interface: CSBI, SCKI, SDI and SDO. The SDO and SDI may be tied together, if desired, to form a single, bi-directional port. Four address pins (A0 to A3) set the part address for address commands. The TOS pin designates the top device (logic high) for polling commands. All interface pins are voltage mode, with voltage levels sensed with respect to the V– supply. See Figure 1. 680324f 16 LTC6803-2/LTC6803-4 OPERATION Data Link Layer Network Layer Clock Phase And Polarity: The LTC6803 SPI compatible interface is configured to operate in a system using CPHA = 1 and CPOL = 1. Consequently, data on SDI must be stable during the rising edge of SCKI. PEC Byte: The packet error code (PEC) byte is a cyclic redundancy check (CRC) value calculated for all of the bits in a register group in the order they are passed, using the initial PEC value of 01000001 and the following characteristic polynomial: Data Transfers: Every byte consists of 8 bits. Bytes are transferred with the most significant bit (MSB) first. On a write, the data value on SDI is latched into the device on the rising edge of SCKI (Figure 2). Similarly, on a read, the data value output on SDO is valid during the rising edge of SCKI and transitions on the falling edge of SCKI (Figure 3). CSBI must remain low for the entire duration of a command sequence, including between a command byte and subsequent data. On a write command, data is latched in on the rising edge of CSBI. x8 + x2 + x + 1 To calculate the 8-bit PEC value, a simple procedure can be established: 1. Initialize the PEC to 0100 0001. 2. For each bit DIN coming into the register group, set IN0 = DIN XOR PEC[7], then IN1 = PEC[0] XOR IN0, IN2 = PEC[1] XOR IN0. 3. Update the 8-bit PEC as PEC[7] = PEC[6], PEC[6] = PEC[5],……PEC[3] = PEC[2], PEC[2] = IN2, PEC[1] = IN1, PEC[0] = IN0. 4. Go back to step 2 until all data are shifted. The 8-bit result is the final PEC byte. CSBI SCKI SDI MSB (CMD) BIT 6 (CMD) LSB (CMD) MSB (DATA) LSB (DATA) 68034 F02 Figure 2. Transmission Format (Write) CSBI SCKI SDI SDO MSB (CMD) BIT 6 (CMD) LSB (CMD) MSB (DATA) LSB (DATA) 68034 F03 Figure 3. Transmission Format (Read) 680324f 17 LTC6803-2/LTC6803-4 OPERATION An example to calculate the PEC is listed in Table 1 and Figure 4. The PEC of the 1 byte data 0x01 is computed as 0xC7 after the last bit of the byte streamed in. For multiple byte data, PEC is valid at the end (LSB) of the last byte. value of 1000 and 4 address bits. Following the address command is its PEC byte. The third and fourth bytes are the command byte and its PEC byte respectively. See the Bus Protocols and Commands section. LTC6803 calculates PEC byte for any command or data received and compares it with the PEC byte following the command or data. The command or data is regarded as valid only if the PEC bytes match. LTC6803 also attaches the calculated PEC byte at the end of the data it shifts out. Polling Methods: For ADC conversions, three methods can be used to determine ADC completion. First, a controller can start an ADC conversion and wait for the specified conversion time to pass before reading the results. The second method is to hold CSBI low after an ADC start command has been sent. The ADC conversion status will be output on SDO (Figure 5). A problem with the second method is that the controller is not free to do other serial communication while waiting for ADC conversions to complete. The third method overcomes this limitation. The controller can send an ADC start command, perform other tasks, and then send a poll ADC converter status (PLADC) command to determine the status of the ADC conversions (Figure 6). For OV/UV interrupt status, the poll interrupt status (PLINT) command can be used to quickly determine whether any cell in a stack is in an overvoltage or undervoltage condition (Figure 6). Broadcast Commands: A broadcast command is one to which all devices on the bus will respond, regardless of device address. See the Bus Protocols and Commands sections. With broadcast commands all devices can be sent commands simultaneously. This is useful for ADC conversion and polling commands. It can also be used with write commands when all parts are being written with the same data. Broadcast read commands should not be used in the parallel configuration. Address Commands: An address command is one in which only the addressed device on the bus responds. The first byte of an address command consists of 4 bits with a Table 1. Procedure to Calculate PEC Byte CLOCK CYCLE DIN IN0 IN1 IN2 PEC[7] PEC[6] PEC[5] PEC[4] PEC[3] PEC[2] PEC[1] PEC[0] 0 0 0 1 0 0 1 0 0 0 0 0 1 1 0 1 1 0 1 0 0 0 0 0 1 0 2 0 0 1 1 0 0 0 0 0 0 1 1 3 0 0 0 1 0 0 0 0 0 1 1 0 4 0 0 0 0 0 0 0 0 1 1 0 0 5 0 0 0 0 0 0 0 1 1 0 0 0 6 0 0 0 0 0 0 1 1 0 0 0 0 7 1 1 1 1 0 1 1 0 0 0 0 0 1 1 0 0 0 1 1 1 8 680324f 18 1 IN0 DTFF END INO = DATAIN XOR PEC[7]; PEC1 = PEC[0] XOR IN0; PEC2 = PEC[1] XOR IN0; PEC[7:0] = {PEC[6:2], PEC2, PEC1, IN0}; 2 3 4 2 1 BEGIN PEC[7:0] = 0x41 CLK Q Q PEC[0] D PEC Hardware and Software Example CLOCK BEGIN PEC[7:0] = 0x41 INO = DATAIN XOR PEC[7]; DATAIN XOR PEC[0] INO XOR PEC1 Q DTFF CLK Q D PEC[1] PEC1 = PEC[0] XOR IN0; XOR PEC2 Q PEC[2] Figure 4 DTFF CLK Q D PEC[2] PEC2 = PEC[1] XOR IN0; PEC[1] IN0 3 DTFF CLK Q Q PEC[3] D PEC[3] 4 DTFF CLK Q Q DTFF CLK Q D PEC[5] PEC[5] Q DTFF CLK Q D PEC[6] PEC[7:0] = {PEC[6:2], PEC2, PEC1, IN0}; END PEC[4] PEC[4] D Q PEC[6] Q 680324 F04 DTFF CLK Q D PEC[7] PEC[7] OPERATION PEC[7] LTC6803-2/LTC6803-4 680324f 19 LTC6803-2/LTC6803-4 OPERATION tCYCLE CSBI SCKI SDI MSB (CMD) BIT6 (CMD) LSB (PEC) SDO TOGGLE OR LEVEL POLL 680324 F05 Figure 5. Transmission Format (ADC Conversion and Poll) CSBI SCKI SDI MSB (CMD) BIT6 (CMD) SDO LSB (PEC) TOGGLE OR LEVEL POLL 680324 F06 Figure 6. Transmission Format (PLADC Conversion or PLINT) Toggle Polling: Toggle polling allows a robust determination both of device states and of the integrity of the connections between the devices in a stack. Toggle polling is enabled when the LVLPL bit is low. After entering a polling command, the data out line will be driven by the slave devices based on their status. When polling for the ADC converter status, data out will be low when any device is busy performing an ADC conversion and will toggle at 1kHz when no device is busy. Similarly, when polling for interrupt status, the output will be low when any device has an interrupt condition and will toggle at 1kHz when none has an interrupt condition. Level Polling: Level polling is enabled when the LVLPL bit is high. After entering a polling command, the data out line will be driven by the slave devices based on their status. When polling for the ADC converter status, data out will be low when any device is busy performing an ADC conversion and will be high when no device is busy. Similarly, when polling for interrupt status, the output will be low when any device has an interrupt condition and will be high when none has an interrupt condition. Toggle Polling—Address Polling: The addressed device drives the SDO line based on its state alone—low for busy/ in interrupt, toggling at 1kHz for not busy/not in interrupt. Level polling—Parallel Broadcast Polling: No part address is sent, so all devices respond simultaneously. If a device is busy/in interrupt, it will pull SDO low. If a device is not busy/not in interrupt, then it will release the SDO line. If any device is busy or in interrupt the SDO signal will be low. If all devices are not busy/not in interrupt, the SDO signal will be high. The master controller pulls CSBI high to exit polling. Toggle Polling—Parallel Broadcast Polling: No part address is sent, so all devices respond simultaneously. If a device is busy/in interrupt, it will pull SDO low. If a device is not busy/not in interrupt, then it will release the SDO line (TOS = 0) or attempt to toggle the SDO line at 1kHz (TOS = 1).The master controller pulls CSBI high to exit polling. Level Polling—Address Polling: The addressed device drives the SDO line based on its state alone—pulled low for busy/in interrupt, released for not busy/not in interrupt. 680324f 20 LTC6803-2/LTC6803-4 OPERATION Revision Code Bus Protocols The diagnostic register group contains a 2-bit revision code. If software detection of device revision is necessary, then contact the factory for details. Otherwise, the code can be ignored. In all cases, however, the values of all bits must be used when calculating the packet error code (PEC) byte on data reads. There are 6 different protocol formats, depicted in Table 3 through Table 8. Table 2 is the key for reading the protocol diagrams. Table 2. Protocol Key PEC Packet Error Code Master-to-Slave N Number of Bits Slave-to-Master ... Continuation of Protocol Complete Byte of Data Table 3. Broadcast Poll Command 8 8 Command PEC Poll Data Table 4. Broadcast Read 8 8 8 … 8 8 Command PEC Data Byte Low … Data Byte High PEC A bus collision will occur if multiple devices are on the same serial bus. Table 5. Broadcast Write 8 8 8 … 8 8 Command PEC Data Byte Low … Data Byte High PEC Table 6. Address Poll Command 4 4 8 8 8 1000 Address PEC Command PEC Poll Data Table 7. Address Read 4 4 8 8 8 8 … 8 8 1000 Address PEC Command PEC Data Byte Low … Data Byte High PEC See Serial Command examples Table 8. Address Write 4 4 8 8 8 8 … 8 8 1000 Address PEC Command PEC Data Byte Low … Data Byte High PEC 680324f 21 LTC6803-2/LTC6803-4 OPERATION Commands Table 9. Command Codes and PEC Bytes COMMAND DESCRIPTION NAME CODE PEC Write Configuration Register Group WRCFG 01 C7 Read Configuration Register Group RDCFG 02 CE Read All Cell Voltage Group RDCV 04 DC Read Cell Voltages 1-4 RDCVA 06 D2 Read Cell Voltages 5-8 RDCVB 08 F8 Read Cell Voltages 9-12 RDCVC 0A F6 Read Flag Register Group RDFLG 0C E4 Read Temperature Register Group RDTMP 0E EA Start Cell Voltage ADC Conversions and Poll Status STCVAD All Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Cell 7 Cell 8 Cell 9 Cell 10 Cell 11 Cell 12 Clear (FF) Self Test1 Self Test2 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F B0 B7 BE B9 AC AB A2 A5 88 8F 86 81 94 93 9A 9D Start Open-Wire ADC Conversions and Poll Status STOWAD All Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Cell 7 Cell 8 Cell 9 Cell 10 Cell 11 Cell 12 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 20 27 2E 29 3C 3B 32 35 18 1F 16 11 4 Start Temperature ADC Conversions and Poll Status STTMPAD All External1 External2 Internal Self Test 1 Self Test 2 30 31 32 33 3E 3F 50 57 5E 59 7A 7D Poll ADC Converter Status PLADC 40 07 Poll Interrupt Status PLINT 50 77 Start Diagnose and Poll Status DAGN 52 79 Read Diagnostic Register RDDGNR 54 6B 680324f 22 LTC6803-2/LTC6803-4 OPERATION Table 9. Command Codes and PEC Bytes (continued) COMMAND DESCRIPTION NAME Start Cell Voltage ADC Conversions and Poll Status, with Discharge Permitted STCVDC Start Open-Wire ADC Conversions and Poll Status, with Discharge Permitted STOWDC CODE PEC All Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Cell 7 Cell 8 Cell 9 Cell 10 Cell 11 Cell 12 60 61 62 63 64 65 66 67 68 69 6A 6B 6C E7 E0 E9 EE FB FC F5 F2 DF D8 D1 D6 C3 All Cell 1 Cell 2 Cell 3 Cell 4 Cell 5 Cell 6 Cell 7 Cell 8 Cell 9 Cell 10 Cell 11 Cell 12 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 97 90 99 9E 8B 8C 85 82 AF A8 A1 A6 B3 Table 10. Configuration (CFG) Register Group REGISTER RD/WR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CFGR0 RD/WR WDT GPIO2 GPIO1 LVLPL CELL10 CDC[2] CDC[1] CDC[0] CFGR1 RD/WR DCC8 DCC7 DCC6 DCC5 DCC4 DCC3 DCC2 DCC1 CFGR2 RD/WR MC4I MC3I MC2I MC1I DCC12 DCC11 DCC10 DCC9 CFGR3 RD/WR MC12I MC11I MC10I MC9I MC8I MC7I MC6I MC5I CFGR4 RD/WR VUV[7] VUV[6] VUV[5] VUV[4] VUV[3] VUV[2] VUV[1] VUV[0] CFGR5 RD/WR VOV[7] VOV[6] VOV[5] VOV[4] VOV[3] VOV[2] VOV[1] VOV[0] 680324f 23 LTC6803-2/LTC6803-4 OPERATION Table 11. Cell Voltage (CV) Register Group REGISTER RD/WR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 CVR00 RD C1V[7] C1V[6] C1V[5] C1V[4] C1V[3] C1V[2] C1V[1] C1V[0] CVR01 RD C2V[3] C2V[2] C2V[1] C2V[0] C1V[11] C1V[10] C1V[9] C1V[8] CVR02 RD C2V[11] C2V[10] C2V[9] C2V[8] C2V[7] C2V[6] C2V[5] C2V[4] CVR03 RD C3V[7] C3V[6] C3V[5] C3V[4] C3V[3] C3V[2] C3V[1] C3V[0] CVR04 RD C4V[3] C4V[2] C4V[1] C4V[0] C3V[11] C3V[10] C3V[9] C3V[8] CVR05 RD C4V[11] C4V[10] C4V[9] C4V[8] C4V[7] C4V[6] C4V[5] C4V[4] CVR06 RD C5V[7] C5V[6] C5V[5] C5V[4] C5V[3] C5V[2] C5V[1] C5V[0] CVR07 RD C6V[3] C6V[2] C6V[1] C6V[0] C5V[11] C5V[10] C5V[9] C5V[8] CVR08 RD C6V[11] C6V[10] C6V[9] C6V[8] C6V[7] C6V[6] C6V[5] C6V[4] CVR09 RD C7V[7] C7V[6] C7V[5] C7V[4] C7V[3] C7V[2] C7V[1] C7V[0] CVR10 RD C8V[3] C8V[2] C8V[1] C8V[0] C7V[11] C7V[10] C7V[9] C7V[8] CVR11 RD C8V[11] C8V[10] C8V[9] C8V[8] C8V[7] C8V[6] C8V[5] C8V[4] CVR12 RD C9V[7] C9V[6] C9V[5] C9V[4] C9V[3] C9V[2] C9V[1] C9V[0] CVR13 RD C10V[3] C10V[2] C10V[1] C10V[0] C9V[11] C9V[10] C9V[9] C9V[8] CVR14 RD C10V[11] C10V[10] C10V[9] C10V[8] C10V[7] C10V[6] C10V[5] C10V[4] CVR15* RD C11V[7] C11V[6] C11V[5] C11V[4] C11V[3] C11V[2] C11V[1] C11V[0] CVR16* RD C12V[3] C12V[2] C12V[1] C12V[0] C11V[11] C11V[10] C11V[9] C11V[8] CVR17* RD C12V[11] C12V[10] C12V[9] C12V[8] C12V[7] C12V[6] C12V[5] C12V[4] *Registers CVR15, CVR16, and CVR17 can only be read if the CELL10 bit in register CFGR0 is low Table 12. Flag (FLG) Register Group REGISTER RD/WR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 FLGR0 RD C4OV C4UV C3OV C3UV C2OV C2UV C1OV C1UV FLGR1 RD C8OV C8UV C7OV C7UV C6OV C6UV C5OV C5UV FLGR2 RD C12OV* C12UV* C11OV* C11UV* C10OV C10UV C9OV C9UV BIT 2 BIT 1 BIT 0 * Bits C11UV, C12UV, C11OV and C12OV are always low if the CELL10 bit in register CFGR0 is high Table 13. Temperature (TMP) Register Group REGISTER RD/WR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 TMPR0 RD ETMP1[7] ETMP1[6] ETMP1[5] ETMP1[4] ETMP1[3] ETMP1[2] ETMP1[1] ETMP1[0] TMPR1 RD ETMP2[3] ETMP2[2] ETMP2[1] ETMP2[0] ETMP1[11] ETMP1[10] ETMP1[9] ETMP1[8] TMPR2 RD ETMP2[11] ETMP2[10] ETMP2[9] ETMP2[8] ETMP2[7] ETMP2[6] ETMP2[5] ETMP2[4] TMPR3 RD ITMP[7] ITMP[6] ITMP[5] ITMP[4] ITMP[3] ITMP[2] ITMP[1] ITMP[0] TMPR4 RD NA NA NA THSD ITMP[11] ITMP[10] ITMP[9] ITMP[8] Table 14. Packet Error Code (PEC) REGISTER PEC RD/WR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 RD PEC[7] PEC[6] PEC[5] PEC[4] PEC[3] PEC[2] PEC[1] PEC[0] Table 15. Diagnostic Register Group REGISTER RD/WR BIT 7 BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 DGNR0 RD REF[7] REF[6] REF[5] REF[4] REF[3] REF[2] REF[1] REF[0] DGNR1 RD REV[1] REV[0] MUXFAIL NA REF[11] REF[10] REF[9] REF[8] 680324f 24 LTC6803-2/LTC6803-4 OPERATION Table 16. Memory Bit Descriptions NAME CDC DESCRIPTION Comparator Duty Cycle VALUES CDC UV/OV COMPARATOR PERIOD VREF POWERED DOWN BETWEEN MEASUREMENTS CELL VOLTAGE MEASUREMENT TIME 0 (Default) N/A (Comparator Off) Standby Mode Yes N/A 1 N/A (Comparator Off) No 13ms 2 13ms No 13ms 3 130ms No 13ms 4 500ms No 13ms 5 130ms Yes 21ms 6 500ms Yes 21ms 7 2000ms Yes 21ms CELL10 10-Cell Mode 0 = 12-cell mode (default); 1 = 10-cell mode LVLPL Level Polling Mode 0 = toggle polling (default); 1 = level polling GPIO1 GPIO1 Pin Control GPIO2 GPIO2 Pin Control Write: 0 = GPIO1 pin pull-down on; 1 = GPIO1 pin pull-down off (default) Read: 0 = GPIO1 pin at logic ‘0’; 1 = GPIO1 pin at logic ‘1’ Write: 0 = GPIO2 pin pull-down on; 1 = GPIO2 pin pull-down off (default) Read: 0 = GPIO2 pin at logic ‘0’; 1 = GPIO2 pin at logic ‘1’ WDT Watchdog Timer Read: 0 = WDTB pin at logic ‘0’; 1 = WDTB pin at logic ‘1’ DCCx Discharge Cell x x = 1..12 0 = turn off shorting switch for cell ‘x’ (default); 1 = turn on shorting switch VUV Undervoltage Comparison Voltage* Comparison voltage = (VUV –31) • 16 • 1.5mV (Default VUV = 0) VOV Overvoltage Comparison Voltage* Comparison voltage = (VOV –32) • 16 • 1.5mV (Default VOV = 0) MCxI Mask Cell x Interrupts x = 1..12 0 = enable interrupts for cell ‘x’ (default) 1 = turn off interrupts and clear flags for cell ‘x’ CxV Cell x Voltage* x = 1..12 12-bit ADC measurement value for cell ‘x’ cell voltage for cell ‘x’ = (CxV –512) • 1.5mV reads as 0xFFF while A/D conversion in progress CxUV Cell x Undervoltage Flag x = 1..12 cell voltage compared to VUV comparison voltage 0 = cell ‘x’ not flagged for undervoltage condition; 1 = cell ‘x’ flagged CxOV Cell x Overvoltage Flag x = 1..12 cell voltage compared to VOV comparison voltage 0 = cell ‘x’ not flagged for overvoltage condition; 1 = cell ‘x’ flagged ETMPx External Temperature Measurement* Temperature measurement voltage = (ETMPx –512) • 1.5mV THSD Thermal Shutdown Status 0 = thermal shutdown has not occurred; 1 = thermal shutdown has occurred Status cleared to ‘0’ on read of Thermal Register Group REV Revision Code Device revision code ITMP Internal Temperature Measurement* Temperature measurement voltage = (ITMP –512) • 1.5mV = 8mV • T(°K) PEC Packet Error Code Cyclic redundancy check (CRC) value REF Reference Voltage for Diagnostics This reference voltage = (REF –512) • 1.5mV. Normal range is within 2.1V to 2.9V *Voltage equations use the decimal value of the registers, 0 to 4095 for 12-bit and 0 to 255 for 8-bit registers 680324f 25 LTC6803-2/LTC6803-4 OPERATION SERIAL COMMAND EXAMPLES LTC6803-2/LTC6803-4 (Addressable Configuration) Examples below use a configuration of three stacked devices: bottom (B), middle (M), and top (T) Write Configuration Registers (Figure 7) (Broadcast Write) 1. Pull CSBI low 2. Send WRCFG command and its PEC byte 3. Send CFGR0 byte, then CFGR1, …CFGR5, PEC byte (All devices on the bus receive the same data) 4. Pull CSBI high; data latched into all devices on rising edge of CSBI. S pins respond as data latched Calculation of serial interface time for sequence above: Number of devices in stack = N Number of bytes in sequence = B = 2 command byte and 7 data bytes = 2 + 7 Serial port frequency per bit = F Time = (1/F) * B * 8 bits/byte = (1/F) * (2 + 7) * 8 Time for 3-cell example above, with 1MHz serial port = (1/1000000) * (2 + 7)*8 = 72µs Read Cell Voltage Registers (12 battery cells, addressable read) 1. Pull CSBI low 2. Send Address and PEC byte for bottom device 3. Send RDCV command and its PEC byte 4. Read CVR00 byte of bottom device, then CVR01 (B), CVR02 (B), … CVR17 (B), and then PEC (B) 5. Pull CSBI high 6. Repeat steps 1-5 for middle device and top device Calculation of serial interface time for sequence above: Number of devices in stack = N Number of bytes in sequence = B = 2 address bytes, 2 command bytes, and 18 data bytes plus 1 PEC byte = 23 * N Serial port frequency per bit = F Time = (1/F) * B * 8 bits/byte = (1/F) * (23 * N) * 8 Time for 3-cell example above, with 1MHz serial port = (1/1000000) * (23 * N) * 8 = 552µs 680324f 26 LTC6803-2/LTC6803-4 OPERATION Start Cell Voltage ADC Conversions and Poll Status (Broadcast Command with Toggle Polling) 1. Pull CSBI low 2. Send STCVAD command and its PEC byte (all devices in stack start ADC conversions simultaneously) 3. SDO output of all devices in parallel pulled low for approximately 12ms 4. SDO output toggles at 1kHz rate, indicating conversions complete for all devices 5. Pull CSBI high to exit polling Poll Interrupt Status (Level Polling) 1. Pull CSBI low 2. Send Address and PEC bytes for bottom device 3. Send PLINT command and PEC bytes 4. SDO output from bottom device pulled low if any device has an interrupt condition; otherwise, SDO high 5. Pull CSBI high to exit polling 6. Repeat steps 1-5 for middle device and top device CSBI SCKI SDI WRCFG + CFGR + PEC td Sn (n = 1 TO 12) td < 2µs IF Sn IS UNLOADED Sn, DISCHARGE PIN STATE 680324 F07 Figure 7. S Pin Action and SPI Transmission 680324f 27 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION DIFFERENCE BETWEEN THE LTC6803-2 AND LTC6803‑4 The only difference between the LTC6803-2 and the LTC6803-4 is the bonding of the V– and C0 pins. The V– and C0 are separate signals on every LTC6803 die. In the LTC6803-2 package, the V– and C0 signals are shorted together by bonding these signals to the same pin. In the LTC6803‑4 package, V– and C0 are separate pins. Therefore, the LTC6803-2 is pin compatible with the LTC6802-2. For new designs the LTC6803-4 pinout allows a Kelvin connection to C0 (Figure 22). Larger series resistors and shunt capacitors can be used to lower the filter bandwidth. The measurement error due to the larger component values is a complex function of the component values. The error also depends on how often measurements are made. Table 17 is an example. In each example a 3.6V cell is being measured and the error is displayed in millivolts. There is a RC filter in series with inputs C1 through C12. There is no filter in series with C0. There is an interaction between cells. This is why the errors for C1 and C12 differ from C2 through C11. Table 17. Cell Measurement Errors vs Input RC Values CELL VOLTAGE FILTERING The LTC6803 employs a sampling system to perform its analog-to-digital conversions and provides a conversion result that is essentially an average over the 0.5ms conversion window, provided there isn’t noise aliasing with respect to the delta-sigma modulator rate of 512kHz. This indicates that a lowpass filter with 30dB attenuation at 500kHz may be beneficial. Since the delta-sigma integration bandwidth is about 1kHz, the filter corner need not be lower than this to assure accurate conversions. Series resistors of 100Ω may be inserted in the input paths without introducing meaningful measurement error. Shunt capacitors may be added from the cell inputs to V–, creating RC filtering as shown in Figure 8. The cell balancing MOSFET in Figure 11 can cause a small transient when it switches on and off. Keeping the cutoff frequency of the RC filter relatively high will allow adequate settling prior to the actual conversion. A delay of about 500µs is provided in the ADC timing, so a 16kHz LPF is optimal (100Ω, 0.1µF) and offers about 30dB of noise rejection. 100Ω Cn 100nF + 7.5V 100Ω 100nF 680324 F08 C(n – 1) Figure 8. Adding RC Filtering to the Cell Inputs (One Cell Connection Shown) R = 100Ω, R = 1k, C = 0.1µF C = 0.1µF Cell 1 Error (mV, LTC6803-2) Cell 2 to Cell 12 (mV) R = 1k, C = 1µF R = 10k, C = 3.3µF 0.1 4.5 1.5 1.5 1 9 3 0.5 For the LTC6803-2, no resistor should be placed in series with the V– pin. Because the supply current flows from the V– pin, any resistance on this pin could generate a significant conversion error for cell 1, and the error of cell 1 caused by the RC filter differs from errors of cell 2 to cell 2. OPEN-CONNECTION DETECTION When a cell input (C pin) is open, it affects two cell measurements. Figure 9 shows an open connection to C3, in an application without external filtering between the C pins and the cells. During normal ADC conversions (that is, using the STCVAD command), the LTC6803 will give near zero readings for B3 and B4 when C3 is open. The zero reading for B3 occurs because during the measurement of B3, the ADC input resistance will pull C3 to the C2 potential. Similarly, during the measurement of B4, the ADC input resistance pulls C3 to the C4 potential. Figure 10 shows an open connection at the same point in the cell stack as Figure 9, but this time there is an external filtering network still connected to C3. Depending on the value of the capacitor remaining on C3, a normal measurement of B3 and B4 may not give near-zero readings, since the C3 pin is not truly open. In fact, with a large external capacitance on C3, the C3 voltage will be charged midway 680324f 28 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION + B4 B3 + 18 + 20 + 22 24 + 1 increase the B4 measurement result relative to the normal STCVAD command. The biggest change is observed in the B4 measurement when C3 is open. So, the best method to detect an open wire at input C3 is to look for an increase in the value of battery connected between inputs C3 and C4 (battery B4). LTC6803-4 C4 C3 C2 MUX C1 V– The following algorithm can be used to detect an open connection to cell pin Cn: 100µA 1. Issue a STOWAD command (with 100µA sources connected). 680324 F09 2. Issue a RDCV command and store all cell measurements into array CELLA(n). Figure 9. Open Connection 3. Issue the 2nd STOWAD command (with 100µA sources connected). + B4 B3 + + 18 CF4 20 CF3 + 22 + 24 1 C4 LTC6803-4 C3 C2 MUX C1 V– 100µA 680324 F10 Figure 10. Open Connection with RC Filtering between C2 and C4 after several cycles of measuring cells B3 and B4. Thus the measurements for B3 and B4 may indicate a valid cell voltage when in fact the exact state of B3 and B4 is unknown. To reliably detect an open connection, the command STOWAD is provided. With this command, two 100µA current sources are connected to the ADC inputs and turned on during all cell conversions. Referring again to Figure 10, with the STOWAD command, the C3 pin will be pulled down by the 100µA current source during the B3 cell measurement AND during the B4 cell measurement. This will tend to decrease the B3 measurement result and 4. Issue the 2nd RDCV command and store all cell measurements into array CELLB(n). 5. For battery cells, if CELLA(1) < 0 or CELLB(1) < 0, V– must be open. If CELLA(12) < 0 or CELLB(12) < 0, C12 must be open. For n = 2 to 11, if CELLB(n+1) – CELLA(n+1) > 200mV, or CELLB(n+1) reaches the full scale of 5.375V, then Cn is open. The 200mV threshold is chosen to provide tolerance for measurement errors. For a system with the capacitor connected to Cn larger than 0.5µF, repeating step 3 several times will discharge the external capacitor enough to meet the criteria. If the top C pin is open yet V+ is still connected, then the best way to detect an open connection to the top C pin is by comparing the sum of all cell measurements using the STCVAD command to an auxiliary measurement of the sum of all the cells, using a method similar to that shown in Figure 19. A significantly lower result for the sum of all 12 cells suggests an open connection to the top C pin, provided it was already determined that no other C pin is open. 680324f 29 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION USING THE S PINS AS DIGITAL OUTPUTS OR GATE DRIVERS The S outputs include an internal pull-up PMOS. Therefore the S pins will behave as a digital output when loaded with a high impedance, e.g. the gate of an external MOSFET. For applications requiring high battery discharge currents, connect a discrete PMOS switch device and suitable discharge resistor to the cell, and the gate terminal to the S output pin, as illustrated in Figure 11. Si2351DS + 3.3k Cn Since thermal shutdown interrupts normal operation, the internal temperature monitor should be used to determine when the device temperature is approaching unacceptable levels. Sn USING THE LTC6803 WITH LESS THAN 12 CELLS 33Ω 1W 680324 F11 detected on the device goes above approximately 145°C, the configuration registers will be reset to default states, turning off all discharge switches and disabling ADC conversions. When a thermal shutdown has occurred, the THSD bit in the temperature register group will go high. The bit is cleared by performing a read of the temperature registers (RDTMP command). Cn – 1 Figure 11. External Discharge FET Connection (One Cell Shown) POWER DISSIPATION AND THERMAL SHUTDOWN The MOSFETs connected to the Pins S1 through S12 can be used to discharge battery cells. An external resistor should be used to limit the power dissipated by the MOSFETs. The maximum power dissipation in the MOSFETs is limited by the amount of heat that can be tolerated by the LTC6803. Excessive heat results in elevated die temperatures. The electrical characteristics for the LTC6803 I-grade are guaranteed for die temperatures up to 85°C. Little or no degradation will be observed in the measurement accuracy for die temperatures up to 105°C. Damage may occur above 150°C, therefore the recommended maximum die temperature is 125°C. To protect the LTC6803 from damage due to overheating, a thermal shutdown circuit is included. Overheating of the device can occur when dissipating significant power in the cell discharge switches. The problem is exacerbated when operating with a large voltage between V+ and V–. The thermal shutdown circuit is enabled whenever the device is not in standby mode (see Modes of Operation). It will also be enabled when any current mode input or output is sinking or sourcing current. If the temperature If the LTC6803 is powered by the stacked cells, the minimum number of cells is governed by the supply voltage requirements of the LTC6803. The sum of the cell voltages must be 10V to guarantee that all electrical specifications are met. Figure 12 shows an example of the LTC6803-4 when used to monitor seven cells. The lowest C inputs connect to the seven cells and the upper C inputs connect to C12. Other configurations, e.g., 9 cells, would be configured in the same way: the lowest C inputs connected to the battery cells and the unused C inputs connected to C12. The unused inputs will result in a reading of 0V for those channels. The ADC can also be commanded to measure a stack of 10 or 12 cells, depending on the state of the CELL10 bit in the control register. The ADC can also be commanded to measure any individual cell voltage. FAULT PROTECTION Care should always be taken when using high energy sources such as batteries. There are numerous ways that systems can be (mis)configured when considering the assembly and service procedures that might affect a battery system during its useful lifespan. Table 18 shows the various situations that should be considered when planning protection circuitry. The first five scenarios are to be anticipated during production and appropriate protection is included within the LTC6803 device itself. 680324f 30 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION Internal Protection Diodes NEXT HIGHER GROUP OF 7 CELLS 100 + + + + + + + V+ C12 S12 C11 S11 C10 S10 C9 S9 C8 S8 C7 S7 LTC6803-4 C6 S6 C5 S5 C4 S4 C3 S3 C2 S2 C1 S1 C0 V– 680324 F12 NEXT LOWER GROUP OF 7 CELLS Figure 12. Monitoring 7 Cells with the LTC6803-4 Each pin of the LTC6803 has protection diodes to help prevent damage to the internal device structures caused by external application of voltages beyond the supply rails as shown in Figure 13. The diodes shown are conventional silicon diodes with a forward breakdown voltage of 0.5V. The unlabeled Zener diode structures have a reverse breakdown characteristic which initially breaks down at 12V then snaps back to a 7V clamping potential. The Zener diodes labeled ZCLAMP are higher voltage devices with an initial reverse breakdown of 30V snapping back to 25V. The forward voltage drop of all Zeners is 0.5V. Refer to this diagram in the event of unpredictable voltage clamping or current flow. Limiting the current flow at any pin to ±10mA will prevent damage to the IC. READING EXTERNAL TEMPERATURE PROBES The LTC6803 includes two channels of ADC input, VTEMP1 and VTEMP2, that are intended to monitor thermistors (tempco about –4%/°C generally) or diodes (–2.2mV/°C typical) located within the cell array. Sensors can be powered directly from VREF as shown in Figure 14 (up to 60µA total). Table 18. LTC6803 Failure Mechanism Effect Analysis SCENARIO EFFECT DESIGN MITIGATION Cell input open-circuit (random) Power-up sequence at IC inputs Clamp diodes at each pin to V+ and V– (within IC) provide alternate power path Cell input open-circuit (random) Differential input voltage overstress Zener diodes across each cell voltage input pair (within IC) limits stress Disconnection of a harness between Loss of supply connection to the IC a group of battery cells and the IC (in a system of stacked groups) Separate power may be provided by a local supply Data link disconnection between LTC6803 and the master Loss of serial communication (no stress to ICs) The device will enter standby mode within 2 seconds of disconnect. Discharge switches are disabled in standby mode Cell-pack integrity, break between stacked units No effect during charge or discharge Use digital isolators to isolate the LTC6803-2/LTC6803-4 serial port from other LTC6803-2/LTC6803-4 serial ports Cell-pack integrity, break within stacked unit Cell input reverse overstress during discharge Add parallel Schottky diodes across each cell for load-path redundancy. Diode and connections must handle full operating current of stack, will limit stress on IC Cell-pack integrity, break within stacked unit Cell input positive overstress during charge Add SCR across each cell for charge-path redundancy. SCR and connections must handle full charging current of stack, will limit stress on IC by selection of trigger Zener 680324f 31 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 V+ LTC6803-4 VREG VREF VTEMP2 VTEMP1 NC V– LTC6803-4 C12 S12 C11 ZCLAMP S11 100k 1µF 1µF 100k 100k NTC 100k NTC 680324 F14 C10 ZCLAMP S10 ZCLAMP Figure 14. Driving Thermistors Directly from VREF ZCLAMP C9 S9 A3 C8 A2 S8 A1 C7 A0 S7 C6 ZCLAMP S6 VREG VREF VTEMP2 C5 VTEMP1 S5 C4 S4 CSBI C3 SDO S3 SDI C2 SCKI S2 GPIO2 ZCLAMP C1 GPIO1 S1 WDTB C0 TOS V– 27 NOTE: NOT SHOWN ARE PN DIODES TO ALL OTHER PINS FROM PIN 27 40 + 39 LT6000 38 37 32 31 30 – LTC6803-4 VREG VREF VTEMP2 VTEMP1 NC V– 29 44 43 42 41 36 35 34 33 10k 10k 10k NTC 10k NTC 680324 F15 Figure 15. Buffering VREF for Higher Current Sensors Expanding Probe Count As shown Figure 16, a dual 4:1 multiplexer is used to expand the general purpose VTEMP1 and VTEMP2 ADC inputs to accept 8 different probe signals. The channel is selected by setting the general purpose digital outputs GPIO1 and GPIO2 and the resultant signals are buffered by sections of the LT6004 micropower dual operational amplifier. The probe excitation circuitry will vary with probe type and is not shown here. 680324 F13 Figure 13. Internal Protection Diodes For sensors that require higher drive currents, a buffer op amp may be used as shown in Figure 15. Power for the sensor is actually sourced indirectly from the VREG pin in this case. Probe loads up to about 1mA maximum are supported in this configuration. Since VREF is shut down during the LTC6803 idle and shutdown modes, the thermistor drive is also shut off and thus power dissipation minimized. Since VREG remains always on, the buffer op amp (LT6000 shown) is selected for its ultralow power consumption (12µA). Another method of multiple sensor support is possible without the use of any GPIO pins. If the sensors are PN diodes and several used in parallel, then the hottest diode will produce the lowest forward voltage and effectively establish the input signal to the VTEMP input(s). The hottest diode will therefore dominate the readout from the VTEMP inputs that the diodes are connected to. In this scenario, the specific location or distribution of heat is not known, but such information may not be important in practice. Figure 17 shows the basic concept. In any of the sensor configurations shown, a full-scale cold readout would be an indication of a failed-open sensor connection to the LTC6803. 680324f 32 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION ADDING CALIBRATION AND FULL-STACK MEASUREMENTS PROBE8 PROBE7 PROBE6 PROBE5 6 5 + – 4 7 8 1/2 LT6004 1 2 3 4 5 6 7 8 Y0 VCC X2 Y2 X1 Y X Y3 74HC4052 X0 Y1 X3 INH A VEE GND B 16 15 14 13 12 11 10 9 The general purpose VTEMP ADC inputs may be used to digitize any signals from 0V to 4V with accuracy corresponding closely with that of the cell 1 ADC input. One useful signal to provide is a high accuracy voltage reference, such as 3.300V from an LTC6655-3.3. From periodic readings of this signal, the host software can provide correction of the LTC6803 readings to improve the accuracy over that of the internal LTC6803 reference and/or validate ADC operation. Figure 18 shows a means of selectively powering an LTC6655-3.3 from the battery stack, under the control of the GPIO1 output of the LTC6803-2. Since the operational power of the reference IC would add significant thermal loading to the LTC6803 if powered from VREG, an external high voltage NPN pass transistor is used to form a local 4.4V (Vbe below VREG) from the battery stack. The GPIO1 signal controls a PMOS FET switch to activate the reference when calibration is to be performed. Since GPIO signals default to logic high in shutdown, the reference will automatically turn off during idle periods. PROBE4 PROBE3 PROBE2 PROBE1 CPO2 GPO1 VREG VTEMP2 VTEMP1 1/2 LT6004 8 + 3 1 2 4 – 680324 F16 1µF V– Figure 16. Expanding Sensor Count with Multiplexing LTC6803-4 VREG VREF VTEMP2 VTEMP1 NC V– 200k Another useful signal is a measure of the total stack potential. This provides a redundant operational measurement of the cells in the event of a malfunction in the normal acquisition process, or as a faster means of monitoring the entire stack potential. Figure 19 shows how a resistive divider is used to derive a scaled representation of a full cell group potential. A MOSFET is used to disconnect 200k 680324 F17 Figure 17. Using Diode Sensors as Hot Spot Detectors TOP CELL POTENTIAL CZT5551 LTC6803-2 35 GPIO1 VREG VTEMP1 V– 1M Si2351DS 31 LTC6655-3.3 8 GND SHDN 7 2 VOUT_F VIN 6 3 GND VOUT_S 5 4 GND GND 1 28 26 100nF 1µF 10µF 680324 F18 Figure 18. Providing Measurement of Calibration Reference 680324f 33 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION PROVIDING HIGH SPEED ISOLATION OF THE SPI DATA PORT 499k CELLGROUP+ 1M 1 2N7002K WDTB 2 VREG 8 1 VTEMP1 3 + 1/2 LT6004 1µF 2 – 3 10nF 4 V– 31.6k CELLGROUP– 680324 F19 Figure 19. Using a VTEMP Input for Full-Stack Readings the resistive loading on the cell group when the IC enters standby mode (i.e., when WDTB goes low). An LT6004 micropower operational amplifier section is shown for buffering the divider signal to preserve accuracy. This circuit has the virtue that it can be converted about four times more frequently than the entire battery array, thus offering a higher sample rate option at the expense of some precision/accuracy, reserving the high resolution cell readings for calibration and balancing data. 1 5V_HOST 2 SPI_CLOCK SPI_CHIPSELECT SPI_MASTEROUT SPI_MASTERIN 100Ω 3 100Ω 4 100Ω 5 100Ω 6 1µF 7 8 GND_HOST 1µF Si8441AB-C-IS QUAD ISOLATOR VDD1 VDD2 GND1 GND2 A1 B1 A2 B2 A3 B3 A4 B4 EN1 EN2 GND1 GND2 Isolation techniques that are capable of supporting the 1Mbps data rate of the LTC6803-2/LTC6803-4 require more power on the isolated (battery) side than can be furnished by the VREG output of the LTC6803-2/LTC6803-4. To keep battery drain minimal, this means that a DC/DC function must be implemented along with a suitable data isolation circuit, such as shown in Figure 20. A quad (3 + 1) data isolator Si8441AB-C-IS is used to provide non-galvanic SPI signal connections between a host microprocessor and an LTC6803-2/LTC6803-4. An inexpensive isolated DC/ DC converter provides powering of the isolator function completely from the host 5V power supply. A quad threestate buffer is used to allow SPI inputs at the LTC6803-2/ LTC6803-4 to rise to a logic high level when the isolator circuitry powers down, assuring the lowest power consumption in the standby condition. The pull-ups to VREG are selected to match the internal loading on VREG by ICs operating with a current mode SPI interface, thus balancing the current in all cells during operation. The additional pull-up on the SDO line (1k resistor and Schottky diode) is to improve rise time, in lower data rate applications this may not be needed. CMDSH2-3 16 15 14 13 12 4.22k 11 1/4 74ABT126 13 12 1 2 11 10 1k 4.22k 3 1/4 74ABT126 1µF 9 CSB1 4 5 4.22k 6 1/4 74ABT126 4.22k 10 8 LTC1693-2 8 IN1 VCC1 2 7 GND1 OUT1 3 6 IN2 VCC2 4 5 GND2 OUT2 470pF 20.0k 33nF PE-68386 1• •6 3 4 BAT54S 74ABT126 SUPPLY SHARED WITH ISOLATOR VDD2 and GND2 SCI SDO 9 1/4 74ABT126 1 VREG SCKI 680324 F20 V– 10.0k Figure 20. Providing an Isolated High Speed Data Interface 680324f 34 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION SUPPLY DECOUPLING IF BATTERY-STACK POWERED ADVANTAGES OF KELVIN CONNECTION ON C0 As shown in Figure 21, the LTC6803-4 can have filtering on both V+ and V–, so differential bypassing to the cell group potentials is recommended. The Zener suppresses overvoltages from reaching the IC supply pins. A small ferrite-bead inductor provides protection for the Zener, particularly from energetic ESD strikes. Since the LTC6803-2 cannot have a series resistance to V–, additional Schottky diodes are needed to prevent ESD-induced reverse-supply (substrate) currents to flow. The V– trace resistance can cause an observable voltage drop between the negative end of the bottom battery cell and V– pin of LTC6803. This voltage drop will add to the measurement error of the bottom cell voltage. The LTC6803‑4 separates C0 from V–, allowing Kelvin connection on C0 as shown in Figure 22. Voltage drop on the V– trace will not affect the bottom cell voltage measurement. The Kelvin connection will also allow RC filtering on V– as shown in Figure 21. CELLGROUP+ BLM31PG330SN1L 100Ω CMHZ5265B V+ 100nF BAT46W CELLGROUP– V– LTC6803-2 Configuration CELLGROUP+ BLM31PG330SN1L CMHZ5265B 100Ω 100Ω CELLGROUP– 680324 F21 V+ 100nF V– LTC6803-4 Configuration Figure 21. Supply Decoupling + + BATTERY STACK + LTC6803-4 C1 + C0 R ISUPPLY V– 68034 F20 Figure 22. Kelvin Connection on C0 Improving Bottom Cell Voltage Measurement Accuracy 680324f 35 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION HARDWARE SHUTDOWN PCB LAYOUT CONSIDERATIONS To completely shut down the LTC6803 a PMOS switch can be connected to V+, or, V+ can be driven from an isolated power supply. Figure 23 shows an example of a switched V+. The breakdown voltage of DZ4 is about 1.8V. If SHDN < 1.8V, no current will flow through the stacked MMBTA42s and the 1M resistors. TP0610Ks will be completely shut off. If SHDN > 2.5V, M7 will be turned on and then all TP0610Ks will be turned on. The VREG and VREF pins should be bypassed with a 1µF capacitor for best performance. The LTC6803 is capable of operation with as much as 55V between V+ and V–. Care should be taken on the PCB layout to maintain physical separation of traces at different potentials. The pinout of the LTC6803 was chosen to facilitate this physical separation. There is no more than 5.5V between any two adjacent pins. The package body is used to separate the highest voltage (e.g., 43.2V) from the lowest voltage (0V). V+ TP0610K 1M + + D1 + C12 DZ1 15V LTC6803-4 IC #3 C0 V– V+ TP0610K C12 DZ2 15V LTC6803-4 IC #2 + + 1M D2 C0 + V– V+ C12 LTC6803-4 IC #1 C0 V– TP0610K DZ3 15V 1M SHDN DZ4 1.8V 50k + + + DZ1, DZ2, DZ3: MMSZ5245B DZ4: MMSZ4678T1 ALL NPN: MMBTA42 ALL PN: RS07J 680324 F23 Figure 23. Hardware Shutdown Circuit Reduces Total Supply Current of LTC6803-4 to About 0µA 680324f 36 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION As an example, Figure 24 shows the DC voltage on each pin with respect to V– when twelve 3.6V battery cells are connected to the LTC6803. ADVANTAGES OF DELTA-SIGMA ADCS The LTC6803 employs a delta-sigma analog-to-digital converter for voltage measurement. The architecture of delta-sigma converters can vary considerably, but the common characteristic is that the input is sampled many times over the course of a conversion and then filtered or averaged to produce the digital output code. In contrast, a SAR converter takes a single snapshot of the input voltage and then performs the conversion on this single sample. For measurements in a noisy environment, a delta-sigma converter provides distinct advantages over a SAR converter. 43.2V 43.2V 43.2V 39.6V 39.6V 36V 36V 32.4V 32.4V 28.8V 28.8V 25.2V 25.2V 21.6 21.6 18V 18V 14.4V 14.4V 10.8 10.8 7.2 While SAR converters can have high sample rates, the fullpower bandwidth of a SAR converter is often greater than 1MHz, which means the converter is sensitive to noise out to this frequency. And many SAR converters have much higher bandwidths—up to 50MHz and beyond. It is possible to filter the input, but if the converter is multiplexed to measure several input channels a separate filter will be required for each channel. A low frequency filter cannot reside between a multiplexer and an ADC and achieve a high scan rate across multiple channels. Another consequence of filtering a SAR ADC is that any noise reduction gained by filtering the input cancels the benefit of having a high sample rate in the first place, since the filter will take many conversion cycles to settle. CSBI V+ SDO C12 SDI S12 SCKI C11 A3 S11 A2 C10 A1 S10 LTC6803-4 A0 C9 GPIO2 S9 GPIO1 C8 WDTB S8 TOS C7 VREG S7 VREF C6 VTEMP2 S6 VTEMP1 C5 NC S5 V– C4 C0 S4 S1 C3 C1 S3 S2 C2 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 0V TO 5.5V 5V 3.1V 1.5V 1.5V 0V 0V 0V 3.6V 3.6V 7.2V 680324 F24 Figure 24. Typical Pin Voltages for Twelve 3.6V Cells 680324f 37 LTC6803-2/LTC6803-4 APPLICATIONS INFORMATION Converter Details The LTC6803 ADC has a 2nd order delta-sigma modulator followed by a SINC2, finite impulse response (FIR) digital filter. The front-end sample rate is 512ksps, which greatly reduces input filtering requirements. A simple 16kHz, 1-pole filter composed of a 100Ω resistor and a 0.1≤F capacitor at each input will provide adequate filtering for most applications. These component values will not degrade the DC accuracy of the ADC. Each conversion consists of two phases—an autozero phase and a measurement phase. The ADC is autozeroed at each conversion, greatly improving CMRR. The second half of the conversion is the actual measurement. Noise Rejection Figure 25 shows the frequency response of the ADC. The roll-off follows a SINC2 response, with the first notch at 4kHz. Also shown is the response of a 1 pole, 850Hz filter (187µs time constant) which has the same integrated response to wideband noise as the LTC6803 ADC, which is about 1350Hz. This means that if wideband noise is applied to the LTC6803 input, the increase in noise seen at the digital output will be the same as an ADC with a wide bandwidth (such as a SAR) preceded by a perfect 1350Hz brick wall lowpass filter. Thus if an analog filter is placed in front of a SAR converter to achieve the same noise rejection as the LTC6803 ADC, the SAR will have a slower response to input signals. For example, a step input applied to the input of the 850Hz filter will take 1.55ms to settle to 12 bits of precision, while the LTC6803 ADC settles in a single 1ms conversion cycle. This also means that very high sample rates do not provide any additional information because the analog filter limits the frequency response. While higher order active filters may provide some improvement, their complexity makes them impractical for high channel count measurements as a single filter would be required for each input. Also note that the SINC2 response has a 2nd order rolloff envelope, providing an additional benefit over a single pole analog filter. 10 0 FILTER GAIN (dB) For a given sample rate, a delta-sigma converter can achieve excellent noise rejection while settling completely in a single conversion—something that a filtered SAR converter cannot do. Noise rejection is particularly important in high voltage switching controllers, where switching noise will invariably be present in the measured voltage. Other advantages of delta-sigma converters are that they are inherently monotonic, meaning they have no missing codes, and they have excellent DC specifications. –10 –20 –30 –40 –50 –60 10 100 1k 10k FREQUENCY (Hz) 100k 680324 F25 Figure 25. Noise Filtering of the LTC6803-4 ADC 680324f 38 LTC6803-2/LTC6803-4 PACKAGE DESCRIPTION G Package 44-Lead Plastic SSOP (5.3mm) (Reference LTC DWG # 05-08-1754 Rev Ø) 12.50 – 13.10* (.492 – .516) 1.25 ±0.12 7.8 – 8.2 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 5.3 – 5.7 0.25 ±0.05 RECOMMENDED SOLDER PAD LAYOUT APPLY SOLDER MASK TO AREAS THAT ARE NOT SOLDERED 5.00 – 5.60* (.197 – .221) PARTING LINE 0.10 – 0.25 (.004 – .010) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2.0 (.079) MAX 1.65 – 1.85 (.065 – .073) 0° – 8° 0.55 – 0.95** (.022 – .037) 1.25 (.0492) REF NOTE: 1.DRAWING IS NOT A JEDEC OUTLINE 2. CONTROLLING DIMENSION: MILLIMETERS 3. DIMENSIONS ARE IN 0.50 BSC 7.40 – 8.20 (.291 – .323) MILLIMETERS (INCHES) 4. DRAWING NOT TO SCALE 5. FORMED LEADS SHALL BE PLANAR WITH RESPECT TO ONE ANOTHER WITHIN 0.08mm AT SEATING PLANE 0.50 (.01968) BSC SEATING PLANE 0.20 – 0.30† (.008 – .012) TYP 0.05 (.002) MIN G44 SSOP 0607 REV Ø *DIMENSIONS DO NOT INCLUDE MOLD FLASH OR PROTRUSIONS, BUT DO INCLUDE MOLD MISMATCH AND ARE MEASURED AT THE PARTING LINE. MOLD FLASH SHALL NOT EXCEED .15mm PER SIDE **LENGTH OF LEAD FOR SOLDERRING TO A SUBSTRATE †THE MAXIMUM DIMENSION DOES NOT INCLUDE DAMBAR PROTRUSIONS. DAMBAR PROTRUSIONS DO NOT EXCEED 0.13mm PER SIDE 680324f Information furnished by Linear Technology Corporation is believed to be accurate and reliable. However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights. 39 LTC6803-2/LTC6803-4 TYPICAL APPLICATION Typical 12-Cell Measurement Block CELL 12 MMSZ5267B IMC1210ER100K BAT46W BAT46W 100Ω 100nF C12FILTER DC12 C11FILTER DC11 C10FILTER DC10 C9FILTER DC9 C8FILTER REPEAT INPUT CIRCUITS FOR CELL3 TO CELL12 DC8 C7FILTER DC7 C6FILTER DC6 C5FILTER DC5 C4FILTER DC4 C3FILTER DC3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 LTC6803-2 V+ CSBI C12 SDO S12 SDI C11 SCKI S11 A3 C10 A2 S10 A1 C9 A0 S9 GPIO2 C8 GPIO1 S8 WDTB C7 NC S7 TOS C6 VREG VREF S6 VTEMP2 C5 VTEMP1 S5 NC C4 V– S4 S1 C3 C1 S3 S2 C2 1M 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 1M 1M CSBI SDO* SDI SCKI *REQUIRES 1K PULL-UP RESISTOR AT HOST DEVICE 1M 1M 1M 10.0k 1µF RQJ0303PGDQALT 33Ω CELL1 100nF + PDZ7.5B 5 6 – + 1 10nF 4 8 1/2 LT6004 – 7 10.0k 100nF NTC1 1k 4 10nF C1FILTER 100Ω NTC2 1k 8 1/2 LT6004 3.3k 475Ω RQJ0303PGDQALT 33Ω 100Ω 1µF 3 2 C2FILTER CELL2 SPI PORT TO HOST µP OR DATA ISOLATOR 680324 TA02 PDZ7.5B 3.3k 475Ω RELATED PARTS PART NUMBER DESCRIPTION COMMENTS LTC6801 Independent Multicell Battery Stack Fault Monitor Monitors Up to 12 Series-Connected Battery Cells for Undervoltage or Overvoltage. Companion to the LTC6802 and LTC6803 family LTC6802-1 Multicell Battery Stack Monitor with Parallel Addressed Serial Interface Functionally Equivalent to the LTC6803-1 and the LTC6803-3 LTC6802-2 Multicell Battery Stack Monitor with an Individually Addressable Serial Interface Functionally Equivalent to LTC6803-2/LTC6803-4. Pin Compatible with the LTC6803-2 LTC6803-1/ LTC6803-3 Multicell Battery Stack Monitor with Daisy-Chained Serial Interface Functionality Equivalent to LTC6803-2/LTC6803-4, Allows for Multiple Devices to Be Daisy Chained 680324f 40 Linear Technology Corporation LT 0211 • PRINTED IN USA 1630 McCarthy Blvd., Milpitas, CA 95035-7417 (408) 432-1900 ● FAX: (408) 434-0507 ● www.linear.com LINEAR TECHNOLOGY CORPORATION 2011