VECTRON C4600_06

OCXO
C4600
Typical Applications
Features
Base Stations
Digital Switching
Synthesizers
Test Equipment
Standard Package
Low Aging
AT-Cut and SC-Cut Crystal Options
Fast Warm-up
Previous Vectron Model Numbers
OCO100, 4598, MC2001 Series
Frequency range
5 MHz – 40 MHz
Standard frequencies
10; 16.384 MHz
Frequency stabilities1 [AT Cut Crystal – Standard]
Parameter
vs. operating temperature range
(Referenced to +25°C)
Min
-30
-80
-100
-200
Min
-300
-5
-5
-2.0
-500
-250
Parameter
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging /1 day
vs aging /1 Year
vs. aging / year (following Years)
Warm-up Time
Typ
Typ
Max.
+30
+80
+100
+200
Max.
+300
+5
+5
+2.0
+500
+250
3
Units
ppb
ppb
ppb
ppb
Units
ppb
ppb
ppb
ppb
ppb
ppb
minutes
Operating temp range
Ordering Code
0 … +70°C
C308
-20 … +70°C
D808
-40 … +70°C
E107
-40 … +85°C
F207
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
Max.
+10
+15
+20
+30
Max.
+100
+5.0
+5.0
+1.0
+100
+50
3
Units
ppb
ppb
ppb
ppb
Units
ppb
ppb
ppb
ppb
ppb
ppb
minutes
Operating temp range
Ordering Code
0 … +70°C
C108
-20 … +70°C
D158
-40 … +70°C
E208
-40 … +85°C
F308
Condition
at time of shipment, nominal EFC
VS ± 5%
Load ± 5%
after 72 hours of operation
after 72 hours of operation
Max.
5.25
Units
VDC
to ± 100ppb of final frequency (1 hour reading) @
+25°C
Frequency stabilities1 [SC Cut Crystal – Option]
Parameter
vs. operating temperature range
(Referenced to +25°C)
Min
-10
-15
-20
-30
Min
-100
-5.0
-5.0
-1.0
-100
-50
Parameter
Initial tolerance
vs. supply voltage change
vs. load change
vs. aging /1 day
vs aging /1 Year
vs. aging / year (following Years)
Warm-up Time
Typ
Typ
to ± 10ppb of final frequency (1 hour reading) @
+25°C
Supply voltage (Vs)
Parameter
Supply voltage [Standard]
Typ
5
Supply voltage [Option]
11.4
12.0
12.6
VDC
Supply voltage [Option]
3.135
3.3
3.465
VDC
3.5
Watts
during warm-up
1.2
Watts
steady state @ +25°C
Power consumption
Condition
Ordering Code
SV050
Min
4.75
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
SV120
SV033
v.2006-11-10 · page 1 of 4
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
OCXO
C4600
RF output
Parameter
Signal [Standard]
Load
Min
Typ
Max.
Units
0.5
0.3
55
VDC
VDC
VDC
VDC
%
+8.0
-30
Ω
dBm
dBc
Condition
Ordering Code
RFH
HCMOS
15
pF
Signal Level (Vol)
Signal Level (Voh)
4.5
3.0
45
Duty cycle
Signal [Option]
Load
Output Power
Harmonics
Sinewave
+3.0
50
+5.5
with Vs=12.0V or 5.0V and 15pF load
with Vs=3.3V and 15pF load
with Vs=12.0V or 5.0V and 15pF load
with Vs=3.3V and 15pF load
@ (Voh-Vol)/2
RFS
50 Ohm load
50 Ohm load
Frequency Tuning (EFC)
Parameter
Tuning Range
Min
Typ
Max.
Fixed OCXO; No adjust
Tuning Range
±0.75
±1.25
±6.0
±8.0
Linearity
Tuning Slope
5
Units
Condition
Ordering Code
0
±2.0
ppm
with SC Cut Crystal
1
±12
ppm
with AT Cut Crystal
1
20
%
Positive
Control Voltage Range
0.0
2.0
4.0
VDC
0.0
2.5
5.0
VDC
with Vs=5.0VDC
with Vs=12VDC
0.0
1.5
3.0
VDC
with Vs=3.3VDC
Min
3.92
Typ
4.0
Max.
