EX-245 Hi-Reliability Evacuated Miniature Crystal Oscillator EX-245 Features 16 pin Double Dip Package Ruggedized hybrid thick film construction Low Power Consumption Typical Applications Severe Environmental Conditions 10 MHz – 40 MHz 10, 20 MHz Frequency Range Standard Frequencies Frequency stabilities1 [10 to 20 MHz] Min Max Units -50 +50 ppb 0 … +60°C (Referenced to +25°C) -75 +75 ppb -20 … +70°C -100 +100 ppb -40 … +85°C Max Units Condition +1 +0.2 +15 +15 +2 +200 +1000 +1500 +2000 ppm ppm ppb ppb ppb ppb ppb ppb ppb Fixed, no adjust option 120 seconds to ± 1ppm of final freq. @+25°C 180 seconds to ± 100ppb of final freq. @+25°C Parameter Min Initial tolerance For Fixed Freq. Settability vs. supply voltage change vs. load vs. aging / day vs aging / 1 year vs. aging /10 year vs. aging /10 year vs. aging /10 year -1 -0.2 -15 -15 -2 -200 -1000 -1500 -2000 Warm-up Time Typ Typ Operating temp range Options5 Parameter vs. operating temperature range VS ± 5% Load ± 5% after 7 days of operation 10 to <12MHz 12 to <16MHz 16 to 20MHz http://www.vectron.com Rev. 02-06-09 daf Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100 Frequency stabilities1 [>20 to 40 MHz] Min vs. operating temperature range (Referenced to +25°C) Max Units -75 +75 ppb 0 … +60°C -100 +100 ppb -20 … +70°C -150 +150 ppb -40 … +85°C Max Units Condition +1.5 +0.3 +25 +25 +3 +300 +3000 ppm ppm ppb ppb ppb ppb ppb Fixed, no adjust option VS ± 5% Load ± 5% after 7 days of operation 120 seconds to ± 1ppm of final freq. @+25°C 180 seconds to ± 100ppb of final freq. @+25°C Parameter Min Initial tolerance For Fixed Freq. Settability vs. supply voltage change vs. load vs. aging / day vs aging / 1 year vs. aging /10 year -1.5 -0.3 -25 -25 -3 -300 -3000 Typ Typ Warm-up Time Operating temp range Options5 Parameter Supply Voltage (Vs) Parameter Supply voltage [Standard] Min Typ Max Units 4.75 5 5.25 VDC 2.2 Watts during warm-up 0.7 Watts steady state @ +25°C 1.2 Watts steady state @ -40°C Power consumption Condition RF Output Parameter Min Typ Signal [Standard] Max 15 Signal Level (Vol) Load Output Power [Standard] Output Power [Option] Harmonics Spurious Condition HCMOS Load Signal Level (Voh) Rise/Fall Time Duty cycle Signal [Option] Units pF 0.1 0.9 40 0.0 3.0 +7 60 Sinewave 50 +2.0 +5.0 4.0 7.0 -25 -60 VDD VDD ns % Ω dBm dBm dBc dBc (10-90%) @ (Voh-Vol)/2 50 Ohm load 50 Ohm load Frequency Tuning (EFC) Min Typ Max Units Tuning Range Fixed, No Adjust Tuning Range Sufficient to compensate for 10 years aging Vref 4.0 4.1 4.2 Vdc Condition EFC (0V to 4V) Options5 Parameter Source Current 1mA maximum http://www.vectron.com Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100 Additional Parameters1 [10 to 20 MHz] Parameter Phase Noise G-Sensitivity Max. Units Condition -100 dBc/Hz 10 -125 dBc/Hz 100 Hz -140 dBc/Hz 1 kHz -145 dBc/Hz 10 kHz -145 dBc/Hz 1 x 10-9 /g Hz 10 to 20 MHz 100 kHz Test at 10g sine vibration at 100Hz Additional Parameters1 [>20 to 40 MHz] Parameter Phase Noise G-Sensitivity Max. Units Condition -90 dBc/Hz 10 Hz -115 dBc/Hz 100 Hz -130 dBc/Hz 1 kHz -140 dBc/Hz 10 kHz -140 dBc/Hz 1 x 10-9 /g > 20 to 40 MHz 100 kHz Test at 10g sine vibration at 100Hz Environmental Conditions (Designed to meet) • Radiation Tolerant (operating): Active devices are selected from a family of product that is inherently radiation tolerant to meet 100krad (SI) total dose • Mechanical Shock (survive)***: MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec) • Vibration Random (survive)***: MIL-STD-202, Test Method 214, Condition I-F (20Grms, 3 minutes/axis) • Vibration Sine (survive)***: MIL-STD-202, Test Method 204, Condition D (20Grms, 20 minutes/axis) Note: *** Met by design, not tested http://www.vectron.com Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100 Screening Options Ordering Code S B Test Inspection S-Level Screening B-Level Screening Nondestructive Bond Pull MIL-STD-883 Method 2023 N/A Internal Visual Per Mil-PRF-55310 Requirement Internal Visual Per Mil-PRF-55310 Requirement Internal Visual Per Mil-PRF-55310 Requirement Stabilization Bake MIL-STD-883 Method 1008, Condition C 150°C for 48hrs MIL-STD-883 Method 1008, Condition C Thermal Shock MIL-STD-883 Method 1011, Condition A 0°C to 100°C for 15cycles N/A Temperature Cycling (1) MIL-STD-883 Method 1010, Condition A -55°C to 85°C (2) for 10cycles MIL-STD-883 Method 1010, Condition A -55°C to 85°C (2) for 10cycles Constant Acceleration (1) MIL-STD-883 Method 2001 1000g’s (3) Y1 Only MIL-STD-883 Method 2001 1000g’s (3) Y1 Only Seal (Fine & Gross Leak) (1) N/A (Vacuum Seal) PIND MIL-STD-883 Method 2020, Condition B 150°C for 48hrs N/A (Vacuum Seal) 10g peak at 60Hz minimum N/A Electrical Test Per Mil-PRF-55310 Requirement Per Mil-PRF-55310 Requirement Burn-in (1) 85°C (2) for 240hrs 85°C (2) for 240hrs Electrical Test Per Mil-PRF-55310 Requirement Per Mil-PRF-55310 Requirement Radiographic MIL-STD-883 Method 2012 N/A Note: (1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310. (2) The maximum operating and storage temperature of the EX-245 is +85°C. The EX-245 shall not be exposed to temperature higher than +85°C at length of time. (3) The design and construction of the EX-245 can withstand up to 1000g’s constant acceleration http://www.vectron.com Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100 Package Outline Pin Function Pin # With EFC Fixed Frequency 1 EFC No Connection 2-4 No Connection No Connection 8 Case/GND Case/GND 9 Output Output 13-14 No Connection No Connection 15 Vref No Connection 16 Supply Supply **Pin numbers are for reference Reflow Profile Reflow Profile o TEMPERATURE ( C) 220 183 150 60s 60-90s 45-60s TIME (s) http://www.vectron.com Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100 How to order this product: Use this worksheet to forward the following information to your factory representative : Model - EX-245 - Model Code: 245: Type A S u p p l y RF Output Temperature Vo l t a g e Code Range Code C A D Supply Voltage Code: C: 5 V Stability Options - 508 A S S - Frequency - 10M0000000 Crystal Options: S: Swept Quartz N: Non-Swept Quartz Temperature Range: K: 0 ... +60°C D: -20...+70°C F: -40...+85°C Screening Option: S: “S” Level Screening B: “B” Level Screening E: “EM” Engineering Model RF Output Code: A: CMOS G: Sinewave (0 dBm) H: Sinewave (+3 dBm) Other Options: A: Electrical Tuning F: Fixed Frequency Stability: 508: ±50ppb 758: ±75ppb 107: ±100ppb 157: ±150ppb Notes: 1 2 3 4 5 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies. Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage, load, temperature (25°C) Phase noise degrades with increasing output frequency. Subject to technical modification. Contact factory for availability. http://www.vectron.com Vectron International•267 LowellRoad, Hudson, New Hampshire 03051•Tel:+1-88-VECTRON-1 Vectron International GmbH & Co. KG • Landstraße, 74924 Neckarbischofsheim, Germany • Tel: +49 7268 801 100