4.08
Units
VDC
Condition
with Vs=5.0VDC
Reference Voltage Output (Vref)
Parameter
Reference Voltage
4.9
5.0
5.1
VDC
with Vs=12VDC
2.75
2.8
2.85
VDC
with Vs=3.3VDC
Min
Typ
Additional parameters
Parameter
3
Phase Noise
3
Phase Noise
Weight
Processing & Packing
Max.
-85
-120
-140
-145
-150
-75
-100
-130
-140
-150
3.0
Handling & processing note
Units
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
g
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
1
10
100
1
10
1
10
100
1
10
Condition
Hz
with 10 MHz SC Cut
Hz
Hz
kHz
kHz
Hz
with 10 MHz AT Cut
Hz
Hz
kHz
kHz
v.2006-11-10 · page 2 of 4
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
OCXO
C4600
Enclosures
Type A
Package Codes:
Code
A1
A2
5
A3
Height “H”
19.00
15.00
12.70
Pin Length “L”
5.0
5.0
5.0
MARKING SURFACE
"H" MAX
"L" MAX
0.79 DI A.
(5-PL)
1
5
2
15.21
CENT
17.78
CENT
27.94 MAX
3
4
17.75
CENT
25.40
CENT
38.10 MAX
Dimensions: mm
Pin Connections
1
2
3
4
5
Electronic Frequency Control Input (EFC)
Reference Voltage Output
Supply Voltage Input (Vs)
RF Output
Ground (Case)
Absolute Maximum Ratings
Parameter
Supply voltage (Vs)
Min
Output Load
Operable temperature range
Storage temperature range
-55
-55
Typ
Max.
7.0
15.0
7.0
50
25
+85
+125
Units
V
V
V
pF
Ohms
°C
°C
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Condition
with Vs=5.0VDC
with Vs=12VDC
with Vs=3.3VDC
with HCMOS signal
with Sinewave signal
v.2006-11-10 · page 3 of 4
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
OCXO
C4600
How to order this product:
Step 1
Use this worksheet to forward the following information to your factory representative :
Model
Supply Voltage
Code
Stability Code
C4600
D808
RF Output Code
SV050
±30ppb
±80ppb
±100ppb
±200ppb
±10ppb
±15ppb
±20ppb
±30ppb
0 …+70°C
-20 …+70°C
-40 …+70°C
-40 …+85°C
0 …+70°C
-20 …+70°C
-40 …+70°C
-40 …+85°C
Frequency
Control/ Enable
Frequency
A1
1
5MHz
RFH
Vs.operat. Temp. Range
C308:
D808:
E107:
F207:
C108:
D158:
E208:
F208:
Package Code
Signal:
Tuning Range:
RFH: HCMOS
RFS: Sinewave
0: Fixed OCXO; No adjust
1: ±0.75 ppm..±2.0 ppm(SC)
1: ±6.0 ppm..±12.0 ppm(AT)
Enclosure:
A1: H: 19.0 L: 5
A2: H: 15.0 L: 5
A3: H: 12.7 L: 5
Supply:
SV033: 3.3V
SV050: 5V
SV120: 12V
Step 2
The factory representative will then respond with a Vectron Model Number in the following configuration:
Model
Package Code
Dash
Dash Number
C4600
[Customer Specified Package Code]
-
[Factory Generated 4 digit number]
Typical P/N = C4600A1-0001
Notes:
1 Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies.
2 Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control voltage,
load, temperature (25°C)
3 Phase noise degrades with increasing output frequency.
4 Subject to technical modification.
5 Contact factory for availability.
Vectron International · www.vectron.com
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
v.2006-11-10 · page 4 of 4
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax